• Title/Summary/Keyword: internal resistance

Search Result 1,259, Processing Time 0.034 seconds

Monitoring of Fill Dams for Internal Defect via Centrifuge Model Tests (원심모형시험을 이용한 필댐 취약부 모니터링)

  • Choo, Yun Wook;Cho, Sung Eun;Shin, Dong Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2C
    • /
    • pp.37-47
    • /
    • 2012
  • In this study, three centrifuge tests were performed to evaluate the feasibility of three physical quantities for detecting internal defect of earth core fill dam: pore water pressure, temperature, and electrical resistance. For this purpose, the measurement system for pore water pressure, temperature and electrical resistance on centrifuge model dams was established. Three centrifuge tests included a fill dam without internal defect and two other dams with artificial internal defect in the core. The effectiveness of seepage monitoring was examined during the centrifuge test. Test results showed the applicability of monitoring techniques to detect internal defect by monitoring pore water pressure, temperature, and electrical resistance.

The Prevalence of Initial Drug Resistance among Pulmonary Tuberculosis Patients (초치료 폐결핵 환자들에 있어서 초회 약제내성률)

  • Kong, Jae Hwan;Lee, Sang Seok;Kang, Ha Yan;Park, Jae Seuk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.2
    • /
    • pp.95-101
    • /
    • 2008
  • Background: Drug resistant tuberculosis (TB) in patients who have not received previous TB treatment (initial drug resistance) is a serious problem for the control of TB. However, prevalence of initial drug resistance among pulmonary TB patients has not been well characterized in Korea, especially in the private sector. We assessed the prevalence of initial drug resistance and evaluated the risk factors for drug resistance in pulmonary TB patients, at a regional tertiary hospital in Cheonan. Methods: We performed a drug susceptibility test for both first and second line anti-TB drugs in all culture-confirmed pulmonary TB patients who had not received a previous TB treatment at Dankook University Hospital from September 2005 to September 2007. In addition, we evaluated the initial drug resistance pattern and clinical characteristics of patients to evaluate the risk factors for initial drug resistance. We also assessed the influence of the drug susceptibility test results on the treatment regimen. Results: Of the total 156 cases where the drug susceptibility test was performed, resistance to at least one anti-TB drug was found in 21 cases (15.6%) and multidrug resistance, where TB was resistant to at least isoniazid and rifampin, was found in one case (0.6%). Multivariate logistic regression showed no clinical characteristics were independently associated with initial drug resistance. Of the total 156 patients who underwent the drug susceptibility test, the treatment regimen was changed for 15 patients (9.6%) according to the results of the drug susceptibility test. Conclusion: Initial drug resistance is common and the drug susceptibility test is informative for pulmonary TB patients who have not received previous TB treatment.

A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete (초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구)

  • Baek, Young-Woon;Yuk, Tae-Won;Park, Dong-Soo;Kim, Han-Sol;Lee, Hang-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

Effect of Annealing on the Pitting Corrosion Resistance of Anodized Aluminum-Magnesium Alloy Processed by Equal Channel Angular Pressing

  • Son, In-Joon;Nakano, Hiroaki;Oue, Satoshi;Kobayashi, Shigeo;Fukushima, Hisaaki;Horita, Zenji
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.275-281
    • /
    • 2007
  • The effect of annealing on the pitting corrosion resistance of anodized Al-Mg alloy (AA5052) processed by equal-channel angular pressing (ECAP) was investigated by electrochemical techniques in a solution containing 0.2 mol/L of $AlCl_3$ and also by surface analysis. The Al-Mg alloy was annealed at a fixed temperature between 473 and 573 K for 120 min in air after ECAP. Anodizing was conducted for 40 min at $100-400A/m^2$ at 293 K in a solution containing 1.53 mol/L of $H_2SO_4$ and 0.0185 mol/L of $Al_2(SO_4)_3$. The internal stress generated in anodic oxide films during anodization was measured with a strain gauge to clarify the effect of ECAP on the pitting corrosion resistance of anodized Al-Mg alloy. The time required to initiate the pitting corrosion of anodized Al-Mg alloy was shorter in samples subjected to ECAP, indicating that ECAP decreased the pitting corrosion resistance. However, the pitting corrosion resistance was greatly improved by annealing after ECAP. The time required to initiate pitting corrosion increased with increasing annealing temperature. The strain gauge attached to Al-Mg alloy revealed that the internal stress present in the anodic oxide films was compressive stress, and that the stress was larger with ECAP than without. The compressive internal stress gradually decreased with increasing annealing temperature. Scanning electron microscopy showed that cracks occurred in the anodic oxide film on Al-Mg alloy during initial corrosion and that the cracks were larger with ECAP than without. The ECAP process of severe plastic deformation produces large internal stresses in the Al-Mg alloy; the stresses remain in the anodic oxide films, increasingthe likelihood of cracks. It is assumed that the pitting corrosion is promoted by these cracks as a result of the higher internal stress resulting from ECAP. The improvement in the pitting corrosion resistance of anodized AlMg alloy as a result of annealing appears to be attributable to a decrease in the internal stresses in anodic oxide films

CAPACITY ANALYSIS OF THE SILVER OXIDE-ZINC CELL (PHASE 1)

  • 이완구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.14 no.4
    • /
    • pp.15-25
    • /
    • 1981
  • Electrical behaviors of the divalent silver oxide-zinc cell were analyzed for imporving capacity and keeping electrodes from passivation or sharp increases of cell internal resistance in the course of discharge. One of primary factors in relation to lowering performance can be depicted by cell internal resistance increase being created by various routes, first by insufficiency and/or the carbonation of the electrolyte, secondly by barrier blockage, thirdly by electrode passivation which are due to improper material use of wrong processing, and by gassing as fourth cause. The carbonation causes electrobyte to have impedance up as well as poor amalgamation, resulting in vigorous corrosion reaction of copper plated inner top, evolving hydrogen gas. Electrical characteristics of the cell was reviewed to elucidate relationships between the discharge capacity and the cell internal resistance.

  • PDF

A Study on Degradation Diagnosis of Secondary Battery (산업용 이차전지의 열화판정에 관한 연구)

  • Nam, Jong-Ha;Tae, Yong-Jun;Yeo, In-Young;Choi, Jin-Hong;Cheon, Chang-Yeol;Kim, Jae-Woong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.170-172
    • /
    • 2005
  • Internal battery ohmic measurements have been a hot topic amongst battery users and battery manufacturers. As a battery deteriorates and loses its capacity, the internal resistance of the battery increases. Everyone seems to agree that measuring the internal parameters of a cell can be very useful in determining a battery's state of health. In this paper experiences show that if a cell's resistance increases by more than25% above its baseline value(known good resistance of new 100% capacity cell), the cell will no loger be able to deliver 80% or more of the rated capacity.

  • PDF

Reference Values of Transcranial Doppler Ultrasonography Measurement and Relation with Change Factor (Transcranial Doppler Ultrasonography(TCD)의 참고치와 변화 요인들과의 연관성)

  • Jung, Jong-An;Cho, Gook-Ryung;Kim, Nam-Uk;Kang, Chul-Sik;Jeon, Sang-Yun;Hong, Seok
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.709-716
    • /
    • 2007
  • Objective : We present reference values of flow velocities of intracranial and extracranial cerebral arteries and relation with change factor. Method : We checked transcranial Doppler ultrasonography on mean velocity, systolic velocity, pulsatility index, and resistance index of 252 patients. We also compared differences of change factor. Result : The result showed a difference by sex and age and relevance between vessels besides mean velocity of vessels related with past history and social history. Conclusion : According to the above results, females showed higher velocity of all vessels. With advancing age, subjects showed reduction in velocity and increase in pulsatility index and resistance index. Anterior cerebral, middle cerebral, and posterior cerebral artery increased in proportion to velocity of internal carotid artery and basilar artery. Vessel velocity correlated with diabetes mellitus, hypertension and hyperlipidemia.

  • PDF

Evaluation of Compressive Strength and Freeze-thaw Resistance Properties of Concrete using Superabsorbent Polymer (고 흡수성 폴리머를 혼입한 콘크리트의 압축 강도 및 동결융해 저항성 평가)

  • Kim, Il-Sun;Choi, So-Yeong;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.86-94
    • /
    • 2020
  • When the Superabsorbent Polymer (SAP) is added into concrete, the slump decreases rapidly, deteriorating the workability, the internal curing effect can be obtained through the water absorption and discharge process, and the internal voids of the concrete are increased. In this study, the effects of internal curing and voids were evaluated by evaluating the compressive strength, freeze-thaw resistance, and chloride penetration resistance of SAP-adding concrete that secured workability using a water reducing agent. Also, the internal curing effect of SAP was evaluated by dividing the curing conditions of concrete into water curing and sealed curing. From the result, as the SAP adding ratio increased, the amount of water reducing agent increased, and as for the compressive strength, the SAP adding ratio of 1.5% showed the greatest compressive strength. In particular, in the case of sealed curing showed higher compressive strength than the water curing. It is considered that the compressive strength increased due to the reduction of the effective water-cement ratio and the internal curing effect. Adding 1.0~1.5% of SAP improved the freeze-thaw resistance similar to the case of adding the AE agent, and the addition of more than 1.0% of SAP improved the chloride penetration resistance. The optimal adding ratio of SAP is 1.5%, and the adding ratio of 2.0% or more adversely affects the compressive strength and freeze-thaw resistance.

The Application of Impulse Oscillometry(IOS) in the Detection of Smoking Induced Early Airway Obstruction (Impulse Oscillometry(IOS)를 이용한 흡연자에서의 조기 기도폐쇄의 연구)

  • Kim, Youn-Seup;Kweon, Suk-Hoe;Song, Mi-Young;Yoo, Sun-Mi;Park, Jae-Seuk;Jee, Young-Koo;Lee, Kye-Young;Kim, Keun-Youl
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1030-1039
    • /
    • 1997
  • Background : Impulse Oscillometry is a noninvasive and effort-independent test used to characterize the mechanical impedance of the respiratory system. The clinical potential of the IOS is rapid and demands only passive cooperation which makes it especially appealing for children, for epidemiologic surveys and for conditions in which quiet breathig instead of forced expiratory maneuvers are preferred. However, several studies have shown conflicting results that the role of IOS about detection of smoking induced small airway diseases or early airway obstruction Methods : Study was to evaluate the clinical ability of the IOS to detect about smoking induced early airway obstruction in persons with normal spirometry test. Respiratory asymptomatic study groups were formed that one is non-smoking group, another is smoking group. Results : The parameters of spirometry were not significantly differences between non-smoking group and smoking group. Among the parameters of IOS, total resistance(non-smoking group : smoking group=$2.22{\pm}1.20$ : $2.58{\pm}1.71$), peripheral resistance($1.25{\pm}0.62$ : $1.47{\pm}0.10$), bronchial compliance($0.44{\pm}0.12$ : $0.47{\pm}0.16$) were not statistically significant different (p<0.05), but central resistance and lung compliance were not statistically significant different (unit ; resistance=hPa/l/s, compliance=l/hPa). Resistance(Rrs) was not statistically significant different with changes of frequences(5, 10, 15, 20, 25, 30, 35Hz), but Reactance(Xrs) was statistically significant different with low frequences that X5(non-smoking group : smoking group=$-0.62{\pm}0.28$ : $-0.76{\pm}0.48$, p<0.001) and X10($-0.06{\pm}0.19$ : $-0.15{\pm}0.33$, p<0.013) (unit; hPall/s, $hPa{\cong}cmH_2O$). Conclusion : Impulse oocillometer(IOS) is clinically available method to detect about smoking induced early airway obstruction. And clinically potential parameters of IOS were considers that total resistance, peripheral resistance, bronchial resistance, and reactance of low frequency at 5Hz, 10Hz.

  • PDF

A surface resistance effect on the fabrication of Dye-sensitized Solar Cell with various widths (셀 폭에 따른 염료 감응형 태양전지의 표면저항 효과)

  • Choi, Jin-Young;Kim, Yong-Cheol;Park, Sung-Jun;Sung, Youl-Moon;Kim, Whi-Young;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.187-191
    • /
    • 2006
  • Sputter deposition followed by surface treatment was studied using reactive RF plasma as a method for preparing titanium oxide $(TiO_2)$ films on the FTO $(SnO_2: F)$ substrate for dye-sensitized solar cells (DSCs). Anatase structure $TiO_2$ films deposited by reactive RF magnetron sputtering under the conditions of $Ar/O_2(5%)$ mixtures, RF power of 600W and substrate temperature of $400^{\circ}C$ were surface-treated by inductive coupled plasma (ICP) with $Ar/O_2$ mixtures at substrate temperature of $400^{\circ}C$, and thus the films were applied to the DSCs. We have chosen a solar cell width as a variable of a large-scaled DSCs and confirmed electric characteristics of an individual cell. As a result, the higher the internal resistance of DSC becomes, the wider the width gets. Internal resistance makes it difficult to collect photoelectron generated from dye. Ultimately up sizing DSC causes the increase of internal resistance and then has a bad effect on the cell characteristics.

  • PDF