• Title/Summary/Keyword: intraocular

Search Result 174, Processing Time 0.019 seconds

Analysis of Correlation by Myopic Refractive Errors and Intraocular Pressure (근시성 굴절이상과 안압의 상관관계 분석)

  • Kim, Bo-Yun;Lee, Eun-Hee;Jung, Mi-A
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.317-321
    • /
    • 2020
  • This study researched the correlation between myopic refractive errors and intraocular pressure. The study population comprised 39 adults(17 of males, 22 of females). We measured the intraocular pressure using a Non-Contact Tonometer(NCT) and the correlation between myopic refractive errors was analyzed by dividing into three groups: mild, moderate, high myopia. The gender of subjects showed no statistically difference between the intraocular pressure and refractive errors, but as the refractive errors increased, the intraocular pressure incereased, which showed a statistically significant difference. In addition, the higher intraocular pressure in moderate and high myopia than mild myopia can cause glaucoma, that can develop at a young age. it is need to sufficient recognition and understanding correlation between intraocular pressure and myopic refractive errors in the middle-aged high myopia.

A Case of Bronchioloalveolar Carcinoma Presenting with Initial Symptom of Visual Disturbance due to Intraocular Metastasis (시력 저하를 주소로 내원한 세기관지폐포암 1예)

  • Park, Sun Young;Oh, Hyung Jung;Moon, Jin Wook;Kang, Shin Myung;Hahn, Chang Hoon;Park, Moo Suk;Kim, Young Sam;Chang, Joon;Kim, Sung Kyu;Cho, Sang Ho;Kim, Se Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.1
    • /
    • pp.93-96
    • /
    • 2005
  • Intraocular tumors are uncommon and an intraocular metastatic carcinoma is extremely rare. An intraocular metastasis in adults most often originates from the breast or the lung. An intraocular lesion may be the first presentation of cancer and a search should be made to locate the primary tumor. To our knowledge, an intraocular metastasis of a bronchioloaveolar carcinoma has not reported in Korea. We report a case of a bronchioloalveolar carcinoma presenting with the initial symptom of a unilateral visual disturbance due to an intraocular metastasis.

Intraocular Lymphoma in a Dog (개의 Intraocular Lymphoma)

  • 우흥명
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.429-433
    • /
    • 2001
  • Lymphoma is one of the most common malignant neoplasms of the dog. Little has been published on intraocular lymphoma in dogs. This report presents a 8-year-old neutered male mixed dog with a previous history on inflammatory debris on the anterior and posterior lens capsules, vitreal hemorrhage, generalized peri-pheral lymphadenopathy and a palpable mid-abodominal mass. History, clinical signs, radiography, cytology, histopathology and chemotherapeutic response confirmed multicentric lymphoma with secondary ocular infla-mmation. Intraocular lymphoma, the most common secondary neoplasm of the canine eye, may be the present-ing evidence of systemic disease. This report describes a dog that presented with ocular manifestations of multicentric lymphoma.

  • PDF

A Study of Optical Properties of Intraocular Lenses and of Measurement of the Index of Reflection for an Unknown Liquid

  • Joo, Won Don;Jung, Mee Suk
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.236-242
    • /
    • 2012
  • In general, such methods as interferometers or wavefront sensors are commonly used for testing of an optical system and optical components. In these cases, the surrounding environments are unlikely to affect the measurements. On the other hand, intraocular lenses of hydrophilic materials with special properties experience a certain difficulty in testing the optical properties. An intraocular lens is dried in the air, which causes deformation and changes the optical characteristics such as index of refraction and thickness. Thus, it is hard to measure the optical characteristics of an intraocular lens by using common methods. In this study, a special structure is used for measuring of the transmission wavefront aberration and effective focal length of an intraocular lens of hydrophilic materials by using a Shark-Hartmann sensor among the various measuring methods. As an application of this measuring method, this study shows a simple method to measure the index of refraction of unknown liquids with a plano-convex lens with a well known index of refraction. Also, this method is used to measure the optical properties of a plano-convex such as index of refraction and curvature by using a liquid with a well known index of refraction.

Effects of Intravitreal Centamicin Injection on the Clinically Normal Canine Eye (개에서 초자체내 겐타마이신 주사의 영향)

  • 강선미;이충호;김완희;우흥명;권오경
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.333-336
    • /
    • 2002
  • This experiment was carried out to investigate the optimal dose of intravitreal gentamicin that decreases intraocular pressure effectively and minimizes complications in dog. After inhalation anesthesia, gentamicin was injected intravitreally into the left eyes at doses of 10, 15 and 20 mg with 1 mg dexamethasone, respectively. Sterilized isotonic saline and dexamethasone mixture into the right eyes for control. Six dogs were used in each group. Intraocular pressures were measured using applanation tonometer(Mentore, Tono-Pen) until 5 months after injection of gentamicin. Ocular examinations were performed using direct ophthalmoscopy. The ocular volumes of both eyes were measured. Intraocular pressures of eyes injected with 10. 15 and 20 mg of gentamicin were decreased significantly compared with control eyes. Severe corneal opacity and neovascularization occurred in 20 mg treated group. Intraocular hemorrhage was observed in 3 dogs of 20 mg treated group. Ocular volume was significantly decreased(p <0.05) in 20 mg treated group, compared with 10 and 15 mg treated group. It is considered that intravitreal gentamicin injection at dose of 10 mg or 15 mg decrease intraocular pressure effectively and minimize complications such as corneal opacity, hyphema and phthisis bulbus.

Effect of Tourmaline-added Eyeglass Frames on Normalization of Intraocular Pressure (토르말린이 첨가된 안경테가 안압 정상화에 미치는 영향)

  • Park, Sang-Chul;Jeong, Hye-Ri;Kwon, Jong-Moon;Lee, Gyu-Bin
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.461-468
    • /
    • 2018
  • Purpose : Tourmaline, a natural ore material, was applied to the entire eyeglasses to observe changes in intraocular pressure (IOP), one of the factors related to human ocular metabolism. Methods : After making eyeglass frames by mixing TR-90, which is the main material of eyeglass frames and 7wt% of tourmaline, The changes of intraocular pressure before and after wearing of tourmaline spectacle frames were divided into low, middle and high groups according to the intraocular pressure in 90 normal subjects (46 men and 44 women) in their 20s. Results : Total intraocular pressure was a significantly decreased to -4.14% (p<0.000) in the right eye after wearing tourmaline frames, and significantly decreased to -6.39 % (p<0.000) and -4.64 % (p<0.017) in the High and Middle groups, respectively. Total intraocular pressure was a significantly decreased to -2.74 % (p<0.004) in the left eye, and -4.58 % (p<0.000) in the High group only showed statically significant value. Conclusion : In this study, the spectacle frame containing 7wt% tourmaline was used and it was confirmed that the intraocular pressure was significantly decreased after wearing the spectacle frame, and it became close to the average value of the normal intraocular pressure range. The results of this study showed that tourmaline, which has the effect of promoting the metabolism and blood circulation of the body, has an effect on the normalization of the intraocular pressure by attaching it to the spectacle frame.

Development of Hydrogel for Decrease Protein Adsorption and Application to Intraocular Lens (단백질흡착 감소용 하이드로겔의 개발 및 인공수정체로의 적용)

  • Ko, Na Young;Lee, Hyun Mee
    • Journal of the Korean Chemical Society
    • /
    • v.62 no.1
    • /
    • pp.30-35
    • /
    • 2018
  • The purpose of this study was to decrease the protein adsorption and improve the function of the hydrophobic acrylic Intraocular lens(IOL). Hydrophobic acrylic intraocular lenses were prepared by using ethyleneglycol phenyletheracrylate (EGPEA), styrene and 2-hydroxyethyl methacrylate (HEMA). Polyvinyl pyrrolidone (PVP) and 2-methacryloyloxyethyl phosphorylcholine (MPC) were used as additives. Water contents, wettability, light transmittance and protein adsorption amount were measured to evaluate the physical properties of the intraocular lens. The water content and wettability of all samples containing additives were increased and the amount of protein adsorption decreased. In particular, samples containing MPC showed a further decrease in protein adsorption. The hydrophobic acrylic intraocular lens with PVP and MPC was found to improve the function of the intraocular lens by reducing the protein adsorption while having basic physical properties.

A Case Report of Intraocular Metastasis Treated with Radiotherapy (방사선치료를 시행한 전이성 안구암 1예)

  • Kim, Ok-Bae;Byun, Sang-Jun;Kim, Kwang-Soo;Lee, Ho-Jun;Kim, Jin-Hee
    • Radiation Oncology Journal
    • /
    • v.27 no.3
    • /
    • pp.169-172
    • /
    • 2009
  • Intraocular metastasis is the most common malignancy of the eye. The frequency of intraocular metastasis in all the patients dying of cancer is about 12% and ocular metastases will be detected more frequently in the future because the patients with malignant tumor are now living longer. Intraocular metastasis can cause a serious clinical problem such as blindness. The early recognition and treatment of intraocular metastasis are very important clinical oncologic issues to maintain vision and to maximize the quality of life. However, significance of intraocular metastasis is still under-evaluated for practicing oncologists. External beam radiotherapy is a safe, effective palliative treatment in terms of preserving both the vision and the eye globe.

Clinical and Pathological Characteristics of Intraocular Cysticercosis

  • Li, Juan-Juan;Zhang, Li-Wei;Li, Hua;Hu, Zhu-Lin
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.2
    • /
    • pp.223-229
    • /
    • 2013
  • This study aimed to explore the clinical, radiological, and pathological characteristics of intraocular cysticercosis due to Taenia solium metacestode infection. Total 8 patients diagnosed with intraocular cysticercosis at the Red Cross Hospital of Yunnan Province, China were examined retrospectively. Patients with clear dioptic media had undergone fundus chromophotography. All patients underwent B ultrasonography of the ocular region (CT) successive scanning of the orbit and cerebral tissues. Parasites were extracted surgically and then examined pathologically. The fundus chromophotography showed a white and condensing scolex package in the vesicle. The B ultrasonic examination showed a vesicle-like echogenic mass in the vitreous chamber, in which the high-level echo spot was the cysticercus scolex. The pathological examinations showed that the vesicle wall exhibited hyaline degeneration, inflammatory cell infiltration, neuroglial fiber, and glial cell proliferation layers from the inside to the outside. The scolex is round and is composed of the outer tissue (the body wall) and the inner furrow tissue; these tissues migrated together. Primordially differentiated sucking discs were found in one case, but no hooklets were found. The inner scolex tissue was folded like a paper flower. The severity of intraocular disease is closely correlated with the pathophysiological processes of the cysticercus worm. Pathological examination of the intraocular lesions can help to evaluate the course of the disease as well as to provide a scientific basis for effective antiparasitic medication.

Quantitative Assessment of Orbital Volume and Intraocular Pressure after Two-Wall Decompression in Thyroid Ophthalmopathy

  • Park, Sang Min;Nam, Su Bong;Lee, Jae Woo;Song, Kyeong Ho;Choi, Soo Jong;Bae, Yong Chan
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.2
    • /
    • pp.53-57
    • /
    • 2015
  • Background: Surgical outcomes after orbital wall decompression have focused on the degree of exophthalmos and intraocular pressure. The aim of this research was to evaluate intraorbital volume using computed tomography (CT) images following two-wall decompression using a combined subcilliary and endoscopic approaches. Methods: A retrospective review was performed for all patients who had undergone the two-wall decompression method. The pre/postoperative CT images were used to evaluate changes in intraocular volume. Intraocular pressure was evaluated using applanation tonometry. Surgical details are discussed within the body of text. Results: Two-wall decompression thru the medial wall and floor was associated with an average intraorbital volume change of $7.3cm^3$, with maximal accommodation up to $13cm^3$. Changes in intraocular pressures were not statistically significant. Conclusion: Two-wall decompression was effective in accommodation of up to $13cm^3$ of soft tissue herniation. There was no statistically significant association between changes in volume to pressure.