Contamination of the Mushim-Cheon and its Countermeasures;I. Analysis of the Water Samples in Summer

무심천 수질 오염 실태와 그 방지책;I. 하계절의 수질 오염 분석

  • Lee, Jea-Koo (Department of Agricultural Chemistry, College of Agriculture, Chung Buk National University.) ;
  • Kyung, Kee-Sung (Department of Agricultural Chemistry, College of Agriculture, Chung Buk National University.) ;
  • Kim, Hak-Nam (Department of Agricultural Chemistry, College of Agriculture, Chung Buk National University.) ;
  • Oh, Kyeong-Seok (Department of Agricultural Chemistry, College of Agriculture, Chung Buk National University.)
  • 이재구 (충북대학교 농과대학 농화학과) ;
  • 경기성 (충북대학교 농과대학 농화학과) ;
  • 김학남 (충북대학교 농과대학 농화학과) ;
  • 오경석 (충북대학교 농과대학 농화학과)
  • Published : 1990.06.30

Abstract

In order to disclose the contamination of the Mushim-Cheon by pollutants in August and September of 1989 and to establish countermeasures, the collected water samples were analyzed to obtain the following results : 1. The water temperature of the period ranged from 25.8 to $30.8^{\circ}C$ acceptable for the growth of microorganisms and algae to allow the self-purification of the stream. 2. The pHs at the sites during the same period ranged from 6.5 to 8.5 which fall within the allowed values for the first grade water supplies except for site 14. 3. At site 18 which is the confluence of the sewer of the excretion disposal facilities and the main stream, the DO was observed to fall down to 0.7 ppm in September. 4. The BOD value reached a maximum of 62.1 ppm at site 18, which far exceeded the limit of 40 ppm, the allowed value for the discharges from the disposal facilities. In addition, the SS values were 200 and 520 ppm in August and September, respectively, which were three to seven times as high as the allowed limit of 70 ppm. 5. The high $NH_3-N$ value of 46.2 ppm at site 18 in September suggested that the water was heavily contaminated with excretions. 6. The BOD load of the sewage from site 12, the Sajik-Dong Sewer, in September was estimated to be about 0.306 ton/day. 7. The contamination of the influents, the family wastewater, and the discharges from the disposal facilities was greater than that of the main stream. 8. In the samples collected from site 12, the Sajik-Dong sewer at an interval of every two hours, a close correlation was observed between the pollutant load and the life cycle of the nearby inhabitants. 9. Compared with the results obtained from the water samples in 1979, it was observed that the water was heavily contaminated at site 12 (the Sajik-Dong Sewer, under the Chung Ju Great Bridge) and site 15 (Under the 2nd Uncheon Bridge) over the last 10 years, with little difference at site 9(Young Un-Dong water supply source).

무심천의 오염실태와 그 방지책을 강구하기 위하여 1989년 8월과 9월 2회에 걸쳐 채수한 수질을 분석하여 다음과 같은 결과를 얻었다. 1. 8, 9월의 주간 무심천 수온은 미생물과 조류의 생육에 지장이 없는 것으로 보이는25.8-$30.8^{\circ}C$로써 자정능력이 있는 것으로 판단되었다. 2. 동 기간중 무심천수의 pH는 St 14를 제외하고는 6.5-8.5 범위이었다. 3. St 18(분뇨처리장 배수구와 무심천의 합류지점)에서 9월에 DO가 0.7 ppm까지 내려가는 현상이 관찰되었다. 4. St 18에서 BOD가 최고 62.1 ppm으로써 분뇨 처리장 방류수의 BOD 허용치인 40 ppm 을 크게 초과하였다. 또한 SS도 8, 9월에 각각 200과 520ppm으로써 허용치인 70 ppm을 3-7배 초과 하였다. 5. St 18에서 9월중에 $NH_3-N$이 46.2 ppm이나 되는 것은 분뇨로 크게 오염되어 있음을 말해 준다. 6. 9월중 사직동 하수의 BOD 부하량은 약 0.306ton/day이었다. 7. 무심천 본류보다 무심천으로 유입되는 지천과 가정하수구 및 분뇨처리장 방류수에서 오염도가 훨씬 높았다. 8. St 12(사직동 하수)의 2시간별로 채수한 시료에서 오염물질의 부하량이 인근 주민의 생활주기와 밀접한 관계가 있음을 알 수 있었다. 9. 1979년 무심천 수질 분석 결과와 비교해 볼 때 영운동 취수장(St 9)에서는 큰 차이가 없었으나 사직동 하수(청주대교 밑, St 12)와 제2운천교(St 15)에서는 최근 10년 동안 수질이 더욱 악화되었음을 알 수 있다.

Keywords