• Title/Summary/Keyword: internal heat distribution

Search Result 165, Processing Time 0.023 seconds

Three-dimensional thermal-hydraulics/neutronics coupling analysis on the full-scale module of helium-cooled tritium-breeding blanket

  • Qiang Lian;Simiao Tang;Longxiang Zhu;Luteng Zhang;Wan Sun;Shanshan Bu;Liangming Pan;Wenxi Tian;Suizheng Qiu;G.H. Su;Xinghua Wu;Xiaoyu Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4274-4281
    • /
    • 2023
  • Blanket is of vital importance for engineering application of the fusion reactor. Nuclear heat deposition in materials is the main heat source in blanket structure. In this paper, the three-dimensional method for thermal-hydraulics/neutronics coupling analysis is developed and applied for the full-scale module of the helium-cooled ceramic breeder tritium breeding blanket (HCCB TBB) designed for China Fusion Engineering Test Reactor (CFETR). The explicit coupling scheme is used to support data transfer for coupling analysis based on cell-to-cell mapping method. The coupling algorithm is realized by the user-defined function compiled in Fluent. The three-dimensional model is established, and then the coupling analysis is performed using the paralleled Coupling Analysis of Thermal-hydraulics and Neutronics Interface Code (CATNIC). The results reveal the relatively small influence of the coupling analysis compared to the traditional method using the radial fitting function of internal heat source. However, the coupling analysis method is quite important considering the nonuniform distribution of the neutron wall loading (NWL) along the poloidal direction. Finally, the structure optimization of the blanket is carried out using the coupling method to satisfy the thermal requirement of all materials. The nonlinear effect between thermal-hydraulics and neutronics is found during the blanket structure optimization, and the tritium production performance is slightly reduced after optimization. Such an adverse effect should be thoroughly evaluated in the future work.

Study on Judgment of Body Form and Settle Energy Flow before Diagnose the Patients (환자를 살피기 전에 보아야 하는 "입형정기(立形定氣)"에 대한 고찰)

  • Ko, Heung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.5
    • /
    • pp.509-519
    • /
    • 2013
  • Through the study on judgment of Body form and settle Energy flow(立形定氣) before diagnose the patients, the results are as follows. The observation of the body form is to determine prosperity and deficiency of each internal organ. It is necessary to distinguish Body form loss(形脫) and Body form fullness(形充). Fat man(肥人), Thin man(瘦人), Creamy man(膏人), Muscular man(肉人), Small Fat man(脂人) are discriminated by fat distribution, fat content, and muscle mass. The observation of the body form means the observation of structure disorder, color change, develop part at body, head and face. The observation of the body form that is to determine prosperity and deficiency of each internal organ is from the limited knowledge of the anatomy. The observation of face color is considered by blood perfusion, blood oxygenation and accumulation of carotinoid, bilirubin and change of melanin in the facial skin. The prosperity and the deficiency of energy flow is considered by symptom combined with growth (<40 years) and aging (>40 years). The prosperity of energy flow includes the anger, anxious emotion and the deficiency of energy flow includes the fear, depressive emotion. The breathing type is expiratory exhalation like asthma patients in the prosperity of energy flow. The deficiency of energy flow is weakness to overcome the disease. The prosperity and the deficiency of energy flow are considered by body metabolic ratios (Basal metabolic Rate: BMR, Resting metabolic rate: RMR, Physical activity ratios: PASs). Development of subcutaneous fat is good in the person of prosperous energy flow. The person of prosperous energy flow is hard to overcome to heat weather than cold weather. The person of deficiency of energy flow has tendencies of low blood pressure, insufficiency of blood flow in the peripheral and being shocked. The person of deficiency of energy flow has tendencies of chronic fatigue syndrome or automatic nerve disorder. If the patient who has deficiency of energy flow has severe weight loss should be checked for the presence of disease. The observation of small and large of bone is to check the development and disorder of bone growth and aging. The observation of thickness and weakness of muscle is to check the development of muscle, particularly biceps, gastrocnemius, and rectus abdominal muscle. The observation of thickness and weakness of skin is to check the ability of regulating body temperature by sweating.

Experimental Study on Coefficient of Flow Convection (유수대류계수에 관한 실험적 연구)

  • Jeon, Sang-Eun;Kim, Kook-Han;Kim, Jin-Keun;Yang, Joo-Kyoung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.314-322
    • /
    • 2003
  • Pipe cooling method is widely used for reduction of hydration heat and control of cracking in mass concrete structures. However, in order to effectively apply pipe cooling systems to concrete structures, the coefficient of flow convection relating the thermal transfer between inner stream of pipe and concrete must be estimated. In this study, a device measuring the coefficient of flow convection was developed. Since a variation of thermal distribution caused by pipe cooling has a direct effect on internal forced flows, the developed testing device is based on the internal forced flow concept. Influencing factors on the coefficient of flow convection are mainly flow velocity, pipe diameter and thickness, and pipe material. Using experimental results from the developed device, the coefficient of flow convection was calculated. Finally, a general prediction model was proposed by theoretical procedures. The proposed prediction model is able to estimate the coefficient of flow convection with flow velocity and material properties of pipe. From comparison with experimental results, the coefficient of flow convection by this model was well agreed with those by experimental results.

The Drying Characteristics of Apples at Various Drying Conditions (사과의 건조조건(乾燥條件)에 따른 건조특성(乾燥特性))

  • Jung, Shin-Kyo;Choi, Yong-Hee;Shon, Tae-Hwa;Choi, Jong-Uck
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.61-65
    • /
    • 1986
  • This study was performed to examine the drying characteristics of apples at various drying conditions. Air velocity has no effect on the drying rate except the constant rate period. In this experiment the diffusion coefficients of moisture in the apple tissue were in the range of $1.1470-2.2148{\times}10cm^2/sec$. As a result of balance of heat and mass transfer during the falling rate period. an empirical equation based on Fick's law was obtained as follows; $log{\Delta}t\;=\;log\;t_o\;-\;D{\frac{{\pi}^2{\theta}}{4d.}}$ This equation can be used to calculate the temperature of apples during the falling rate period, provided the diffusion coefficients of apple are known. The experimental values of the internal moisture distribution during apple dehydration were nearly in accord with the theoretical values.

  • PDF

Cooling Performance of a Counterflow Regenerative Evaporative Cooler with Finned Channels (대향류 핀삽입형 재생증발식 냉방기의 냉방성능)

  • Moon, Hyun-Ki;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.462-469
    • /
    • 2008
  • A regenerative evaporative cooler has been fabricated and tested for the evaluation of cooling performance. The regenerative evaporative cooler is a kind of indirect evaporative cooler comprised of multiple pairs of dry and wet channels. The air flowing through the dry channels is cooled without any change in the humidity and at the outlet of the dry channel a part of air is redirected to the wet channel where the evaporative cooling takes place. The regenerative evaporative cooler fabricated in this study consists of the multiple pairs of finned channels in counterflow arrangement. The fins and heat transfer plates were made of aluminum and brazed for good thermal connection. Thin porous layer coating was applied to the internal surface of the wet channel to improve surface wettability. The regenerative evaporative cooler was placed in a climate chamber and tested at various operation condition. The cooling performance is found greatly influenced by the evaporation water flow rate. To improve the cooling performance, the evaporation water flow rate needs to be minimized as far as the even distribution of the evaporation water is secured. At the inlet condition of $32^{\circ}C$ and 50%RH, the outlet temperature was measured at $22^{\circ}C$ which is well below the inlet wet-bulb temperature of $23.7^{\circ}C$.

A Study on the Combustion Characteristics of the Small Scale Cyclone Incinerate System for Sludge (슬러지용 소형 사이클론 소각 시스템의 연소특성에 대한 연구)

  • Park, Woo-Cheul;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The performance of the small scale cyclone incinerate system (100kg/hr) to process the sewage sludge containing high moisture is evaluated. The incinerate system design is based on properties of the domestic sewage sludge. The combustion characteristics of the incinerate system is tested and analyzed with the various operation conditions of the moisture level, the sludge feed rate and the auxiliary fuel feed rate. The pressure loss of the whole system is appeared relatively small of 700mmAq under the normal operating condition and the temperature distribution of the incinerator internal combustion is maintained less than 1000C. Auxiliary fuel of 4.7 1/hr is required to incinerate 100kg sludge which include 87% moisture. Because the inside temperature of the incinerator is maintained less than $1000^{\circ}C$, it is predicted that the most NOx measured is produced not from the heat during the combustion process but from the oxidation of the N ingredient in the sludge. From the component analysis of ash, the organic matter is not entirely detected. Accordingly, it is estimated that the complete combustion has been accomplished in the incinerator.

  • PDF

Study on The Heat Transfer and Mechanical Modeling of Fiber-Mixed High Strength Concrete (섬유혼입 고강도 콘크리트의 열전달 및 역학적 거동 해석모델에 대한 연구)

  • Shin, Young-Sub;Han, Tong-Seok;Youm, Kwang-Soo;Jeon, Hyun-Kyu
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.45-52
    • /
    • 2011
  • To improve fire-resistance of a high strength concrete against spalling under elevated temperature, fibers can be mixed to provide flow paths of evaporated water to the surface of concrete when heated. In this study, the experiment of a column under fire and mechanical loads is conducted and the material model for predicting temperature of reinforcement steel bar and mechanical behavior of fiber-mixed high strength concrete is suggested. The material model in previous studies is modified by incorporating physical behavior of internal concrete and thermal characteristics of concrete at the elevated temperature. Thermo-mechanical analysis of the fiber-mixed high strength concrete column is conducted using the calibrated material model. The performance of the proposed material model is confirmed by comparing thermo-mechanical analysis results with the experiment of a column under fire and mechanical loads.

Design of Busbar Joint Condition Monitoring System (부스바 접촉부 체결상태 모니터링 시스템 설계)

  • Jeong, Sung-Hak;Lee, Young-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.823-824
    • /
    • 2016
  • In general, distribution board, panel board and motor control center can be installed over a wide area such as residence of group, building, schools, factories, ports, airports, water service and sewerage, substation and heavy industries that are used to supply converts the voltages extra high voltage into optimal voltage. There are electrical accidents due to rise of contact temperature, loose contact of bus bar, deterioration of the contact resistance, overtemperatue of the bus bars. In this paper, we propose bus bar joints monitoring system with loose connection of bus bar, measuring the joint resistance of busbars and monitoring internal and external heat. The proposed system can be reduced the electrical accidents by maintenance of busbar joints and the temperature of the conductive contact surface of busbars.

  • PDF

The Causes of Guilt in Ready-meal Users: A Focus on Cooking Instructions and Consumers' Health Locus of Control

  • Shin, Hyunsook;Lee, Dongmin;Lim, Jeeyoung;Moon, Junghoon
    • Asia Marketing Journal
    • /
    • v.21 no.4
    • /
    • pp.25-43
    • /
    • 2020
  • Although ready meals have recently increased their market share in the Korean food industry, a literature review found that the use of ready meals triggers feelings of guilt in homemakers. Such guilt arises as a result of several factors apparently related to consumers' health. Consequently, levels of guilt might be expected to vary depending on consumers' perceived health locus. The present study aims to examine (a) how health locus affects guilty feelings about ready-meal consumption, (b) how the effect varies in relation to the consumption of different types of ready meal, and (c) the relationship between consumers' guilty feelings and willingness to buy ready meals. Three dimensions of health locus of control (HLC) -internal HLC (IHLC), powerful-others HLC (PHLC), and chance HLC (CHLC)- were presumed to influence consumers' feelings of guilt in association with ready meals. Data were collected via an online survey, and participants were randomly assigned to either of two groups: one group was instructed to heat meals in a microwave (ready-to-heat [RTH] group, n=104) and the other cooked using a pan with additional ingredients (ready-to-cook [RTC] group, n=101). The study found that guilty feelings about consuming RTH meals increased in line with increased external HLCs, namely, PHLC and CHLC. For the RTC group, guilt increased in line with increased PHLC. IHLC had no significant effect on guilty feelings in either group. Willingness to buy ready meals decreased for both groups as consumers' feelings of guilt increased. Even RTC meals, which require more time and energy in food preparation, did not reduce guilty feelings among consumers with higher PHLC. RTC meals are preferable for consumers with higher CHLC, since their sense of greater involvement in the cooking process alleviates their feelings of guilt. Cooking with already prepared and uncooked ingredients brought fun and joy, both for the participants and their significant others. This interpretation may be developed into a strategic plan by ready-meal producers to strengthen their marketing strategy.

Study on the Relationship among Bi-Su Type, Obesity Index, and Pattern Identification in Stroke Patients (중풍 환자에서 비수, 비만지표, 변증간 연관성에 대한 고찰)

  • Kim, So-Yeon;Lee, Jung-Sup;Kang, Byoung-Kab;Ko, Mi-Mi;Kim, Jeong-Cheol;Oh, Dal-Seok;Bang, Ok-Sun
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.550-557
    • /
    • 2009
  • Objectives : The purpose of this study was to investigate the possibility of Bi-Su as a pattern identification (PI) index in stroke patients. Methods : The subjects were 424 hospitalized stroke patients within 1 month from onset and diagnosed with the same PI subtypes (dampness & phlegm, qi deficiency, fire & heat, eum deficiency, and blood stasis) by agreement of two clinical experts. Bi-Su type is a kind of body shape (Bi : fat, Su : lean). Bi-Su type and degree (Bi-Su score) were decided by clinical expert. Body mass index (BMI) and waist-hip ratio (WHR) were used as an obesity index. Correlation analysis between Bi-Su score and obesity index (Spearman) and variance analysis for Bi-Su score, BMI, and WHR among PI subtypes (ANOVA) and sex were carried out. Results : While there was partial correlation between Bi-Su type and BMI($r^2$=0.634, p<0.001), the distribution of the BMI group based on the Bi-Su group showed the broadest range. The Bi-Su score in the dampness & phlegm group was higher than in the other groups (p<0.001). BMI in the dampness & phlegm groups was also higher but the BMI differences among PI subtypes was low (p=0.002). The Bi-Su score in the dampness & phlegm group was similar in both sexes, although the hand score in the eum deficiency group was the lowest, especially in males. Conclusions : Although BMI is not an objective enough tool for evaluating Bi-Su type, Bi-Su type is more appropriate than BMI as PI index. Therefore Bi-Su type could be used as one of the PI indices for dampness & phlegm or eum deficiency group in stroke patients.

  • PDF