• 제목/요약/키워드: isolated ceiling

검색결과 7건 처리시간 0.022초

분리된 천정의 설치를 통한 목구조 바닥의 내화성능 및 충격음 차단성능 향상 (Improvement of Fire Resistance and Impact Sound Insulation Performance for Timber Framed Floor by Installation of Isolated Ceiling)

  • 박주생;김세종;이상준
    • 한국가구학회지
    • /
    • 제24권4호
    • /
    • pp.426-432
    • /
    • 2013
  • Fire resistance and impact sound insulation tests were performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by installing glulam beam additionally in the middle or one thirds of the original span, and which an additional ceiling component was installed apart from floor structure. By applying the isolated ceiling, timber framed floor showed 1 hour of fire resistance even in case that dead load was increased by considering cement mortar layer for radiant floor heating. Insulation performance against light and heavy impact sound was improved significantly by applying the sound absorbing layer of big mass and high elasticity in addition to the stiffness improvement and isolated ceiling.

  • PDF

폐기물 저감 인센티브를 고려한 고립지역의 효율적 폐기물 관리 스케줄 (Optimal Scheduling for Efficient Waste Management in Isolated Regions from the Perspective of Waste Reduction Incentives)

  • 황석준;황욱;김현철
    • 자원ㆍ환경경제연구
    • /
    • 제26권3호
    • /
    • pp.399-416
    • /
    • 2017
  • 본 연구는 Keller(1974)의 최적 점검 모형을 이용하여 도서지역과 같은 고립지역에서의 폐기물 누적 발생량 추이를 추적하면서 발생량이 기준치를 초과하는 경우 이를 수거하는 효율적인 관리 스케줄 선택에 관한 문제를 살펴본다. 고립지역에서는 폐기물 발생량이 기준치를 초과하는지 여부를 파악하기 위하여 관리당국의 점검이 일정 기간 동안 적극적으로 자주 시행될 수도 있지만 이에 따른 모니터링 비용이 증가한다는 점과 아울러 기준치를 초과하여 누적되는 폐기물이 바로 수거되지 않는 상태가 지속되면 폐기물 관리기술의 혁신에 대한 사회적 요구도 높아질 수 있다는 점을 동시에 고려하여 최적 점검 스케줄에 대한 함의를 파악한다. 본 연구는 모니터링 비용이 증가하거나 폐기물 관리 시스템의 실패율이 작아지면 관리 당국의 점검은 느슨하게 시행되겠지만 폐기물 누적 발생량이 기준치 이상으로 증대함으로써 고립지역 사회가 겪게 되는 후생 손실이 커지면 점검은 자주 시행될 것을 제시한다. 또한 폐기물 누적 발생량이 기준을 초과함으로써 촉진되는 혁신노력에 따른 사회적 한계편익이 상대적으로 작은 경우에도 적극적인 점검이 최적의 선택임을 제시한다.

쉴드 TBM터널 상부 지반 연약대 전기탐사 (Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling)

  • 정현기;박철환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

사무실 근로자의 홈오피스 디자인 특성에 관한 선호 조사 연구 (A Study on Preferences for Home Office Design Criteria)

  • 하미경;제해성;구본삼
    • 한국실내디자인학회논문집
    • /
    • 제14호
    • /
    • pp.55-62
    • /
    • 1998
  • One of the major changes in the information era is that the concept of workplace is changing, Therefore this research is to provide basic data for future home office design by surveying office workers's opinions about preferred design for home office. This research is based on a survey of 215 office workers in Seoul. The major findings are ; Office workers prefer an isolated type of workplace that is arranged by U-shped workstation at home. Office workers preferred ivory color of walls and ceiling in home office, Brown color for the floor and brown ivory beige green and grey colors are preferred for the furniture. For home office furniture office workers put to an importance on desk chair computer table cabinet filbox sofa mobil lack credenza, and tea table.

  • PDF

지진격리된 복층구조 파이핑 시스템의 내진성능평가 (Seismic Performance Evaluation of Base-Isolated Multi-Story Piping System)

  • 전준태;류용희;주부석
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2016년 정기학술대회
    • /
    • pp.311-313
    • /
    • 2016
  • 본 연구는 지진격리장치가 적용된 파이핑 시스템에서 빌딩과 같은 구조요소의 상호작용에 의한 동적 거동을 분석하고자 기존 복층구조 파이핑 시스템과 빌딩시스템에 triple friction pendulum이 적용된 격리장치를 적용 하였다. 파이핑 시스템의 시간이력해석에 의한 동적거동 평가를 위해 OpenSees를 이용하여 지진격리된 빌딩 및 파이핑시스템의 수치해석모델을 구축하였으며, 또한 파이핑시스템의 경우 ceiling system and supporting system 등과 같은 요소로 구분하여 유한요소모델을 구축하였다. 결과적으로 지진격리장치가 적용된 빌딩-파이핑 시스템의 경우 각층의 drift 및 변위가 일정한 반면 비 적용된 시스템의 경우 층 가속도에 의한 구조물의 변위가 빌딩층에 따라 상당히 증가함을 볼 수 있다.

  • PDF

융합 센서 네트워크 정보로 보정된 관성항법센서를 이용한 추측항법의 위치추정 향상에 관한 연구 (Study on the Localization Improvement of the Dead Reckoning using the INS Calibrated by the Fusion Sensor Network Information)

  • 최재영;김성관
    • 제어로봇시스템학회논문지
    • /
    • 제18권8호
    • /
    • pp.744-749
    • /
    • 2012
  • In this paper, we suggest that how to improve an accuracy of mobile robot's localization by using the sensor network information which fuses the machine vision camera, encoder and IMU sensor. The heading value of IMU sensor is measured using terrestrial magnetism sensor which is based on magnetic field. However, this sensor is constantly affected by its surrounding environment. So, we isolated template of ceiling using vision camera to increase the sensor's accuracy when we use IMU sensor; we measured the angles by pattern matching algorithm; and to calibrate IMU sensor, we compared the obtained values with IMU sensor values and the offset value. The values that were used to obtain information on the robot's position which were of Encoder, IMU sensor, angle sensor of vision camera are transferred to the Host PC by wireless network. Then, the Host PC estimates the location of robot using all these values. As a result, we were able to get more accurate information on estimated positions than when using IMU sensor calibration solely.

고령 고아리 벽화고분의 보존환경 연구 (Conservation Environment for Mural Tomb in Goa-ri, Goryeong)

  • 정선혜;이현주;이민영;정용재
    • 보존과학회지
    • /
    • 제33권3호
    • /
    • pp.189-201
    • /
    • 2017
  • 본 연구는 가야시대 고분인 고령 고아리 벽화고분을 대상으로 하였다. 고분의 보존환경 연구를 위해 고분의 환경(온습도, 표면온도, 결로)과 생물(미생물 분포) 모니터링을 1년간 실시하였다. 그 결과, 고분 내외부의 연평균 온도차는 $11.7^{\circ}C$로 확인되었고 고분 내부의 온도는 외부 온도와 1~2개월 격차로 변화되고 있었다. 고분 내 최고 온도는 9월, 최저 온도는 3월이었고 상대습도는 약 100%로 유지되었다. 결로의 경우 벽화가 그려진 고분 현실의 천장에는 4월부터 12월까지 결로가 발생하였고, 연도 천장에는 1년 내내 결로가 발생하였다. 고분 내부와 벽체 표면에서는 미생물이 분리 배양되어 미생물 생장에 적합한 환경이 조성되면 생장가능 할 것으로 판단된다. 따라서 미생물 생장 온도 조건을 기준으로 미생물 발생 위험 예측도를 작성하였고 8월부터 10월이 위험 기간으로 확인되었다.