• Title/Summary/Keyword: isolation systems

Search Result 783, Processing Time 0.026 seconds

Performance Evaluation of Vibration Control of a Smart Top-Story Isolation System (스마트 최상층 면진시스템의 진동제어 성능평가)

  • Kang, Joo-Won;Kim, Tae-Ho;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.3
    • /
    • pp.49-56
    • /
    • 2010
  • In this study, the control performance of a smart top-story isolation system for tall buildings subjected to wind excitation was investigated. To this end, a 77-story tall building structure was employed and wind loads obtained from wind tunnel test were used for numerical simulations. The top-story of an example structure is separated from the main structure by a smart base isolation system composed of friction pendulum systems (FPS) and MR dampers. The primary purpose of the smart top-story isolation system is to mitigate the dynamic responses of the main structure, but the excessive movement of the isolated top story may cause the unstableness of the building structure. Therefore, the skyhook control algorithm was used to effectively reduce both responses of the isolated top story and the main structure. The control performance of the proposed smart top-story isolation system was investigated in comparison with that of the passive top-story isolation system. It has been shown from numerical simulation results that the smart top-story isolation system can effectively reduce wind-induced responses of the example building structure compared to the passive top-story isolation system with reduction of the top-story movement.

  • PDF

Investigation of Adaptability of Smart Base Isolation System for Spacial Structures in Regions of Low-to-Moderate Seismicity (중약진지역 대공간 구조물에 대한 스마트 면진시스템의 적용성 검토)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.4
    • /
    • pp.109-119
    • /
    • 2011
  • To date, a smart base isolation system has been developed in high seismicity region such as Japan, USA etc. Smart base isolation systems developed for structures in high seismicity region cannot directly applied to structures in regions of low-to-moderate seismicity such as Korea. Therefore, problems that occur by applying the smart base isolation system developed for the structures in high seismicity region to the structures in regions of low-to-moderate seismicity have been investigated in this study. To this end, a spacial arch structure was used as an example structure and MR dampers and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes were used for ground motions in regions of high and low-to-moderate seismicity. Based on numerical simulation results, it has been known that the capacity of smart base isolation system for the regions of low-to-moderate seismicity should be carefully designed because the base isolation effects of the smart base isolation system for high seismicity region is deteriorated when it is applied to the structures in regions of low-to-moderate seismicity.

Analysis of Data Isolation Methods for Secure Web Site Development in a Multi-Tenancy Environment (멀티테넌시 환경에서 안전한 웹 사이트 개발을 위한 데이터격리 방법 분석)

  • Jeom Goo Kim
    • Convergence Security Journal
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2024
  • Multi-tenancy architecture plays a crucial role in cloud-based services and applications, and data isolation within such environments has emerged as a significant security challenge. This paper investigates various data isolation methods including schema-based isolation, logical isolation, and physical isolation, and compares their respective advantages and disadvantages. It evaluates the practical application and effectiveness of these data isolation methods, proposing security considerations and selection criteria for data isolation in the development of multi-tenant websites. This paper offers important guidance for developers, architects, and system administrators aiming to enhance data security in multi-tenancy environments. It suggests a foundational framework for the design and implementation of efficient and secure multi-tenant websites. Additionally, it provides insights into how the choice of data isolation methods impacts system performance, scalability, maintenance ease, and overall security, exploring ways to improve the security and stability of multi-tenant systems.

A Study on a SPDT Switch with High Isolation Using Radial Resonators (방사형 공진기를 이용한 고격리도 SPDT 스위치 연구)

  • Yu Ri SO;Yunjian GUO;Jae Gook LEE;Min Jae LEE;Jong Chul Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.6
    • /
    • pp.223-229
    • /
    • 2023
  • This papart proposes single pole double throw (SPDT) switch with six-stage radial stub resonators in the 3.6~4.0 GHz band. The switch was simulated using ADS (Advanced Design Software), a design tool for the wireless communication circuits, and evaluated on a pcb substrate. The measurement results of the radial SPDT switch showed an average 90 dB isolation, and 1.5 dB insertion loss. This isolation characteristic was 20 dB superior to higher than those laboratory or commercial products reported thus far. The proposed SPDT switch is applicable to multi-band RF front-end systems, such as WiMAX, LTE/5G, Wi-Fi, and HyperLAN.

Performance Analysis of Full Duplex on-regenerative Relay

  • Ban, Tae-Won;Jung, Bang-Chul
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.6
    • /
    • pp.647-651
    • /
    • 2011
  • In this letter, non-regenerative Amplify-and-Forward (AF) relay systems based on half and full duplex schemes are investigated and their performance is analyzed and compared in terms of outage probability. Although the AF relay systems have been widely investigated in many previous literatures, most of them adopted a half duplex scheme due to hardware limitation and mathematical tractability. To the best of our knowledge, this letter is the first study to investigate the performance of the full duplex AF relay system considering practical hardware limitations. In full duplex AF relay systems, it is important to secure the isolation between transmit and receive antennas. Our numerical and simulation results show that there exists a threshold point of the isolation gain that the full duplex relay system outperforms the half duplex relay system.

A comparative study on aseismic performances of base isolation systems for multi-span continuous bridge (다경간 연속교에 대한 면진용 교좌장치의 내진성능 비교연구)

  • Park, Kyu-Sik;Lee, Chong-Heon;Lee, In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.383-390
    • /
    • 2001
  • Various base isolation systems, which are widely used, are compared for aseismic performances of multi-span continuous bridge. They are the P-F, RB, LRB, R-FBI and EDF systems. Sensitivity analyses are carried out to determine the design parameters of various devices. The design parameters, natural period of the isolated bridge and friction coefficient of the bearing, are determined by the reciprocal relationship between displacement and bending moment of the structure. Then the relative effectiveness of the bearings is described. Bridge with the R-FBI system shows the smallest peak displacement of deck whereas bridge with the EDF system shows the smallest peak bending moment of the lower end of pier in numerical examples. Furthermore, the peak responses of bridge with the friction type bearing are less sensitive to substantial variations in the frequency range and intensity of the ground excitation than those with the rubber type bearing.

  • PDF

Comparison of Mating Systems in Populations of Gleditsia japonica var. koraiensis

  • Huh, Man-Kyu
    • Journal of Ecology and Environment
    • /
    • v.29 no.5
    • /
    • pp.411-414
    • /
    • 2006
  • The mating systems of two groups of natural populations of Gleditsia japonica var. koraiensis in Korea were determined using allozyme analysis. The result suggests that G. japonica var. koraiensis is predominantly outcrossing. The tm values of eight populations in Korea varied from 0.667 (Mdh-1) to 0.938 (ldh-1), giving an average 0.820. Population and individual outcrossing estimates were associated with flowering tree density or degree of spatial isolation. The reason for relatively low outcrossing rates of some populations could be attributed to reduction of effective population sizes of sib for the medicine, small population size, and isolation of flowering mature trees. The heterozygote excesses were observed in some natural populations, whereas other populations exhibited varying degrees of inbreeding and heterozygotes deficit. Thus, selection against homozygotes operated in the progeny populations throughout the life cycle.

A 3 kW Bidirectional DC-DC Converter for Electric Vehicles

  • Ansari, Arsalan;Cheng, Puyang;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.860-868
    • /
    • 2016
  • A bidirectional DC-DC converter (BDC) is an indispensable electrical unit for the electric vehicles (EVs). High efficiency, high power density, isolation, light weight and reliability are all essential requirements for BDC. In this paper, a 3 kW BDC for the battery charger of EVs is proposed. The proposed converter consists of a half-bridge structure on the primary side and an isolation transformer and a synchronous rectifier structure on the secondary side. With this topology, minimum number of switching devices are required for bidirectional power flow between the two dc buses of EVs. The easy implementation of the synchronous rectification gives advantages in terms of efficiency, cost and flexibility. The proposed BDC achieves high efficiency when operating in both modes (step-up and step-down). A 3 kW prototype is implemented to verify theoretical analysis and the performance of the proposed converter.

Co-located and space-shared multiple-input multiple-output antenna module and its applications in 12 × 12 multiple-input multiple-output systems

  • Longyue Qu;Haiyan Piao;Guohui Dong
    • ETRI Journal
    • /
    • v.45 no.2
    • /
    • pp.203-212
    • /
    • 2023
  • In this study, we developed a co-located and space-shared multiple-input multiple-output (MIMO) antenna module with a modular design and high integration level. The proposed antenna pair includes a half-wavelength loop antenna and a dipole-type antenna printed on the front and back sides of a compact modular board. Owing to their modal orthogonality, these two independent antenna elements are highly self-isolated and free of additional decoupling components, even though they are assembled at the same location and within the same space. Thus, the proposed antenna is attractive in 5G MIMO systems. Furthermore, the proposed co-located and space-shared MIMO antenna module was employed in a 5G smartphone to verify their radiation and diversity performances. A 12 × 12 MIMO antenna system was simulated and fabricated using the proposed module. Based on the results, the proposed module can be employed in large-scale MIMO antenna systems for current and future terminal devices owing to its high integration, compactness, simple implementation, and inherent isolation.

The effect of composite-elastomer isolation system on the seismic response of liquid-storage tanks: Part I

  • Shahrjerdi, A.;Bayat, M.
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.513-528
    • /
    • 2018
  • A typical viable technique to decrease the seismic response of liquid storage tanks is to isolate them at the base. Base-isolation systems are an efficient and feasible solution to reduce the vulnerability of structures in high seismic risk zones. Nevertheless, when liquid storage tanks are under long-period shaking, the base-isolation systems could have different impacts. These kinds of earthquakes can damage the tanks readily. Hence, the seismic behaviour and vibration of cylindrical liquid storage tanks, subjected to earthquakes, is of paramount importance, and it is investigated in this paper. The Finite Element Method is used to evaluate seismic response in addition to the reduction of excessive liquid sloshing in the tank when subjected to the long-period ground motion. The non-linear stress-strain behaviour pertaining to polymers and rubbers is implemented while non-linear contact elements are employed to describe the 3-D surface-to-surface contact. Therefore, Nonlinear Procedures are used to investigate the fluid-structure interactions (FSI) between liquid and the tank wall while there is incompressible liquid. Part I, examines the effect of the flexibility of the isolation system and the tank aspect ratio (height to radius) on the tank wall radial displacements of the tank wall and the liquid sloshing heights. Maximum stress and base shear force for various aspect ratios and different base-isolators, which are subjected to three seismic conditions, will be discussed in Part II. It is shown that the composite-base isolator is much more effective than other isolators due to its high flexibility and strength combined. Moreover, the base isolators may decrease the maximum level pertaining to radial displacement.