• 제목/요약/키워드: ionizing energy

검색결과 172건 처리시간 0.028초

단자엽 모델 식물의 이온화 에너지원에 따른 생리 활성 (Physiological Characterization of Mono-Cotyledonous Model Plant by Ionizing Irradiation)

  • 송미라;김선희;장덕수;강시용;김진백;김상훈;하보근;박용대;김동섭
    • 방사선산업학회지
    • /
    • 제5권1호
    • /
    • pp.7-13
    • /
    • 2011
  • The present study has been performed to compare the physiological analysis of monocot model plant (rice) in response to ionizing irradiations (cosmic-ray, gamma-ray, and Ion beam). Ionizing radiations were implanted into monocot model plant (rice) seed. After irradiation, the seeds were planted in the plastic pots for a growth period of one month. Thereafter, the morphological and physiological characteristics including malondealdehyde (MDA) and chlorophyll content, activities of antioxidant enzymes in irradiation samples were investigated. We are confirmed that the activity level of MDA and chlorophyll content were not changed by ionizing irradiation samples. However, the free radical contents were increased in all irradiated plants. And the activities of SOD, POD, and APX were significantly increased by irradiation compared with non-irradiation plant.

버섯의 갈변 및 색도에 대한 전리에너지의 영향 (Browning end Color Characteristics in Mushrooms (Agaricus bisporus) As Influenced by ionizing Energy)

  • 권중호;변명우;조한옥
    • 한국식품과학회지
    • /
    • 제22권5호
    • /
    • pp.509-513
    • /
    • 1990
  • 백색종 양송이의 보존기간 연장을 위한 전리에너지 처리가 저장중 버섯의 갈변현상과 색도에 미치는 영향을 조사하였다. 버섯의 갈변현상과 관련된 polyphenol성 화합물은 저장 중 $(9{\pm}1^{\circ}C,\;80{\pm}7%\;RH$, 20일간) 감소하였고 갈변색소는 저장 후 3일경부터 크게 증가하였으며, 이들의 증감현상은 2-3kGy의 감마선 조사로서 유의적으로 감소되었다. 포장된(종이상자와 PE) 버섯의 갓 및 줄기 부위의 표피와 내부조직에 대한 기계적 색도 측정에서 감마선은 처리직후 Hurter L값(백색도)의 감소와 a 및 b값(적색도 및 황색도)의 증가현상을 초래하였으나 저장 후 15일까지 버섯의 변색방지 효과를 뚜렷이 나타내었다. 이 같은 효과는 줄기에 비해 갓 부분에서 높았으며 조사선량(1-3kGy)에도 비례하였다.

  • PDF

이온화 에너지를 조사한 수입 오렌지의 유전독성학적 안전성 평가 (Genotoxicological Safety Evaluation of Imported Oranges Irradiated with Ionizing Energy)

  • 황옥화;정다운;강일준
    • 한국식품영양과학회지
    • /
    • 제43권6호
    • /
    • pp.909-915
    • /
    • 2014
  • 본 연구에서는 방사선 조사 오렌지의 수입 가능성이 높아짐에 따라 이들의 안전성을 검토할 목적으로 0.5, 1 kGy 감마선 조사 수입 오렌지의 복귀돌연변이 시험, 소핵 및 염색체 이상시험의 유전독성학적 안전성 평가를 수행하였다. S. Typhimurium TA98, TA100, TA1535 및 TA1537에 대한 감마선 조사 수입 오렌지(0.5, 1 kGy)의 복귀변이 집락수를 조사한 결과, 대사활성계 도입 및 부재 시 0.625~10 mg/plate의 범위에서 복귀변이 집락수의 농도 의존적인 증가 혹은 감소를 보이지 않았다. 포유류 배양세포를 이용한 염색체이상시험에서 0.5, 1 kGy 감마선 조사 수입 오렌지는 1.25~10 mg/mL의 시험적용 용량에서 염색체이상 유발능이 5% 미만이어서 염색체이상을 유발하지 않는 것으로 나타났다. 설치류 망상적혈구를 이용한 소핵형성 시험을 수행한 결과, 시험적용 용량인 250~2,000 mg/kg의 범위에서 0.5, 1 kGy 감마선 조사 수입 오렌지는 소핵을 가진 망상적혈구의 출현율이 음성대조군과 유의한 차이를 나타내지 않아 소핵을 유발하지 않음을 확인하였다. 이상의 결과, 0.5, 1 kGy 감마선 조사 수입 오렌지는 본 시험조건에서 유전독성이 없는 것으로 나타났다.

Effect of the Storage Temperature, Duration and Gamma Irradiation on the Respiration Rate and Sugar Content of Minituber 'Superior'

  • Lim, Ji-Hyeok;HwangBo, Jun-Kwon;Baek, Myung-Hwa;Kim, Jin-Hong;Kim, Jae-Sung;Lee, Myung-Chul
    • 한국환경농학회지
    • /
    • 제24권1호
    • /
    • pp.61-65
    • /
    • 2005
  • This study was to evaluate whether ionizing gamma radiation could be applied to break the dormancy of a potato minituber. The respiration rate of the minitubers was significantly affected by the storage temperature and a low dose gamma radiation. Ionizing radiation of 8 Gy enhanced the respiration rate of the potato tuber stored at $10^{\circ}C$ for 20 days. The potato tuber subjected to 4 and 8 Gy after 40 days storage at 10 and $20^{\circ}C$ exhibited higher respiration rates compared to the control (non-irradiated), but not at st. However, the ionizing radiation did not exhibit on significant effect on the respiration rate of the potato tuber stored for 60 days. It was observed that minitubers stored for 20 days had significant response to the storage temperature in terms of the total sugar content the higher the storage temperature, the lower the total sugar content. It was measured that the reducing sugar content was increased under the storage conditions both 5 and $10^{\circ}C$ for 40 days, but not to $20^{\circ}C$. The total sugar contents in the minituber stored for 60 days were similar to those stored for 40 days. The data was discussed on the relationships among the storage duration, temperature and ionizing radiation.

이온화 방사선 및 염화수은 처리에 따른 어류 간암세포의 생존능 평가 (Synergistic Effects of Ionizing Radiation and Mercury Chloride on Cell Viability in Fish Hepatoma Cells)

  • 한민;현경만;모하마드닐리;황인영;김진규
    • 환경생물
    • /
    • 제27권2호
    • /
    • pp.140-145
    • /
    • 2009
  • All organisms are being exposed to harmful factors present in the environmental. The combined action of various factors is a distinguishing feature of modern life. An interaction between two chemicals is considered as synergistic when the effect produced is greater than the sum of the two single responses. The biological effects due to the combined action of ionizing radiation with the other factor are hard to estimate and predict in advance. In the current study, we investigated the synergistic effects between ionizing and $HgCl_2$ using fish hepatoma cells (PLHC-1 cells). The results showed a dramatic decrease of cell viability after simultaneous treatment of PLHC-1 cells with ionizing radiation and $HgCl_2$. Neiither of the two had any cytotoxic effect when treated alone. The cytotoxicity of ionizing radiation was enhanced in the presence of $HgCl_2$. The synergistic effects were observed after exposure of the PLHC-1 cells to ionizing radiation combined with $HgCl_2$. The synergistic interaction was due to an increase of irreversibly damaged cells after the combined exposure. Analysis of the extent of synergistic interaction enables to make quantitative estimation of irreversibly damaged cells after the combined exposure. The present study suggests that PLHC-1 cells can serve as rapid screening tools for detecting the toxicity of harmful factors.

A Proposal on Evaluation Method of Neutron Absorption Performance to Substitute Conventional Neutron Attenuation Test

  • Kim, Jae Hyun;Kim, Song Hyun;Shin, Chang Ho;Choe, Jung Hun;Cho, In-Hak;Park, Hwan Seo;Park, Hyun Seo;Kim, Jung Ho;Kim, Yoon Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.384-388
    • /
    • 2016
  • Background: For a verification of newly-developed neutron absorbers, one of guidelines on the qualification and acceptance of neutron absorbers is the neutron attenuation test. However, this approach can cause a problem for the qualifications that it cannot distinguish how the neutron attenuates from materials. Materials and Methods: In this study, an estimation method of neutron absorption performances for materials is proposed to detect both direct penetration and back-scattering neutrons. For the verification of the proposed method, MCNP simulations with the experimental system designed in this study were pursued using the polyethylene, iron, normal glass and the vitrified form. Results and Discussion: The results show that it can easily test neutron absorption ability using single absorber model. Also, from simulation results of single absorber and double absorbers model, it is verified that the proposed method can evaluate not only the direct thermal neutrons passing through materials, but also the scattered neutrons reflected to the materials. Therefore, the neutron absorption performances can be accurately estimated using the proposed method comparing with the conventional neutron attenuation test. Conclusion: It is expected that the proposed method can contribute to increase the reliability of the performance of neutron absorbers.

전리방사선 센서용 MOS Capacitors의 구조적 변화에 따른 감도 특성 분석 (Sensitivity Analysis of the Structural Characteristics of the MOS Capacitors for Sensing the Ionizing Radiation Effects)

  • 황영관;이남호;이현진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1181-1182
    • /
    • 2008
  • The study presents the results of the analysis on the structural characteristics of MOS capacitor for sensing the ionizing radiation effect. Increasing the thickness of MOS capacitor's oxide layer enhanced the sensitivity of MOS capacitor under irradiation condition, but the sensitivity of irradiated MOS capacitor is uninfluenced by the area of MOS capacitor.

  • PDF

기준 베타선장의 에너지 스펙트럼 측정 (The Measurement of National Standard ${\beta}$-Rays Energy Spectrum)

  • 김철항;이철영;김현문;하석호;전국진
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.285-291
    • /
    • 2012
  • Si(Li) 검출기를 이용해 한국표준과학연구원에서 보유한 베타선 선원인 $^{147}Pm$, $^{85}Kr$, $^{90}Sr+^{90}Y$ 선원의 순수 베타선 에너지 스펙트럼을 측정하였고 이 측정 스펙트럼에 대한 잔여에너지와 질량충돌저지능비를 산출하였다. 베타선의 잔여에너지는 $^{147}Pm$, $^{85}Kr$, $^{90}Sr+^{90}Y$ 선원에 대하여 각각 0.14, 0.57, 0.93 MeV으로 평가되었고 질량충돌저지능비는 각각 1.123, 1.120, 1.109이었다.

CURRENT TRENDS IN IONIZING RADIATION DETECTION

  • Wehe David K.
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.311-318
    • /
    • 2006
  • Ionizing radiation is a both a natural and man-made phenomena that plays a major role in contemporary applications. The detection of this radiation has evolved over the past several decades from simple observations to precise measurements in space, time, and energy, even in harsh environmental conditions. Tn this paper, we present a snapshot of the current state-of-the-art in radiation measurement technology, highlighting the major applications and detector developments.