A new porous separator based on poly(vinyl chloride) (PVC)/poly(vinylidene fluoride-co-hexafluoro-propylene) (P(VdF-co-HFP)/poly(methyl methacrylate) (PMMA) was prepared by a phase inversion method. To enhance mechanical property, the membrane was stretched uniaxially at high temperature. Tensile strength and ionic conductivity were measured for various draw ratios. The tensile strength and ionic conductivity were increased with increasing draw ratio. The tensile strength of the separator reached 52MPa after stretching to draw ratio of 5, and the ionic conductivity of the separator was increased from $1.9Xs10^{-4}S/cm\;to\;4.6X10^{-4}S/cm\;at\;25^{\circ}C$. The stretched separator immersed in liquid electrolyte was electrochemically stable up to 4.7 V. The cell based on the stretched separator was maintained at about 99% of the initial discharge capacity after 10th cycle operation at 0.2C rate.
We herein report a new analytical application of XPS to the identification of organic molecules in room temperature ionic liquid for the first time. An organic compound, propargylamine (1), produced in 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim][$PF_6$]), which is one of the room temperature ionic liquids (RTILs), via $A^3$ coupling reaction, is characterized by means of x-ray photoelectron spectroscopy (XPS) rather than using conventional organic compound analysis techniques. There are four non-equivalent carbons in RTILs and 1 each. The ratios of normalized integrated areas of the deconvoluted binding energy of core electron of carbon (C1s) peaks are well matched to the number of carbons in those compounds. The binding energies of C1s of the featured carbons in 1, C4 (sp carbons in acetylene group) and C5 ($sp^2$ carbons in benzene ring), are assigned 286.2 and 285.4 eV, respectively. These results will be able to provide an important tool and a new strategy for the analysis of organic molecules
Higher plants can be categorized as C3, C4 or CAM according to their photosynthetic pathways, and some succulent plants are known to shift their patterns of photosynthesis from C3 to CAM in response to environmental stresses such as salt treatment or water deficiency. To investigate fundamental photosynthetic patterns and the induction of pattern shifts (C3, CAM, C3-CAM etc.) as a result of environmental stresses, we measured the water content, diurnal changes in pH, net $CO_2$ exchange, transpiration rate, total ionic contents, and osmolality of Kalancoe daigremontiana, Sedum kamschaticum and Sedum sarmentosum which belong to Crassulaceae known as representative CAM plant, after 10 days of drought treatment. S. kamschaticum and S. sarmentosum did not show a significant difference in diurnal pH variation in the treatment and control conditions. However, the pH of drought-treated Kalancoe was low at night and high in the daytime, with a pH value between 4 and 5. Typical CAM plants display a net $CO_2$ exchange that increases at night and decreases in the daytime. Kalancoe displayed the predicted pattern. However, S. kamschaticum and S. sarmentosum showed a photosynthetic pattern more typical of C3 plants, and did not show changes in photosynthetic pattern under drought stress. Kalancoe also showed a transpiration rate typical for CAM pho-tosynthesis, whereas the transpiration rates of S. kamschaticum and S. sarmentosum were in the typical range for C3 photosynthesis. Kalancoe had high total ionic contents during the night, which decreased somewhat during the daytime, whereas S. kamschaticum and S. sarmentosum displayed the opposite pattern. This result is similar to the diurnal patterns of changes in pH in the three plant species, which suggests a relationship between pH and ionic contents. S. sarmentosum showed lower osmolality under drought stress than in the control condition, whereas the osmolality of Kalancoe and S. kamschaticum did not differ between conditions. S. sarmentosum may have maintained internal water content by lowering its osmolality and raising its total ionic contents. In conclusion, Kalancoe displayed the characteristic responses of a typical CAM plant, whereas S. kamschaticum and S. sarmentosum displayed aspects of the C3 photosynthetic pattern under drought conditions. These results suggest that S. kamschaticum and S. sarmentosum (Crassulacea) in Korea overcome drought stress by increasing solute and ionic contents internally rather than changing their photosynthetic pattern from C3 to CAM under drought stress.
Kim, Y.H.;Cheruvally, G.;Choi, J.W.;Ahn, J.H.;Kim, K.W.;Ahn, H.J.;Song, C.E.;Choi, D.S.
Proceedings of the Polymer Society of Korea Conference
/
2006.10a
/
pp.276-276
/
2006
The incorporation of room temperature ionic liquids (IL) in poly (ethyleneoxide)-lithium salt (PEO-LiX) based solid polymer electrolytes is presently being studied as an effective means of enhancing the room temperature ionic conductivity of these electrolytes to acceptable levels for use in lithium batteries. In the present study, $PEO_{20}-LiTFSI$ solid polymer electrolyte was blended with three different ionic liquids, namely 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide (BMIMTFSI), 1-butyl-3-methylimidazolium tetraflouroborate (BMIMBF4) and 1-butyl-3-methylimidazolium trifluromethanesulfonate ($BMIMCF_{3}SO_{3}$). The incorporation of all these ILs resulted in the enhancement of ionic conductivity, the effect being more pronounced at lower temperatures. Electrochemical properties of the blended electrolytes were studied by cyclic voltammetry, linear sweep voltammetry and interfacial resistance measurements. The optimum results were obtained with the blending of BMIMTFSI in the solid polymer electrolyte.
Lithium co-polyelectrolyte-ionic liquid systems, using poly (lithium 2-acrylamido-2-methyl propanesulfonate; PAMPSLi) and polyvinyl formamid (PVF) were prepared and their electrochemical and physical properties were measured. The conductivity of co-polymer systems, PAMPSLi/PVF/N, N-dimethyl-N-propyl-N-butylammonium tricyanomethanide (PAMPSLi/PVF/$N_{1134}$TCM) and PAMPSLi/PVF/N, N-dimethyl-N-propyl-N-butylammonium dicyanamide (PAMPSLi/PVF/$N_{1134}$DCA) exhibited low viscosity ($N_{1134}$TCM:$N_{1134}$DCA 28.6cP, 28.7cP) and higher conductivity ($2.48{\times}10^{-3}Scm^{-1}$, $2.2{\times}10^{-3}Scm^{-1}$) than homopolymer system. The ionic conductivity PAMPSLi/PVF/1-ethyl-3-methyl imidazolium dicyanamide (PAMPSLi/PVF/emImDCA) exhibited $1.54{\times}10^{-3}Scm^{-1}$ and low viscosity (emImDCA: 28.09cP). High flexibility of imidazolium cation and dissociation of lithium cation from the co-polymer chains were affected by high conductivity and low viscosity.
The water-like ionic liquids have been widely used to enable the proton conduction in ionic liquid based membranes at high temperature and anhydrous PEFCs. In this study, we synthesized various kinds of composite membranes based on hydrocarbon polymers having good thermal and mechanical stabilities at high temperatures and ionic liquids. The composite membrane consisting of hydrocarbon polymer and ionic liquid was characterized by thermogravimetric analyzer (TGA) and impedance spectroscopy. Consequently the non-aqueous composite membranes of a variety of hydrocarbon polymer and ionic liquids have good conductivity and thermal stability at high temperature conditions.
Zinc oxide nanoparticles (ZnONPs) are widely used in a variety of products and cosmetic products including paper, paints, plastics and sunscreen. However, information on the safety of ZnONPs are not enough and many publications suggest possible toxic effects on environmental and human health. Furthermore, physico-chemical characteristics of nanoparticles makes it hard to test toxicity using the test guidelines of chemicals adopted by regulatory bodies. In this study, stability of ZnONPs was investigated using different types of isotonic solution, which is important in the toxicity study of intravenous route. Precipitation, aggregation, size, zeta potential and morphology of ZnONPs were evaluated with different times and concentrations. Precipitation of ZnONPs were observed in ionic isotonic solution including phosphate-buffered saline, Kreb's-Ringer solution, physiological salt solution and cell culture media of DMEM (Dulbecco's Modified Eagle's Medium) with 10% fetal bovine serum. On the other hand, they were stable without precipitation in non-ionic isotonic solution such as 5% glucose and 2% glycerol, respectively, which are biocompatible for intravenous injection. The average size of ZnONPs in 5% glucose and 2% glycerol was stably maintained, which is less than 30 nm and very similar as that in water dispersion of ZnONPs, provided by the manufacturer. The stability was maintained during the experimental period of 5 days and diluted state up to 15,000 ppm. These data suggest that 5% glucose and 2% glycerol solution can be used for the vehicles of ZnONPs in the toxicity study of intravenous injection route.
Proton conducting polymeric gels as the electrolytes of electrochemical capacitors have been prepared by two different methods: 1) swelling a polymethacrylate-based polymer matrix in aqueous solutions of inorganic and organic acids, and 2) polymerizing complexes of anhydrous acids and prepolymers with organic plasticizer. The FT-IR spectra strongly suggest that the carbonyl groups in the polymer matrix interact with protons from the doped acids. High ionic (proton) conductivity in the range of $6\times10^{-4}-4\times10^{-2}\;S\;cm^{-1}$ was obtained at room temperature for the aqueous gels. The non-aqueous polymer complexes showed rather low ionic conductivity, but it was about $10^{-3}\;S\;cm^{-1}\;at\;70^{\circ}C$ for the $H_3PO_4$ doped polymer electrolyte. The mechanisms of ion (proton) conduction in the polymeric systems are discussed.
Journal of Korean Society for Atmospheric Environment
/
v.2
no.1
/
pp.41-54
/
1986
Methods used for averaging PH's of rainwater and site representation have been studied, Statistical analysis was attempted regarding effects of ionic components on PH's utilizing 847 data altogether obtained in two years, 1984 and 1985. The outcome of the study may be assumarized as follows: 1. Methods for Averaging PH Volume weighted method is considered to be acceptable providing that precipitation is measured at the same time when the samples are taken. Without precipitation data a simple averaging method should be the next choice. 2. Site Representation A statistical method used for optimizing a monitoring newtork was applied using the data collected. Because of a limited number of data, no discernible conclusion can be reached suggesting that the method can serve as a good guide when the data base becomes more reliable. 3. A good correlation appears to exist betwen conductivities and ionic components in rainwater. It would, therefore, be possible to certain extend to estimate ionic concentrations from conductivity measurements by correlation equations. 4. The acidity of rainwater is effected by $SO_4^{2-}, NO_3^-, Cl^- and NH_4^+ with SO_4^{2-}$ being the most significant as demonstrated by standardized regression analysis.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.26
no.12
/
pp.87-92
/
2012
In this paper, EHD(electrohydrodynamics) characteristics of AC corona discharge for the various frequency was investigated. Ionic wind velocity is controlled by the frequency of applied ac high voltage, and maximum velocity of the ionic wind is obtained at 1.2kHz. Maximum velocity are 1.90 m/s by metal corona electrode and 2.72m/s by wet porous corona electrode, These attain 91~99% of the maximum velocity in the DC corona discharge by adjusting the frequency through the experiments. In this paper, wet porous corona electrode has high possibility of cooling methode because a AC corona discharge using wet porous corona electrode is able to eject more water droplets than DC corona discharge.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.