• Title/Summary/Keyword: iron-core

Search Result 434, Processing Time 0.024 seconds

A Current Compensating Algorithm with Small Iron-cored CTs (작은 변류기 사용이 가능한 전류 보상 알고리즘)

  • Kang, Sang-Hee;Kang, Yong-Cheol;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.476-478
    • /
    • 1995
  • The conventional technique to deal with CT saturation is overdimensioning of the core so that CTs can carry up to 20 times the rated current without exceeding 10% ratio correction. However, this not only reduces the sensitivity of relays, but also increases the CT core size in proportion to the expected maximum fault current to avoid CT saturation. This paper presents a technique of estimating the secondary current corresponding to the CT ratio which can reduce the required CT core cross section significantly.

  • PDF

Phase transformer method and its application (위상변성방식과 그 응용)

  • 오상세
    • 전기의세계
    • /
    • v.13 no.2
    • /
    • pp.1-4
    • /
    • 1964
  • Phase transformation is used to change some phase from phase in A.C. system. We have been used Scott or Fork connection in phase transformation the otherwise phase transformation was constructed from M-G set. From this M-G set, we could make phase shift facilities by mannual. Now, I can derive more easy phase transformation from taking another method. I believe this new phase transformation method in the first thing in the world. And so, I am going to explain about phase transformer construction process. The first, we could devide into equal part of core around the iron core as to be same size. The second, you will make primary and secondary winding on the core. The third, when you will supplied three phase A.C. at the terminal of primary winding you can get e.m.f. inducing of some phase at secondary. And so, we could make phase change from some phase A.C. We can apply this principle in many fields, i.e., freequency changer, phase leader of no use condenser, voltage regulator in keeping balance, and D.C. generator. And more, I will introduce in details concerning main pinciple and theory through following chapter.

  • PDF

Effect of Metal Oxide Additives on Hydrogen Production in the Steam-Iron Process (철-수증기 반응에 의한 수소생성에 미치는 금속산화물의 첨가효과)

  • Lee, Dae-Haeng;Moon, Hee;Park, Heung-Chul
    • Applied Chemistry for Engineering
    • /
    • v.2 no.1
    • /
    • pp.30-37
    • /
    • 1991
  • The production of hydrogen from steam by reduced iron with additives such as CuO, $In_2O_3$, $MoO_3$ and $WO_3$ has been kinetically investigated. It was shown that all additives have a promoting effect on reaction activity in the order of $$MoO_3{\gg}In_2O_3{\sim_=}WO_3{\sim_=}CuO$$. The shrinking core model was applied to predict the complete conversion time and the results were quite comparable with experimental values. The reaction was carried out in a fixed flow reactor packed with reduced iron with 1 wt % of additives under the conditions, $600-750^{\circ}C$, Ar flow rate of 1 L/min and steam partial pressure of 0.085 atm. The apparent activation energies were 14.2, 20.9, 21.3, 22.4 and 27.9 kJ/mol with $MoO_3$, $In_2O_3$, $WO_3$, CuO and without additive, respectively.

  • PDF

A Design Method of Iron-cored CTs To Prevent Satruation (포화를 방지하기 위한 보호용 철심 변류기 설계 방법)

  • Lee, Ju-Hun;Gang, Sang-Hui;Gang, Yong-Cheol;Lee, Seung-Jae;Bae, Ju-Cheon;An, Jun-Gi;Lee, Cheong-Hak;Lee, Jeong-Taek
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.2
    • /
    • pp.119-126
    • /
    • 1999
  • Current transformer (CT) saturation may cause a variety of protective relays to malfunction. The conventional CT is designed that it can carry up to 20 times the rated current without exceeding 10% ratio error. However, the possibility of CT saturation still remains if the fault current contains substantial amounts of ac and/or dc components. This paper presents a design method of iron-cored CTs for use with protective relays to prevent CT saturation. The proposed design method determines the core cross section of the CT; it employs the transient dimensioning factor to consider relay's operating time (duty cycle) and dc component as well as ac components contained in the fault current, and symmetrical short-circuit current factor to consider as well as ac components contained in the fault current, and symmetrical short-circuit current factor to consider the biggest fault current. The method designs the cross section of CTs in cases of reclosure and no reclosure.

  • PDF

Compensation Algorithm for a Measurement Voltage Transformer (측정용 전압 변성기 오차 보상 알고리즘)

  • Kang, Yong-Cheol;Park, Jang-Min;Lee, Mi-Sun;Jang, Sung-Il;Kim, Yong-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.761-766
    • /
    • 2008
  • This paper describes a compensation algorithm for a measurement voltage transformer (VT) based on the hysteresis characteristics of the core. The error of the VT is caused by the voltages across the primary and secondary windings. The latter depends on the secondary current whilst the former depends on the primary current, i.e. the sum of the exciting current and the secondary current. The proposed algorithm calculates the voltages across the primary and secondary windings and add them to the measured secondary voltage for compensation. To do this, the primary and secondary currents should be estimated. The secondary current is obtained directly from the secondary voltage and used to calculate the voltage across the secondary winding. For the primary current, in this paper, the exciting current is decomposed into the two currents, i.e. the core-loss current and the magnetizing current. The core-loss current is obtained by dividing the primary induced voltage by the core-loss resistance. The magnetizing current is obtained by inserting the flux into the flux-magnetizing current curve. The calculated voltages across the primary and secondary windings are added to the measured secondary current for compensation. The proposed compensation algorithm improves the error of the VT significantly.

Preparation of chitosan, sunflower and nano-iron based core shell and its use in dye removal

  • Turgut, Esra;Alayli, Azize;Nadaroglu, Hayrunnisa
    • Advances in environmental research
    • /
    • v.9 no.2
    • /
    • pp.135-150
    • /
    • 2020
  • Many industries, such as textiles, chemical refineries, leather, plastics and paper, use different dyes in various process steps. At the same time, these industrial sectors are responsible for discharging contaminants that are harmful and toxic to humans and microorganisms by introducing synthetic dyes into wastewater. Of these dyes, methylene blue dye, which is classified as basic dyes, is accepted as a model dye. For this reason, methylene blue dye was selected in the study and its removal from the water was studied. In this study, two efficient biosorbents were developed from chitosan and sunflower waste, an agro-industrial waste and modified using iron nanoparticles. The biosorption efficiency was evaluated for methylene blue (MB) dye removal from aqueous solution under various parameters such as treating agent, solution pH, biosorbent dosage, contact time, initial dye concentration and temperature. We investigated the kinetic properties of dye removal from water for Chitosan-Sunflower (CS), Chitosan-Sunflower-Nanoiron (CSN). When the wavelength of MB dye was spectrophotometrically scanned, the maximum absorbance was determined as 660 nm. For the core shell biosorbents we obtained, we found that the optimum time for removal of MB from wastewater was 60 min. The pH of the best pH was determined as 5 in the studied pH. The most suitable temperature for the experiment was determined as 30℃. SEM-EDAX, TEM, XRD, and FTIR techniques were used to characterize biosorbents produced and modified in the experimental stage and to monitor the change of biosorbent after dye removal. The interactions of the paint with the surface used for removal were explained by these techniques. It was calculated that 80% of CS and 88% of CSN removed MB in optimum conditions. Also, the absorption of MB dye onto the surface was investigated by Langmiur and Frendlinch isotherms and it was determined from the results that the removal was more compatible with Langmiur isotherm.

Consideration of Making Techniques and Deterioration Assessment using Radiography for the Iron Buddha Statues (방사선 투과촬영을 활용한 철불의 손상도 평가 및 제작기법 고찰)

  • Han, Na Ra;Lee, Chan Hee;Yi, Jeong Eun
    • Journal of Conservation Science
    • /
    • v.30 no.1
    • /
    • pp.81-93
    • /
    • 2014
  • As the Seated Iron Buddha Statues, Vairocana Buddha of Dopiansa Temple in Cheolwon, Nosana Buddha of Samhwasa Temple in Donghae and Sakyamuni of Mangisa Temple in Pyeongtaek were made during Unified Silla to Koryo Dynasty. These are damaged degradation which are crack, break-out, peel off and various pollutant. As a result of deterioration evaluation using radiography, crack, gap, break-out, pore space and restoration material are confirmed inside in the Buddha Statues. Based on iron strength, the Buddha Statues will be maintain current state as long as a high external impact is not applied. Also, iron core and nails used for fixing of internal and external framework were observed in the Buddha Statues. According to prominent line of surface, embossed inscription, hands cast separately and combined, the Buddha Statues were made by using division casting.

Preparation of Al@Fe2O3 Core-Shell Composites Using Amphiphilic Graft Copolymer Template

  • Patel, Rajkumar;Kim, Sang Jin;Kim, Jin Kyu;Park, Jung Su;Kim, Jong Hak
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.209-213
    • /
    • 2014
  • A graft copolymer of poly(vinyl chloride)-g-poly(oxyethylene methacrylate) (PVC-g-POEM) was synthesized via atom transfer radical polymerization (ATRP) and used as a structure-directing agent to prepare $Al@Fe_2O_3$ core-shell nanocomposites through a sol-gel process. The amphiphilic property of PVC-g-POEM allows for good dispersion of Al particles and leads to specific interaction with iron ethoxide, a precursor of $Fe_2O_3$. Secondary bonding interaction in the sol-gel composites was characterized by Fourier transform-infrared (FT-IR) spectroscopy. The well-organized morphology of $Al@Fe_2O_3$ core-shell nanocomposites was observed using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Energy dispersive X-ray (EDX) and X-ray diffraction (XRD) were used to analyze the elemental composition and crystallization structure of the composites.

Loss analysis to the various kinds of core for PCS inductor and transformer (코어 종류에 따른 PCS 인덕터와 트랜스포머 손실 분석)

  • Yang, Seung-Dae;Shim, Jae-Hwe;Choi, Ju-Yeop;Song, Seung-Ho;Choy, Ick;An, Jin-Ung;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.22-30
    • /
    • 2011
  • In recently, inductor and transformer is the common device using widely in the photovoltaic system and power electronics. Therefore, each inductor and transformer has different core loss and iron loss depending on the size and kinds of core materials, it is important to analyze loss characteristics for better transformer efficiency. This paper offers an efficiency calculation method for PCS inductor and transformer loss, and different kinds of core materials are analyzed for optimized PCS design.

Demagnetization and Iron loss Analysis of the Single-Phase Flux Reversal Machine for High Speed drives (고속 구동용 단상 자속 역전식 전동기의 감자특성 및 철손분석)

  • Kim, Yong-Su;Kwon, Sam-Young;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.100-110
    • /
    • 2006
  • This paper presents the demagnetization and iron loss analysis of the single phase Flux Reversal Machine. It has a magnetic configuration similar to the switched reluctance machine but with multipole permanent magnets of alternate polarity on each stator salient pole embraced by concentrated coils. But it can be demagnetized by sudden over current and core losses increase because switching frequency is getting faster. This paper show demagnetization of permanent magnet and iron loss characteristic, and proposed a solution.