• Title/Summary/Keyword: isolation systems

Search Result 783, Processing Time 0.032 seconds

Effect of seismic pounding on buildings isolated by triple friction pendulum bearing

  • Amiri, Gholamreza Ghodrati;Shakouri, Ayoub;Veismoradi, Sajad;Namiranian, Pejman
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.35-45
    • /
    • 2017
  • The current paper investigates the effect of the seismic pounding of neighboring buildings on the response of structures isolated by Triple Friction Pendulum Bearing (TFPB). To this end, a symmetric three-dimensional single story building is modeled for analysis with two specified levels of top deck and base deck, to capture the seismic response of the base isolators and building's roof. Linear elastic springs with different level of gaps are employed to calculate the impact between the buildings. Nonlinear Dynamic Time History Analyses (NDTHA) are conducted for seismic evaluation. Also, five different sizes with four different sets of friction coefficients are assumed for base isolators to cover a whole range of base isolation systems with various geometry configurations and fundamental period. The results are investigated in terms of base shear, buildings' drift and top deck acceleration of the superstructure. The results also indicate the profound effect of the stiffness of the adjacent buildings on the value of the impact they impose to the superstructure. Also, in situations of potential pounding, the increment of the fundamental period of the TFPB base isolator could intensify the impact force up to nearly five-fold.

The smart PFD with LRB for seismic protection of the horizontally curved bridge

  • Kataria, N.P.;Jangid, R.S.
    • Smart Structures and Systems
    • /
    • v.17 no.5
    • /
    • pp.691-708
    • /
    • 2016
  • Recently, number of smart material are investigated and widely used in civil construction and other industries. Present study investigates the application of smart semi-active piezoelectric friction damper (PFD) made with piezoelectric material for the seismic control of the horizontally curved bridge isolated with lead rubber bearing (LRB). The main aim of the study is to investigate the effectiveness of hybrid system and to find out the optimum parameters of PFD for seismic control of the curved bridge. The selected curved bridge is a continuous three-span concrete box girder supported on pier and rigid abutment. The PFD is located between the deck and abutments or piers in chord and radial directions. The bridge is excited with four different earthquake ground motions with all three components (i.e. two horizontal and a vertical) having different characteristics. It is observed that the use of semi-active PFD with LRB is quite effective in controlling the response of the curved bridge as compared with passive system. The incorporation of the smart damper requiring small amount of energy in addition with an isolation system can be used for effective control the curved bridge against the dynamic loading.

The Seismic Behavior of the Truss-Arch Structure with Lead Rubber Bearing(LRB) (납-고무면진장치가 적용된 트러스-아치 구조물의 지진거동 분서)

  • Shin, Min -Gi;Kim, Gee-Cheol;Kang, Joo-Won
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.133-138
    • /
    • 2008
  • In this study, the seismic behavior of arch structure with lead rubber bearing(LRB) is analyzed. The arch structure is the simplest structure and has the basic dynamic characteristics among large spatial structures. Also, Large spatial structures have large vertical response by horizontal seismic vibration, unlike seismic behavior of normal rahmen structures. When horizontal seismic load is applied to the large spatial structure with isolation systems, the horizontal acceleration response of the large spatial structure is reduced and the vertical seismic response is remarkably reduced.

  • PDF

Isolation and Identification of Legionella pneumophila from Hot Water Spouts and Hot Water (溫水수도꼭지와 온수에서 Legionella pneumophila의 分離同定)

  • Park, Ju-Hyeong;Zong, Moon-Shik
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.1
    • /
    • pp.23-32
    • /
    • 1988
  • A study was carried out to find distribution of Legionella spp. in hot water supplying systems of buildings in Seoul. Water samples were taken from the hot water taps in three research institute buildings during the period from the 2nd to 27th February, 1987. And all of the three buildings were supplied with hot water from the same central hot water tank. GVPC BCYEa and blood agar were used for the isolation of Legionella pneurnophila and slide agglutination test (SAT) was performed to identify their strain types. Main findings were as follows 1. 44 samples taken from hot tap-water revealed 20% of positive culture and 44 samples taken from hot water spouts revealed 11% of positive culture. 2. The 78% of positive samples taken from hot water was obtained from 25.1$\circ$C~45.0$\circ$C temperature range. 3. Only, Legionella pneumophila serogroup 3 was identified and most of them has been than 2$\mu$m in length. 4. The densities of the Legionella pneurnophila isolated from hot water samples were within the range of $1.0\times 10^2$ to $1.1\times 10^3$ CFU/l and their densities isolated from hot water spouts were either 1 CFU/plate or 2 CFU/plate.

  • PDF

Investigation of Floor Impact Sound Levels in Rahmen Structure Multi-story Residential Buildings (라멘복합구조 공동주택의 바닥충격음 실태)

  • 정정호;송희수;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.308-311
    • /
    • 2004
  • It is reported that there is a limit in increasing heavy-weight impact noise isolation performance of the load bearing wall system apartments to meet the regulation of the Ministry of Construction and Transportation (MOCT). To increase the heavy-weight impact noise isolation performance, improvement in structural systems such as increasing concrete slab thickness and application of rahmen structure were proposed. In this study floor impact sound levels from toil apartments with two rahmen structure multi-story residential buildings were measured before the construction of the buildings finished. Measurements were made at living room and two bedrooms at each apartment when the finishing processes were finished. The average value of light-weight impact sound level from ten apartments was 56dB (L'$\sub$n,Aw/). The heavy-weight impact sound level was 44dB (L'$\sub$i.Fmax.Aw/) and the impact sound level of the impact ball was 41dB(L'$\sub$i.Fmax.Aw/), As a result floor impact noises at the rahmen structure system were lower than the regulation level.

  • PDF

Ku-Band Sub-Harmonically Pumped Single Balanced Resistive Mixers with a Low Pass Filter Using Photonic Band Gap

  • Kim, Jae-Hyuk;Park, Hyun-Joo;Lee, Jong-Chul;Kim, Nam-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.4
    • /
    • pp.599-609
    • /
    • 2000
  • In this paper, sub-harmonically pumped single balanced resistive mixers are presented . Frequency bandwidth is selected for a Ku-band, which is 11.75-12.25GHz for RF, 5.375∼5.625 GHz for LO, and 1 GHz for IF signals. A rat-race hybrid is designed for the accomplishment of single balanced type. A low pass filter (LPF) with photonic band gap(PBG) structure is used for good conversion loss and unwanted harmonics suppression. Two types of mixers are suggested, which are one with no gate bias for no DC power consumption and the other with the IF amplifier for conversion gain. When a LO signal with the power of 6 dBm at 5.5 GHz is injected, a conversion loss of 12.17dB and a conversion gain of 7.83 dB are obtained for each mixer. For the both mixers , LO to RF isolation of 20 dB and LO to IF isolation of 60dB are obtained. With the RF power of -30dBm to -3dBm, the mixer shows linear characteristics region of IF. this mixer can be applied for Ku-band and other microwave communication systems.

  • PDF

Canonical correlation analysis based fault diagnosis method for structural monitoring sensor networks

  • Huang, Hai-Bin;Yi, Ting-Hua;Li, Hong-Nan
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.1031-1053
    • /
    • 2016
  • The health conditions of in-service civil infrastructures can be evaluated by employing structural health monitoring technology. A reliable health evaluation result depends heavily on the quality of the data collected from the structural monitoring sensor network. Hence, the problem of sensor fault diagnosis has gained considerable attention in recent years. In this paper, an innovative sensor fault diagnosis method that focuses on fault detection and isolation stages has been proposed. The dynamic or auto-regressive characteristic is firstly utilized to build a multivariable statistical model that measures the correlations of the currently collected structural responses and the future possible ones in combination with the canonical correlation analysis. Two different fault detection statistics are then defined based on the above multivariable statistical model for deciding whether a fault or failure occurred in the sensor network. After that, two corresponding fault isolation indices are deduced through the contribution analysis methodology to identify the faulty sensor. Case studies, using a benchmark structure developed for bridge health monitoring, are considered in the research and demonstrate the superiority of the new proposed sensor fault diagnosis method over the traditional principal component analysis-based and the dynamic principal component analysis-based methods.

Efficient Isolation of Intact RNA from the Soft Coral Scleronephthya gracillimum $(K\ddot{u}kenthal)$ for Gene Expression Analyses

  • Woo, Seo-Nock;Yum, Seung-Shic;Yoon, Moon-Geun;Kim, Sa-Heung;Lee, Jong-Rak;Kim, Jeong-Ha;Lee, Taek-Kyun
    • Animal cells and systems
    • /
    • v.9 no.4
    • /
    • pp.205-209
    • /
    • 2005
  • A rapid, simple and efficient method to extract RNA from the adult polyps of a soft coral, marine cnidarian, Scleronephthya gracillimum $(K\ddot{u}kenthal)$; was developed in this study. The highest yield and purity of RNA was obtained with the lysis solution containing 35 mM EDTA, 0.7 M LiCl, 7.0% SDS, and 200 mM Tris-Cl (pH 9.0). Approximately $40{\mu}g$ of total RNA was extracted from 200 mg of liquid nitrogen-pulverized polyp tissue. The ratio of absorbance at 260 nm and 280 nm ranged from 1.8 to 2.0. The results of the reverse transcription polymerase chain reaction (RTPCR) with ${\beta}-actin$ gene specific primers and Northern blot analysis using the same gene probe revealed that the RNA extracted by our method had high quality, and was sufficient for subsequent molecular biological analyses. This method was effective for RNA extraction from other soft coral species which belong to the genus Dendronephthya.

VSB-Based Digital On-Channel Repeater with Interference Cancellation System

  • Lee, Jae-Kwon;Suh, Young-Woo;Choi, Jin-Yong;Seo, Jong-Soo
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.670-678
    • /
    • 2011
  • This paper investigates the design and performance of a digital on-channel repeater (DOCR) for use in Advanced Television Systems Committee (ATSC) digital television (DTV) broadcasting. The main drawback of a DOCR is the echo interference caused by coupling between transmitter and receiver antennas, which induces system instability and performance degradation. In order to overcome this problem, an echo canceller based on the adaptive echo channel estimation (ECE) technique has been researched and applied for a DOCR. However, in the case of ATSC, the pilot signal, which is used for carrier synchronization, may cause a DC offset error and reduce the isolation performance of the echo canceller for a DOCR in an ATSC network. Moreover, since the multipath fading effect of a radio channel usually occurs in a real environment, it should be minimized to improve the overall performance of a DOCR. Therefore, due to the limited isolation performance of echo canceller and the multipath fading effect, an interference cancellation system (ICS) is proposed for a DOCR in an ATSC network. The performance of the proposed DOCR with an ICS is evaluated by software simulation and hardware test results.

Seismic response distribution estimation for isolated structures using stochastic response database

  • Eem, Seung-Hyun;Jung, Hyung-Jo
    • Earthquakes and Structures
    • /
    • v.9 no.5
    • /
    • pp.937-956
    • /
    • 2015
  • Seismic isolation systems decouple structures from ground motions to protect them from seismic events. Seismic isolation devices have been implemented in many full-scale buildings and bridges because of their simplicity, economic effectiveness, inherent stability, and reliability. It is well known that the most uncertain aspect for obtaining the accurate responses of an isolated structure from seismic events is the seismic loading itself. It is needed to know the seismic response distributions of the isolated structure resulting from the randomness of earthquakes when probabilistic designing or probabilistic evaluating an isolated structure. Earthquake time histories are useful and often an essential element for designing or evaluating isolated structures. However, it is very challenging to gather the design and evaluation information for an isolated structure from many seismic analyses. In order to evaluate the seismic performance of an isolated structure, numerous nonlinear dynamic analyses need to be performed, but this is impractical. In this paper, the concept of the stochastic response database (SRD) is defined to obtain the seismic response distributions of an isolated structure instantaneously, thereby significantly reducing the computational efforts. An equivalent model of the isolated structure is also developed to improve the applicability and practicality of the SRD. The effectiveness of the proposed methodology is numerically verified.