• Title/Summary/Keyword: irradiation facility

Search Result 98, Processing Time 0.022 seconds

Study on Determination of Boron using the PGAA Facility at HANARO Research Reactor (하나로의 즉발감마선 방사화분석 장치를 이용한 붕소의 정량에 대한 연구)

  • Chung, Young-Sam;Cho, Hyun-Jae;Moon, Jong-Hwa;Kim, Sun-Ha;Kim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.391-398
    • /
    • 2003
  • Basic research for the determination of boron content in biological sample has been carried out using the PGAA facility of the 24MW research reactor(HANARO). For investigation of characteristics for the measurement condition, neutron flux and its homogeneity were measured at irradiating geometry. The size of thermal neutron beam collimated from beam guide is $2{\times}2cm^2$ at the sample position. The neutron flux measured was the range of $1.0{\sim}6.5{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, and flux distribution from center within the radius of 4.5 mm and 9.0 mm was $5.77{\pm}0.71{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$ and $4.68{\pm}1.64{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, respectively. Accordingly, sample size is adjusted within 10 mm for a homogeneous irradiation of high quality. Measurement system is designed to reduce the background source by Compton scattering and to improve the analytical sensitivity. To investigate the energy calibration and Compton suppression effect of gamma-ray counting system, the background conditions on both of Compton and single-mode were measured using NaCl standard. On the other hand, degree of spectral interference for sodium 472 keV peak as a matrix effect in the sample is established for an accurate boron analysis, and then boron content in three certified reference materials (NIST SRM 1570a, 1547, 1573a) was measured by using two modes and the results were compared with each other.

The Determination of Iodine in Human Milk and Cow Milk by Iodide Specific Ion electrode and Neutron Activation Analysis (요오드 전극을 이용한 방법과 중성자방사화 분석에 의한 모유 및 우유내 요오드 함량 분석 방법 비교)

  • 문수재
    • Journal of Nutrition and Health
    • /
    • v.31 no.2
    • /
    • pp.213-219
    • /
    • 1998
  • This study was conducted to compare and evaluate the iodide specific ion electrode method (ISE) and neutron activation analysis method (NAA) for determining iodine in human milk and cow milk. The neutron irradiation and counting operations were carried out at the TRIGA Mark-III reactor facility of the Korea Atomic Energy Research Institute. The mean concentrations of iodine in human milk samples by the ISE and the NAA were 1450$\mu\textrm{g}$/L and 1350$\mu\textrm{g}$/L, respectively. The levels were not significantly different. In cow milk samples , the mean concentrations of iodine by the ISE and the NAA were 250$\mu\textrm{g}$.L and 200$\mu\textrm{g}$/L, respectively. here, the ISE reading was significantly higher than the NAA. reading. The correlations of the two methods were 0.92(p<0.001) for human milk samples and 0.65 for cow milk samples . The coefficient of variation was 8.3% in the ISE and 4.9% in the NAA. Therefore, the iodide specific ion electrode method is sample and fast method, but probably not in processed milk since free sulfhydryl groups in milk are also detected by the iodide electrode. However, these also indicate that the ISE method may be applicable to human milk and pasteurized milk if the conventional pasteurization time-temperature relationship of standards is not exceeded. On the other hand, the NAA method , which is independent of chemical forms and matrix, can be used for determining iodine in all kinds of milk and foods.

  • PDF

Comparison of the $SO_2$ Removal Efficiency by Mixing Enhancement Shape (혼합 촉진 장치의 형상에 따른 탈황효율 비교)

  • Chung, Jin-Do;Kim, Jang-Woo;Bae, Young-Peel
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.17-22
    • /
    • 2010
  • The aim of this study is to research applicable possibility of DSI (Dry Sorbent Injection) technique in $SO_2$ removal process using lab-scale facility based on 500MW in capacity coal-fired thermal power plant operated by South Korea N. Power Co., Ltd. To increase the $SO_2$ removal efficiency, it is considered the mixing enhancement as different shapes called lobed-plate and stepplate tested ultimately for optimum shape. Also it tested to analysis $SO_2$ removal efficiency by numbers of injection holes. At experimental it showed the $SO_2$ removal efficiency is higher using mixing enhancement than not installed mixing enhancement and case on the step-plate was shown the most $SO_2$ removal efficiency. Also, $SO_2$ removal efficiency was higher recording which will increase the injection holes case on not installed mixing enhancement. But, the $SO_2$ removal efficiency was higher 4 injection holes case on installed mixing enhancement.

The Effect of Different Particle Size from PAHs Contaminated Sediment by Ultrasonic Irradiation (PAHs로 오염된 침전물의 초음파 처리시 입자크기가 미치는 영향)

  • Na, Seung-Min;Khim, Jee-Hyeong;Cui, Ming-Can;Ahn, Yun-Gyong;Weavers, Linda K.
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.379-387
    • /
    • 2010
  • Sediments of Little Scioto (LS) River in Ohio was contaminated by poor disposal of creosote from Baker Wood Creosoting Facility. Among the primary compounds of creosote, Polycyclic Aromatic Hydrocarbons (PAHs) are the most common ingredient PAHs are known for toxic, carcinogenic and mutagenic compounds. There are many difficulties to remove the PAHs in nature environment because their characteristics are having a less water-solubility, volatile and low mobility properties as increasing the molecular weight. The generation of hydroxyl radicals (${\cdot}OH$) and hydrogen peroxide ($H_2O_2$) forms as well as high temperature (5000 K) and pressure (1000 atm) by a physico-chemical effects of ultrasound during a cavitation collapse can promote the degradation and desorption of PAHs in sediment And it can also produces shock wave and microjets which are able to change the size and surface of particle in solid-liquid system as one of physical effects. Therefore, we explored to understand the role of particle size, the effect of elimination for PAHs concentration by ultrasound and optimize the conditions for ultrasonic treatment. The condition of various size of particles (> $150{\mu}m$, < $150{\mu}m$) and solid-liquid ratio (12.5g/L, 25g/L) for the treatment was considered and ultrasonic power (430 W/L) with liquid - hexane extraction and microwave extraction method were applied after ultrasound treatment.

Application of Commercial PIN Photodiodes to develope Gamma-Ray Dosimeters (감마선 선량계를 개발하기 위한 상용 PIN 포토 다이오드의 응용)

  • Jeong, Dong-Hwa;Kim, Sung-Duck
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.274-280
    • /
    • 2000
  • This paper deals with an experimental study to apply commercial semiconductors to measure radiation dose rate for gamma ray. Since the low cost, small size, high efficiency and ruggedness of silicon photodiodes make them attractive photodetectors, they coulde be effectively used in measuring any radiation such as gamma ray. Most PN photodiodes show that the reverse current increases when the light is increased. Therefore the depletion region of them have influence on the reverse current, so we choose silicon PIN photodiodes with large depletion region. In order to detect radiation dose rate and then, to apply in developing any gamma ray dosimeter, some examinations and experiments were performed to PIN photodiodes in this work. Two kinds of PIN photodiodes, such as NEC's PH302 and SIEMENS's BPW34, were tested in a Co-60 gamma irradiation facility with a semiconductor parameter analyzer. As a result, we found that such PIN photodiodes present good linearity in diode current characteristics with dose rate. Therefore silicon PIN photodiodes could be suitably used in designing gamma ray dosimeters.

  • PDF

Development of Radiation Dosimeter using Commercial p-MOSFET (상용 p-MOSFET을 이용한 방사선 선량계 개발)

  • Lee, Nam-Ho;Choi, Young-Su;Lee, Yong-B.;Youk, Geun-Uck
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • When a metal oxide field effect transistor (MOSFET) is exposed to ionizing radiation, electron/hole pairs are generated in its oxide layer. The slow moving holes of them are trapped in the oxide layer of p-MOSFET and appear as extra charges that change the characteristics of the transistor. The radiation-induced charges directly impact the threshold (turn-on) voltage of the transistor. This paper describes the use of the radiation-induced threshold voltage change as an accumulated radiation dose monitoring sensor. Two kinds of commercial p-type MOSFETS were tested in a Co-60 gamma irradiation facility to see their capabilities as a radiation dosimeter. We found that the transistors showed good linearity in their threshold voltage shift characteristics with radiation dose. The results demonstrate the potential use of commercial p-MOSFETS as inexpensive radiation sensors for the first time.

  • PDF

CHANGES IN BODY AND ORGAN WEIGHTS, HEMATOLOGICAL PARAMETERS, AND FREQUENCY OF MICRONUCLEI IN THE PERIPHERAL BLOOD ERYTHROCYTES OF ICR MICE EXPOSED TO LOW-DOSE-RATE $\gamma$-RADIATION

  • Kang, Yu-Mi;Shin, Suk-Chul;Jin, Young-Woo;Kim, Hee-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.102-106
    • /
    • 2009
  • We exposed ICR mice to low-dose (0.2 Gy) and low-dose-rate (0.7 mGy/h) $\gamma$-radiation ($^{137}Cs$) in the Low-dose-rate Irradiation Facility at the Radiation Health Research Institute to evaluate systemic effects of low-dose radiation. We compared the body and organ weights, number of blood cells (white and red blood cells and platelets), levels of biochemical markers in serum, and frequency of micronuclei in polychromatic erythrocytes between low-dose irradiated and non-irradiated control mice. The ICR mice irradiated with total doses of 0.2 and 2 Gy showed no changes in body and organ weights, number of blood cells (white and red blood cells), or frequency of micronuclei in the polychromatic erythrocytes of peripheral blood. However, the number of platelets (P = 0.002) and the liver weight (P < 0.01) were significantly increased in mice exposed to 0.2 and 2 Gy, respectively. These results suggest that a low-dose-rate of 0.7 mGy/h does not induce systemic damage. This dose promotes hematopoiesis in the bone marrow microenvironment and the proliferation of liver cells. In the future, the molecular biological effects of lower doses and dose rates need to be evaluated.

Real Time Image Acquisition System using a Image Intensifier and Position Error Verification (영상증배관을 이용한 실시간 영상획득시스템과 위치오차검증)

  • Lee, Dong-Hoon;Kim, Nam-Hoon;Jeong, Jong-Beom
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.331-338
    • /
    • 2017
  • In this study, a portable x-ray generator was manufactured and a real-time image acquisition system was constructed using the image intensifier from the generated generator. We have developed a real - time position error verification system that can verify whether the artificial joint position is different from the initial image from the acquired image. The template image of the region of interest is extracted from the reference image using the pattern matching technique and compared with the image to be compared. As a result, It is shown that real - time position error verification is achieved by displaying the difference angle. This system is portable type, has a self-shielding facility, and the output of the irradiation device can be manufactured in a small size of 1kw and can be used as a portable type. In case of emergency patients in the non-destructive field for industrial use, It has proved effective for use in small areas such as feet.

Activation Reduction Method for a Concrete Wall in a Cyclotron Vault

  • Kumagai, Masaaki;Sodeyama, Kohsuke;Sakamoto, Yukio;Toyoda, Akihiro;Matsumura, Hiroshi;Ebara, Takayoshi;Yamashita, Taichi;Masumoto, Kazuyoshi
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.3
    • /
    • pp.141-145
    • /
    • 2017
  • Background: The concrete walls inside the vaults of cyclotron facilities are activated by neutrons emitted by the targets during radioisotope production. Reducing the amount of radioactive waste created in such facilities is very important in case they are decommissioned. Thus, we proposed a strategy of reducing the neutron activation of the concrete walls in cyclotrons during operation. Materials and Methods: A polyethylene plate and B-doped Al sheet (30 wt% of B and 2.5 mm in thickness) were placed in front of the wall in the cyclotron room of a radioisotope production facility for pharmaceutical use. The target was Xe gas, and a Cu block was utilized for proton dumping. The irradiation time, proton energy, and beam current were 8 hours, 30 MeV, and $125{\mu}A$, respectively. To determine a suitable thickness for the polyethylene plate set in front of the B-doped Al sheet, the neutron-reducing effects achieved by inserting such sheets at several depths within polyethylene plate stacks were evaluated. The neutron fluence was monitored using an activation detector and 20-g on de Au foil samples with and without 0.5-mm-thick Cd foil. Each Au foil sample was pasted onto the center of a polyethylene plate and B-doped Al sheet, and the absolute activity of one Au foil sample was measured as a standard using a Ge detector. The resulting relative activities were obtained by calculating the ratio of the photostimulated luminescence of each foil sample to that of the standard Au foil. Results and Discussion: When the combination of a 4-cm-thick polyethylene plate and B-doped Al sheet was employed, the thermal neutron rate was reduced by 78%. Conclusion: The combination of a 4-cm-thick polyethylene plate and B-doped Al sheet effectively reduced the neutron activation of the investigated concrete wall.

Development of 10 kW Dish-Stirling System for Commercialization and Analysis of Operating Characteristics (10 kW급 접시형 태양열발전시스템 사업모델 개발 및 운전특성 분석)

  • Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.118-124
    • /
    • 2010
  • In order to develop commercial model of 10kW dish-Stirling solar thermal power system, modification for the exiting facility was taken for a year as a Leading Project in KIER. During the project, solar tracking system, control and monitoring system and high durability reflector were developed and long term operation were performed. The solar tracking system was tested for four months to investigate the degree of precision and adapted to the control system for an actual operation from October in 2009. The sun tracking accuracy of ${\pm}4$ mrad using modified control system was obtained and the system operated successfully during the experimental period. The monitoring system displays engine pressure, electric generation amounts, generator RPM, receiver temperatures, and etc. from Stirling engine and weather data of Direct Normal Irradiation, Horizontal Global Insolation, wind speed & direction, and atmosphere temperature from weather station. According to the operating results in a clear sky day, electric power of 6,890 W was generated at the DNI value of 850 W/$m^2$ and the averaged solar-to-electricity efficiency during a whole day reached to 18.99%. From the overall operating results, linear power generation trend could be observed with increasing DNI value. The solar-to-electricity efficiency achieved to 19% around the DNI value of 700 W/$m^2$ and increased to 20% when the DNI value goes up to 900 W/$m^2$.