• Title/Summary/Keyword: ionic s

Search Result 802, Processing Time 0.028 seconds

Enhancement of the Ionic Conductivity and Mechanical Strength of Micro-porous Separator by Uni-axial Drawing

  • Lee Je-An;Seol Wan-Ho;Lee Yong-Min;Park Jung-Ki
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.1
    • /
    • pp.29-33
    • /
    • 2006
  • A new porous separator based on poly(vinyl chloride) (PVC)/poly(vinylidene fluoride-co-hexafluoro-propylene) (P(VdF-co-HFP)/poly(methyl methacrylate) (PMMA) was prepared by a phase inversion method. To enhance mechanical property, the membrane was stretched uniaxially at high temperature. Tensile strength and ionic conductivity were measured for various draw ratios. The tensile strength and ionic conductivity were increased with increasing draw ratio. The tensile strength of the separator reached 52MPa after stretching to draw ratio of 5, and the ionic conductivity of the separator was increased from $1.9Xs10^{-4}S/cm\;to\;4.6X10^{-4}S/cm\;at\;25^{\circ}C$. The stretched separator immersed in liquid electrolyte was electrochemically stable up to 4.7 V. The cell based on the stretched separator was maintained at about 99% of the initial discharge capacity after 10th cycle operation at 0.2C rate.

XPS Investigation of A3 Coupling Reaction in Room Temperature Ionic Liquids

  • Kwon, Ji-Hye;Youn, So-Won;Kang, Yong-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.11
    • /
    • pp.1851-1853
    • /
    • 2006
  • We herein report a new analytical application of XPS to the identification of organic molecules in room temperature ionic liquid for the first time. An organic compound, propargylamine (1), produced in 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim][$PF_6$]), which is one of the room temperature ionic liquids (RTILs), via $A^3$ coupling reaction, is characterized by means of x-ray photoelectron spectroscopy (XPS) rather than using conventional organic compound analysis techniques. There are four non-equivalent carbons in RTILs and 1 each. The ratios of normalized integrated areas of the deconvoluted binding energy of core electron of carbon (C1s) peaks are well matched to the number of carbons in those compounds. The binding energies of C1s of the featured carbons in 1, C4 (sp carbons in acetylene group) and C5 ($sp^2$ carbons in benzene ring), are assigned 286.2 and 285.4 eV, respectively. These results will be able to provide an important tool and a new strategy for the analysis of organic molecules

Photosynthetic Patterns of 3 Crassulacean Plants under Drought Conditions

  • Kim, Tae-Jin;Choo, Yeon-Sik
    • Journal of Ecology and Environment
    • /
    • v.30 no.2
    • /
    • pp.187-193
    • /
    • 2007
  • Higher plants can be categorized as C3, C4 or CAM according to their photosynthetic pathways, and some succulent plants are known to shift their patterns of photosynthesis from C3 to CAM in response to environmental stresses such as salt treatment or water deficiency. To investigate fundamental photosynthetic patterns and the induction of pattern shifts (C3, CAM, C3-CAM etc.) as a result of environmental stresses, we measured the water content, diurnal changes in pH, net $CO_2$ exchange, transpiration rate, total ionic contents, and osmolality of Kalancoe daigremontiana, Sedum kamschaticum and Sedum sarmentosum which belong to Crassulaceae known as representative CAM plant, after 10 days of drought treatment. S. kamschaticum and S. sarmentosum did not show a significant difference in diurnal pH variation in the treatment and control conditions. However, the pH of drought-treated Kalancoe was low at night and high in the daytime, with a pH value between 4 and 5. Typical CAM plants display a net $CO_2$ exchange that increases at night and decreases in the daytime. Kalancoe displayed the predicted pattern. However, S. kamschaticum and S. sarmentosum showed a photosynthetic pattern more typical of C3 plants, and did not show changes in photosynthetic pattern under drought stress. Kalancoe also showed a transpiration rate typical for CAM pho-tosynthesis, whereas the transpiration rates of S. kamschaticum and S. sarmentosum were in the typical range for C3 photosynthesis. Kalancoe had high total ionic contents during the night, which decreased somewhat during the daytime, whereas S. kamschaticum and S. sarmentosum displayed the opposite pattern. This result is similar to the diurnal patterns of changes in pH in the three plant species, which suggests a relationship between pH and ionic contents. S. sarmentosum showed lower osmolality under drought stress than in the control condition, whereas the osmolality of Kalancoe and S. kamschaticum did not differ between conditions. S. sarmentosum may have maintained internal water content by lowering its osmolality and raising its total ionic contents. In conclusion, Kalancoe displayed the characteristic responses of a typical CAM plant, whereas S. kamschaticum and S. sarmentosum displayed aspects of the C3 photosynthetic pattern under drought conditions. These results suggest that S. kamschaticum and S. sarmentosum (Crassulacea) in Korea overcome drought stress by increasing solute and ionic contents internally rather than changing their photosynthetic pattern from C3 to CAM under drought stress.

Electrochemical properties of PEO-based solid polymer electrolytes blended with different room temperature ionic liquids

  • Kim, Y.H.;Cheruvally, G.;Choi, J.W.;Ahn, J.H.;Kim, K.W.;Ahn, H.J.;Song, C.E.;Choi, D.S.
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.276-276
    • /
    • 2006
  • The incorporation of room temperature ionic liquids (IL) in poly (ethyleneoxide)-lithium salt (PEO-LiX) based solid polymer electrolytes is presently being studied as an effective means of enhancing the room temperature ionic conductivity of these electrolytes to acceptable levels for use in lithium batteries. In the present study, $PEO_{20}-LiTFSI$ solid polymer electrolyte was blended with three different ionic liquids, namely 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide (BMIMTFSI), 1-butyl-3-methylimidazolium tetraflouroborate (BMIMBF4) and 1-butyl-3-methylimidazolium trifluromethanesulfonate ($BMIMCF_{3}SO_{3}$). The incorporation of all these ILs resulted in the enhancement of ionic conductivity, the effect being more pronounced at lower temperatures. Electrochemical properties of the blended electrolytes were studied by cyclic voltammetry, linear sweep voltammetry and interfacial resistance measurements. The optimum results were obtained with the blending of BMIMTFSI in the solid polymer electrolyte.

  • PDF

Physical Properties of Lithium Co-polyelectrolyte Based on Imidazolium and Ammonium-type Ionic Liquids

  • Cha, E.H.;Lim, S.A.;Kim, D.W.;Lee, J.K.;Park, J.H.
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.3
    • /
    • pp.198-202
    • /
    • 2010
  • Lithium co-polyelectrolyte-ionic liquid systems, using poly (lithium 2-acrylamido-2-methyl propanesulfonate; PAMPSLi) and polyvinyl formamid (PVF) were prepared and their electrochemical and physical properties were measured. The conductivity of co-polymer systems, PAMPSLi/PVF/N, N-dimethyl-N-propyl-N-butylammonium tricyanomethanide (PAMPSLi/PVF/$N_{1134}$TCM) and PAMPSLi/PVF/N, N-dimethyl-N-propyl-N-butylammonium dicyanamide (PAMPSLi/PVF/$N_{1134}$DCA) exhibited low viscosity ($N_{1134}$TCM:$N_{1134}$DCA 28.6cP, 28.7cP) and higher conductivity ($2.48{\times}10^{-3}Scm^{-1}$, $2.2{\times}10^{-3}Scm^{-1}$) than homopolymer system. The ionic conductivity PAMPSLi/PVF/1-ethyl-3-methyl imidazolium dicyanamide (PAMPSLi/PVF/emImDCA) exhibited $1.54{\times}10^{-3}Scm^{-1}$ and low viscosity (emImDCA: 28.09cP). High flexibility of imidazolium cation and dissociation of lithium cation from the co-polymer chains were affected by high conductivity and low viscosity.

A study on composite membranes based on hydrocarbon polymers and ionic liquids for high temperature PEFCs (고온 PEFCs를 위한 탄화수소계열 고분자와 이온성 액체를 함유하는 복합막에 관한 연구)

  • Baek, Ji-Suk;Park, Jin-Soo;Kim, Kyung-Hyun;Moon, Gi-Young;Kim, Hye-Kyung;Choi, Young-Woo;Park, Go-Gun;Yang, Tae-Hyun;Kim, Chang-Soo;Shul, Young-Gun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.147-148
    • /
    • 2009
  • The water-like ionic liquids have been widely used to enable the proton conduction in ionic liquid based membranes at high temperature and anhydrous PEFCs. In this study, we synthesized various kinds of composite membranes based on hydrocarbon polymers having good thermal and mechanical stabilities at high temperatures and ionic liquids. The composite membrane consisting of hydrocarbon polymer and ionic liquid was characterized by thermogravimetric analyzer (TGA) and impedance spectroscopy. Consequently the non-aqueous composite membranes of a variety of hydrocarbon polymer and ionic liquids have good conductivity and thermal stability at high temperature conditions.

  • PDF

Dispersion Characteristics of Zinc Oxide Nanoparticles in Ionic and Non-ionic Isotonic Solution (이온성 및 비이온성 등장액 용매에서 산화아연나노입자의 분산 특성)

  • Choi, Jonghye;Kim, Hyejin;Park, Kwangsik
    • YAKHAK HOEJI
    • /
    • v.57 no.4
    • /
    • pp.282-288
    • /
    • 2013
  • Zinc oxide nanoparticles (ZnONPs) are widely used in a variety of products and cosmetic products including paper, paints, plastics and sunscreen. However, information on the safety of ZnONPs are not enough and many publications suggest possible toxic effects on environmental and human health. Furthermore, physico-chemical characteristics of nanoparticles makes it hard to test toxicity using the test guidelines of chemicals adopted by regulatory bodies. In this study, stability of ZnONPs was investigated using different types of isotonic solution, which is important in the toxicity study of intravenous route. Precipitation, aggregation, size, zeta potential and morphology of ZnONPs were evaluated with different times and concentrations. Precipitation of ZnONPs were observed in ionic isotonic solution including phosphate-buffered saline, Kreb's-Ringer solution, physiological salt solution and cell culture media of DMEM (Dulbecco's Modified Eagle's Medium) with 10% fetal bovine serum. On the other hand, they were stable without precipitation in non-ionic isotonic solution such as 5% glucose and 2% glycerol, respectively, which are biocompatible for intravenous injection. The average size of ZnONPs in 5% glucose and 2% glycerol was stably maintained, which is less than 30 nm and very similar as that in water dispersion of ZnONPs, provided by the manufacturer. The stability was maintained during the experimental period of 5 days and diluted state up to 15,000 ppm. These data suggest that 5% glucose and 2% glycerol solution can be used for the vehicles of ZnONPs in the toxicity study of intravenous injection route.

Polymeric Gel Electrolytes for Electric Double Layer Capacitors (전기이중층 캐패시터에 관한 폴리머 겔 전해액)

  • Morita, Masayuki;Qiao, Jin-Li
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.141-144
    • /
    • 2003
  • Proton conducting polymeric gels as the electrolytes of electrochemical capacitors have been prepared by two different methods: 1) swelling a polymethacrylate-based polymer matrix in aqueous solutions of inorganic and organic acids, and 2) polymerizing complexes of anhydrous acids and prepolymers with organic plasticizer. The FT-IR spectra strongly suggest that the carbonyl groups in the polymer matrix interact with protons from the doped acids. High ionic (proton) conductivity in the range of $6\times10^{-4}-4\times10^{-2}\;S\;cm^{-1}$ was obtained at room temperature for the aqueous gels. The non-aqueous polymer complexes showed rather low ionic conductivity, but it was about $10^{-3}\;S\;cm^{-1}\;at\;70^{\circ}C$ for the $H_3PO_4$ doped polymer electrolyte. The mechanisms of ion (proton) conduction in the polymeric systems are discussed.

Statistical Analysis of Ion Components in Rainwater (濕性大氣成分에 對한 統計的解析)

  • 李敏熙;韓義正;元良洙;辛燦基
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.41-54
    • /
    • 1986
  • Methods used for averaging PH's of rainwater and site representation have been studied, Statistical analysis was attempted regarding effects of ionic components on PH's utilizing 847 data altogether obtained in two years, 1984 and 1985. The outcome of the study may be assumarized as follows: 1. Methods for Averaging PH Volume weighted method is considered to be acceptable providing that precipitation is measured at the same time when the samples are taken. Without precipitation data a simple averaging method should be the next choice. 2. Site Representation A statistical method used for optimizing a monitoring newtork was applied using the data collected. Because of a limited number of data, no discernible conclusion can be reached suggesting that the method can serve as a good guide when the data base becomes more reliable. 3. A good correlation appears to exist betwen conductivities and ionic components in rainwater. It would, therefore, be possible to certain extend to estimate ionic concentrations from conductivity measurements by correlation equations. 4. The acidity of rainwater is effected by $SO_4^{2-}, NO_3^-, Cl^- and NH_4^+ with SO_4^{2-}$ being the most significant as demonstrated by standardized regression analysis.

  • PDF

Electrohydrodynamic Characteristics of AC Corona Discharge for the Frequency (교류 코로나 방전시 주파수 변화에 따른 전기유체역학적 특성)

  • Jung, Jae-Seung;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.87-92
    • /
    • 2012
  • In this paper, EHD(electrohydrodynamics) characteristics of AC corona discharge for the various frequency was investigated. Ionic wind velocity is controlled by the frequency of applied ac high voltage, and maximum velocity of the ionic wind is obtained at 1.2kHz. Maximum velocity are 1.90 m/s by metal corona electrode and 2.72m/s by wet porous corona electrode, These attain 91~99% of the maximum velocity in the DC corona discharge by adjusting the frequency through the experiments. In this paper, wet porous corona electrode has high possibility of cooling methode because a AC corona discharge using wet porous corona electrode is able to eject more water droplets than DC corona discharge.