• Title/Summary/Keyword: internal resistance

Search Result 1,270, Processing Time 0.026 seconds

Early Bronchoconstriction After Allergen Challenge of Nonanesthetized Guinea Pigs (Ovalbumin으로 감작된 기니픽에서 Allergen 흡입으로 인한 즉시형 기관지 수축반응에 대한 비침습적 측정)

  • Kim, Je-Hyeong;Shim, Jae-Jeong;Lee, Sung-Yong;Kwon, Young-Hwan;Lee, So-Ra;Lee, Sang-Youb;Cho, Jae-Youn;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.99-106
    • /
    • 1998
  • Background: Bronchial asthma is a complex disease, which is characterized by spontaneous exacerbations of airway obstruction and persistent bronchial hyperresponsiveness. Animal models have fallen short of reproducing the human disease, particularly in mimicking the spontaneous and persistent airflow obstruction that characterized in asthma. In animals, airflow obstruction is usually assessed by measuring airflow resistance during tidal breathing under such invasive technique as tracheostomy and anesthesia. A noninvasive technique for measuring pulmonary function in small animals is needed to evaluate long-term changes in lung function during the course of experimentally produced disease without sacrificing the animal. Purpose: The purpose of this study was to evaluate early bronchoconstrcition after allergen challenge and airway responsiveness (AR) to inhaled methacholine in nonanethetized, unrestrained guinea pigs. Method: Guinea pig model of asthma was sensitized by subcutaneous injection with ovalbumin and challenged by inhalation of aerosolized ovalbumin(1% wt/vol ovlabumin). Airflow obstruction of conscious guinea pig was measured as specific airway resistance (airway resistance $\times$ thoracic gas volume). Airway resistance and thoracic gas volume of conscious guinea pig were assessed by body plethysmography before challenge and at regular intervals for as long as 30 minutes after challenge. AR to aerosolized methacholine of asthma group was compared with that of control group in body plethysmography. Result: Asthma model<> developed in 13 (65%) among 20 guinea pigs, in which early responses occurred in the airways after the exposure to inhalation with ovalbumin. Airway challenge with ovalbumin caused increase in specific airway resistance, which peaked at 6 minutes and amounted to a $231.5{\pm}30.4%$ increase from baseline. AR to aerosolized methacholine of asthma model increased significantly compared with control group. Conclusion: These results have showed a useful animal model to evaluate early bronchoconstrcition after allergen challenge and airway responsiveness in nonanethetized, unrestrained guinea pigs.

  • PDF

Predictors of Drug-resistance in Patients with Pulmonary Tuberculosis (폐결핵환자에서 약제내성의 예측인자)

  • Koh, Hyung-Ki;Kang, Yoon-Jung;Lim, Sung-Yong;Shin, Jong-Wook;Choi, Jae-Sun;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.311-316
    • /
    • 1999
  • Background: The drug-resistant tuberculosis has recently decreased in Korea, but it is still one of the major obstacles in the treatment of pulmonary tuberculosis. Unfortunately there are no reliable ways to figure out the drug sensitivity pattern of the M. tuberculosis in the starting point of treatment. At least several months which is critical for the success of treatment have to be passed away before getting the report of drug-sensitivity test. The aim of this study was to find out the clinical and radiological parameters that make it possible to predict the drug-resistant pulmonary tuberculosis and to make a correct decision on the antituberculosis drug regimens. Method: We studied 253 pulmonary TB patients with sputum and/or bronchial washing fluid culture-positive diagnosed at the Chung-Ang University Young-San Hospital in the period of 1989-1994. The differences in the clinical and raiological variables between the drug-sensitive and the drug-resistant tuberculosis patients were evaluated. Results: In 66 out of 253 patients(26.1%), drug resistant tuberculosis to at least one antituberculosis drug were found. Patients with retreatment showed higher resistance rate than those with initial treatment(30/69, 43.5% vs 36/184, 19.5%, p<0.01). Patients with cavitary TB showed higher resistance rate than those with non-cavitary TB(24/54, 44.4% vs 42/199, 21.1%, p<0.05). Among patients with initial treatment, those with far-advanced TB showed a higher drug resistance rate than those with minimal lesion(9/23, 36.9% vs 10/82, 12.5%, p<0.05). Patients with culture positive only in the bronchial washing fluid showed lower resistance rate than those with sputum culture positive(7/63, 11.1 % vs 59/190, 31.1%, p<0.05). Conclusion: Prior treatment history for pulmonary tuberculosis, the presence of cavity & far advanced tuberculosis in the radiologic exam, sputum rather than solely bronchial washing culture positivity would be the related factors to the drug resistance. So in the patients with such characteristics, it is needed to try to find out the drug sensitivity pattern of the infecting tuberculosis organism as soon as possible.

  • PDF

Head-to-Head Comparison between Xpert MTB/RIF Assay and Real-Time Polymerase Chain Reaction Assay Using Bronchial Washing Specimens for Tuberculosis Diagnosis

  • Son, Eunjeong;Jang, Jinook;Kim, Taehwa;Jang, Jin Ho;Chung, Jae Heun;Seol, Hee Yun;Yeo, Hye Ju;Yoon, Seong Hoon;Lee, Seung Eun;Cho, Woo Hyun;Kim, Yun Seong;Jeon, Doosoo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.1
    • /
    • pp.89-95
    • /
    • 2022
  • Background: With the introduction of Xpert MTB/RIF assay (Xpert), its incorporation into tuberculosis (TB) diagnostic algorithm has become an important issue. The aim of this study was to evaluate the performance of the Xpert assay in comparison with a commercial polymerase chain reaction (PCR) assay. Methods: Medical records of patients having results of both Xpert and AdvanSure TB/NTM real-time PCR (AdvanSure) assays using the same bronchial washing specimens were retrospectively reviewed. Results: Of the 1,297 patients included in this study, 205 (15.8%) were diagnosed with pulmonary TB. Using mycobacterial culture as the reference method, sensitivity of the Xpert assay using smear-positive specimens was 97.5%, which was comparable to that of the AdvanSure assay (96.3%, p=0.193). However, the sensitivity of the Xpert assay using smear-negative specimens was 70.6%, which was significantly higher than that of the AdvanSure assay (52.9%, p=0.018). Usng phenotypic drug susceptibility testing as the reference method, sensitivity and specificity for detecting rifampicin resistance were 100% and 99.1%, respectively. Moreover, a median turnaround time of the Xpert assay was 1 day, which was significantly shorter than 3 days of the AdvanSure assay (p<0.001). Conclusion: In comparison with the AdvanSure assay, the Xpert assay had a higher sensitivity using smear-negative specimens, a shorter turnaround time, and could reliably predict rifampin resistance. Therefore, the Xpert assay might be preferentially recommended over TB-PCR in Korean TB diagnostic algorithm.

PbSCC of Ni-base Alloys in PbO-added Pure Water

  • Kim, Joung Soo;Yi, Yong-Sun;Kwon, Oh Chul;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.316-321
    • /
    • 2007
  • The effect of annealing on the pitting corrosion resistance of anodized Al-Mg alloy (AA5052) processed by equal-channel angular pressing (ECAP) was investigated by electrochemical techniques in a solution containing 0.2 mol/L of $AlCl_3$ and also by surface analysis. The Al-Mg alloy was annealed at a fixed temperature between 473 and 573 K for 120 min in air after ECAP. Anodizing was conducted for 40 min at $100-400A/m^2$ at 293 K in a solution containing 1.53 mol/L of $H_2SO_4$ and 0.0185 mol/L of $Al_2(SO_4)_3$. The internal stress generated in anodic oxide films during anodization was measured with a strain gauge to clarify the effect of ECAP on the pitting corrosion resistance of anodized Al-Mg alloy. The time required to initiate the pitting corrosion of anodized Al-Mg alloy was shorter in samples subjected to ECAP, indicating that ECAP decreased the pitting corrosion resistance. However, the pitting corrosion resistance was greatly improved by annealing after ECAP. The time required to initiate pitting corrosion increased with increasing annealing temperature. The strain gauge attached to Al-Mg alloy revealed that the internal stress present in the anodic oxide films was compressive stress, and that the stress was larger with ECAP than without. The compressive internal stress gradually decreased with increasing annealing temperature. Scanning electron microscopy showed that cracks occurred in the anodic oxide film on Al-Mg alloy during initial corrosion and that the cracks were larger with ECAP than without. The ECAP process of severe plastic deformation produces large internal stresses in the Al-Mg alloy; the stresses remain in the anodic oxide films, increasingthe likelihood of cracks. It is assumed that the pitting corrosion is promoted by these cracks as a result of the higher internal stress resulting from ECAP. The improvement in the pitting corrosion resistance of anodized AlMg alloy as a result of annealing appears to be attributable to a decrease in the internal stresses in anodic oxide films

Usefulness of Impulse Oscillometry in Predicting the Severity of Bronchiectasis

  • Ji Soo Choi;Se Hyun Kwak;Min Chul Kim;Chang Hwan Seol;Seok-Jae Heo;Sung Ryeol Kim;Eun Hye Lee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.3
    • /
    • pp.368-377
    • /
    • 2024
  • Background: Bronchiectasis is a chronic respiratory disease that leads to airway inflammation, destruction, and airflow limitation, which reflects its severity. Impulse oscillometry (IOS) is a non-invasive method that uses sound waves to estimate lung function and airway resistance. The aim of this study was to assess the usefulness of IOS in predicting the severity of bronchiectasis. Methods: We retrospectively reviewed the IOS parameters and clinical characteristics in 145 patients diagnosed with bronchiectasis between March 2020 and May 2021. Disease severity was evaluated using the FACED score, and patients were divided into mild and moderate/severe groups. Results: Forty-four patients (30.3%) were in the moderate/severe group, and 101 (69.7%) were in the mild group. Patients with moderate/severe bronchiectasis had a higher airway resistance at 5 Hz (R5), a higher difference between the resistance at 5 and 20 Hz (R5-R20), a higher resonant frequency (Fres), and a higher area of reactance (AX) than patients with mild bronchiectasis. R5 ≥0.43, resistance at 20 Hz (R20) ≥0.234, R5-R20 ≥28.3, AX ≥1.02, reactance at 5 Hz (X5) ≤-0.238, and Fres ≥20.88 revealed significant univariable relationships with bronchiectasis severity (p<0.05). Among these, only X5 ≤-0.238 exhibited a significant multivariable relationship with bronchiectasis severity (p=0.039). The receiver operating characteristic curve for predicting moderate-to-severe bronchiectasis of FACED score based on IOS parameters exhibited an area under the curve of 0.809. Conclusion: The IOS assessed by the disease severity of FACED score can effectively reflect airway resistance and elasticity in bronchiectasis patients and serve as valuable tools for predicting bronchiectasis severity.

Analysis of Characteristics and Internal Resistance of Seawater Secondary Battery according to its Usage Environment (해수이차전지의 사용 환경에 따른 특성 및 내부 저항 분석)

  • Seung-pyo Kang;Jang-mok Kim;Hyun-jun Cho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.223-229
    • /
    • 2023
  • Seawater batteries are next-generation secondary batteries that use seawater as a cathode. They utilize marine resources to provide competitive prices, high eco-friendliness, and a structure suitable for marine applications. Based on these advantages, pouch types and prismatic types have been studied and developed assuming natural seawater exposure. However, because of the electrical characteristics of the secondary battery, its capacity and internal resistance vary depending on the use environment. These characteristics are not only utilized for predicting the life of a battery but also have a direct effect on the capacity and power suitable for a specific situation. Therefore, the internal resistance was analyzed in this study by measuring the capacity depending on the seawater battery use environment and the state-of-charge-open-circuit-voltage measurement method.

Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring (조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.

A Rotating Flux Pump Employing a Magnetic Circuit and a Stabilized Coated Conductor HTS Stator

  • Jiang, Z.;Bumby, C.W.;Badcock, R.A.;Long, N.J.;Sung, H.J.;Park, M.
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.239-243
    • /
    • 2016
  • High temperature superconductor (HTS) magnet systems usually employ metal current leads which bridge between the cryogenic environment and room temperature. Such current leads are the dominant heat load for these magnet systems due to a combination of electrical resistance and heat conduction. HTS flux pumps enable large currents to be injected into a HTS magnet circuit without this heat load. We present results from an axial-type HTS mechanically rotating flux pump which employs a ferromagnetic circuit and a Cu-stabilized coated conductor (CC) HTS stator. We show the device can be described by a simple circuit model which was previously used to describe barrel-type flux pumps, where the model comprises an internal resistance due to dynamic resistance and a DC voltage source. Unlike previously reported devices, we show the internal resistance and DC voltage in the flux pump are not exactly proportional to frequency, and we ascribe this to the presence of eddy currents. We also show that this axial-type flux pump has superior current injection capability over barrel-type flux pumps which do not incorporate a magnetic circuit.

Conducted Emission of Inverter Power Sources for Resistance Welding

  • Mecke, H.;Dobbelin, R.;Winkler, T.;Fischer, W.
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.124-129
    • /
    • 2002
  • Invertigation electromagnetic emissione of inverter power sources resistance welding existing special aspects of EMI measurements in the field of resistance welding machines resulting from the power rating and operation mode of these machines have to be taken into account. The characteristics of the internal switching processes determined by the behavior of the applied power semiconductors, sunbber circuits and constructional aspect exert a great influence on the conducted emission welding inverters.