• 제목/요약/키워드: inverter type unit

검색결과 50건 처리시간 0.018초

상업용 냉장고의 상황 감지를 위한 인버터형 실외기 신호 분석 (Signal Analysis of Inverter-Type Outdoor Unit for Detecting Operation Changes of Commercial Refrigerator)

  • 임효준;이주경;황준현;이경창;이석
    • 한국정밀공학회지
    • /
    • 제33권6호
    • /
    • pp.517-523
    • /
    • 2016
  • Unlike household refrigerators, commercial refrigerators are composed of separate indoor and outdoor units. The outdoor unit of most commercial refrigerators is designed to run at a fixed speed, which results in low energy efficiency and loud fan noise. Moreover, it cannot respond flexibly to changing thermal load in the indoor unit. Inverter type outdoor units can address such problems through speed changes based on information obtained from the indoor unit. However, using two units from different manufacturers is often not a viable solution. If condition changes in the indoor unit can be detected without communication between the two units, it is possible to adjust the speed of the outdoor unit. This paper attempts to analyze the signal from the outdoor unit when the condition of the indoor unit changes by varying the thermal load.

인버터 타입 오일냉각기의 온도제어 특성에 관한 연구 (Characteristics of Temperature Control in the Inverter Type Oil Coolers)

  • 이상호;이찬홍;박천홍
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.233-236
    • /
    • 2003
  • In this Paper, the temperature control error and cooling characteristics of inverter typ coolers are evaluated to predict application validity of coolers under heating pattern and amount The temperature control error of coolers small in 15~70% range of the max. cooling ability. At less than 15% of max. cooling ability has the inverter type cooler a basic temperature control error $\pm0.5^{\circ}C$ and acts as on/off type coolers. The inverter type cooler is unsuitable for precision temperature control under the complex heating pattern. But PID control of cooler including the heating system is an alternative for the case.

  • PDF

휴리스틱 기법을 이용한 비통신 인버터형 냉장시스템의 성능개선 알고리즘 개발 (Heuristic Algorithm for Performance Improvement of Non-Communication Inverter Type Refrigerator)

  • 민선규;김형준;이주경;황준현;이석
    • 한국정밀공학회지
    • /
    • 제34권2호
    • /
    • pp.133-138
    • /
    • 2017
  • Inverter-Type refrigerators are known to consume less energy by varying the inverter frequency according to indoor temperatures and refrigerant pressure through indoor-outdoor communication. However, many commercial operators cannot afford to replace indoor units with ones capable of communication. In a non-communication configuration, indoor units are connected with an inverter-type outdoor unit without intercommunication abilities. The research goal is finding appropriate operating parameters to achieve energy efficiency. Thus, an operation algorithm with two modes is proposed, i.e., one to search the best operating parameters and one for normal operation with the best parameters. The experimental evaluation showed 11.27% reduction in energy consumption, indicating a good applicability of the algorithm.

고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구 (A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor)

  • 김종해;원재선
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

순시전류합성형 부하병렬 고주파 공진 인버터의 특성해석 (Characteristics Analysis of Instantaneous Current Resultant Type Load Parallel High Frequency Resonant Inverter)

  • 조규판;원재선;이봉섭;심광렬;배영호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.293-296
    • /
    • 2002
  • This paper describes the instantaneous current resultant type load parallel high frequency resonant inverter consisting of three unit half-bridge serial and parallel resonant inverter can be used as power source of induction heating. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, the principle of basic operating and the its characteristics are estimated by the parameters such as switching frequency($\mu$), load resistance(λ). Experimental results are presented to verify theoretical discussion. This proposed inverter will can be practically used as a power supply in various fields as induction heating application, DC-DC converter etc.

  • PDF

Fault Tolerant Operation of CHB Multilevel Inverters Based on the SVM Technique Using an Auxiliary Unit

  • Kumar, B. Hemanth;Lokhande, Makarand M.;Karasani, Raghavendra Reddy;Borghate, Vijay B.
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.56-69
    • /
    • 2018
  • In this paper, an improved Space Vector Modulation (SVM) based fault tolerant operation on a nine-level Cascaded H-Bridge (CHB) inverter with an additional backup circuit is proposed. Any type of fault in a power converter may result in a power interruption and productivity loss. Three different faults on H-bridge modules in all three phases based on the SVM approach are investigated with diagrams. Any fault in an inverter phase creates an unbalanced output voltage, which can lead to instability in the system. An additional auxiliary unit is connected in series to the three phase cascaded H-bridge circuit. With the help of this and the redundant switching states in SVM, the CHB inverter produces a balanced output with low harmonic distortion. This ensures high DC bus utilization under numerous fault conditions in three phases, which improves the system reliability. Simulation results are presented on three phase nine-level inverter with the automatic fault detection algorithm in the MATLAB/SIMULINK software tool, and experimental results are presented with DSP on five-level inverter to validate the practicality of the proposed SVM fault tolerance strategy on a CHB inverter with an auxiliary circuit.

인버터식 X선장치의 성능평가 시 비접속형 측정기의 유용성 (Usefulness of Non-Invasive Measurement Tool on Performance Evaluation of Inverter Type X-ray Unit)

  • 강세식;김창수;고성진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.123-127
    • /
    • 2008
  • 목 적: 임상에서 인버터식 X선장치의 사용이 보편화됨에 따라 이에 대한 보다 정확하고 간편한 성능평가 방법이 요구되고 있다. 따라서 최근 국내에 소개되어 사용되고 있는 X-Ray Multi-Function Test Device (model : Xi (unfors)-prestige)를 이용한 성능평가의 유용성을 확인하고자 한다. 방 법: 인버터식 X선장치의 성능 평가시 접속형 측정장비로 널리 활용되고 있는 Dynalyzer III를 이용한 성능평가를 기준으로 하여 비접속형 측정장비인 X-Ray Multi-Function Test Device (model: Xi (unfors)-prestige)의 성능평가를 비교 분석하여 그 유용성을 검토하였다. 결 과: 두 측정기에 대한 X선 출력선량은 큰 차이 없이 측정되었으며 촬영조건 등의 변화에 따라서 접속형인 Dynalyzer III가 약간 증가된 값으로 측정되었으며 출력의 재현성은 두 측정기 모두 성능평가 합격 기준 0.05 이하인 0.002 이하로, 직선성은 합격기준인 0.1 이하로 평가되었다. 촬영조건의 정확도에서는 관전압은 1.8과 2, 관전류는 2.01과 2.3, 촬영시간은 T > 0.01 sec에서 ${\pm}10%$ 이하로 나타났다. 모두 성능평가 기준의 허용범위에 있는 것으로 나타났다. 결 론: X-Ray Multi-Function Test Device (model: Xi (unfors)-prestige) 측정기를 이용한 인버터식 X선장치의 X선 출력의 재현성, 직선성과 촬영조건의 정확도에 대한 성능평가의 유용성을 확인하였다.

  • PDF

Half-Bridge 직렬 공진형 인버터를 단위인버터로 한 시분할방식 고주파 인버터의 특성해석에 관한 연구 (A Study on Characteristics Analysis of Time Sharing Type High Frequency Inverter Consisting of Three Unit Half-Bridge Serial Resonant Inverter)

  • 조규판;원재선;서철식;배영호;김동희;노채균
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.90-97
    • /
    • 2001
  • 본 논문은 고주파 유도가열용 전원에 사용되는 Half-Bridge 직렬 공진형 인버터를 단위인버터로 한 고주파 인버터 회로를 제시하였다. 제안한 인버터의 구동신호 제어기법으로는 아날로그와 디지털 통신에서 신호전송용으로 널리 사용되는 TDM(Time Division Multiplexing) 방식을 응용한 시분할 구동법을 사용하였다. 회로의 해석은 정규화 파라메타를 도입하여 범용성 있게 기술하였고, 인버터 특성은 스위칭 주파수와 제 파라메타에 따라 특성평가를 행하였다. 또한, 이론해석에서 얻은 특성값을 기초로 한 회로 설계 기법의 일 예도 제시하였다. 범용 시뮬레이션 툴인 Pspice를 통해 이론해석의 타당성을 검증하였으며, 향후 유도가열 응용, DC-DC 컨버터 등의 전원 시스템에 응용 가능성을 보여주고 있다.

  • PDF

표준 CMOS 게이트 산화막 안티퓨즈를 이용한 새로운 OTP 단위 비트와 ROM 설계 (Design of Novel OTP Unit Bit and ROM Using Standard CMOS Gate Oxide Antifuse)

  • 신창희;권오경
    • 대한전자공학회논문지SD
    • /
    • 제46권5호
    • /
    • pp.9-14
    • /
    • 2009
  • 표준 CMOS 공정을 이용한 CMOS 게이트 산화막 안티퓨즈의 새로운 OTP 단위 비트 구조를 제안하였다. 제안된 OTP 단위 비트는 NMOS 게이트 산화막 안티퓨즈를 포함한 3개의 트랜지스터와 인버터 타입 자체 센스 엠프를 포함하고 있다. 그럼에도 불구하고, 레이아웃 면적은 기존 구조와 비슷한 $22{\mu}m^2$이다. 또한, 제안된 OTT 단위 비트는 구조적 특징상 고전압 차단스위치 트랜지스터와 저항과 같은 고전압 차단 요소를 사용하지 않기 때문에, 프로그램 시간은 기존 구조보다 개선된 3.6msec이다. 그리고 제안된 OTP 단위 비트를 포함하는 OTP array는 센스 엠프가 단위 비트마다 집적되어 있기 때문에 기존 OTP array에서 사용된 센스 엠프와 바이어스 생성 회로가 필요 없다.

인버터형 에어컨 전원용 태양광시스템의 MPPT 동작 특성에 관한 연구 (The Study on the Operating Characteristic of MPPT for Photovoltaic System with Inverter Type Airconditionig System)

  • 유권종;차인수;임중열;김동휘
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.129-135
    • /
    • 1998
  • A photovoltaic system is an infinite and clean energy system. A photovoltaic system consists of a solar cell array, a converter, a inverter and a control unit. It is necessary that the Maximum Power Point Tracker(MPPT) is applied to the photovoltaic system because the output power of solar cell array is varied with irradiation, temperature and external effects. In this paper, the neural networks theory, one of the control methods, is applied to track the maximum power point of the photovoltaic system. The MPPT using neural networks theory is proposed to improve existing energy converter efficiency. Also the theory is applied to operation of inverter type airconditionig system.

  • PDF