• Title/Summary/Keyword: ionizing energy

Search Result 179, Processing Time 0.02 seconds

Towards defining a simplified procedure for COTS system-on-chip TID testing

  • Di Mascio, Stefano;Menicucci, Alessandra;Furano, Gianluca;Szewczyk, Tomasz;Campajola, Luigi;Di Capua, Francesco;Lucaroni, Andrea;Ottavi, Marco
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1298-1305
    • /
    • 2018
  • The use of System-on-Chip (SoC) solutions in the design of on-board data handling systems is an important step towards further miniaturization in space. However, the Total Ionizing Dose (TID) and Single Event Effects (SEE) characterization of these complex devices present new challenges that are either not fully addressed by current testing guidelines or may result in expensive, cumbersome test configurations. In this paper we report the test setups, procedures and results for TID testing of a SoC microcontroller both using standard $^{60}Co$ and low-energy protons beams. This paper specifically points out the differences in the test methodology and in the challenges between TID testing with proton beam and with the conventional gamma ray irradiation. New test setup and procedures are proposed which are capable of emulating typical mission conditions (clock, bias, software, reprogramming, etc.) while keeping the test setup as simple as possible at the same time.

Monte-Carlo simulation for detecting neutron and gamma-ray simultaneously with CdZnTe half-covered by gadolinium film

  • J. Byun ;J. Seo ;Y. Kim;J. Park;K. Shin ;W. Lee ;K. Lee ;K. Kim;B. Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1031-1035
    • /
    • 2023
  • Neutron is an indirectly ionizing particle without charge, which is normally measured by detecting reaction products. Neutron detection system based on measuring gadolinium-converted gamma-rays is a good way to monitor the neutron because the representative prompt gamma-rays of gadolinium have low energies (79, 89, 182, and 199 keV). Low energy gamma-rays and their high attenuation coefficient on materials allow the simple design of a detector easier to manufacture. Thus, we designed a cadmium zinc telluride detector to investigate feasibility of simultaneous detection of gamma-rays and neutrons by using the Monte-Carlo simulation, which was divided into two parts; first was gamma-detection part and second was gamma- and neutron-simultaneous detection part. Consequently, we confirmed that simultaneous detection of gamma-rays and neutrons could be feasible and valid, although further research is needed for adoption on real detection.

Simulation-based analysis of total ionizing dose effects on low noise amplifier for wireless communications

  • Gandha Satria Adi;Dong-Seok Kim;Inyong Kwon
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.568-574
    • /
    • 2024
  • The development of radiation-tolerant radio-frequency (RF) systems can be a solution for applications in extreme radiation environments, such as nuclear power plant monitoring and space exploration. Among the crucial components within an RF system, the low noise amplifier (LNA) stands out due to its vulnerability to TID effects, mainly relying on transistors as its main devices. In this study, the TID effects in the LNA using standard 0.18 ㎛ complementary metal oxide semiconductors (CMOS) technology are estimated and analyzed. The results show that the LNA can withstand absorbed radiation up to 100 kGy. The S21, S11, noise figure (NF), stability (K), and linearity of the third input intercept point (IIP3) slightly shifted from the initial values of 0.8312 dB, 0.793 dB, 0.00381 dB, 1.34406, and 2.36066 dBm, respectively which are still comparable to the typical performances. Moreover, the standard 0.18 ㎛ technology has demonstrated its radiation tolerance, as it exhibits negligible performance degradation in the conventional LNA even when exposed to radiation levels up to 100 kGy. In this context, simulation approach offers a means to predict the TID effects and estimate the radiation exposure limit for electronic devices, particularly when transistors are used as the primary RF components.

Radiation Damage of Semiconductor Device by X-ray (엑스선에 의한 반도체 소자의 방사선 손상)

  • Kim, D.S.;Hong, H.S.;Park, H.M.;Kim, J.H.;Joo, K.S.
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.110-117
    • /
    • 2015
  • Recently, Due to the increased industry using radiation inspection equipment in the semiconductor, this demand of technology research is increasing. Although semiconductor inspection equipment is using low energy X-ray from 40 keV to 120 keV, Studies of radiation damage about the low energy X-ray are lacking circumstance in our country. Therefore, It is study that BJT (bipolar junction transistor) of one type of semiconductor elements are received radiation damage by low energy X-ray. BJT were used to the NXP semiconductor company's BC817-25 (NPN type), and Used the X-ray generator for the irradiation. Radiation damage of BJT was evaluated that confirm to analyse change of collector-emitter voltage of before and after X-ray irradiation when current gain fixed to 10. X-ray generator of tube voltage was setting 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp and irradiation time was setting 180s, 360s, 540s into 180s intervals. As the result, We confirmed radiation damage in BJT by low energy X-ray under 120 keV energy, and Especially the biggest radiation damage was appeared at the 80 kVp. It is expected that ELDRS (enhanced low dose rate sensitivity) phenomenon occurs on the basis of 80 kVp. This studies expect to contribute effective dose administration of semiconductor inspection equipment using low energy X-ray, Also Research and Development of X-ray filter.

Alterations in the Properties of Agar by ionizing Radiation

  • Lee, Su-Rae;Park, Sang-Ki;Cho, Han-Ok
    • Nuclear Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.145-150
    • /
    • 1976
  • Alkali-treated red algae, Gracilaria sp. was irradiated with various doses of cobalt-60 gamma-rays and the yeild and properties of agar extracted from the seaweed were examined and compared with the quality of commercial agar powder after irradiation. Extraction yield of agar from irradiated seaweed was proportionally increased as the radiation dose was raised up to 2 Mrad whereas it tended to decrease slightly thereafter. Gelation ability, gelation point, gel hardness and specific viscosity of the agar were increased up to 1 Mrad and decreased at higher dose levels while its melting point, total nitrogen, crude ash and total sulfur decreased up to 1 Mrad level and remained unchanged thereafter. Irradiation of commercial agar powder caused remarkable decreases in the gelation ability, specific viscosity and gel hardness and slight decreases in the gelation point and melting point. The pattern of alterations in the properties of agar samples differed whether the polysaccharide was irradiated in free state or bound state in seaweed.

  • PDF

Effects of Ionizing Radiation on Sprout Inhibition and Nutritive Value of Potato Tubers (방사선(放射線) 조사(照射)가 감자 괴경(塊莖)의 맹아억제(萌芽抑制) 및 영양가(營養價)에 미치는 영향(影響))

  • Lee, Mie-Soon;Kim, Hong-Lyour
    • Korean Journal of Food Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.29-35
    • /
    • 1972
  • Effects of various dosages of gamma ray ranging from 0 to 16 krad on sprout inhibition and nutritive value of potato tubers were investigated with Irish Cobbler variety. Sprout growth was gradually suppressed with increasing dosage, and completely inhibited with 16 krad treatment. Under this optimum dosage, weight loss of tubers was markedly reduced and tubers kept firm throughout the 2 month storage period. Irradiation had no adverse effects on the cooking quality of potato tubers. Moisture content of stored potato tubers was shown to be in inverse proportion to sprout growth. Tubers treated with 16 krad tended to contain somewhat higher percentage of total carbohydrate than those treated with lower dosages. Significantly larger amounts of ascorbic acid were retained in 8 and 16 krad treatments than in 0 and 2 krad treatments.

  • PDF

Effect of Cobaltous Chloride on the Repair of UV-induced DNA Damage (UV에 의해 손상된 DNA 회복에 미치는 cobaltous chloride의 효과)

  • Kim, Kug-Chan;Kim, Yung-Jin;Lee, Kang-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.71-78
    • /
    • 1995
  • To develop methods to reduce radiation risk and apply such knowledge to improvement of radiation protection, the effects of cobaltous chloride known as bioantimutagen on the function of E. coli RecA protein involved in the repair of DNA damage were examined. The results demonstrated two distinct effects of cobaltous chloride on the RecA protein function necessary for the strand exchange reaction. Cobaltous chloride enhanced the ability of RecA protein to displace SSB protein from single-stranded DNA and the duplex DNA-dependent ATPase activity. RecA protein was preferentially bound with UV-irradiated supercoiled DNA as compared with nonirradiated DNA The binding of RecA protein to UV-irradiated supercoiled DNA was enhanced in a dose-dependent manner. It is likely that studies on the factors affecting repair efficiency and the DNA repair proteins may provide information on the repair of ionizing radiation-induced DNA damage and the mechanism for DNA radioprotection.

  • PDF

Effects of Ionizing Energy on the Decontamination and Quality of Mixed Condiment (전리(電離)에너지가 혼합(混合) 조미료(調味料)의 살균(殺菌) 및 품질(品質)에 미치는 영향(影響))

  • Yoon, Hyung Sik;Kwon, Joong Ho
    • Current Research on Agriculture and Life Sciences
    • /
    • v.4
    • /
    • pp.65-69
    • /
    • 1986
  • The radurization and radicidation effects on mixed condiment with Co-60 gamma irradiation at 3-9kGy and the physicochemical aspects of irradiated samples stored at $30^{\circ}C$ for three months were investigated. The initial microbial loads of the sample were $7.5{\times}10^5/g$ in total bacterial count and $1.2{\times}10^2/g$ in coliforms, respectively. The irradiation treatment of below 9 kGy could decontaminate the sample and $D_{10}$ value of the bacteria contaminated was shown to be 1.94 kGy. The chemical components associated with the quality of the sample were little affected by the irradiation at 3-6kGy. The sensory evaluation showed that the high sterilizing dose caused appreciably the change in overall flavors of mixed condiment.

  • PDF

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

Optical, thermal and gamma ray attenuation characteristics of tungsten oxide modified: B2O3-SrCO3-TeO2-ZnO glass series

  • Hammam Abdurabu Thabit;Abd Khamim Ismail;M.I. Sayyed;S. Hashim;I. Abdullahi;Mohamed Elsafi;K. Keshavamurthy;G. Jagannath
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.247-256
    • /
    • 2024
  • The glass series modified by tungsten oxide was created using the compounds (75-x) B2O3- 10SrCO3- 8TeO2- 7ZnO - xWO3, where x = 0, 1, 5, 10, 22, 27, 34, and 40% mole percentage. A UV-visible spectrophotometer and thermogravimetric-differential thermal analysis (TG-DTA) methods were employed to characterize the specimen's optical and phase transition attributes, respectively. The mass-attenuation coefficient (AC) of all created glasses from BSTZW0 to BSTZ7 was estimated using Geant4 code from 0.05 to 3 MeV and compared to the XCOM software results, with a relative difference of less than 2% between the two results. The increase of WO3 percentage lead to an increase in the Linear-AC at each studied energy, and this is mainly due to the fact that the higher the percentage of WO3 in the glass increases its density which causes an increase in the Linear-AC, so an energy of 0.06 MeV, as an example, the values of the Linear-AC was 4.009, 4.509, 5.442, 6812, 8.564, 9.856, 10.999 and 11.628 cm-1 form BSTZW0 too BSTZW7, respectively. The Half-VL (value layer), Mean-FP (free path), Tenth-VL, and Radiation attenuation performance (RAP) were also calculated for the current BSTZW-glass samples and revealed that BSTZW7 had the best gamma ray attenuation performance at all discussed energies when compared to other studied glass samples.