• Title/Summary/Keyword: isothermal amplification

Search Result 111, Processing Time 0.028 seconds

Loop-Mediated Isothermal Amplification Targeting Actin DNA of Trichomonas vaginalis

  • Goo, Youn-Kyoung;Shin, Won-Sik;Yang, Hye-Won;Joo, So-Young;Song, Su-Min;Ryu, Jae-Sook;Kong, Hyun-Hee;Lee, Won-Ki;Chung, Dong-Il;Hong, Yeonchul
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.3
    • /
    • pp.329-334
    • /
    • 2016
  • Trichomoniasis caused by Trichomonas vaginalis is a common sexually transmitted disease. Its association with several health problems, including preterm birth, pelvic inflammatory disease, cervical cancer, and transmission of human immunodeficiency virus, emphasizes the importance of improved access to early and accurate detection of T. vaginalis. In this study, a rapid and efficient loop-mediated isothermal amplification-based method for the detection of T. vaginalis was developed and validated, using vaginal swab specimens from subjects suspected to have trichomoniasis. The LAMP assay targeting the actin gene was highly sensitive with detection limits of 1 trichomonad and 1 pg of T. vaginalis DNA per reaction, and specifically amplified the target gene only from T. vaginalis. Validation of this assay showed that it had the highest sensitivity and better agreement with PCR (used as the gold standard) compared to microscopy and multiplex PCR. This study showed that the LAMP assay, targeting the actin gene, could be used to diagnose early infections of T. vaginalis. Thus, we have provided an alternative molecular diagnostic tool and a point-of-care test that may help to prevent trichomoniasis transmission and associated complications.

Rapid and Efficient Detection of 16SrI Group Areca Palm Yellow Leaf Phytoplasma in China by Loop-Mediated Isothermal Amplification

  • Yu, Shao-shuai;Che, Hai-yan;Wang, Sheng-jie;Lin, Cai-li;Lin, Ming-xing;Song, Wei-wei;Tang, Qing-hua;Yan, Wei;Qin, Wei-quan
    • The Plant Pathology Journal
    • /
    • v.36 no.5
    • /
    • pp.459-467
    • /
    • 2020
  • Areca palm yellow leaf (AYL) disease caused by the 16SrI group phytoplasma is a serious threat to the development of the Areca palm industry in China. The 16S rRNA gene sequence was utilized to establish a rapid and efficient detection system efficient for the 16SrI-B subgroup AYL phytoplasma in China by loop-mediated isothermal amplification (LAMP). The results showed that two sets of LAMP detection primers, 16SrDNA-2 and 16SrDNA-3, were efficient for 16SrI-B subgroup AYL phytoplasma in China, with positive results appearing under reaction conditions of 64℃ for 40 min. The lowest detection limit for the two LAMP detection assays was the same at 200 ag/μl, namely approximately 53 copies/μl of the target fragments. Phytoplasma was detected in all AYL disease samples from Baoting, Tunchang, and Wanning counties in Hainan province using the two sets of LAMP primers 16SrDNA-2 and 16SrDNA-3, whereas no phytoplasma was detected in the negative control. The LAMP method established in this study with comparatively high sensitivity and stability, provides reliable results that could be visually detected, making it suitable for application and research in rapid diagnosis of AYL disease, detection of seedlings with the pathogen and breeding of disease-resistant Areca palm varieties.

Reverse transcription loop-mediated isothermal amplification assay for the rapid and simultaneous detection of H5 and other subtypes of avian influenza viruses

  • Park, Yu-Ri;Kim, Eun-Mi;Han, Do-Hyun;Kang, Dae-Young;Yeo, Sang-Geon;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.40 no.1
    • /
    • pp.15-20
    • /
    • 2017
  • A two-tube reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was designed for the rapid visual detection of the M gene of all subtypes of avian influenza virus (AIV) and the H5 gene of the H5 subtype of highly pathogenic AIV (HPAIV). The reaction carried out in two tubes in a single step at $58^{\circ}C$ for 40 min, and the assay results could be visually detected by using hydroxynaphthol blue dye. Using M or H5 gene-specific primers, the assay successfully detected all subtypes or H5 subtypes of AIVs, including the Korean representative H5N1 and H5N8 HPAIVs. The detection limit of the assay was approximately $10^{2.0}$ $EID_{50}/reaction$ for the M and H5 genes of H5N1 HPAIV, respectively, and was more sensitive than that of previously reported RT-LAMP and comparable to that of real-time RT-PCR. These results suggest that the present RT-LAMP assay, with its high specificity, sensitivity, and simplicity, will be a useful diagnostic tool for surveillance of currently circulating H5 HPAIVs and other subtypes of AIV in bird population, even in under-equipped laboratories.

Detection of Clostridium difficile by Loop-Mediated Isothermal Amplification (등온증폭법을 이용한 Clostridium difficile 검출)

  • In, Ye-Won;Ha, Su-Jeong;Yang, Seung-Kuk;Oh, Se-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.9
    • /
    • pp.1326-1330
    • /
    • 2012
  • This study was conducted to develop a loop-mediated isothermal amplification (LAMP) method for the detection of Clostridium difficile. The tested target gene was 16S ribosomal RNA. Five different LAMP primer sets were designed, and LAMP was performed. All primer sets targeting the 16S rRNA gene (BIP, FIP, B3, F3, LF, PF) were determined as positive in tcdA-positive, tcdB-postive ($A^+B^+$) and tcdA-negative, tcdB-negative ($A^-B^-$) Clostridium difficile strains. As the LAMP reaction took less than 80 min and did not require expensive machine such as thermocycler, it can be used as a rapid and simple detection method for foodborne pathogens.

Loop-Mediated Isothermal Amplification Assay Targeting the femA Gene for Rapid Detection of Staphylococcus aureus from Clinical and Food Samples

  • Zhao, Xihong;Li, Yanmei;Park, Myoungsu;Wang, Jun;Zhang, Youhong;He, Xiaowei;Forghani, Fereidoun;Wang, Li;Yu, Guangchao;Oh, Deog-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.2
    • /
    • pp.246-250
    • /
    • 2013
  • In this study, a loop-mediated isothermal amplification (LAMP) method to rapidly detect Staphylococcus aureus strains was developed and evaluated by extensively applying a large number of S. aureus isolates from clinical and food samples. Six primers were specially designed for recognizing eight distinct sequences on the species-specific femA gene of S. aureus. The detection limits were 100 fg DNA/tube and $10^4$ CFU/ml. The LAMP assay was applied to 432 S. aureus strains isolated from 118 clinical and 314 food samples. Total detection rates for the LAMP and polymerase chain reaction assays were 98.4% (306/311) and 89.4% (278/311), respectively.

Development of a diagnostic method for human enteric Adenovirus-41 with rapid, specific and high sensitivity using the loop-mediated isothermal amplification assay

  • Lee, Jin-Young;Rho, Jae Young
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.673-681
    • /
    • 2020
  • Human enteric Adenovirus 41 (HueAdV-41) is a major waterborne virus that causes human gastroenteritis and is classified as a viral group I double-strand DNA virus, Adenoviridae. HueAdV-41 has been detected with the polymerase chain reaction (PCR) in various samples such as ground water. However, the PCR-based diagnostic method has problems such as reaction time, sensitivity, and specificity. Thus, the loop-mediated isothermal amplification (LAMP) assay has emerged as an excellent method for field applications. In this study, we developed a LAMP system that can rapidly detect HueAdV-41 with high specificity and sensitivity. HueAdV-41 specific LAMP primer sets were tested through a specific, non-specific selection and sensitivity test for three prepared LAMP primer sets, of which only one primer set and optimum reaction temperature were selected. The developed LAMP primer set condition was confirmed as 63℃, and the sensitivity was 1 copy. In addition, to confirm the system, a LAMP positive reaction was developed with the restriction enzyme Taq I (T/GCC). The developed method in this study was more specific, rapid (typically within 2 - 3 hours), and highly sensitive than that of the conventional PCR method. To evaluate and verify the developed LAMP assay, an artificial infection test was done with five cDNAs from groundwater samples, and the results were compared to those of the conventional PCR method. We expect the developed LAMP primer set will be used to diagnose HueAdV-41 from various samples.

Rapid, Sensitive, and Specific Detection of Clostridium tetani by Loop-Mediated Isothermal Amplification Assay

  • Jiang, Dongneng;Pu, Xiaoyun;Wu, Jiehong;Li, Meng;Liu, Ping
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • Tetanus is a specific infectious disease, which is often associated with catastrophic events such as earthquakes, traumas, and war wounds. The obligate anaerobe Clostridium tetani is the pathogen that causes tetanus. Once the infection of tetanus progresses to an advanced stage within the wounds of limbs, the rates of amputation and mortality increase manifold. Therefore, it is necessary to devise a rapid and sensitive point-of-care detection method for C. tetani so as to ensure an early diagnosis and clinical treatment of tetanus. In this study, we developed a detection method for C. tetani using loop-mediated isothermal amplification (LAMP) assay, wherein the C. tetani tetanus toxin gene was used as the target gene. The method was highly specific and sensitive, with a detection limit of 10 colony forming units (CFU)/ml, and allowed quantitative analysis. While detecting C. tetani in clinical samples, it was found that the LAMP results completely agreed with those of the traditional API 20A anaerobic bacteria identification test. As compared with the traditional API test and PCR assay, LAMP detection of C. tetani is simple and rapid, and the results can be identified through naked-eye observation. Therefore, it is an ideal and rapid point-of-care testing method for tetanus.

Diagnostic Method for the Detection of JC Polyomavirus Using Loop-mediated Isothermal Amplification (등온증폭법을 이용한 고감도 JC polyomaviruses 진단법 개발)

  • Cho, Kyu Bong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.414-419
    • /
    • 2019
  • JC polyomavirus (JCPyV) is a human pathogenic virus belonging to the family Polyomaviridae, a viral group containing dsDNA nucleic acid. A recent recommendation is to apply the presence of JCPyV as a fecal indicator for water contamination in environments like sewage, and techniques to monitor JCPyV in water are being proposed. To date, the conventional PCR system has been applied as a diagnostic method for detecting JCPyV. There is a need for a more rapid and sensitive JCPyV diagnostic detection method in clinical and environmental samples. In this study, we developed a loop-mediated isothermal amplification (LAMP) primer set for the detection of JCPyV. Our results indicate that the LAMP method using a specific primer set shows about 10-fold higher detection sensitivity than the conventional PCR system. The effectiveness of the LAMP method developed in this study has been validated by PCR product digestion using the HaeIII restriction enzyme. We, therefore, propose that the LAMP method using a specific primer set can be applied as a rapid and sensitive detection method for monitoring JCPyV in clinical and environmental samples.

Rapid and Visual Detection of Vibrio parahaemolyticus in Aquatic Foods Using blaCARB-17 Gene-Based Loop-Mediated Isothermal Amplification with Lateral Flow Dipstick (LAMP-LFD)

  • Hu, Yuan-qing;Huang, Xian-hui;Guo, Li-qing;Shen, Zi-chen;LV, Lin-xue;Li, Feng-xia;Zhou, Zan-hu;Zhang, Dan-feng
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.12
    • /
    • pp.1672-1683
    • /
    • 2021
  • Vibrio parahaemolyticus is recognized as one of the most important foodborne pathogens responsible for gastroenteritis in humans. The blaCARB-17 gene is an intrinsic β-lactamase gene and a novel species-specific genetic marker of V. parahaemolyticus. In this study, a loop-mediated isothermal amplification (LAMP) assay combined with a lateral flow dipstick (LFD) was developed targeting this blaCARB-17 gene. The specificity of LAMP-LFD was ascertained by detecting V. parahaemolyticus ATCC 17802 and seven other non-V. parahaemolyticus strains. Finally, the practicability of LAMP-LFD was confirmed by detection with V. parahaemolyticus-contaminated samples and natural food samples. The results showed that the optimized reaction parameters of LAMP are as follows: 2.4 mmol/l Mg2+, 0.96 mmol/l dNTPs, 4.8 U Bst DNA polymerase, and an 8:1 ratio of inner primer to outer primer, at 63℃ for 40 min. The optimized reaction time of the LFD assay is 60 min. Cross-reactivity analysis with the seven non-V. parahaemolyticus strains showed that LAMP-LFD was exclusively specific for V. parahaemolyticus. The detection limit of LAMP-LFD for V. parahaemolyticus genomic DNA was 2.1 × 10-4 ng/μl, corresponding to 630 fg/reaction and displaying a sensitivity that is 100-fold higher than that of conventional PCR. LAMP-LFD in a spiking study revealed a detection limit of approximately 6 CFU/ml, which was similar with conventional PCR. The developed LAMP-LFD specifically identified the 10 V. parahaemolyticus isolates from 30 seafood samples, suggesting that this LAMP-LFD may be a suitable diagnostic method for detecting V. parahaemolyticus in aquatic foods.

Development of a ladder-shape melting temperature isothermal amplification (LMTIA) assay for detection of African swine fever virus (ASFV)

  • Wang, Yongzhen;Wang, Borui;Xu, Dandan;Zhang, Meng;Zhang, Xiaohua;Wang, Deguo
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.51.1-51.10
    • /
    • 2022
  • Background: Due to the unavailability of an effective vaccine or antiviral drug against the African swine fever virus (ASFV), rapid diagnosis methods are needed to prevent highly contagious African swine fever. Objectives: The objective of this study was to establish the ladder-shape melting temperature isothermal amplification (LMTIA) assay for the detection of ASFV. Methods: LMTIA primers were designed with the p72 gene of ASFV as the target, and plasmid pUC57 was used to clone the gene. The LMTIA reaction system was optimized with the plasmid as the positive control, and the performance of the LMTIA assay was compared with that of the commercial real-time polymerase chain reaction (PCR) kit in terms of sensitivity and detection rate using 200 serum samples. Results: Our results showed that the LMTIA assay could detect the 104 dilution of DNA extracted from the positive reference serum sample, which was the same as that of the commercial real-time PCR kit. The coincidence rate between the two assays was 100%. Conclusions: The LMTIA assay had high sensitivity, good detection, and simple operation. Thus, it is suitable for facilitating preliminary and cost-effective surveillance for the prevention and control of ASFV.