• Title/Summary/Keyword: isolation systems

Search Result 783, Processing Time 0.032 seconds

Fault Diagnosis for the Nuclear PWR Steam Generator Using Neural Network (신경회로망을 이용한 원전 PWR 증기발생기의 고장진단)

  • Lee, In-Soo;Yoo, Chul-Jong;Kim, Kyung-Youn
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.6
    • /
    • pp.673-681
    • /
    • 2005
  • As it is the most important to make sure security and reliability for nuclear Power Plant, it's considered the most crucial issues to develop a fault detective and diagnostic system in spite of multiple hardware redundancy in itself. To develop an algorithm for a fault diagnosis in the nuclear PWR steam generator, this paper proposes a method based on ART2(adaptive resonance theory 2) neural network that senses and classifies troubles occurred in the system. The fault diagnosis system consists of fault detective part to sense occurred troubles, parameter estimation part to identify changed system parameters and fault classification part to understand types of troubles occurred. The fault classification part Is composed of a fault classifier that uses ART2 neural network. The Performance of the proposed fault diagnosis a18orithm was corroborated by applying in the steam generator.

A Feasible Condition for EDF-based Scheduling of Periodic Messages on a Synchronized Switched Ethernet (동기식 스위칭 이더넷에서 주기적 메시지에 대한 마감시간우선 기반 메시지 스케쥴링을 위한 조건)

  • Kim, Myung-Kyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.4
    • /
    • pp.403-410
    • /
    • 2010
  • The switched Ethernet has many features for real-time communications such as providing traffic isolation, large bandwidth, and full-duplex links, and so on. The switched Ethernet, however, cannot guarantee the timely delivery of a real-time message because message delay increases when collisions occurs at the output ports and message loss can even occur due to the overflow at the output buffer. Recently, many research efforts have been done to use the switched Ethernet as an industrial control network. In the industrial control network, sensors periodically sense the physical environment and transmit the sensed data to an actuator, and the periodic messages from sensors to actuators have typically real-time requirements such that those messages must be transmitted within their deadlines. This paper first suggests a feasible condition for EDF (Earliest Deadline First)-based scheduling of periodic messages on a synchronized switched Ethernet and a message scheduling algorithm which satisfies the proposed feasible condition. Pedreiras, et al. [10] suggested a feasible condition for message scheduling on the Ethernet (shared media Ethernet), but there has been no research result on the scheduling condition on the switched Ethernet until now. We compared the real-time message scheduling capacity between the Ethernet and the switched Ethernet by simulation. The simulation result shows that the message scheduling capacity of the Ethernet has almost remained constant as the number of nodes on the network increases, but, in the case of the switched Ethernet, the message scheduling capacity has increased linearly according to the number of nodes on the network.

Development of a Duplexer Module for Remote Wireless Communication System of Guided Weapon System with Temperature-Insensitive Electrical Performances (온도변화에 둔감한 전기적 특성을 가지는 유도무기체계 원격무선통신시스템용 듀플렉서 모듈 개발)

  • Choi, Byung-Chang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.709-716
    • /
    • 2016
  • In this paper, A duplexer module with temperature-insensitive electrical characteristics was proposed for remote wireless communication system. Duplexer modules are required to have performances of low insertion loss, high isolation between transmitted band and received band, harmonic suppression as well as high power durability in the system for transmitting guided information to missile flying a free space on the ground. The proposed duplexer module are consist of transmission bandpass filter and receiving bandpass filter which are connected to common antenna port, planar coupler for output power monitoring and low pass filter for harmonic attenuation of power amplifier and coaxial cavity resonator. The material and dimensions of the resonator are determined for minimum frequency shift by temperature variation using 3D EM simulation. The measured results of the prototype showed a good agreement with the simulation results, and it should be well applied not only for guided weapon systems but also for any other communication systems such as remote radio head.

Study on the improvement in Cv of a Main Oxidizer shut-off Valve (CC 산화제 개폐밸브 유량계수 향상에 관한 연구)

  • Hong, Moon-Geun
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.140-148
    • /
    • 2009
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, in the steady operational state, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the combustion chamber. Concerning the development of MOV, TM(Technology Model) has been manufactured and normal operations of the valve have been verified. However, the Cv of TM has been proved to be too low as compared with a design specification value. Therefore, CFD analysis have been performed by modification of the configurations of TM in order to increase sufficiently Cv of EM(Engineering Model), which is the following model of TM. The modifications of TM configurations such as partial scale-up of valve, increase of stroke length, and outlet angle of 120o would result in a considerable augmentation of Cv. It has been verified by flow capacity tests that the improved Cv of EM is min. 212, which is higher than Cv of TM, 161 by about 32%.

  • PDF

A report of 39 unrecorded bacterial species in Korea belonging to the classes Betaproteobacteria and Gammaproteobacteria isolated in 2018

  • Kim, Yong-Seok;Yi, Hana;Kim, Myung Kyum;Seong, Chi-Nam;Kim, Wonyong;Jeon, Che Ok;Kim, Seung-Bum;Im, Wan-Taek;Joh, Kiseong;Cha, Chang-Jun
    • Journal of Species Research
    • /
    • v.9 no.4
    • /
    • pp.346-361
    • /
    • 2020
  • In the project of a comprehensive investigation of indigenous prokaryotic species in Korea, a total of 39 bacterial strains phylogenetically belonging to the classes Betaproteobacteria and Gammaproteobacteria were isolated from various environmental sources such as soil, cultivated soil, sludge, seawater, marine sediment, algae, human, tree, moss, tidal flat, beach sand and lagoon. Phylogenetic analysis based on 16S rRNA gene sequences revealed that 39 strains showed the high sequence similarities (≥98.7%) to the closest type strains and formed robust phylogenetic clades with closely related species in the classes Betaproteobacteria and Gammaproteobacteria. In the present study, we report 14 species of 9 genera of four families of two orders in the class Betaproteobacteria and 25 species of 21 genera of 15 families of eight orders in the class Gammaproteobacteria, which have not been reported in Korea. Morphological, biochemical, and physiological characteristics, isolation sources, and NIBR deposit numbers are described in the species descriptions.

Identification of 3'-Hydroxymelanetin and Liquiritigenin as Akt Protein Kinase Inhibitors

  • Yang Hye-Young;Lee Hong-Sub;Ko Jong-Hee;Yeon Seung-Woo;Kim Tae-Yong;Hwang Bang-Yeon;Kang Sang-Sun;Chun Jae-Sun;Hong Soon-Kwang
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.9
    • /
    • pp.1384-1391
    • /
    • 2006
  • The signal transduction system is one of the most important devices involved in maintaining life, and many protein kinases are included in the cellular signal transduction system. Finding a protein kinase inhibitor is very valuable, as it can be used to study cell biology and applied to pharmaceuticals. For the efficient and rapid screening of protein kinase inhibitors, two assay systems were combined; the nonradioactive protein kinase assay system that uses an FITC-labeled IRS-2 peptide and the cell-based paper disc assay system that uses Streptomyces griseus as the indicator strain. Among 330 kinds of herb extracts tested, the extract of Dalbergia odorifera exhibited the strongest inhibitory activity in the two assay systems and was selected for further isolation. Based on solvent extraction and many steps of chromatography, seven compounds were finally separated to homogeneity and their structures determined by $^{1}H$ and $^{13}C$ NMR spectroscopies. Four were to be flavonoids and identified as butin ($C_{15}H_{12}O_5$, Mw=272.07), 3'-hydroxymelanetin ($C_{16}H_{12}O_6$, Mw=300.06), liquiritigenin ($C_{15}H_{12}O_4$, Mw=256.07), and 2'-hydroxyformononetin ($C_{16}H_{12}O_{5}$, Mw=284.07). 3'-Hydroxymelanetin inhibited the phosphorylation of the GSK3 protein by Akt to 37% at a concentration of $10{\mu}g/ml$ and showed the strongest cytotoxicity ($ED_{50}<50{\mu}g/ml$) against the human cancer cell line HCT116. Under the same conditions, liquiritigenin also inhibited the phosphorylation of GSK3 by Akt to 26%, and its cytotoxicity against the HCT116 cell line was lower than $100{\mu}g/ml$.

A Study on The Safety Management of City Gas Pipelines Attached on the Bridges (교량에 설치된 도시가스배관의 안전관리에 관한 연구)

  • Yun, Young-Man;Son, Sang-Geun;Choi, Do-Kyun;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.45-52
    • /
    • 2018
  • In this study, 398 city gas pipe systems installed on the bridges were surveyed and analyzed classified characteristics about the ages, length, and remote isolation devices installed or not. As a result of analysis, 43.0% pipes have been used more than 20 years and 89.4% do not have remote cut-off devices, so this study suggest safety management ways for the issues. Chosen 76 pipes were researched stress strain characteristics by CAESAR-II which is a specialized program for stress analysis. And, when a loop is installed on the bridge pipe, effect on code stress by the location and size of the loop was performed. This study can help to improve safety level by revising criteria of new installation, inspection and diagnostic.

A Study on the Characteristic Analysis of Implemented Baseband AIN MIM Capacitor for Wireless PANs & Mobile Communication (무선PAN 및 이동통신용 기저대역 AIN MIM Capacitor의 구현과 특성분석에 관한 연구)

  • Lee, Jong-Joo;Kim, Eung-Kwon;Cha, Jae-Sang;Kim, Jin-Young;Kim, Young-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.5
    • /
    • pp.97-105
    • /
    • 2008
  • The micro capacitors are passive elements necessary to electronic circuits and wireless portable PAN(personal area network) and Mobile Communications device modules in the baseband circuits in combination with another passive and active devices. As capacitance is proportionally increased with dielectric constant and electrode areas, in addition, inversely decreased the thickness of the dielectric material, thus thin film capacitors are generally seen as a preferable means to achieve high performance and thin film capacitors are used in a variety of functional circuit devices. In this paper, propose dielectric material as AIN(Aluminium nitride) to make micro thin film capacitor, and this capacitor has the MIM(metal-insulator-metal) structure. AIN thin films are widespread applied because they had more excellent properties such as chemical stability, high thermal conductivity, electrical isolation and so on. In addition, AIN films show low frequency response for baseband signal ranges, I-V and C-V electrical characterization of a thin film micro capacitor. The above experimental test and estimated results demonstrate that the thin film capacitor has sufficient and efficient functional performance to be the baseband range frequency of general electronics circuit and passive device applications.

  • PDF

Isolation, Identification and Enzymatic Activity of Halotolerant and Halophilic Fungi from the Great Sebkha of Oran in Northwestern of Algeria

  • Chamekh, Rajaa;Deniel, Franck;Donot, Christelle;Jany, Jean-Luc;Nodet, Patrice;Belabid, Lakhder
    • Mycobiology
    • /
    • v.47 no.2
    • /
    • pp.230-241
    • /
    • 2019
  • The Great Sebkha of Oran is a closed depression located in northwestern of Algeria. Despite the ranking of this sebkha among the wetlands of global importance by Ramsar Convention in 2002, no studies on the fungal community in this area have been carried out. In our study, samples were collected from two different regions. The first region is characterized by halophilic vegetation and cereal crops and the second by a total absence of vegetation. The isolated strains were identified morphologically then by molecular analysis. The biotechnological interest of the strains was evaluated by testing their ability to grow at different concentration of NaCl and to produce extracellular enzymes (i.e., lipase, amylase, protease, and cellulase) on solid medium. The results showed that the soil of sebkha is alkaline, with the exception of the soil of cereal crops that is neutral, and extremely saline. In this work, the species Gymnoascus halophilus, Trichoderma gamsii, the two phytopathogenic fungi, Fusarium brachygibbosum and Penicillium allii, and the teleomorphic form of P. longicatenatum observed for the first time in this species, were isolated for the first time in Algeria. The halotolerance test revealed that the majority of the isolated are halotolerant. Wallemia sp. and two strains of G. halophilus are the only obligate halophilic strains. All strains are capable to secrete at least one of the four tested enzymes. The most interesting species presenting the highest enzymatic index were Aspergillus sp. strain A4, Chaetomium sp. strain H1, P. vinaceum, G. halophilus, Wallemia sp. and Ustilago cynodontis.

Assessment of Covid-19 Response of the Medical Institutions Based on ISO Public Service Quality Management Framework (ISO 기반 공공서비스 품질관리 프레임워크를 바탕으로 한 의료기관의 COVID-19 대응 현황 평가)

  • Pyun, Jebum;Kim, Seungbeom
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.6
    • /
    • pp.69-84
    • /
    • 2020
  • This study is conducted to improve the quality of healthcare services responding to COVID-19 by applying the public service quality management framework that is developed from ISO18091:2019 by the Ministry of the Interior and Safety of South Korea. The COVID-19 pandemic has been impacting the world since early 2020, and now in November 2020, it still has not been eliminated. The Korean medical institutions were able to prevent the spread of COVID-19 by agile test and strict cohort isolation. As a result, the so-called K-medical defense has achieved a positive reputation from around the world. In this study, we check and evaluate the current status of the COVID-19 response targeting some Korean hospitals by applying a quality control checklist based on the public service quality management framework. Status of 7 categories are analyzed based on the interview with 3 medical institutions. We also suggest improvements for better medical service quality in case of COVID-19 being prolonged.