• Title/Summary/Keyword: isotope measurement

Search Result 130, Processing Time 0.021 seconds

ISOTOPIC-SPECTRAL DETERMINATION OF CARBON IN HIGH PURITY INORGANIC MATERIALS

  • Lee, V.N.;Nemets, V.M.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.477-480
    • /
    • 1995
  • Isotopic-spectral method [I] was applicated for determination of carbon in silicate materials (pure silica, guartz glasses, geological probs etc.). Isotopic heterogeneous balancing of carbon in gaseous phase and solid samples was carried out at the temperature of $1500-1900^{\circ}K$. Spectroscopic measuring of isotope concentration in a balanced gas was made using the electron-vibrational band heads of CO molecules excited in HF discharge. Limits of detection of carbon concentrations appear to be $n^*10^{-6}$.

  • PDF

Rapid and Precise Determination of Pb Isotope Ratios Using Mu1ti-Collector ICP/MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 신속하고 정밀한 Pb 동위원소 분석)

  • 최만식;정창식;신형선;임태선
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.157-171
    • /
    • 2001
  • This study investigated the effects of Pb/Tl ratio, Pb concentration and concomitant matrix elements on the measurement of Pb isotope ratios using multi-collector ICP/MS (AXIOM MC model). Accuracy and reproducibility of Pb isotope ratios in NBS 981 solution were estimated for 42 data measured from March to August 2001. Pb isotopes measured in rocks, bronzes and sediments were compared to data measured by TIMS. Reproducibilities for $^{206}Pb/^{204}Pb,\; ^{207}Pb/^{204}Pb,\;and\;^{208}Pb/^{204}Pb$ ratio were about 500 ppm (2sd) and for $^{207}Pb/^{206}Pb$\;and\;^{208}Pb/^{206}Pb$ were 100~200 ppm for 200 ng of Pb in NBS 981 solution. The optimum conditions for the analysis of Pb isotope ratios with AXIOM MC for best accuracy and reproducibility were defined as follows; 1) Pb/Tl ratio is about 10 2) Pb concentration is about 100 ng/ml 3) correction for mass discrimination is performed by exponential law using 2.3887 of $^{205}Tl/^{203}Tl$ and Pb mass fractionation factor empirically obtained from $ln(^{208}Pb/^{206}Pb)-ln(^{205}Tl/^{203}Tl)$ relationship. The sample data measured with MC/ICP/MS for acid-digested and chemically separated rock samples, and acid-digested bronze samples and sediment samples coincide with those of TIMS within analytical errors. Therefore, MC/ICP/MS is a rapid analytical technique for Pb isotope ratios with the similar precision compared with TIMS.

  • PDF

Measurement of oxygen isotope ratio using tunable diode laser absorption spectroscopy (다이오드 레이저 흡수분광법을 이용한 산소 동위원소의 성분비 측정)

  • Park, Sang-Eon;Jung, Do-Young;Kim, Jae-Woo;Ko, Kwang-Hoon;Im, Kwon;Jung, Eui-Chang;Kim, Chul-Joong
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • Tunable diode laser absorption spectroscopy was performed for analysis of the H$_2$$^{18}$ O/H$_2$$^{16}$ O isotope ratio of a water sample which was enriched by the membrane distillation method. In order to improve the signal-to-noise ratio, the wavelength modulation spectroscopic method was used with a lock-in amplifier. The fringe noise could be suppressed by using the FFT (Fast Fourier Transform) lowpass filter and the optimization of the modulation depth of the laser frequency. The maximum deviation of $\delta$-value was measured to be$\pm$4$\textperthousand$.

Measurement of the Rate of Protein Synthesis in Chickens by HPLC/MS

  • Seo, S.S.;Coon, C.
    • Korean Journal of Poultry Science
    • /
    • v.31 no.3
    • /
    • pp.137-143
    • /
    • 2004
  • The fractional synthesis rates(FSR) were measured with 2l-wk and 3l-wk-old broiler breeder pullets and hens to investigate the effect of sexual maturity on FSR. The FSR were obtained from chicken tissues and blood samples using High-Performance Liquid Chromatography/Mass Spectrometry(HPLC/MS). A L-l-13C, 15N -leucine saline solution was infused by bolus injection as a tracer into broiler breeder pullets in the experiment. A rapid HPLC/MS method was developed to measure the isotopic enrichments of leucine in plasma, tissue samples, and eggs. The enrichments of stable isotope leucine incorporated into protein and the enrichments of the stable isotope free leucine were measured in liver, breast muscle and blood samples. Two sets of experiments were conducted. In experiment one, 2l-wk-old, sexually immature broiler breeder pullets were divided into groups of three and blood samples were collected at 20 or 30 min intervals until 1.5 h from initial injection. The pullets were sacrificed in groups of three at varying time intervals for 7 h after injection. The liver, breast muscle and blood samples were removed for analysis. The FSR were estimated to be 8.7l%/day for liver, 4.06%/day for breast muscle, and 5.08%/day for blood samples in 30 minutes after injection from the enrichment ratios. In experiment two, sexually matured 3l-wk-old broiler breeder hens were assorted into groups of three and blood samples were obtained at 20 or 30 min intervals for 2 h. The FSR for blood samples were determined. The broiler breeder hens were sacrificed in groups of three at various time intervals until 7 h after injection and liver, breast muscle and blood samples were removed for analysis. The FSR were calculated to be 5.96%/day for liver. Eggs were collected from five chickens daily for 10 days after large bolus injection. The average of total enrichments of stable isotope in egg albumin was increased by 0.064% at 4 days after injection and was back to normal in 7 days.

Monte Carlo Calculation for Production Cross-Sections of Projectile's Isotopes from Therapeutic Carbon and Helium Ion Beams in Different Materials

  • Quazi Muhammad Rashed Nizam;Asif Ahmed;Iftekhar Ahmed
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.204-212
    • /
    • 2023
  • Background: Isotopes of the projectile may be produced along the beam path during the irradiation of a target by a heavy ion due to inelastic interactions with the media. This study analyzed the production cross-section of carbon (C) and Helium (He) projectile's isotopes resulting from the interactions of these beams with different materials along the beam path. Materials and Methods: In this study, we transport C and He ion beams through different materials. This transportation was made by the Monte Carlo simulation. Particle and Heavy Ion Transport code System (PHITS) has been used for this calculation. Results and Discussion: It has been found that 10C, 11C, and 13C from the 12C ion beam and 3He from the 4He ion beam are significant projectile's isotopes that have higher flux than other isotopes of these projectiles. The 4He ion beam has a higher projectile's isotope production cross-section along the beam path, which adds more impurities to the beam than the 12C ion beam. These projectile's isotopes from both the 12C and 4He ion beams have higher production cross-sections in hydrogenous materials like water or polyethylene. Conclusion: It is important to distinguish these projectile's isotopes from the primary beam particles to obtain a precise and accurate cross-section result by minimizing the error during measurement with a nuclear track detector. This study will show the trend of the production probability of projectile's isotopes for these ion beams.

Raw Material and Provenance of Chosen-Tongbo (I) (조선통보의 주조원료와 산지 연구(I))

  • Kang, Hyung Tae;Kim, Gyu Ho;Huh, Woo Young;Hirao, Yoshimitsu
    • Journal of Conservation Science
    • /
    • v.16 s.16
    • /
    • pp.15-20
    • /
    • 2004
  • Two pieces of choson-Tongue(朝鮮通寶) minted at 1423 A.D. were analyzed by atomic absorption spectroscopy and neutron activation analysis. The measurement of lead isotope ratios was also carried out in order to predict the provenance of raw materials used for minting. The Chosen-Tongue was minted as bronze having the chemical compositions of $Cu\;90\%,\;Pb\;3\~4\%,\;Sn\;2\~3\%$, which were different from the typical composition of Chinese and Japanese coins. The results of lead isotope ratios showed that the provenance of raw materials used for minting had a possibility to be originated from South China. And application of statistical linear discriminant analysis (SLDA) to the provenance of lead used for minting of Chosen-Tongue was confirmed.

  • PDF

Assessment of Organic Matter Sources in the Singil Stream Flowing into Lake Shihwa, South Korea

  • Kim, Dahae;Kim, Jung-Hyun;Kang, Sujin;Kim, Min-Seob;Shin, Kyung-Hoon
    • Korean Journal of Ecology and Environment
    • /
    • v.53 no.2
    • /
    • pp.138-147
    • /
    • 2020
  • The Singil Stream, flowing into an artificial lake, Lake Shihwa (South Korea), experiences a strong anthropogenic pressure with continuous organic matter (OM) inputs from rural, urban, and industrial areas. In this study, we investigated suspended particulate matter (SPM) and streambed sediments collected along the Singil Stream in 2014 and 2016, by applying a dual element approach (δ13C and δ15N) to identify OM sources. The SPM and streambed sediment samples from the indusrial area showed higher organic carbon and nitrogen concentrations (or contents) than those from the other areas, with distinctively lower δ15N values. Accordingly, our dual element approach indicates that the industrial area was the predominant OM source influencing OM quality and thus water quality of the Singil Stream flowing into Lake Shihwa during the study periods. However, further studies are necessary to better constrain OM sources in the Singil Stream since OM sources from the industrial area appear to be complex.

Burnup Measurement of Irradiated Uranium Dioxide Fuel by Chemical Methods (화학적 방법에 의한 핵연료의 연소도 측정)

  • Kim, Jung-Suk;Han, Sun-Ho;Suh, Moo-Yul;Joe, Kih-Soo;Eom, Tae-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.277-286
    • /
    • 1989
  • Destructive methods are used for the turnup determination of an irradiated PWR fuel. One of the methods includes U, Pu, Nd-148 and Nd-(145+146) determination by an isotope dilution mass spectrometry using triple spikes (U-233, Pu-242 and Nd-150). The method involves two sequential ion exchange resin separation procedures. Pu is eluted from the first anion exchange resin column (Dowex AG 1$\times$8) with 12 M HCl-0.1 M HI mixed solution, followed by U elution with 0.1 M HCl. Nd is isolated from other fission products on the second anion exchange resin column (Dowex AG 1$\times$4) with a nitric acid-methanol eluent. Each fraction is analysed by thermal ionization mass spectrometry. The difference between Nd-148 and Nd-(145+146) method is found with an average 2.07%. The results are compared with those by the heavy element method using U and Pu isotopes and by the destructive y-spectrometric measurement of Cs-137. The dependences of isotope composition of U and Pu on burn-up, and correlation between those isotopes are illustrated graphically.

  • PDF

236U accelerator mass spectrometry with a time-of-flight and energy detection system

  • Li Zheng;Hiroyuki Matsuzaki;Takeyasu Yamagata
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4636-4643
    • /
    • 2022
  • A time-of-flight and energy (TOF-E) detection system for the measurement of 236U accelerator mass spectrometry (AMS) has been developed to improve the 236U/238U sensitivity at Micro Analysis Laboratory, Tandem accelerator (MALT), The University of Tokyo. With observing TOF distribution of 235U, 236U and 238U, this TOF-E detection system has clearly separated 236U from the interference of 235U and 238U when measuring three kinds of uranium standards. In addition, we have developed a novel method combining kernel-based density estimation method and multi-Gaussian fitting method to estimate the 236U/238U sensitivity of the TOF-E detection system. Using this new estimation method, 3.4 × 10-12 of 236U/238U sensitivity and 1.9 ns of time resolution are obtained. 236U/238U sensitivity of TOF-E detection system has improved two orders of magnitude better than that of previous gas ionization chamber. Moreover, unknown species other than uranium isotopes were also observed in the measurement of a surface soil sample, which has demonstrated that TOF-E detection system has a higher sensitivity in particle identification. With its high sensibility in mass determination, this TOF-E detection system could also be used in other heavy isotope AMS.

MEASUREMENT OF $^{235}U$ ENRICHMENT USING THE SEMI-PEAK-RATIO TECHNIQUE WITH CdZnTe GAMMA-RAY DETECTOR

  • Ha, J.H.;Ko, W.I.;Lee, S.Y.;Song, D.Y.;Kim, H.D.;Yang, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.275-279
    • /
    • 2001
  • In uranium enrichment plants and nuclear fuel fabrication facilities, exact measurement of fissile isotope enrichment of uranium is required for material accounting in international safeguards inspection as well as process quality control. The purpose of this study was to develop a simple measurement system which can portably be used at nuclear fuel fabrication plants especially dealing with low enriched uranium. For this purpose, a small size CZT (CdZnTe) detector was used, and the detector performance in low uranium gamma/X -rays energy range was investigated by use of various enriched uranium oxide samples. New enrichment measurement technique and analysis method for low enriched uranium oxide, so-called, 'semi-peak ratio technique' was developed. The newly developed method was considered as an alternative technique for the low enrichment and would be useful to account nuclear material in safeguarding activity at nuclear fuel fabrication facility.

  • PDF