Effect of Reducing Scattering Radiation Exposure of Medical Staffs When Additional Shielding is Used in Interventional Radiology (중재적 방사선시술에서 부가 차폐체 사용 시 종사자의 산란선 피폭 감소효과)

  • Kim, Min-Jun;Baek, Kang-Nam;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.629-633
    • /
    • 2021
  • This article is designed to look into the radiation exposure dose to each body part and the shielding effect for workers using an additional shielding to reduce their radiation exposured by scattering radiation which is generated in a space between the operating table and lead curtain during interventional radiology(IR) procedures. After placing a human phantom on the table of SIEMENS' angiography machine, the following measurements were taken, depending on the presence of an additional shield of lead equivalent of 0.25 mmPb, manufactured for this purpose: dose to gonad, dose to an area where the personal dosimeter is placed, and dose to an area of eye lens is located. An ion chamber(chamber volume 1,800 cc) was utilized to measure scattering radiation. The two imaging tests were carried out as follows: fluoroscopy of the abdomen (66 kV, 100 mA, 60 seconds) and of the head (70 kV, 65 mA, 60 seconds); and digital subtraction angiography(DSA) of the abdomen (67 kV, 264 mA, 20 seconds) and of the head (79 kV, 300 mA, 20 seconds). In all the experiments, the shielding efficiency of the gonad position was the largest at 59.8%. In case an additional shielding was used as protection against scattering radiation that came through the operating table and the lead curtain during an IR, the radiation shielding efficiency was estimated to be up to 59.8%, leading to a conclusion that its presence may effectively reduce the radiation exposure dose of medical staffs.

Endovascular Treatment of Congenital Portosystemic Shunt: A Single-Center Prospective Study

  • Ponce-Dorrego, Maria-Dolores;Hernandez-Cabrero, Teresa;Garzon-Moll, Gonzalo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.2
    • /
    • pp.147-162
    • /
    • 2022
  • Purpose: To design a prospective study on endovascular closure of congenital portosystemic shunts. The primary endpoint was to assess the safety of endovascular closure. The secondary endpoint was to evaluate the clinical, analytical and imaging outcomes of treatment. Methods: Fifteen patients (age range: 2 days to 21 years; 10 male) were referred to our center due to congenital portosystemic shunts. The following data were collected prior to treatment: age, sex, medical history, clinical and analytical data, urine trimethylaminuria, abdominal-US, and body-CT. The following data were collected at the time of intervention: anatomical and hemodynamic characteristics of the shunts, device used, and closure success. The following data were collected at various post-intervention time points: during hospital stay (to confirm shunt closure and detect complications) and at one year after (for clinical, analytical, and imaging purposes). Results: The treatment was successful in 12 participants, migration of the device was observed in two, while acute splanchnic thrombosis was observed in one. Off-label devices were used in attempting to close the side-to-side shunts, and success was achieved using Amplatzer™ Ductus-Occluder and Amplatzer™ Muscular-Vascular-Septal-Defect-Occluder. The main changes were: increased prothrombin activity (p=0.043); decreased AST, ALT, GGT, and bilirubin (p=0.007, p=0.056, p=0.036, p=0.013); thrombocytopenia resolution (p=0.131); expansion of portal veins (p=0.005); normalization of Doppler portal flow (100%); regression of liver nodules (p=0.001); ammonia normalization (p=0.003); and disappearance of trimethylaminuria (p=0.285). Conclusion: Endovascular closure is effective. Our results support the indication of endovascular closure for side-to-side shunts and for cases of congenital absence of portal vein.

Percutaneous Transhepatic Removal of Migrated Biliary Stent from a Chronic Biloma Cavity (만성 담즙종 공동 내로 이동한 담도 스텐트의 경피경간적 제거)

  • Hyoung Nam Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.442-447
    • /
    • 2020
  • Iatrogenic foreign bodies are a challenging complication to both the interventional radiologist and patient, resulting in impaired quality of life and substantial financial cost. The case report describes a successful percutaneous transhepatic removal of an intra-abdominal foreign body. A 72-year-old man underwent surgery for placement of a retrievable covered stent for refractory bile leakage after left hemihepatectomy. Three days after placement, stent folding and migration into a chronic biloma cavity occurred via the bile leakage site. By using a balloon catheter technique, the folded stent could be straightened and repositioned into the bile duct to minimize stent-strut injury during retrieval. The interventional approach could be a valid treatment option for intra-abdominal foreign bodies, as well as intravascular foreign bodies. A thorough understanding of devices and techniques can provide the interventional radiologist with valuable information regarding procedural planning and the management of iatrogenic foreign bodies.

Fast Real-Time Cardiac MRI: a Review of Current Techniques and Future Directions

  • Wang, Xiaoqing;Uecker, Martin;Feng, Li
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.252-265
    • /
    • 2021
  • Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard non-invasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for real-time cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.

Lymphatic Intervention, the Frontline of Modern Lymphatic Medicine: Part I. History, Anatomy, Physiology, and Diagnostic Imaging of the Lymphatic System

  • Saebeom Hur;Jinoo Kim;Lakshmi Ratnam;Maxim Itkin
    • Korean Journal of Radiology
    • /
    • v.24 no.2
    • /
    • pp.95-108
    • /
    • 2023
  • Recent advances in lymphatic imaging have provided novel insights into the lymphatic system. Interventional radiology has played a significant role in the development of lymphatic imaging techniques and modalities. Radiologists should be familiar with the basic physiology and anatomy of the lymphatic system to understand the imaging features of lymphatic disorders, which reflect their pathophysiology. This study comprehensively reviews the physiological and anatomical aspects of the human lymphatic system as well as the latest lymphatic imaging techniques.

Usefulness of a Functional Tracheobronchial Phantom for Interventional Procedure (중재 시술용 기능성 기관-기관지 팬텀의 유용성)

  • Kim, Tae-Hyung;Lim, Cheong-Hwan;Kim, Jeong-Koo;Kim, Myeong-Soo;Choi, Won-Chan;Lim, Jin-Oh;Lee, Kwang-Jong;Park, In-Ae;Kim, Mi-Ok;Jung, Eun-Mi;Shin, Ryung-Mi;Jung, Seung-Ki;Youn, Sun-Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.27-32
    • /
    • 2003
  • To evaluate usefulness of a functional tracheobronchial phantom for interventional procedure. The functional phantom was made as a actual size with human normal anatomy used silicone and a paper clay mold. A tracheobronchial-shape clay mold was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed. We measured film density and tracheobronchial angle at the human, animal and phantom, respectively. The film density of trachea part were 0.76(${\pm}0.011$) in human, 0.97(${\pm}0.015$) in animal, 0.45(${\pm}0.016$) in phantom. The tracheobronchial bifurcation part measured 0.51(${\pm}0.006$) in human, 0.65(${\pm}0.005$) in animal, 0.65(${\pm}0.008$) in phantom. The right bronchus part measured 0.14(${\pm}0.008$) in human, 0.59(${\pm}0.014$) in animal and 0.04(${\pm}0.007$) in phantom. The left bronchus were 0.54(${\pm}0.004$) in human, 0.54(${\pm}0.008$) in animal and 0.08(${\pm}0.008$) in phantom. At the stent part were 0.54(${\pm}0.004$) in human, 0.59(${\pm}0.011$) in animal and 0.04(${\pm}0.007$) in phantom, respectively. The tracheobronchial angle of the left bronchus site were $42.6({\pm}2.07)^{\circ}$ in human, $43.4({\pm}2.40)^{\circ}$ in animal and $35({\pm}2.00)^{\circ}$ in phantom, respectively. The right bronchus site were $32.8({\pm}2.77)^{\circ}$ in human, $34.6({\pm}1.94)^{\circ}$ in animal and $50.2({\pm}1.30)^{\circ}$ in phantom, respectively. The phantom was useful for in-vitro testing of tracheobronchial interventional procedure, since it was easy to reproduce.

  • PDF

Endovascular Closure Resolves Trimethylaminuria Caused by Congenital Portosystemic Shunts

  • Ponce-Dorrego, Mar?a Dolores;Garzon-Moll, Gonzalo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.6
    • /
    • pp.588-593
    • /
    • 2019
  • This study aimed to report three new cases of an association between two rare conditions, congenital portosystemic shunts (CPSS) and trimethylaminuria (TMAU), and the efficacy of endovascular closure of the CPSS for resolving TMAU. Between November 2014 and April 2017, 15 patients with CPSS were enrolled in this prospective study to assess the efficacy of percutaneous endovascular shunt closure. Three patients presented with clinical symptoms of TMAU that were confirmed by urine analysis of trimethylamine (TMA) and TMA n-oxide. One year after endovascular closure of the congenital portosystemic shunt, the same parameters were evaluated were obtained and the values were compared to the pretreatment values. The results indicated the disappearance of clinical symptoms of TMAU and normalization of the urine test parameters in two patients and no changes in one patient, who developed new portosystemic communications.

Development and evaluation of modified lead gloves to reduce hand radiation dose during interventional radiological procedures

  • Hyun-Jun Park;Byungdu Jo;Seung-Jae Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2781-2789
    • /
    • 2024
  • We developed lead gloves that minimize radiation dose to the operator's hands during interventional radiological procedures and that do not impede the operator's surgical capabilities. Existing lead gloves can protect the operator's hands by shielding radiation, but use of such gloves may impair preception sensitivity, resulting in a reduction in the operator's surgical ability. Accordingly, in this study, we developed modified lead gloves that can reduce radiation dose while maintaining operator sensitivity during procedures by modifying the operator's main surgical finger area in existing lead gloves. To evaluate the performance of developed modified lead gloves, radiation was applied in surgical conditions without gloves and with surgical gloves, lead gloves, and modified lead gloves. The radiation dose was evaluated for each condition. When the modified lead gloves were worn, the degree of shielding was similar to when conventional lead gloves were worn. Based on these results, if the operator wears modified lead gloves during interventional radiological procedures, they will protect the hands from radiation while maintaining physical sensitivity in the hands.

MR Imaging-Histopathologic Correlation of Radiofrequency Thermal Ablation Lesion in a Rabbit Liver Model: Observation during Acute and Chronic Stages

  • Jong Deok Lee;Jeong Min Lee;Sang Won Kim;Chong Soo Kim;Woo Sung Mun
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.151-158
    • /
    • 2001
  • Objective: To determine the ability of MR imaging to detect the pathological changes occurring in radiofrequency (RF) thermal lesions and to assess its accuracy in revealing the extent of tissue necrosis. Materials and Methods: Using an RF electrode, thermal lesions were created in the livers of 18 rabbits. The procedure involved three phases. In the acute phase, six animals were killed the day after performing thermal ablation with RF energy, and two on day 3. In the subacute and chronic phases, eight rabbits underwent percutaneous hepatic RF ablation. After performing MR imaging, two animals were sacrificed at 1, 2, 4, and 7 weeks after the procedure, and MRpathologic correlation was performed. Results: In the acute phase, the thermal ablation lesions appeared at gross examination as well-circumscribed, necrotic areas, representing early change in the coagulative necrosis seen at microscopic examination. They were hypointense on T2-weighted images, and hyperintense on T1-weighted images. Gadolinium-enhanced MR imaging showed that a thin hyperemic rim surrounded the central coagulative necrosis. In the subacute phase, ablated lesions also showed extensive coagulative necrosis and marked inflammation at microscopic examination. Beyond two weeks, the lesions showed gradual resorption of the necrotic area, with a peripheral fibrovascular rim. The size of lesions measured by MR imaging correlated well with the findings at gross pathologic examination. Conclusion: MR imaging effectively demonstrates the histopathological tissue change occurring after thermal ablation, and accurately determines the extent of the target area.

  • PDF

Successful Interventional Treatment of a Huge Pseudoaneurysm of the Popliteal Artery Caused by a Percutaneous Balloon Angioplasty Complication: A Case Report (경피적 풍선성형술의 합병증으로 발생한 슬와동맥 거대 가성동맥류의 성공적인 인터벤션 치료: 증례 보고)

  • Hyunmin Kim;Seung Yeon Noh;Se Hwan Kwon;Hyun-Min Ko;Hyung Joon Ahn;Joo Hyeong Oh
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1185-1190
    • /
    • 2023
  • Pseudoaneurysms are among the most serious complications of percutaneous balloon angioplasty. Although pseudoaneurysm rupture rarely happens, when it does, the result can be fatal; thus, early detection and management are crucial. In this report, we disclose the case of a 34-year-old male with end-stage renal disease who presented with a huge symptomatic pseudoaneurysm of the left popliteal artery, following percutaneous balloon angioplasty three months prior. The pseudoaneurysm was successfully excluded using interventional treatment. The patient recovered well, and the follow-up was uneventful, with excellent patency of the covered stent.