• 제목/요약/키워드: interval load

Search Result 284, Processing Time 0.021 seconds

A Study on the Restraint Effect on Lateral Displacement of an Inclined Earth Retaining Structure Integrated with Soil Nailing in Sandy Ground (사질토지반에 설치된 소일네일 복합형 IER의 수평변위 억제효과에 관한 연구)

  • Park, Tae-Keon;Im, Jong-Chul;Yoo, Jae-Won;Kim, Chang-Young;Kang, Sang-Kyun;Lee, Woo-Je
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.10
    • /
    • pp.33-47
    • /
    • 2017
  • A self-supported temporary excavation method called IER is normally applicable to excavation depth ranging from 6.0 m to 7.0 m though the method depends on ground condition and overburden load. Combining IER with another method is required in deeper excavation depth in order to maintain the structural stability of the IER. In this study, we performed model tests and 3D FE analysis to check the stability of the IER adopting soil nailing method, and to propose its effective installation method. The lateral displacement of the IER using soil nailing decreased by 92% of that of IER without soil nailing. Optimum design is possible for both economic feasibility and stability when interval spacing and length of soil nails is $1.5m(S_h){\times}0.75m(S_v)$ and 86% of excavation depth, respectively. Excavation depth using IER increases 1.71 times by adopting soil nailing in increment of lateral displacement of IER right before the last excavation stage.

Utilization of Waste Tires as Soil Reinforcement; (1) Soil Reinforcing Effect (지반보강재로서 폐타이어의 활용; (1) 지반보강 효과)

  • 윤여원;최경순;윤길림;김방식
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.107-117
    • /
    • 2004
  • This paper is to investigate the reinforcing effects of newly devised Tire-cell mat made of waste tires in sand. Parametric study on number of connection bolts between Tirecells, relative density of sand, embedded depth, number of reinforced layers and width of Tirecell mat was made by using plate loading tests. It is found that the number of connection bolt was enough to maintain the given pressure. The bearing capacity ratio(BCR), which is defined as the rate of ultimate bearing capacity of reinforced soil to that of unreinforced soil, is the highest at the lowest density. And the reinforcing effect can be obtained in case of embedded depth within 1.0B, where B is loading width. Also settlement reduction is the highest at the lowest density of sand. The effect of number of Tirecell reinforced layers with 0.4B to 0.5B interval is limited to 2 layers and further reinforcing effects can not be obtained beyond 3 layers. Especially, the bearing capacity increased remarkably at 1 layer of reinforcement and the degree of increase was small from 1 layer to 2 layers of reinforcement. The effect of mat width of Tirecell was not significant because of high stiffness of Tirecell although the maximum bearing capacity was shown at the 2.0B mat width and the reinforcing effects of Tirecell, in general, was prominent compared with those of commercial Geoweb.

Development of Multi-span Plastic Greenhouse for Tomato Cultivation (토마토 재배용 연동 플라스틱 온실 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Kim, Young Chul
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.428-436
    • /
    • 2012
  • This study aimed to develop the multi-span plastic greenhouse which is suitable for tomato cultivation and is safe against climatic disasters such as typhoon or heavy snow. The width and heights of eaves and ridge of newly developed tomato greenhouse are 7, 4.5 and 6.5 m, respectively. The width is the same but the eaves and ridge heights are 1.8 and 2 m higher than conventional 1-2 W greenhouses, respectively. Cross beam has been designed as a truss structure so it can sustain loads of tomato and equipment. Tomato greenhouse has been designed according to climatic disaster preventing design standard maintaining the high height. In other words, the material dimensions and interval of materials including column and rafter have been set to stand against $40m{\cdot}s^{-1}$ of wind and 40 cm of snow. Tomato greenhouse has been equipped with rack-pinion type roof vents which have been used in glass greenhouse in order to prevent excessive rise in air temperature. This vent type is different from that of 1-2 W type greenhouse which is made by rolling up and down the vinyl at upper part of column. Roof vents are installed at ridge, and thus external air inflow and natural ventilation are maximized. As the height increases, heating cost increase as well and, therefore, tomato greenhouse has been equipped with multi-layered thermal curtain, of which thermo-keeping is excellent, to prevent heat from escaping.

Suggestions on Time-saving Processes of Receiving Medicines at the Outpatient Pharmacy in a University Hospital (일개 대학병원의 투약대기시간 단축방안)

  • Yu, Mi Seon;Park, Hye Soon;Park, Hyoun Jung;Kim, Ji Hwa;Kim, Hee Jeoung;Kim, Sun Young
    • Quality Improvement in Health Care
    • /
    • v.5 no.1
    • /
    • pp.28-40
    • /
    • 1998
  • Background : Many patients have been frequently complaining that they have to spend couples of hours in hospital on visiting outpatient clinic. Among several steps, two major time consuming steps were waiting to see a doctor and/or waiting at pharmacy to get medicine. Therefore not only to provide the proper guidance for medication or counseling on health affairs but also to make waiting time short is very important for the better hospital services. The aim of this study is to validate several time-saving processes to reduce waiting time at outpatient pharmacy and its efficacy. Methods : We surveyed the time interval actually taken to receive medicine after issuing prescription by doctors, and analyzed the data on the bases of relevant or possible causative factors. Then following processes were given to reduce waiting time and resurveyed and compared both data to validate efficacy of those processes : 1. No work-off on Monday and Tuesday 2. Work hour shift to start 30 minutes earlier 3. Changeable work shift between outpatient pharmacy and ward pharmacy according to work load 4. Use of pre-made medicines prescribed more frequently by certain doctors at certain time 5. Cooperation with doctors to use set prescriptions. Results : Before the process, mean waiting time at pharmacy was 29.2 minutes and most time consuming period was from noon to 1 PM, 3 to 4 PM, 1 to 2 PM in order of frequency. Only 37.7 % of patients could get the medicine within 20 minutes. Three times of surveys after process showed mean waiting time at pharmacy were 18.1 minutes, 19.0 minutes, and 17.6 minutes, respectively. And 72.7 %, 81.3%, and 82.2% of patients could get the medicine within 20 minutes. Conclusion : The mean waiting time was markedly reduced with above mentioned processes which applied intradepartmently event hough with little cooperation from other department. Consequently, the complaints of patients were decreased with increasing the satisfaction degree. In conclusion, those suggestions were recommanded to improve the degree of satisfaction of patients.

  • PDF

Analysis of Mechanical Properties and Stress Crack Behavior of HOPE Geomembranes by Laboratory Installation Damage Test (실내 시공시 손상시험에 의한 HDPE 지오멤브레인의 기계적 특성 및 응력균열거동 해석)

  • Khan, Belas Ahmed;Park, Ju-Hee;Kim, Sung-Hee;Chang, Yong-Chai;Oh, Tae-Hwan;Lyoo, Won-Seok;Jeon, Han-Yong
    • Polymer(Korea)
    • /
    • v.35 no.3
    • /
    • pp.203-209
    • /
    • 2011
  • Two smooth and textured surfaced HDPE geomembranes (GMs) were cut into dumbbell shape and notched where depth of the notch produced a ligament thickness of 10% to 90% of the nominal thickness with the specimen at 10% interval. A series of laboratory simulation test for installation damage were carried out at different loading cycles on HDPE GMs in accordance with ISO 10722 test method and the effect of number of loading cycle on installation damage was compared. It was found that yield stress and elongation at yield point decreased gradually as the notch depth was increased. Both installation damaged and notched, GMs were used to understand stress crack behavior and this behavior was observed through NCTL test at $50{\pm}1^{\circ}C$ at different yield stresses immerging in pH 4 and pH 12 buffer solutions. Over 35% tensile load, GMs became vulnerable to stress cracking. Both damaged and notched GMs showed the same trend. Especially, notched GMs showed less strength than installation damaged GMs at every stress cracking test condition.

Pillar stability in very near-twin tunnels (초근접 병설터널의 필라 안정성 확보)

  • Kim, Donggyou;Koh, Sungyil;Lee, Jeongyong;Lee, Chulhee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.699-714
    • /
    • 2022
  • The objective of this study is to suggest a safe and economical pillar reinforcement method when very near-twin tunnels with a minimum interval of 1 m passes through a soft zone such as weathered soil or weathered rock. A standard cross-sectional view of a two-lane road tunnel was applied to suggest a pillar reinforcement method for the very near-twin tunnels. The thickness of the pillar was 1 m. The ground condition around the tunnel was weathered soil or weathered rock. There were four reinforcement methods for pillar stability evaluation. These were rock bolt reinforcement, pre-stressed steel strand reinforcement, horizontal steel pipe grouting reinforcement, horizontal steel pipe grouting + prestressed steel strand reinforcement. When the ground condition was weathered soil, only the pillar reinforced the horizontal steel pipe grouting + prestressed steel strand did not failed. When the ground condition was weathered rock, there were no failure of the pillar reinforced the horizontal steel pipe grouting or the horizontal steel pipe grouting + prestressed steel strand. It is considered that the horizontal steel pipe grouting reinforcement played a role in increasing the stability of the upper part of the pillar by supporting the upper load applied to the upper part of the pillar.

A Study on Optimal Design of Hybrid System of New and Renewable Energy-Linked Microgrid (신재생에너지 연계형 마이크로그리드의 하이브리드시스템 최적 설계 연구)

  • Lee, Jae-Kyung;Han, Yong-Chan;Kwon, Sung-Gi;Park, Gye-Choon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.631-638
    • /
    • 2022
  • Microgrid, which enables the production and consumption of electricity to be done independently on a small scale, has been studied on one of the solutions of reinforcement for flexibility of electronic system. This study examined the application effect of new microgrid by applying hybrid battery in electric power storage device. We designed the system to highlight the advantage of each battery and complement the disadvantage by using hybrid system with Lithium-ion battery and interval Redox flow battery. It runs with lithium-ion battery during the initial startup while the Redox flow battery operates for a long time at the end of excessive period, and it enables a discharge of Lithium-ion and Redox flow battery at the same time when the load has a large output. We chose Maldives as a subject of this study for organizing and optimizing independent microgrid. Maldives is the country to accomplish 100% domestic electricity in South Asia, but the whole electric power is supplied through diesel generation imported fossil fuel. We organized and optimized microgrid for energy independence on Malahini island to solve Maldives energy cost problem and global energy environment matters. We analyzed the daily power supply and accumulated the power supply from September 18, 2018~February 11, 2019. The accumulated power supply was about 120.4 MWh and the daily power supply was about 800~1000 kWh. Based on the collected information, we divided the cases into three models which are only diesel generator, solar generator as well as diesel generator, and solar+ESS+diesel generator. We analyzed the amount of oil consumption compared to the cost of construction and power output. The result showed that solar+ESS+diesel generator was most economically feasible. As well, we obtained that our considering hybrid battery system reduced the fuel consumption for diesel power generation about 10~15%.

Changes of Stream Water Quality and Loads of N and P from the Agricultural Watershed of the Yulmunchon Tributary of the Buk-Han River Basin (북한강 율문천 소유역에서 수질 변화와 농업활동에 의한 N, P 부하량)

  • Jung, Yeong-Sang;Yang, Jae E.;Park, Chol-Soo;Kwon, Young-Gi;Joo, Young-Kyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.2
    • /
    • pp.170-176
    • /
    • 1998
  • Nitrogen and phosphorus loads from an agricultural watershed of the Yulmun-chon tributary in the Buk-Han River Basin were quantified based on total amounts of water stream flow. The water quality and soil loss were estimated. Levels of the stream were recorded automatically using the water level meter. The flow velocities, along with the cross-sectional areas of the riverbed, were measured to estimate total amounts of water flow at three monitoring sites in this tributary. Water samples were collected at nine sites with two weeks interval from May to August and analyzed for the water quality parameters. Amounts of soil loss were estimated by the USLE. The size of the Yulmunchon watershed was 3,210 ha, of which paddy and upland soil areas were composed about 41%. The total amounts of soil loss from the watershed areas were estimated to be $13,273Mg\;year^{-1}$, showing 53%, 46% and 0.7% of the soil loss ratio from upland, forest, and paddy areas, respectively. Electrical conductivities and Nitrogen concentrations of the stream water were higher in the lower watershed area than in the upper area. Increments of N were higher for $NO_3-N$ than $NH_4-N$. Nitrate nitrogen was the major N form to pollute the water due to the agricultural activity. Total runoff was about 72% of the total precipitation in the watershed. The maximum loads of T-N and T-P due to the runoff were estimated to be 1,500 and $5kg\;day^{-1}$, respectively. Concentrations of $NO_3-N$ and $NH_4-N$ in the runoff were 13.5 and 1.8 times higher than those in precipitation. The N loads were mainly from soil loss, application of fertilizer, and livestock wastes, which were 52% of total N load. Results demonstrated that reduction of fertilizer use and the soil loss would be essential for water quality protection of the agricultural watershed.

  • PDF

Contamination of the Mushim-Cheon and its Countermeasures;I. Analysis of the Water Samples in Summer (무심천 수질 오염 실태와 그 방지책;I. 하계절의 수질 오염 분석)

  • Lee, Jea-Koo;Kyung, Kee-Sung;Kim, Hak-Nam;Oh, Kyeong-Seok
    • Korean Journal of Environmental Agriculture
    • /
    • v.9 no.1
    • /
    • pp.23-37
    • /
    • 1990
  • In order to disclose the contamination of the Mushim-Cheon by pollutants in August and September of 1989 and to establish countermeasures, the collected water samples were analyzed to obtain the following results : 1. The water temperature of the period ranged from 25.8 to $30.8^{\circ}C$ acceptable for the growth of microorganisms and algae to allow the self-purification of the stream. 2. The pHs at the sites during the same period ranged from 6.5 to 8.5 which fall within the allowed values for the first grade water supplies except for site 14. 3. At site 18 which is the confluence of the sewer of the excretion disposal facilities and the main stream, the DO was observed to fall down to 0.7 ppm in September. 4. The BOD value reached a maximum of 62.1 ppm at site 18, which far exceeded the limit of 40 ppm, the allowed value for the discharges from the disposal facilities. In addition, the SS values were 200 and 520 ppm in August and September, respectively, which were three to seven times as high as the allowed limit of 70 ppm. 5. The high $NH_3-N$ value of 46.2 ppm at site 18 in September suggested that the water was heavily contaminated with excretions. 6. The BOD load of the sewage from site 12, the Sajik-Dong Sewer, in September was estimated to be about 0.306 ton/day. 7. The contamination of the influents, the family wastewater, and the discharges from the disposal facilities was greater than that of the main stream. 8. In the samples collected from site 12, the Sajik-Dong sewer at an interval of every two hours, a close correlation was observed between the pollutant load and the life cycle of the nearby inhabitants. 9. Compared with the results obtained from the water samples in 1979, it was observed that the water was heavily contaminated at site 12 (the Sajik-Dong Sewer, under the Chung Ju Great Bridge) and site 15 (Under the 2nd Uncheon Bridge) over the last 10 years, with little difference at site 9(Young Un-Dong water supply source).

  • PDF

Diagnosis of Irrigation Time Based on Microchange of Stem Diameter in Greenhouse Tomato (온실재배 토마토의 농직경 변화에 의한 관개시기 진단)

  • 이변우
    • Journal of Bio-Environment Control
    • /
    • v.6 no.4
    • /
    • pp.250-257
    • /
    • 1997
  • Stem diameter and shoot fresh weight of tomato grown in greenhouse were measured non-destructively at 10 minutes interval from 1 to 16 July, 1996 with displacement detector using strain gauges and with suspension-type load cell, respectively, and simultaneously were measured soil water potential, transpiration and solar radiation. Ample water was irrigated before experiment, and thereafter, irrigations were made on the next morning when visual symptoms of wilting appeared. Shoot fresh weight and stem diameter showed very similar patterns in diurnal changes which are characterized by predawn maximum and afternoon minimum and in long- term evolutions, suggesting that stem diameter shrinkage and expansion are closely related to plant water content and growth, respectively, Shoot weight and stem diameter reached minimum values a little later than the time on which transpiration showed maximum. The daily net gains of fresh weight(DG) and stem diameter(DI) showed significantly Positive correlations with solar radiation in those days on which plants were not water-stressed. However, Dl and DG on those days of water stress showed much lower values than expected from the relationships between solar radiation and them. Transpiration was much lower than the expected potential transpiration on 10 July, implying that plants were water-stressed. In this case water stress was not detected from visual symptom of wilting and/or soil water potential, but was able to be identified by the lower DI and DG than the expected. The maximum contraction of stem diameter(MC) and the maximum loss of fresh weight(ML) during daytime showed significantly positive correlations with solar radiation in those days on which plants were not water-stressed and were observed greater than expected from the relationships on severely water-stressed days. But mild water stress could not be discernable by ML and MC. It would be concluded that the daily net gains of fresh weight and/or stem diameter could be used as criteria for diagnosing the water status of tomato and for triggoring the onset of irrigation in automatic system.

  • PDF