• Title/Summary/Keyword: isolation systems

Search Result 783, Processing Time 0.026 seconds

Parity Space and Pattern Recognition Approach for Hardware Redundant System Signal Validation using Artificial Neural Networks (인공신경망을 이용하여 하드웨어 다중 센서 신호 검증을 위한 패리티 공간 및 패턴인식 방법)

  • 윤태섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.6
    • /
    • pp.765-771
    • /
    • 1998
  • An artificial neural network(NN) technique is developed for hardware redundant sensor validation. Since the measurement space is a continuous space with many operating regions, it is difficult to train a NN to correctly detect failure in an accurate measurement system. A conventional backpropagation NN is modified to include an additional preprocessing layer that extracts classification features from scalar measurements. This feature extraction means transform the measurement space to parity space. The NN is independent of the state variable being measured, the instrument range, and the signal tolerance. This NN resembles the parity space approach to signal validation, except that analytical parity equations are unneeded and the NN pattern recognition capability is utilized for decision making.

  • PDF

Methodology on Improving Vibration Characteristics of Servo Write Fixture (서보라이트 픽스쳐의 진동 특성 개선 방법)

  • Yoon, Tae-Yong;Ku, C.P. Roger;Hanlon, Andrew K.;Taylor, Charles L.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.2
    • /
    • pp.47-52
    • /
    • 2011
  • This paper presents a method to improve vibration characteristics of servo track write (STW) fixture. STW fixtures supported by flexible mounts are subject to various vibration sources. Using Finite element analysis (FEA) vibration modes of the fixture are identified. The FEA results suggest certain vibration modes be reduced through design change of flexible mounts to improve vibration responses of the fixture. Based on layered flexible mounts theory a parametric study on shear and bending stiffness is performed to obtain a suitable flexible mount design leading to increased resistance to rocking motion. Experiments confirm improvement of vibration characteristics and drive performance through new mounts design.

Comparison of Reproductive Modes in Populations of Potentilla freyniana

  • Huh, Man-Kyu
    • Journal of Ecology and Environment
    • /
    • v.30 no.3
    • /
    • pp.225-229
    • /
    • 2007
  • The mating systems of natural populations of Potentilla freyniana in Korea were determined using allozyme analysis. The result suggests that P. freyniana is outcrossing as well as employing vegetative reproduction by stolon (self-fertilization rate, s < 0.5). The values of the inbreeding coefficient of eight populations in Korea varied from 0.244 to 0.331, with an average value of 0.274. For eight natural populations, multi-locus estimates of outcrossing (tm) was 0.603 across 13 polymorphic loci, with individual population values ranging from 0.530 to 0.652. The relatively low outcrossing rates of some populations could be attributed to extensive vegetative reproduction by stolon and the isolation of flowering mature plants. Although P. freyniana usually propagated by asexually-produced ramets, I could not rule out the possibility that sexual reproduction occurred at a low rate because each ramet may produce terminal flowers. Although heterozygote excess was observed in some natural populations, most populations exhibited varying degrees of inbreeding and a heterozygote deficit.

A Research on the Solution of the Potential Interferences of Isolation Grounding Systems (독립접지방식의 전위간섭 문제 해결을 위한 연구)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Kil, Hyung-Jun;Han, Woon-Ki;Kim, Hyo-Jin;Lee, Hyung-Kyon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.49-51
    • /
    • 2005
  • This paper presents the potential interferences in various grounding electrode systems. The ground potential rise and potential interference coefficients were calculated as a function of the configuration and size of grounding electrodes and the distance between grounding electrodes. The potential rise and potential interference coefficient strongly depend on the distance between grounding electrodes, the shape and size of grounding electrodes.

  • PDF

Vibration control of hysteretic base-isolated structures: an LMI approach

  • Pozo, Francesc;Pujol, Gisela;Acho, Leonardo
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.195-208
    • /
    • 2016
  • Seismic isolation systems are essentially designed to preserve structural safety, prevent occupants injury and properties damage. An active saturated LMI-based control design is proposed to attenuate seismic disturbances in base-isolated structures under saturation actuators. Using a mathematical model of an eight-storied building structure, an active control algorithm is designed. Performance evaluation of the controller is carried out in a simplified model version of a benchmark building system, which is recognized as a state-of-the-art model for numerical experiments of structures under seismic perturbations. Experimental results show that the proposed algorithm is robust with respect to model and seismic perturbations. Finally, the performance indices show that the proposed controller behaves satisfactorily and with a reasonable control effort.

A Realization of Reduced-Order Detection Filters

  • Kim, Yong-Min;Park, Jae-Hong
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.1
    • /
    • pp.142-148
    • /
    • 2008
  • In this paper, we deal with the problem of reducing the order of the detection filter for the linear time-invariant system. Even if the detection filter is generally designed in the form of full order linear observer, we show that it is possible to reduce its order when the response of fault signals is limited to a subspace of the estimation state space. We propose a method to extract the subspace using the observer canonical form considering the dynamics related to the remaining subspace acts as a disturbance. We designed a reduced order detection filter to reject the disturbance as well as to guarantee fault detection and isolation. A simulation result for a 5th order system is presented as an illustrative example of the proposed design method.

Identification of Fuzzy Dynamic Model for Fault Diagnosis of Nonlinear System (비선형계통 고장진단을 위한 온-라인 퍼지동적모델 식별)

  • 이종렬;배상욱;이기상;박귀태
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.204-210
    • /
    • 1998
  • This paper discusses an on-line fuzzy dynamic model(FDM) identification of nonlinear processes for the design of fuzzy model based fault detection and isolation(FDI). The dynamic behavior of a nonlinear process is represented by a fuzzy aggregation of a set of local linear models. The identification is divided into two procedures. The first is the off-line identification of membership function. The second is the on-line identification of the local linear models. Then, we propose a residual generation scheme based on the parameters of local linear models and show that the scheme can be used for the design of FDI

  • PDF

Damage identification of isolators in base-isolated torsionally coupled buildings

  • Wang, Jer-Fu;Huang, Ming-Chih;Lin, Chi-Chang;Lin, Tzu-Kang
    • Smart Structures and Systems
    • /
    • v.11 no.4
    • /
    • pp.387-410
    • /
    • 2013
  • This paper deals with the damage assessment for isolators of base-isolated building systems considering the torsion-coupling (TC) effect by establishing damage indices. The damage indices can indicate the reduction in lateral stiffness of the isolator story as explicit formulas in terms of modal parameters. In addition, the damage location, expressed in terms of the estimated damage index and eccentricities before and after damage, is also presented. Numerical analysis shows that the proposed algorithms are applicable for general base-isolated multi-story TC buildings. A procedure from the analysis of seismic response to the implementation of damage indices is demonstrated by using a numerical case. A system identification technique is employed to extract modal parameters from seismic responses of a building. Results show that the proposed indices are capable of detecting the occurrence of damage and preliminarily estimating the location of damaged isolator.

A Single-Pole, Eight-Throw, Radio-Frequency, MicroElectroMechanical Systems Switch for Multi-Band / Multi-Mode Front-End Module

  • Kang, Sung-Chan;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.77-81
    • /
    • 2011
  • This paper presents a single-pole eight-throw(SP8T) switch based on proposed a radio-frequency(RF) microelectromechanical systems (MEMS) switches. The proposed switch was driven by a double stop(DS) comb drive, with a lateral resistive contact. Additionally, the proposed switch was designed to have tapered signal line and bi-directionally actuated. A forward actuation connects between signal lines and contact part, and the output becomes on-state. A reverse actuation connects between ground lines and contact part, and the output becomes off-state. The SP8T switch of 3-stage tree topology was developed based on an arrangement of the proposed RF MEMS switches. The developed SP8T switch had an actuation voltage of 12 V, an insertion loss of 1.3 dB, a return loss of 15.1 dB, and an isolation of 31.4 dB at 6 GHz.

Performance Analysis for Closed-Loop Production Systems with Unreliable Machines and Random Processing Times (불완전한 기계 및 랜덤가공시간을 갖는 폐쇄형 생산시스템의 성능분석에 관한 연구)

  • Kim, H.G.;Paik, C.H.;Cho, H.S.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.2
    • /
    • pp.240-253
    • /
    • 1999
  • In this paper we propose new approximate methods for the performance analysis of closed-loop production systems with unreliable machines and random processing times. Each approximate method decomposes the production system consisting of K machines into a set of K subsystems, each subsystem consisting of two machines separated by a finite buffer. Then, each subsystem is analyzed by three different analyzing methods in isolation. The population constraint of the closed-loop production system is taken into account by prescribing that the sum of average buffer levels in the subsystems is equal to the number of customers in the closed-loop production system. We establish a set of equations that characterize unknown parameters of the servers in the subsystems. An iterative procedure is then used to determine the unknown parameters. Experimental results show that these methods provide a good estimation of the throughput.

  • PDF