• Title/Summary/Keyword: isotope measurement

Search Result 130, Processing Time 0.03 seconds

A Study on the Quantitative Recovery of Dissolved Inorganic Carbonates in Ground Water for Radiocarbon Measurement (방사성탄소 측정을 위한 지하수 중에 용존된 무기탄소 화합물의 정량적 회수 연구)

  • Chun, Sang-Ki;Woo, Hyung-Joo;Cho, Soo-Young;Kim, Nak-Bae;Lee, Jong-Dae
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.284-289
    • /
    • 1999
  • Dissolved inorganic carbonates in ground water were quantitatively recovered by using gas evolution method. Gas evolution method was found to be less time-consuming, less susceptible to the contamination fromatmospheric $CO_2$ and little affected by the sulfate ions in comparison to the direct precipitation method. Extraction efficiency of nearly 99% could be achieved by gas evolution method in two hours using recirculated gas at a sweeping rate of 4 liter per minute. Samples for carbon isotope fractionation study were collected in three fractions with collection times. The evolution time for the first fraction was one hours, and then second and third fractions were collected at intervals of 30 minutes, respectively. A small portion of each fraction was analyzed to evaluate ${\delta}^{13}C$ values, which were measured to be -7.9‰, -3.0‰ and +0,4‰ for the each fraction. The result clearly indicated that gas evolution method generates isotopically lighter carbon at the beginning of the purging process and heavier isotopes at the end. However, this isotope fractionation effect could be neglected by the almost complete recovery of carbonates.

  • PDF

Distribution of Fish Assemblage and Stable Isotope Composition of Reeds according to Geomorphic Characteristics of Lagoons along the East Sea (동해안 석호의 지형학적인 특성에 따른 어류군집분포와 갈대의 안정동위원소비)

  • Lee, Jaeyong;Park, Seungchul;Kim, Minseob;Choi, Jae-Seok;Lee, Kwangyeol;Shin, Kyunghoon
    • Korean Journal of Ecology and Environment
    • /
    • v.48 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • Abstract The purpose of study is to identify the relationship between stable isotope composition of reed stems in coastal and understand the structure of the fish community in 10 lagoons along the East Sea. The fish species composition (particularly, anadromous fish species) and relative abundance of trophic guilds was influenced by difference of geomorphic characteristics among lagoons. Reed stems ${\delta}^{13}C$ and ${\delta}^{15}N$ values ranged from $-28.40{\pm}0.11$‰ to $-26.87{\pm}0.25$‰ and $-1.09{\pm}1.45$‰ to $12.08{\pm}0.53$‰, respectively. The differences in reed stem ${\delta}^{15}N$ values might be associated with anthropogenic landuse and the geomorphic characteristics among lagoons. These results provide useful information to improve the conservation of fish habitats (biodiversity), preserve lagoon habitats and contribute to watershed management effect against anthropogenic pollution from watershed in these lagoon ecosystems.

Evaluation of Airborne Pb Sources in an Industrialized City by Applying Pb Isotope Ratios and Concentrations in PM10 (PM10 내 납의 동위원소와 농도를 활용한 산업도시지역 대기 중 납 오염원 평가)

  • Jo, Wan-Kuen;Lee, Heon-Chul;Kim, Mo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.174-182
    • /
    • 2011
  • The present study evaluated the major lead sources in a steel metallurgy industrialized city by measuring lead isotopes/lead concentrations of ambient air and potential sources in an industrial area and residential areas according to relative distance. The quality control program obtained during the measurement procedure for lead isotopes and concentrations exhibited $0.5ng/m^3$ for method detection limit, more than 90% for recoveries of standard particulate matters, and lower than 0.2% for reproducibility errors of four lead isotopes ($^{204}Pb$, $^{206}Pb$, $^{207}Pb$, $^{208}Pb$). For all three lead isotope ratios ($^{206}Pb/^{204}Pb$, $^{207}Pb/^{206}Pb$, $^{208}Pb/^{206}Pb$), the ratios were obtained in the industrial area were closer to nearby residential area than those of a residential area far away from the industrial area, thereby suggesting that lead sources were more similar each other in the industrial and nearby residential area. Furthermore, for both summer and winter seasons ambient lead concentrations were more than four times higher in the industrial area than in the residential areas and in turn, they were higher in the nearby residential area compared with the far-away residential area. As a result, it was suggested that lead emitted from the industrial area would influence more the ambient lead in the nearby residential area than the far-away residential area. Both slag and traffic emissions are likely to be major lead sources in the industrial and nearby residential areas, since their three lead isotope ratios ($^{206}Pb/^{204}Pb$, $^{207}Pb/^{206}Pb$, $^{208}Pb/^{206}Pb$) were similar to the ratios obtained from ambient air of these two areas. In addition, the lead isotope ratios revealed different pattern between seasons, and the ambient lead concentrations were higher for winter than for summer.

Quantitative analysis of cholesterol in infant formula by isotope dilution liquid chromatography-tandem mass spectrometry (동위원소희석 액체크로마토그래피 질량분석법에 의한 분유 내 콜레스테롤의 정량)

  • Ahn, Eun Jeong;Lee, Hwa Shim;Kim, Byung Joo;Lee, Gae Ho
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.460-466
    • /
    • 2015
  • An isotope dilution liquid chromatography tandem mass spectrometry was developed as a primary method for the quantitative analysis of cholesterol in infant formula. Cholesterol-d4 was used as an internal standard and spiked into the infant formula sample. In order to release cholesterol out of cholesteryl ester, which is cholesterol bound to fatty acids in infant formula, saponification was carried out. Saponification conditions were optimized with heating temperature, reaction time and the concentration of KOH. The optimum conditions were as follows; heating temperature was 70 ℃, reaction time was 180 min and the concentration of KOH was 0.8 mL of 8 M KOH for about 0.1 g infant formula sample. Extraction of cholesterol out of sample solution was carried out with hexane uisng liquid-liquid extraction. Chromatographic analysis was carried out using Phenomenex Kinetex C18 column. Mobile phase was 0.1% acetic acid in methanol/water (v/v, 99/1) and flow rate was 0.3 mL/min. Cholesterol and cholesterol-d4 were monitored at mass transfer m/z 369/259 and 373/263 respectively. Reproducibility of the method was evaluated to be 0.23% of the measurement result. The expanded uncertainty of the measurement result of cholesterol in infant formula was approximately 1.9% at a 95% confidence level. NIST standard reference material having certified values of cholesterol in infant formula, was analyzed in order to verify this method. The ID-LC/MS/MS results were well agreed with the certified values of NIST SRM within the uncertainty.

A Study on the Measurement of Half-life for the 179Re Isotope Produced by a 100 MeV Proton Nuclear Reaction (100 MeV 양성자 핵반응에 의해 생성된 179Re 동위원소의 반감기 측정에 관한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.447-453
    • /
    • 2020
  • This study accurately measured the half-life of the 179Re radioactive isotope using the 100 MeV proton and high-purity HPGe gamma ray measurement system generated from a high-energy proton linear accelerator at the Korea Atomic Energy Research Institute. The result obtained is 19.64 ± 0.26 min. Compared with the past results of the half-life of the 179Re radioisotope known to date, the results of B. Harmatz published in 1960 and B. J. Meijer published in 1975 measured the median value higher than the results obtained in this study. In the case of K. J. Hofstetter, published in 1966, a very large error is also characteristic. This result showed a tendency that the center value was very consistent with the result of this study. The results of Coral M. Baglin's 19.5 min published in 2009 are very consistent with the error range. The obtained measured result was compared with the result of ENSDF (Evaluated Nuclear Structure Data File). Through this study, more reliable values were measured for the results of the half-life of the 179Re, which was previously incorrect, and the validity of the recently published results of Coral M. Baglin was confirmed.

Methodological Study on Measurement of Hydrogen Abundance in Hydrogen Isotopes System by Low Resolution Mass Spectrometry

  • Lia, Jin-Ying;Shib, Lei;Hub, Shi-Lin
    • Mass Spectrometry Letters
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • China's rapid economic growth has resulted in significant environmental side effects. Therefore, China has been interested in reducing her dependence on foreign oil and gas by developing technologies needed for hydrogen, in addition to her increasing energy mix of nuclear and renewable energy form, such as solar and wind power. There are three isotopes of hydrogen, i.e. protium (P or H), deuterium (D), and tritium (T). Both deuterium and tritium are important materials in nuclear fuel cycle industry. Tritium is one of the critical radioactive nuclides. Planning for and implementing contamination control as a part of normal operation and maintenance activities is an important function in any hydrogen facility, especially tritium facility. The development of hydrogen isotopes analysis is the key issues in this area. Mass spectrometry (MS) with medium (about 600) and high resolution (> 1,400) is commercially available; however, the routine analysis of hydrogen isotopes is done with low-resolution MS (< 200) in China. This paper summarizes the progress of MS measurement technology for hydrogen isotope abundance in China, focusing on our lab's research program and technical status. An analyzing method has been introduced for accurate measurement of tritium abundance in the H.D.T system by low resolution MAT-253 MS. The quotient of compression ratio coefficient is determined by building up equipment for laboratory-scale preparation of secondary standard gases and by considering the difference in sensitivity between hydrogen isotopes. The results show that the measured value is reproducible within the relative error range of 0.8% for gas samples of different tritium abundance.

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

Introduction of Denitrification Method for Nitrogen and Oxygen Stable Isotopes (δ15N-NO3 and δ18O-NO3) in Nitrate and Case Study for Tracing Nitrogen Source (탈질미생물을 이용한 질산성 질소의 산소 및 질소 동위원소 분석법 소개)

  • Lim, Bo-La;Kim, Min-Seob;Yoon, Suk-Hee;Park, Jaeseon;Park, Hyunwoo;Chung, Hyen-Mi;Choi, Jong-Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.4
    • /
    • pp.459-469
    • /
    • 2017
  • Nitrogen (N) loading from domestic, agricultural and industrial sources can lead to excessive growth of macrophytes or phytoplankton in aquatic environment. Many studies have used stable isotope ratios to identify anthropogenic nitrogen in aquatic systems as a useful method for studying nitrogen cycle. In this study to evaluate the precision and accuracy of denitrification bacteria method (Pseudomonas chlororaphis ssp. Aureofaciens ($ATCC^{(R)}$ 13985)), three reference (IAEA-NO-3 (Potassium nitrate $KNO_3$), USGS34 (Potassium nitrate $KNO_3$), USGS35 (Sodium nitrate $KNO_3$)) were analyzed 5 times repeatedly. Measured the ${\delta}^{15}N-NO_3$ and ${\delta}^{18}O-NO_3$ values of IAEA-NO-3, USGS 34 and USGS35 were ${\delta}^{15}N:4.7{\pm}0.1$${\delta}^{18}O:25.6{\pm}0.5$‰, ${\delta}^{15}N:-1.8{\pm}0.1$${\delta}^{18}O:-27.8{\pm}0.4$‰, and ${\delta}^{15}N:2.7{\pm}0.2$${\delta}^{18}O:57.5{\pm}0.7$‰, respectively, which are within recommended values of analytical uncertainties. Also, we investigated isotope values of potential nitrogen source (soil, synthetic fertilizer and organic-animal manures) and temporal patterns of ${\delta}^{15}N-NO_3$ and ${\delta}^{18}O-NO_3$ values in river samples during from May to December. ${\delta}^{15}N-NO_3$ and ${\delta}^{18}O-NO_3$ values are enriched in December suggesting that organic-animal manures should be one of the main N sources in those areas. The current study clarifies the reliability of denitrification bacteria method and the usefulness of stable isotopic techniques to trace the anthropogenic nitrogen source in freshwater ecosystem.

Observation of Bottom Water Renewal and Export Production in the Japan Basin, East Sea Using Tritium and Helium Isotopes

  • Hahm, Do-Shik;Kim, Kyung-Ryul
    • Ocean Science Journal
    • /
    • v.43 no.1
    • /
    • pp.39-48
    • /
    • 2008
  • Tritium ($^3H$ or T) has been produced mostly by atmospheric nuclear weapon tests, and entered the ocean in the form of water (HTO). As tritium exists as water itself, it has been regarded as an ideal tool to study the transport of water masses. In April 2001 we collected water samples in the western Japan Basin (WJB) for tritium and helium measurement. The timely sampling provided direct evidence of the bottom water formation, resulting in the drastic increase in tritium concentration from 0.3 TU in 2000 to 0.67 TU in 2001. Considering that the new bottom waters were found mostly in the WJB, it implies that maximum 1% of the whole bottom layer below 2600 m should be replaced with the surface water during the severely cold winter 2000 2001. $^3H-^3He$ age, showing the elapsed time since the water left from the surface, can be used to calculate oxygen utilization rate by dividing AOU by the age. Under the condition of 90% oxygen saturation in the surface water, the integration of OUR in the water column below 200 m yields net oxygen consumption of 12 mol $(O_2)m^{-2}yr^{-1}$, which corresponds to the export production of $99\;g\;C\;m^{-2}yr^{-1}$. This estimate is comparable to a previous estimate based on satellite data and implies that the ratio of export to primary production(f-ratio) is as high as 0.5 in the WJB.

Radiation Detection System for Prevention of Illicit Trafficking of Nuclear and Radioactive Materials

  • Kwak, Sung-Woo;Chang, Sung-Soon;Yoo, Ho-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.167-171
    • /
    • 2010
  • Fixed radiation portal monitors (RPMs) deployed at border, seaport, airport and key traffic checkpoints have played an important role in preventing the illicit trafficking and transport of nuclear and radioactive materials. However, the RPM is usually large and heavy and can't easily be moved to different locations. These reasons motivate us to develop a mobile radiation detection system. The objective of this paper is to report our experience on developing the mobile radiation detection system for search and detection of nuclear and radioactive materials during road transport. Field tests to characterize the developed detection system were performed at various speeds and distances between the radioactive isotope (RI) transporting car and the measurement car. Results of measurements and detection limits of our system are described in this paper. The mobile radiation detection system developed should contribute to defending public's health and safety and the environment against nuclear and radiological terrorism by detecting nuclear or radioactive material hidden illegally in a vehicle.