• Title/Summary/Keyword: internal illumination

Search Result 60, Processing Time 0.029 seconds

Realtime Object Extraction and Tracking System for Moving Object Monitoring (이동 객체 감시를 위한 실시간 객체추출 및 추적시스템)

  • Kang Hyun-Joong;Lee Hwang-hyoung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.2 s.34
    • /
    • pp.59-68
    • /
    • 2005
  • Object tracking in a real time image is one of interesting subjects in computer vision and many practical application fields Past couple of years. But sometimes existing systems cannot find object by recognize background noise as object. This paper proposes a method of object detection and tracking using adaptive background image in real time. To detect object which does not influenced by illumination and remove noise in background image, this system generates adaptive background image by real time background image updating. This system detects object using the difference between background image and input image from camera. After setting up MBR(minimum bounding rectangle) using the internal point of detected otject, the system tracks otiect through this MBR. In addition, this paper evaluates the test result about performance of proposed method as compared with existing tracking algorithm.

  • PDF

Electrical and Optical Characteristics of Inductively Coupled Plasma by Ar Gas Pressure and Rf Power (Ar 가스 압력과 RF 전력에 따른 유도결합형 플라즈마의 전기적 및 광학적 특성)

  • 최용성;허인성;이영환;박대희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.560-566
    • /
    • 2004
  • In this paper, the electrical and emission properties of electrodeless fluorescent lamp were discussed using the inductively coupled plasma (ICP) with the variation of argon gas pressure and RF power. The RF output was applied to the antenna in the range of 5∼50 W at 13.56 MHz. The internal plasma voltage of the chamber and the probe current were measured while varying the supply voltage to the Langmuir probe in the range of -100V∼+100V. When the pressure of argon gas was increased, electric current was decreased. There was a significant electric current increase from 10 to 30 W. Also, when the RF power was increased, electron density was increased. Also, the emission spectrum, Ar- I lins, luminance were investigated. At this time, the input parameter for ICP RF plasma, Ar gas pressure and RF power were applied in the range of 10∼60 mTorr, 10∼300 W, respectively. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.

Endodontic management of mandibular first premolar with C-shaped canals by using cone-beam computed tomography and dental operating microscope (CBCT와 치과용 현미경을 이용한 C형 근관을 가지는 하악 제1소구치의 근관치료)

  • Chang, Hoon-Sang;Kim, Min-Jeong;Lee, Seok-Ryun;Hong, Sung-Ok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.324-328
    • /
    • 2014
  • Aberrant anatomy of mandibular premolars is very rare in Korean, but aberration can contribute the endodontic failure as it makes difficult to remove the irritants during cleaning and shaping procedure. This case report describes the successful root canal treatment of a rare mandibular first premolar with C-shaped root canal as using a cone-beam computed tomography to understand the internal shape of root canal system and a dental operating microscope to improve the magnification and illumination.

Development of alcohol gas sensors measurable at room temperature (상온에서 측정 가능한 음주 측정용 알코올 가스 센서)

  • Jeon, Byung-Hyun;Lee, Ju-Hyuk;Kim, Seong-Jean;Lee, Cheol-Jin;Choi, Bok-Gil
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3265-3267
    • /
    • 1999
  • Capacitance-type alcohol gas sensors using porous silicon (PS) layer as sensitive film were fabricated to measure low alcohol gas concentration. Though sensors using porous silicon layer have show high sensitivity by large internal surface area, there is still much room for improvement to measure low breath alcohol concentration especially at room temperature. In this work, to discuss the response properties against exposure to organic vapor for breath alcohol measurements on the basis of experimental results. we measured the variation of the capacitance for the range of 0 to 0.5% alcohol concentration, and observed the improvement of sensitivity by illumination of UV light. In addition, the effect of CO2 and N2 gases involved commonly in exhaling breath was estimated, and the same procedure against methanol vapor was executed to compare qualitatively with the capacitance characteristics by alcohol vapor.

  • PDF

Measurement of Inductively Coupled Plasma Using Langmuir Probe (Langmuir Probe를 이용한 유도결합형 플라즈마의 측정)

  • Lee, Y.H.;Jo, J.U.;Kim, K.S.;Choi, Y.S.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1719-1721
    • /
    • 2003
  • In this paper, electrical characteristics of inductively coupled plasma in an electrodeless fluorescent lamp were investigated using a Langmuir probe with a variation of Ar gas pressure. The RF output was applied in the range of 5-50W at 13.56MHz. The internal plasma voltage of the chamber and the probe current were measured while varying the supply voltage to the Langmuir probe in the range of -100V ${\sim}$ +100V. When the pressure of Ar gas was increased, electric current was decreased. There was a significant electric current increase when the applied RF power was increased from 10 W to 30 W. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.

  • PDF

A Development of Video Tracking System on Real Time Using MBR (MBR을 이용한 실시간 영상추적 시스템 개발)

  • Kim, Hee-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1243-1248
    • /
    • 2006
  • Object tracking in a real time image is one of interesting subjects in computer vision and many practical application fields past couple of years. But sometimes existing systems cannot find object by recognize background noise as object. This paper proposes a method of object detection and tracking using adaptive background image in real time. To detect object which does not influenced by illumination and remove noise in background image, this system generates adaptive background image by real time background image updating. This system detects object using the difference between background image and input image from camera. After setting up MBR(minimum bounding rectangle) using the internal point of detected object, the system tracks object through this MBR. In addition, this paper evaluates the test result about performance of proposed method as compared with existing tracking algorithm.

  • PDF

Analyses of the Output Characteristics and the Internal Impedance of Dye-sensitized Solar Cell According to the Fabrication of the Blocking Layer (Blocking layer 제작에 따른 염료감응형 태양전지 출력특성 및 내부 임피던스 분석)

  • Kim, Jin-Kyoung;Son, Min-Kyu;Kim, Soo-Kyoung;Hong, Na-Yeong;Kim, Byung-Man;Prabarkar, Prabarkar;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.85-88
    • /
    • 2012
  • DSCs are based on a dye-adsorbed porous $TiO_2$ layer as a photo electrode [1]. Under the illumination, dye molecules are excited and electrons are produced. The injected electrons in the conduction band of $TiO_2$ may recombine with the electrolyte. To obtain high performance DSCs, it is essential to retard the recombination. The charge recombination can be reduced by forming core-shell structure. In this work, we investigated the core-shell structure with $Al_2O_3$ and MgO coating layer on the porous $TiO_2$ layer. We confirmed the photovoltaic properties by I-V characteristics. The current and the efficiency was improved. In addition to, Through decrease in the width of EIS arc, which is the sum of the interfacial charge transfer resistances of both electrodes, we can be indicated that the block effect.

Enhancement of light extraction efficiency in vertical light-emitting diodes with MgO nano-pyramids structure

  • Son, Jun-Ho;Yu, Hak-Ki;Lee, Jong-Lam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03a
    • /
    • pp.16-16
    • /
    • 2010
  • GaN-based light-emitting diodes (LEDs) are attracting great interest as candidates for next-generation solid-state lighting, because of their long lifetime, small size, high efficacy, and low energy consumption. However, for general illumination applications, the external quantum efficiency of LEDs, determined by the internal quantum efficiency (IQE) and the light extraction efficiency, must be further increased. The IQE is determined by crystal quality and epitaxial layer structure and high value of IQE more than 70% for blue LEDs have been already reported. However, there is much room for improvement of light extraction efficiency because most of the generated photons from active layer remain inside LEDs by total internal reflection at the interface of semiconductor with air due to the high refractive index difference between LEDs epilayer (for GaN, n=2.5) and air (n=1). The light confining in LEDs will be reabsorbed by the metal electrode or active layer, reducing the efficacy of LEDs. Here, we present the first demonstration of enhanced light extraction by forming a MgO nano-pyramids structure on the surface of vertical-LEDs. The MgO nano-pyramids structure was successfully fabricated at room temperature using conventional electron-beam evaporation without any additional process. The nano-sized pyramids of MgO are formed on the surface during growth due to anisotropic characteristics between (111) and (200) plane of MgO. The ZnO layer with quarter-wavelength in thickness is inserted between GaN and MgO layers to increase the critical angle for total internal reflection, because the refractive index of ZnO (n=1.94) could be matched between GaN (n=2.5) and MgO (n=1.73). The MgO nano-pyramids structure and ZnO refractive-index modulation layer enhanced the light extraction efficiency ofV-LEDs with by 49%, comparing with the V-LEDs with a flat n-GaN surface. The angular-dependent emission intensity shows the enhanced light extraction through the side walls of V-LEDs as well as through the top surface of the n-GaN, because of the increase in critical angle for total internal reflection as well as light scattering at the MgO nano-pyramids surface.

  • PDF

Enhancement in the photocurrent of ZnO nanoparticles by thermal annealing

  • Byun, Kwang-Sub;Cho, Kyuong-Ah;Jun, Jin-Hyung;Seong, Ho-Jun;Kim, Sang-Sig
    • Journal of IKEEE
    • /
    • v.13 no.1
    • /
    • pp.57-64
    • /
    • 2009
  • The optoelectrical characteristics of the ZnO nanoparticles (NPs) annealed in vacuum or oxygen condition from $200^{\circ}C$ to $600^{\circ}C$ were examined. Increased on-off ratio (or, the ratio of photocurrent to dark current) was observed when they were annealed at $300^{\circ}C$, $400^{\circ}C$ and $500^{\circ}C$ with the values enhanced about 4 orders compared to the as-prepared ZnO NPs in both annealing conditions, while the maximum efficiency was shown at the annealing temperature of $600^{\circ}C$ for the ZnO NPs annealed in vacuum with the value of 29.8 mA/W and at the temperature of $500^{\circ}C$ for those annealed in oxygen condition with the value of 40.3 mA/W. Photoresponse behavior of the ZnO NPs annealed in oxygen showed the sharp increase right after the ir exposure to the light followed by the slow decay and saturation during steady illumination, differing from the ZnO NPs annealed in vacuum which only exhibited the gradual increase. This difference occurred due to the curing effect of the oxygen vacancies. SEM images indicated no change in their morphologies with annealing, indicating the change in their internal structures by annealing, and most remarkably at $600^{\circ}C$. As for their photoluminescence(PL) spectra, the decrease of the deep-level(DL) emission was observed when they were annealed in oxygen at $400^{\circ}C$, and not at $200^{\circ}C$ and $600^{\circ}C$.

  • PDF

Web-based Video Monitoring System on Real Time using Object Extraction and Tracking out (객체 추출 및 추적을 이용한 실시간 웹기반 영상감시 시스템)

  • 박재표;이광형;이종희;전문석
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.4
    • /
    • pp.85-94
    • /
    • 2004
  • Object tracking in a real time image is one of interesting subjects in computer vision and many Practical application fields during the past couple of years. But sometimes existing systems cannot find all objects by recognizing background noise as object. This paper proposes a method of object detection and tracking using adaptive background image in real time. To detect object which is not influenced by illumination and to remove noise in background image, this system generates adaptive background image by real time background image updating. This system detects object using the difference between background image and input image from camera. After setting up Minimum Bounding Rectangle(MBR) using the internal point of detected object, the system tracks object through this MBR In addition, this paper evaluates the test result about performance of proposed method as compared with existing tracking algorithm.