• Title/Summary/Keyword: ion selective resin

Search Result 42, Processing Time 0.022 seconds

Adsorption Property of Heavy Metal ion, $Cd^{2+}$-$Cl^{3+}$-$Pb^{2+}$+ in HCI Solution (HCl 용액에서의 중금속 이온, $Cd^{2+}$-$Cl^{3+}$-$Pb^{2+}$의 흡착 특성)

  • 박원우;이봉헌
    • Journal of Environmental Science International
    • /
    • v.5 no.6
    • /
    • pp.779-783
    • /
    • 1996
  • Cation exchange distribution coefficients of poly(dithiocarbamate) were presented for $Cd^{2+}$, $Cr^{3+}$, and $Pb^{2+}$ in HCI. The distribution coefficients were determined tv using the batch method. Based on these distribution data, the separation possibilities of the heavy metal ions were discussed. The distribution coefficients of three heavy metal ions on dithiocarbamate resin were decreased as HCI concentrations were increased. The selective separation of $Cr^{3+}$ and $Cd^{2+}$ was possible by using 0.1M HCl in dithiocarbamate resin and the reproducibility test showed that the average absorptivity of resin was 90% in the case of $Cd^{2+}$ ion by the column method.

  • PDF

Metal Ion Selectivity of Surface Templated Resins Carrying Phosphate Groups

  • Murata, Masaharu;Maeda, Mizuo;Takagi, Makoto
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.529-534
    • /
    • 1995
  • The metal ion selective resins were prepared by surface template polymerization using monooleyl phosphoric acid (1), oleyl methyl phosphoric acid (2) or oleyl ethyl phosphoric acid (3) as an amphiphilic host surfactant. The $Cu^{2+}$-imprinted resins prepared in the presence of $Cu^{2+}$ adsorbed $Cu^{2+}$ much more effectively than did their reference resins. On the other hand, the $Cu^{2+}$-imprinted resins showed much less binding ability to $Zn^{2+}$. The template-dependent selectivity should be ascribed to a favorable placement of the surface-anchored metallophilic groups for multidentate coordination to specific metal ion.

  • PDF

Selective Adsorption Properties of Nitrate ion in Sulfate and Nitrate Solution by Bead and Fibrous Hybrid Ion Exchange Bed (비드와 섬유 혼성이온교환 베드를 이용한 황산이온과 질산이온 혼합용액에서 질산이온의 선택 흡착 특성)

  • 황택성;박명규
    • Polymer(Korea)
    • /
    • v.27 no.1
    • /
    • pp.69-74
    • /
    • 2003
  • In this study, we have investigated the adsorption properties for nitrate ion in ground water using mixed resin type hybrid ion exchange (HIXF) and fiber type ion exchanger. Their swelling ratio (4.45 g/g) and ion exchange capacities (2.45 meq/g) were higer than the swelling ratio of IEC and IXF. Adsorption yield increased for nitrate $NO_3^-$ and sulfate $SO_4^{2-}$ ions were optimal at the concentration ratios of nitrate and sulfate below 1.0 and the adsorption yields were 100% and 20%, respectively. On the other hand it was shown that the degree of adsorpted for nitrate to pH 3, but it was little changed in the other pH range. We found that the selective adsorption capacity for nitrate was the optimal the mixing ratios of resin and fibrous ion exchanger of below 0.5.

Comparison of Selective Removal of Nitrate Ion in Constant Voltage and Constant Current Operation in Capacitive Deionization (축전식 탈염에서 정전압과 정전류 운전에 따른 질산 이온의 선택적 제거율 비교)

  • Choi, Jae-Hwan;Kim, Hyun-Ki
    • Korean Chemical Engineering Research
    • /
    • v.53 no.3
    • /
    • pp.269-275
    • /
    • 2015
  • The adsorption characteristics of ions were evaluated for the nitrate-selective carbon electrode (NSCE) in accordance with power supply methods. The NSCE was fabricated by coating the surface of a carbon electrode with anion-exchange resin powders with high selectivity for the nitrate ion. Capacitive deionization (CDI) experiments were performed on a mixed solution of nitrate and chloride ion in constant voltage (CV) and constant current (CC) modes. The number of total adsorbed ions in CV mode was 15% greater than that in CC mode. The mole fraction of adsorbed nitrate ion showed the maximum 58%, though the mole fraction was 26% in the mixed solution. This indicates that the fabricated NSCE is highly effective for the selective adsorption of nitrate ions. The mole fraction of adsorbed nitrate was nearly constant value of 55-58% during the adsorption period in CC mode. In the case of CV mode, however, the values increased from the initial 30% to 58% at the end of adsorption. We confirmed that the current supplied to cell is important factor to determine the selective removal of nitrate.

Selective Separation and Determination of Iron with Ion-Exchange Resins (이온교환수지에 의한 철의 선택적 분리 및 정량)

  • Yong Soon Chung;Dong Won Kim;Seung Ho Kim;Dai Woon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.45-54
    • /
    • 1987
  • Dowex 1-X8 resin ion exchanged with calcon carboxylic acid (CCA-Dowex 1-X8) and 2-methyl-8-hydroxyquinoline(MHQ) impregnated-Amberlite XAD-4 resin (MHQ-XAD-4) were examined for the separation and preconcentration of ferric ion from the various matrices. The stabilities of these resins were investigated, and their capacities on ferric ion were also measured. The effect of pH on the adsorption of ferric ion and matrix ions, such as Al(Ⅲ) and Ca(Ⅱ), was investigated to determine the optimun pH ranges. Separation and preconcentration of iron in aluminium foil and mineral water samples were studied by elution method with these resin columns. The recovered ions by 10ml of 2F nitric acid was determined by flame atomic spectrophotometry. SP-Sephadex C-25 column was used to separate ferrous and ferric ion in mineral water by stepwise elution with ferrozine and 1 % ascorbic acid-ferrozine solution. The concentrated and separated each ion could be determined spectrophotometrically at the analytical wavelenth of Fe(Ⅱ)-ferrozine complex (562nm).

  • PDF

Selective Nitrate Removal Performance Analysis of Ion Exchange Resin in Shipboard Waste Washwater by Air Pollution Prevention Facility (선박용 대기오염장치 폐세정수 내 질산염의 선택적 제거를 위한 이온교환수지 공정 성능 평가)

  • Kim, Bong-Chul;Yeo, In-Seol;Park, Chan-Gyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.399-404
    • /
    • 2021
  • From 1 January 2020, the limit for Sulphur in fuel oil used on board ships operating outside designated emission control areas will be reduced to 0.5 %. This regulation by international maritime organization (IMO) is able to significantly reduce the amount of Sulphur oxides (SOx) discharging from ships and should have environmental advantages and health for all over the world. To meet the regulation, in these days, wet scrubber system is being actively developed. However, this process leads to make washing wastewater. In this study, we evaluated ion exchange resin system in accordance with scrubber wastewater discharge regulation by IMO. Theoretical wastewater used as feed solution of lab scale water treatment systems. The results revealed that nitrate ion was removed selectively in spite of high TDS wash wastewater solution depending on ion exchange resin property. Moreover, it was possible to improve efficiency of the system by optimizing operating conditions.

A study on the removal of As, Sb, Bi from the copper sulfate solutions by Ion exchange resin containing Aminophosphosphonic acid as a functional group (황산동용액(黃酸銅溶液)에서 Aminophosphosphonic acid 관능기를 가진 이온교환수지에 의한 As, Sb, Bi 제거(除去)에 관한 연구(硏究))

  • Ahn, Jae-Woo;Seo, Jae-Seong
    • Resources Recycling
    • /
    • v.21 no.5
    • /
    • pp.50-57
    • /
    • 2012
  • A comparative study has been carried out on the removal of impurities such As, Sb, Bi from the copper sulfate solution by ion exchange resin containing aminophosphosphonic acid as functional group. The various parameters which affect the removal of impurities; such as the reaction temperature, the reaction time, the amount of ion-exchange resins, the concentration of sulfuric acid in electrolyte, were studied. The basic experimental results showed that about 88% of Sb & 94% of Bi can be adsorbed in these chelate resins and removed from the copper sulfate solutions but As was removed below 10% from the solutions. And the selective elution of Bi and Sb from the adsorbed ion exchange resin also can be achieved by $H_2SO_4$ or HCl solutions. The results also showed that 98.1% of Sb and 96.6% of Bi can be adsorbed from the copper sulfate solutions after 2 Bed-volume of continuous ion exchange column test.

Separation of Radiostrontium from Environmental Sample Using Strontim Selective Chromatographic Resin$(Sr.\;Spec^{TM})$ (스트론튬 선택적이온교환수지$(Sr.\;Spec^{TM})$를 이용한 환경시료중의 방사성 스트론튬의 분리)

  • Hong, Kwang-Hee;Lee, Chang-Woo;Choi, Yong-Ho;Lee, Myung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • Strontium selective chromatographic material $(Sr-Spec^{TM})$ was investigated for separation of radiostrontium from environmental soil and water sample. This chromatographic material has great capacity of binding of strontium ion in nitric acid media, and has selectivity to permit the separation of stontium from bulk amount of calcium. But the extraction of strontium was reduced by the other interfering ions such as K and Ba. So, in order to apply this material to the soil sample, prior removal treatment of K and Ba was needed. But the Sr-Spec material could provides simple and effective methods for the separation and removal of radiostrontium from liquid sample.

  • PDF

Separation and Recovery of Rare Earths by Ion Exchange Chromatography (이온교환 크로마토그래피에 의한 희토류 원소의 분리와 회수)

  • Cha, Ki Won;Park, Kwang Won;Hong, Sung Wook
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.11
    • /
    • pp.612-638
    • /
    • 1997
  • The methods of separation and recovery of rare earth elements in monazite sand have been studied by the ion exchange chromatography. Both of cation and anion exchange resin were used as ion exchange resins and the solutions of EDTA, DTPA, IMDA and Ln-EDTA were used as eluents. The H+, Zn2+, Fe3+, Al3+, Cu2+, and NH4+ forms of cation exchange resin were used as retaining ions. Ln-EDTA solution was loaded on the EDTA form of anion exchange resin and separated. The Ln-EDTA solution was also used as an eluent for a selective separation of one element from the rare earth mixture solution. The size effects of resin column, the elution mechanism for the various elution types and the separation of a large amount of rare earths were studied.

  • PDF

A Study on Electrodeionization for Purification of Primary Coolant of a Nuclear Power Plant (원자력 발전소의 일차 냉각수 정화를 위한 전기탈이온법의 기초연구)

  • Yeon, Kyeong-Ho;Moon, Seung-Hyeon;Jeong, Cheorl-Young;Seo, One-Sun;Chong, Sung-Tai
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.73-86
    • /
    • 1999
  • The ion-exchange method for the purification of primary coolant has been used broadly in PWR(pressurized water reactor)-type nuclear power plants due to its high decontamination efficiency, simple system, and easy operation. However, its non-selective removal of metal and non-radionuclides shortens its life, resulting in the generation of a large amount of waste ion-exchange resin. In this study, the feasibility of electrodeionization (EDI) was investigated for the purification of primary cooling water using synthetic solutions under various experimental conditions as an alternative method for the ion exchange. The results shows that as the feed flow-rate increased, the removal efficiency increased and the power consumption decreased. The removal rate was observed as a 1000 decontamination factor(DF) at a nearly constant level. For the synthetic solution of 3 ppm TDS (Total Dissolved Solid), the power consumption was 40.3 mWh/L at 2.0 L/min of feed flow rate. The higher removal rate of metal species and lower power consumption were obtained with greater resin volume per diluting compartment. However, the flow rate of the EDI process decreased with the elapsed time because of the hydrodynamic resistivity of resin itself and resin fouling by suspended solids. Thus, the ion-exchange resin was replaced by an ion-conducting spacer in order to overcome the drawback. The system equipped with the ion-conducting spacer resolved the problem of the decreasing flow rate but showed a lower efficiency in terms of the power consumption, the removal rate of metal species and current efficiency. In the repeated batch operation, it was found that the removal efficiency of metal species was stably maintained at DF 1000.

  • PDF