• Title/Summary/Keyword: interval system

Search Result 2,378, Processing Time 0.031 seconds

Determination of the Optimal Aggregation Interval Size of Individual Vehicle Travel Times Collected by DSRC in Interrupted Traffic Flow Section of National Highway (국도 단속류 구간에서 DSRC를 활용하여 수집한 개별차량 통행시간의 최적 수집 간격 결정 연구)

  • PARK, Hyunsuk;KIM, Youngchan
    • Journal of Korean Society of Transportation
    • /
    • v.35 no.1
    • /
    • pp.63-78
    • /
    • 2017
  • The purpose of this study is to determine the optimal aggregation interval to increase the reliability when estimating representative value of individual vehicle travel time collected by DSRC equipment in interrupted traffic flow section in National Highway. For this, we use the bimodal asymmetric distribution data, which is the distribution of the most representative individual vehicle travel time collected in the interrupted traffic flow section, and estimate the MSE(Mean Square Error) according to the variation of the aggregation interval of individual vehicle travel time, and determine the optimal aggregation interval. The estimation equation for the MSE estimation utilizes the maximum estimation error equation of t-distribution that can be used in asymmetric distribution. For the analysis of optimal aggregation interval size, the aggregation interval size of individual vehicle travel time was only 3 minutes or more apart from the aggregation interval size of 1-2 minutes in which the collection of data was normally lost due to the signal stop in the interrupted traffic flow section. The aggregation interval that causes the missing part in the data collection causes another error in the missing data correction process and is excluded. As a result, the optimal aggregation interval for the minimum MSE was 3~5 minutes. Considering both the efficiency of the system operation and the improvement of the reliability of calculation of the travel time, it is effective to operate the basic aggregation interval as 5 minutes as usual and to reduce the aggregation interval to 3 minutes in case of congestion.

Intelligent Rain Sensing and Fuzzy Wiper Control Algorithm for Vision-based Smart Windshield Wiper System

  • Lee, Kyung-Chang;Kim, Man-Ho;Lee, Suk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1694-1699
    • /
    • 2003
  • A windshield wiper system plays a key part in assuring the driver's safety during the rainfall. However, because the quantity of rain and snow vary irregularly according to time and the velocity of the automobile, a driver changes wiper speed and interval from time to time to secure enough visual field in the traditional windshield wiper system. Because a manual operation of windshield wiper distracts driver's sensitivity and causes inadvertent driving, this is becoming a direct cause of traffic accidents. Therefore, this paper presents the basic architecture of a vision-based smart windshield wiper system and a rain sensing algorithm that regulates speed and interval of the windshield wiper automatically according to the quantity of rain or snow. This paper also introduces a fuzzy wiper control algorithm based on human's expertise, and evaluates the performance of the suggested algorithm in an experimental simulator.

  • PDF

A Comparative Analysis of Failure Rate, Effective Failure Rate and Equivalent Failure Rate of A System Composed of Identical Parallel Units (병렬구조 시스템의 고장률, 유효(有效) 고장률과 대등(對等) 고장률의 비교분석)

  • Cho, Kyung-Hwan
    • Journal of Applied Reliability
    • /
    • v.15 no.4
    • /
    • pp.256-261
    • /
    • 2015
  • The aim of this paper is to present some issues to be discussed in relation to failure rate of a system that has identical parallel units. It is assumed that Time-to-Failure of each unit has the same exponential distribution and all units are repairable with a periodic maintenance of time interval T. Effective failure rate is widely recommended for nonrepairable systems as the reciprocal of MTTF but it should not be applied for repairable systems if delayed maintenance is used. And equivalent failure rate of an imaginary system is taken into consideration, the reliability value of which is the same as that of the redundant system when time interval T is given. With a numerical example, failure rate, effective failure rate, and equivalent failure rate of the redundant system are analyzed comparatively.

A Direct Injection-mixing Total-flow-control Boom Sprayer System (주입식 총유량 자동제어방식 분관 방제기의 개발)

  • 구영모
    • Journal of Biosystems Engineering
    • /
    • v.21 no.2
    • /
    • pp.155-166
    • /
    • 1996
  • A direct injection sprayer was designed using the concepts of injection mixing and total flow control, flowrate-based system compensating for the variation of forwarding speed. A metered rate, proportionally to the actual diluent flow rate, of a tracer chemical was injected directly into the diluent stream. The injection of chemical may improve the precision and safety of chemical application process. The control system was evaluated for the variables of the control interval, tolerances and sensitivities of flow regulation valve and injection pump. Performance of the system was assessed as that the response time of flow rate, response time of injection rate, absolute steady state error, and the coefficient of variance(C.V.) of concentration were 8.5 and -0.53 seconds, 0.067 lpm(0.8%) and 3.15%, respectively, at optimal parameters of control interval of 1.0 sec, fast sensitivity of flow regulation valve, medium sensitivity of injection pump and medium tolerance of flow rate. Performance of the system can be improved by increasing the sensitivity of flow regulating valve and employing a high resolution velocimeter, such as Doppler radar.

  • PDF

Study of Discharge in Point-Plane Air Interval Using Fuzzy Logic

  • Bourek, Yacine;Mokhnache, Leila;Nait Said, Nacereddine;Kattan, Rafik
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.410-417
    • /
    • 2009
  • The objective of this paper is to study the discharge phenomenon for a point-plane air interval using an original fuzzy logic system. Firstly, a physical model based on streamer theory with consideration of the space charge fields due to electrons and positive ions is proposed. To test this model we have calculated the breakdown threshold voltage for a point-plane air interval. The same model is used to determine the discharge steps for different configurations as an inference data base. Secondly, using results obtained by the numerical simulation of the previous model, we have introduced the fuzzy logic technique to predict the breakdown threshold voltage of the same configurations used in the numerical model and make estimation on the insulating state of the air interval. From the comparison of obtained results, we can conclude that they are in accordance with the experimental ones obtained for breakdown discharges in different point-plane air gaps collected from the literature. The proposed study using fuzzy logic technique shows a good performance in the analysis of different discharge steps of the air interval.

Interpolation Technique to Improve the Accuracy of RR-interval in Portable ECG Device (휴대형 심전계 장치의 RR 간격의 정확도 개선을 위한 보간법 개발)

  • Lee, Eun-Mi;Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.316-320
    • /
    • 2010
  • HRV(Heart rate variability) analysis parameter is widely used as an index to evaluate the autonomic nervous system and cardiac function. For reliable HRV analysis, we need to acquire the accurate ECG signals. Most of commercially available portable ECG devices have low sampling rate because of low power consumption and small size issues, which make it difficult to measure RR-interval accurately. This study is to improve the accuracy of RR-interval by developing R-wave interpolation technique, based on the morphological characteristics of the QRS complex. When the developed method was applied to ECG obtained at 200 Hz and the results were compared with 1000 Hz reference device, the error range decreased by 1.33 times in sitting and by 2.38 times in cycling exercise. Therefore, the proposed interpolation technique is thought to be useful to improve the accuracy of R-R interval in the portable ECG device with low sampling rate.

Implementation and Evaluation of Time Interval Partitioning Algorithm in Temporal Databases (시간 데이타베이스에서 시간 간격 분할 알고리즘의 구현 및 평가)

  • Lee, Kwang-Kyu;Shin, Ye-Ho;Ryu, Keun-Ho;Kim, Hong-Gi
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • Join operation exert a great effect on the performance of system in temporal database as in the relational database. Especially, as for the temporal join, the optimization of interval partition decides the performance of query processing. In this paper, to improve the efficiency of parallel join query in temporal database. I proposed Minimum Interval Partition(MIP) scheme that time interval partitioning. The validity of this MIP algorithm that decides minimum breakpoint of the partition is proved by example scenario and I confirmed improved efficiency as compared with existing partition algorithm.

An OFDM Receiver Scheme for Multipath Environment with Delay Profile over the Guard Interval (가드인터벌을 초월하는 지연프로필의 멀티패스채널에 적합한 OFDM수신시스템)

  • 주창복
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.4
    • /
    • pp.66-72
    • /
    • 2003
  • In the present paper some fundamentals about exceeding the guard interval of an OFDM system is going to discuss and will introduce method to cancel a ISI and ICI effects. In this paper, the performance characteristics of robust OFDM receiving system algorithm that is composed of a channel estimator using recursive least square(RLS) algorithm in time domain and of a ISI and ICI replica and subtracter using the channel coefficients are presented. By computer simulation method, the effect of suppression of ISI and ICI is demonstrated and compared the BER performance with a conventional 1-tap equalized system. Especially the presented scheme improves the BER performance at low SNRs more or so compared with the conventional one-tap equalized receiving configuration.

  • PDF

Effect of Individual, Group or ESF Housing in Pregnancy and Individual or Group Housing in Lactation on the Performance of Sows and Their Piglets

  • Weng, R.C.;Edwards, S.A.;Hsia, L.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.9
    • /
    • pp.1328-1333
    • /
    • 2009
  • To evaluate different housing systems, 80 gilts were randomly allocated at puberty to four treatments: i) sow stall in gestation followed by farrowing crate (SC), ii) group housing with individual feeding in gestation followed by farrowing crate (GC), iii) ESF (Electronic Sow Feeding) system in gestation followed by farrowing crate (EC), and iv) ESF system followed by group farrowing pen (EG). The results showed that stalled sows had a longer interval between puberty and second estrus (p<0.001). The sows kept in the ESF system gained more body weight (p<0.01) and backfat (p<0.05) prior to service, and more backfat during gestation (p<0.05), but also had greater backfat losses in the subsequent lactation (p<0.01). Sows changing from loose housing to confinement at farrowing had longer gestation length (p<0.001). Total litter size did not differ significantly between gestation treatments, but the number of stillborn piglets was significantly higher in the SC treatment (p<0.01). After weaning, SC sows had the longest interval for rebreeding (p<0.001). Some EG sows came into heat before weaning, giving this treatment the shortest interval. These results indicate that gestation confinement in sow stalls had several detrimental effects on sow performance relative to group housing.

A Study on the Methodology of Qualitative Reasoning Using Centroid-Oriented Composite Interval (무게중심 복합구간에 의한 정성 추론 기법에 관한 연구)

  • 박천경;김성근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1351-1362
    • /
    • 1992
  • Qualitative models in model-based expert system needs modeling paradigm which provides intelligent control of modeling assumptions and extracts robust inferences without quantitative information about the system to be modeled. Qualitative reasoning methodologies has proved the property of the completeness but not the soundness to the corresponding quantitative model. We propose new methodology of qualitative reasoning by introducing the concept of Centroid-Oriented Composite Interval to improve the soundness problem. Arithmetic operations and equivalence classes were composed using this definition. Qualitative simulation results were compared to Kuipers's results and the improvements in the soundness problem is verified.