• Title/Summary/Keyword: internal water pressure

Search Result 289, Processing Time 0.028 seconds

Development of Water Meters for Frozen Inflation Pressure Absorption Based on Structural Analysis (구조해석 기반 동결팽창압 흡수용 수도미터 개발)

  • Kim, Kuk-il;An, Sang-byung;Lee, Byung-sun;Hong, Sung-taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.314-316
    • /
    • 2022
  • Instrumentation device to the amount of water used by the user is a water meter by measuring management stability is necessary. But with the onset of winter to meter water was ice inside the phase change and about 9 % and increase the volume of the meter is damaged. The existing protection bleed water meter freeze protection technology into three great bootong, supplying the heat insulation inside the external protection, water metering for water meter in the freeze protection will be divided into installing the device. Not see how far the structure for the commercialization of new technology-based products and aims to develop technologies that do not require an external power supply. Thus, freeze more vulnerable by internal pressure of the interpretation applied to a water meter in temperatures below zero internal pressure to confirm the area of preventing damage and freeze protection that can reduce the effect is superior to develop a water meter.

  • PDF

Evaluation on Water Vapor Pressure and Restrained Stress of Concrete by Ring-Type Restrained Condition (링형 강관 구속 조건에 의한 콘크리트의 수증기압력과 구속응력 평가)

  • Kim, Do-Yeon;Kim, Gyu-Yong;Lee, Sang-Kyu;Son, Min-Jae;Baek, Jae-Wook;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.27-28
    • /
    • 2018
  • In this study, water vapor pressure and restrained stress were evaluated by ring-type restrained condition for compressive strength 60 and 80MPa concrete. Experimental results show that the 80MPa concrete has higher water vapor pressure and restraint stress than the 60MPa concrete, resulting in spalling occurrence. It is because, the higher the compressive strength of the concrete, the more dense the internal structure is formed.

  • PDF

Characteristic of the Permeation Flux of Hollow Fiber Membranes by Process Pressures Change (공정압 변화에 따른 중공사막의 투과플럭스 특성)

  • Lee, Yong-Taek;Kim, Nam-Su;Shin, Dong-Ho
    • Membrane Journal
    • /
    • v.17 no.4
    • /
    • pp.318-328
    • /
    • 2007
  • This study was carried out to evaluate the performance of the separate membrane (HF; hollow fiber membrane with polysulfone) process applied with the external membrane types, internal pressure membrane types and external-internal types according to the variations of pressure and membrane pore size in the purification treatment process of the lake water. The maximum permeate flux was average values of 282 LMH and 234 LMH with the pore size of 0.3 and 0.05 ${\mu}m$ respectively in the external pressure membrane process, and 443 LMH and 522 LMH with the pore size of 0.3 and $0.05{\mu}m$ respectively in the internal pressure membrane process. In addition, the maximum permeate flux of the process that was applied with external and internal membrane pressure simultaneously showed the average values of 674 LMH with the pore size of $0.3{\mu}m$, and 648 LMH with the pore size of $0.05{\mu}m$. Therefore, maximum yield per unit area is supposed when the separate membrane that was applied with external and internal pressure simultaneously are used to treat the lake water.

Failure Behavior of T-joint Pipe with Outer Local Wall Thinning under Internal Pressure (내압을 받는 외부 국부 감육 T-joint 배관의 파손거동)

  • Kim, Soo-Young;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.80-87
    • /
    • 2014
  • The pipelines are apt to erosion or corrosion because of the high-speed flow of water and steam with high temperatures or high pressures. This study was carried out a finite element analysis (FEA) and an experimental for the fracture behavior of T-joint pipes with local wall thinning under internal pressure. Local wall thinning was machined on the pipes in order to simulate erosion and corrosion of the metal. The configurations of the eroded area included an eroded ratio of d/t=0.80~0.963 and an eroded length of l=25 mm, 50 mm, and 102 mm. Three-dimensional elastic-plastic analyses were also carried out using FEA, which accurately simulates failure behaviors. In regards to the relationship between pressure and eroded, the criterion that indicates what can be used safely under operating pressure and design pressure were obtained from FEA. The FEA results were in relatively good agreement with that of the experiment.

Effect of Choakwiyeum and Yukmijihwang-tang Water Extract on the Renal Aldosterone Concentration in Rabbits (좌귀음과 육미지황탕 전탕액 투여가 가토신기능 및 혈장 Aldosterone농도에 미치는 영향)

  • Choi Woo Jung;Lee Eon Jeon;Kim Hyeong Kyun;Lee Kwang Suk;Lee Dae Young;Jung Dae Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.6
    • /
    • pp.1263-1269
    • /
    • 2002
  • To evaluate the effect of Choakwiyeum(CKY) and Yukmijihwang-tang(YJT) water extract on the renal function and the levels of plasma aldosterone, this experiment was performed in the rabbbits. These result indicate that increase in urine volume(UV) after administration of CKY and YJT water extract is related to increase in glomerular filtration rate(GFR), free water clearance(FWC) and renal plasma f1ow(RPF) and also to decrease in plasma aldosterone concentration(PAC), which seems to be affected by renin-angiotensin-aldosterone system, and that reduced blood pressure seems to be caused by reduced peripheral resistance.

Erosion behavior according to location of conduit cracks in agricultural reservoir

  • Ryu, Jung-Hyun;Heo, Joon;Shim, Jae-Woong;Kim, Cheol-Han;Yun, Bora;Lee, Yong-Hak;Lee, Dal-Won
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.1159-1168
    • /
    • 2020
  • The conduits of agricultural reservoirs undergo deterioration over a considerable period of time and this is highly likely to cause structural problems such as cracks. It is therefore important to consider the effects of structural defects on the body from the viewpoint of stability and maintenance of the embankment. In this study, basic data on the effects of the crack location on the stability of the embankment is obtained by identifying, comparing, and analyzing the erosion characteristics and pore water pressure behavior through a large-scale model experiment that involves classifying the location of the conduit cracks. From the results of the experiment, it was confirmed that when a crack occurred, the amount of leakage increased as the location of the crack portion was closer to the water level, and the internal erosion phenomenon accelerated, thereby increasing the possibility of piping. It was also found that an upstream conduit crack affects the erosion and water pressure change of the central and downstream conduit of the embankment, and the conduit crack has a very large effect on the pore water pressure despite the low upstream water level. Therefore, the seepage behavior of the embankment for each conduit crack identified in this study is considered to be useful basic data for preparing a repair and reinforcement plan according to the crack location in the future.

Effects of Boganhwan Water Extract on the Cardiovascular System in Rabbits (보간환(補肝丸) 전탕액(煎湯液)이 가토(家兎)의 심혈관계(心血管系)에 미치는 영향(影響))

  • Ku, Won-Hae;Moon, Byung-Soon
    • The Journal of Internal Korean Medicine
    • /
    • v.17 no.1
    • /
    • pp.8-33
    • /
    • 1996
  • The present experiment was designed to understand the effect of Boganhwan on the cardiovascular system in experimental animals. And thus the Blood pressure, isometric movement of atrium,Mg++-Ca++-ATPasc activity of sarcoplasmin reticulum. liver function, prothrombin time, and changes of blood composition were measured in the presence of Boganhwan. The results obtained here were as following: 1. The blood pressure decreased in the presence of SAMOOLTANG, and the decreasing effect was more stimulated by adding Bangpoong and Ganghwa(Boganhwan) 2. The oral administration of the drug for 7days also demonstrated the decreasing of blood pressure and the effect was stimulated by adding Bangpoong and Kanghwal. 3. The autonomic nerve blocking agents such as atropine and regitine did not demonstrate the effect on the drug action. 4. Boganhwan inhibited the cardiac isometric movement and rate by stimulating the Mg++-Ca++-ATPase activity of the heart sarcoplasmins reticulum. 5. Boganhwan increased the number of red blood cell, hematocrit percentage, hemoglobin concentration, and prothrombin time. 6. The drug stimulated the liver metabolism by stimulating the total ATPase activity. According to the results. Boganhwan demonstrated the decreased blood pressure and it also increased the hemoglobin concentration and the hematocrit percent. These effects stanches the hypertension. anemia, and cerebrovascular accident.

  • PDF

A Comparison of Controlled and Uncontrolled Hypertension Groups Regarding Comprehensive Diagnosis of Qi Blood Water and Quality of Life (고혈압 환자에서 혈압 조절 여부에 따른 기혈수(氣血水) 변증(辨證)과 삶의 질 비교)

  • Choi, In-Young;Han, Chang-Ho;Choi, Dong-Jun;Jung, Seung-Hyun;Shin, Gil-Jo
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.4
    • /
    • pp.880-891
    • /
    • 2010
  • This study is about a comparison of controlled and uncontrolled hypertension groups regarding comprehensive diagnosis of Qi blood water and quality of life. We surveyed "controlled and uncontrolled hypertension patients" using questionnaires for comprehensive diagnosis of Qi blood water, SF-36 and HTN QoL (Measurement Scale for the quality of life in hypertensive patients). There was no difference in comprehensive diagnosis of Qi blood water between the controlled and uncontrolled hypertension groups. Within the controlled hypertension group, the patients diagnosed with a Qi deficiency, Qi stagnation, Qi counterflow, blood deficiency, and water retention received lower total scores in SF-36 and HTN QoL than in undiagnosed patients. Within the uncontrolled hypertension group, the patients diagnosed with Qi deficiency, blood deficiency, and water retention got lower total scores in SF-36 and HTN QoL than in undiagnosed patients. These results were statistically significant. These results are insufficient that we and use comprehensive diagnosis of Qi blood water for a diagnosis tool of hypertension. But if we have better studies that make up for weak points, these results will help to make a diagnosis tool for hypertension.

Effect of the Presence of Sub-pipes on the Performance of Water Nozzle (서브파이프의 유무에 따른 워터노즐의 성능특성연구)

  • Yi, Young-Woo;Lim, Hee-Chang
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.17-24
    • /
    • 2018
  • This paper presents a numerical analysis of flow inside a water nozzle for fire fighting and observes the effect of the variation in primary components on internal flow. In order to observe the performance of water nozzles, they have been systematically designed and modelled, applying boundary conditions obtained from field experiments (inlet pressure at pump : 4 bar, and pressure outlet : atmospheric pressure). In addition, the governing equations were calculated to obtain velocity, pressure inside the nozzle. Two main parameters (the presence and length of sub-pipes) were considered with the aim to observe the detail internal flow characteristics. It is found that the base model is not significant on flow characteristics, but a negative effect (i. e. the reverse flow) at the entrance region of sub-pipe. On the other hand, the reverse flow was vanished when making the length of sub-pipe double.

Study on Leak Rate of SCC Degraded Alloy 600 Tubings of PWRs

  • Hwang, Seong Sik;Kim, Joung Soo;Kasza, Ken E.;Park, Jangyul
    • Corrosion Science and Technology
    • /
    • v.3 no.6
    • /
    • pp.233-239
    • /
    • 2004
  • Primary water stress corrosion cracking of steam generator tubings occur on many tubes in pressurized water reactors(PWRs), and they are repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to know the leak behavior of the tubes, which have stress corrosion cracks. Crack development tests were carried out on the tubes at room temperature, and leak rate and burst pressure were measured on the degraded tubes at room temperature and a high temperature. No leakage was detected on the tubes where 100 % through wall crack developed, at 1560 psi, which is an operating pressure difference of pressurized water reactors(PWRs). In some tests, leak rates of the tubes increased with time at a constant internal water pressure. A test tube showed a very small amount of leakage at 2700 psi in a high temperature pressure test at $282^{\circ}C$, but it disappeared after the pressure increased slightly. Even cracks are 100 % through wall, they need to open in order to reach a certain amount of leak rate at the operating pressure difference.