• Title/Summary/Keyword: isolated ceiling

Search Result 7, Processing Time 0.027 seconds

Improvement of Fire Resistance and Impact Sound Insulation Performance for Timber Framed Floor by Installation of Isolated Ceiling (분리된 천정의 설치를 통한 목구조 바닥의 내화성능 및 충격음 차단성능 향상)

  • Park, Joo-Saeng;Kim, Se-Jong;Lee, Sang-Joon
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.4
    • /
    • pp.426-432
    • /
    • 2013
  • Fire resistance and impact sound insulation tests were performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by installing glulam beam additionally in the middle or one thirds of the original span, and which an additional ceiling component was installed apart from floor structure. By applying the isolated ceiling, timber framed floor showed 1 hour of fire resistance even in case that dead load was increased by considering cement mortar layer for radiant floor heating. Insulation performance against light and heavy impact sound was improved significantly by applying the sound absorbing layer of big mass and high elasticity in addition to the stiffness improvement and isolated ceiling.

  • PDF

Optimal Scheduling for Efficient Waste Management in Isolated Regions from the Perspective of Waste Reduction Incentives (폐기물 저감 인센티브를 고려한 고립지역의 효율적 폐기물 관리 스케줄)

  • Hwang, Seok-Joon;Hwang, Uk;Kim, Hyun-Cheol
    • Environmental and Resource Economics Review
    • /
    • v.26 no.3
    • /
    • pp.399-416
    • /
    • 2017
  • This study examines the problem of efficient scheduling of waste collection in isolated regions like islands when the waste accumulated amount surpasses the standard ceiling by effectively tracking the accumulating trends based on the optimum checking model of Keller (1974). To grasp whether the waste accumulated amount in isolated regions exceeds the standard ceiling, the relevant authorities can tightly check during a set period, but this entails higher monitoring costs. On the other hand, if the accumulated waste over the ceiling is not immediately checked and collected, and continues for a set period of time, innovative efforts for waste management may be highly demanded. As such, the tradeoffs are considered to draw the optimal checking schedule. This study shows that the authorities get to check less frequently the waste accumulation trends if the monitoring costs increase or when the failure rate of waste management systems drops. On the other hand, they get to check more frequently if the accumulated waste amount in isolated regions exceeds the standard ceiling and welfare loss grows as a result. It also shows that frequent checking is the optimal choice if the social marginal benefits enjoyed from innovative efforts made to keep accumulated waste below the standard ceiling, are not significant.

Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling (쉴드 TBM터널 상부 지반 연약대 전기탐사)

  • Jung, Hyun-Key;Park, Chul-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

A Study on Preferences for Home Office Design Criteria (사무실 근로자의 홈오피스 디자인 특성에 관한 선호 조사 연구)

  • 하미경;제해성;구본삼
    • Korean Institute of Interior Design Journal
    • /
    • no.14
    • /
    • pp.55-62
    • /
    • 1998
  • One of the major changes in the information era is that the concept of workplace is changing, Therefore this research is to provide basic data for future home office design by surveying office workers's opinions about preferred design for home office. This research is based on a survey of 215 office workers in Seoul. The major findings are ; Office workers prefer an isolated type of workplace that is arranged by U-shped workstation at home. Office workers preferred ivory color of walls and ceiling in home office, Brown color for the floor and brown ivory beige green and grey colors are preferred for the furniture. For home office furniture office workers put to an importance on desk chair computer table cabinet filbox sofa mobil lack credenza, and tea table.

  • PDF

Seismic Performance Evaluation of Base-Isolated Multi-Story Piping System (지진격리된 복층구조 파이핑 시스템의 내진성능평가)

  • Jeon, Jun-Tai;Ryu, Yong-Hee;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.311-313
    • /
    • 2016
  • 본 연구는 지진격리장치가 적용된 파이핑 시스템에서 빌딩과 같은 구조요소의 상호작용에 의한 동적 거동을 분석하고자 기존 복층구조 파이핑 시스템과 빌딩시스템에 triple friction pendulum이 적용된 격리장치를 적용 하였다. 파이핑 시스템의 시간이력해석에 의한 동적거동 평가를 위해 OpenSees를 이용하여 지진격리된 빌딩 및 파이핑시스템의 수치해석모델을 구축하였으며, 또한 파이핑시스템의 경우 ceiling system and supporting system 등과 같은 요소로 구분하여 유한요소모델을 구축하였다. 결과적으로 지진격리장치가 적용된 빌딩-파이핑 시스템의 경우 각층의 drift 및 변위가 일정한 반면 비 적용된 시스템의 경우 층 가속도에 의한 구조물의 변위가 빌딩층에 따라 상당히 증가함을 볼 수 있다.

  • PDF

Study on the Localization Improvement of the Dead Reckoning using the INS Calibrated by the Fusion Sensor Network Information (융합 센서 네트워크 정보로 보정된 관성항법센서를 이용한 추측항법의 위치추정 향상에 관한 연구)

  • Choi, Jae-Young;Kim, Sung-Gaun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.8
    • /
    • pp.744-749
    • /
    • 2012
  • In this paper, we suggest that how to improve an accuracy of mobile robot's localization by using the sensor network information which fuses the machine vision camera, encoder and IMU sensor. The heading value of IMU sensor is measured using terrestrial magnetism sensor which is based on magnetic field. However, this sensor is constantly affected by its surrounding environment. So, we isolated template of ceiling using vision camera to increase the sensor's accuracy when we use IMU sensor; we measured the angles by pattern matching algorithm; and to calibrate IMU sensor, we compared the obtained values with IMU sensor values and the offset value. The values that were used to obtain information on the robot's position which were of Encoder, IMU sensor, angle sensor of vision camera are transferred to the Host PC by wireless network. Then, the Host PC estimates the location of robot using all these values. As a result, we were able to get more accurate information on estimated positions than when using IMU sensor calibration solely.

Conservation Environment for Mural Tomb in Goa-ri, Goryeong (고령 고아리 벽화고분의 보존환경 연구)

  • Jeong, Seon Hye;Lee, Hyun Ju;Lee, Min Young;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.33 no.3
    • /
    • pp.189-201
    • /
    • 2017
  • This study focused on the Gaya mural tomb located in Goa-ri, Goryeong-gun, North Gyeongsang Province, Republic of Korea. Environmental factors such as ambient temperature, relative humidity and surface temperature, and microbial distribution on mural tombs were monitored for one year to gather data on the conservation environment of the mural tombs. The average internal temperature difference with reference to the ambient outer temperature was observed to be $11.7^{\circ}C$ for the monitoring period and the internal temperature of the tomb was found to change periodically every one or two months in response to the outer temperature. The highest temperature was observed in September and the lowest in March. The relative humidity in the mural tomb remained constant at 100%. Between December and April, condensation occurred on the ceiling of the main room of the tomb, where the murals are located. On the ceiling of the aisle, the condensation occurred throughout the year. The inside and surface wall were isolated from microorganisms, which could grow when a suitable growth environment suitable is established. Based on microbial growth temperature conditions, risk periods of microbial hazards were established, where in the period from August to October was identified as the most dangerous.