• Title/Summary/Keyword: internal heat distribution

Search Result 165, Processing Time 0.03 seconds

A numerical study on the vaporization of a droplet considering internal circulating flow in the presence of an oscillating flow (진동하는 유동장하에서 내부 순환 유동을 고려한 액적의 증발에 관한 수치적 연구)

  • Ha, Man-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1700-1716
    • /
    • 1996
  • The two-dimensional, unsteady, laminar conservation equations for mass, momentum, energy and species transport in the gas phase and mass, momentum and energy in the liquid phase are solved simultaneously in spherical coordinates in order to study heating and vaporization of a droplet entrained in the oscillating flow. The numerical solution gives the velocity and temperature distribution in both gas and liquid phase as a function of time. When the gas flow oscillates around an vaporizing droplet, the liquid flow circulates in the clockwise or counterclockwise direction and the temperature distribution in the liquid phase changes its shapes, depending on the gas fow direction. When the gas flow changes its direction of circulating liquid flow is opposite to the gas flow, forming two vortex circulating in the opposite direction. During the heating period, the difference in the maximum and minimum temperature is large, followed by the almost uniform temperature slightly below the boiling temperature. The mass and heat transfer from the droplet depend on the droplet temperature, droplet diameter and the magnitude of relative velocity, giving the droplet lifetime different from the d$^{2}$-law.

Analysis of Thermal Runaway Phenomenon Caused by ZnO Varistor Operation Using Finite Element Method (유한요소법에 의한 ZnO 바리스터 동작 시 발생되는 열폭주 현상 해석)

  • Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.372-376
    • /
    • 2022
  • Since the ZnO varistor is a semiconductor device, the internal thermal distribution during the varistor operation is recognized as an important factor in the performance and deterioration of the varistor. For an optimal varistor structure design, the thermal runaway phenomenon during the varistor operation was interpreted using the Comsol 5.2 analysis program by a finite element analysis. The maximum temperature of the center measured in the cross section of the ZnO varistor was confirmed to increase as the temperature moved from the lower electrode to the center towards the upper electrode up to 572.6 K. The electrodes are thinned so that the influence of the Schottky barrier is not great. The heat gradient balance is determined to be improved when the electrode of the hybrid form is introduced. The thickness, density, pore distribution, impurity uniformity, and particle size of the ZnO varistor are required, and it is determined that the pyrolysis gradient will be improved regardless of the electrode thickness. When these results are applied to design the ZnO varistor, the optimal structure of the ZnO varistor can be obtained.

The Cooling Effect of Pipe Cooling in Mass Concrete Structures (매스 콘크리트 구조물의 파이프 쿨링에 의한 냉각효과)

  • 오병환;신경준;차수원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.299-304
    • /
    • 1999
  • Cracking of concrete is one of the main issues of structural design next to ensuring the load-bearing capacity. Thermal cracking is a recurring concern in the production of concrete structures in particular when large, massive structures are considered. Thremal stresses arise from the differential temperature distribution either within s sturcture or between newly cast sectons and adjoining older parts. There are many different methods of reducing thermal stresses. A method often used for reducing temperature within a structure, is to cool the inner core with embedded cooling pipes. In this study, finite element method is employed for thermal analysis of concrete structures. To calculate water temperature variation in pipe, the conservation of thermal energy in internal flow was adopted. The cooling effect of pipe cooling is studied with several factors like convective coefficient, water temperature, concrete heat characteristics

  • PDF

Temperature Rise Prediction of 145kV 40kA Three-phase GIS Bus Bar (145kV 40kA 3상 GIS 모선의 온도상승 예측)

  • Kim, Joong-Kyoung;Lee, Ji-Yeon;Jung, Sang-Yong;Hahn, Sung-Chin
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.842-843
    • /
    • 2008
  • Many works on the temperature prediction of power apparatus have usually done by coupled magneto-thermal analysis. However, this method can not consider the internal gas or oil flow in the power apparatus. This paper proposes a new coupled magneto-thermal-flow analysis considering Navier-Stokes equations. The convection heat transfer coefficient is calculated analytically and is applied to the boundary condition to the proposed method. Temperature distribution of 145kV 40kA three-phase GIS bus bar model is obtained by coupled magneto-thermal-flow analysis and shows good agreement with the experimental data.

  • PDF

Effect of gravity on a micropolar thermoelastic medium with voids under three-phase-lag model

  • Alharbi, Amnah M.;Othman, Mohamed I.A.;Al-Autabi, Al-Anoud M.Kh.
    • Structural Engineering and Mechanics
    • /
    • v.76 no.5
    • /
    • pp.579-590
    • /
    • 2020
  • This paper's objective is to investigate the effect of gravity on a micropolar thermoelastic medium with voids. The problem is assessed according to the three-phase-lag model. An analysis of the resulting non-dimensional displacement, temperature variation, and internal stress of the study material is carried out and presented graphically. The non-dimensional displacement, temperature, micro-rotation, the change in the volume fraction field and stress of the material are obtained and illustrated graphically. Comparisons are made with the results predicted by different theories for different values of gravity, the phase-lag of the heat flux and the phase-lag of the temperature gradient. The numerical results reveal that gravity and relaxation times have a significant influence on the distribution of the field quantities. Some notable insights of interest are deduced from the investigation.

A literatual study on the Ecthyma (렴瘡에 對한 文獻的 考察)

  • Kim, Hee-Taek;Oh, Young-Seon;Rho, Sek-Seon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.10 no.1
    • /
    • pp.209-246
    • /
    • 1997
  • In the literatual study on the Ecthyma, the results were as follows. 1. The pathogenic factors of Ecthyma is divided three parts. One is exogenous pathogenic factors which including the wind evil, wind heat and toxic material produced by wetness evil. Another is endogenous pathogenic factors which including the declination of kidney-yang, impairment of the liver and kidney, the lower classes of yin-fire, accumulation of wetness-heat in the spleen asthenia, impairment of the liver and kidney, wetness-heat of three yang, asthenic heat-syndrome of three yin. The other is pathogenic factors neither endogenous nor exogenous which including the food and living, uncontrol sexual excess, anxiety and angry, injury of skin, injury of insects and animals. 2. Five viscera which was concerned with Ecthyma are liver, spleen and kidney. 3. Frequent region of Ecthyma are S-36(足三里) and C-7(陰交). External Ecthyma was rose to wetness-heat of three yang channel that cured easily. Internal Ecthyma was rose to asthenic heat-syndrome of three yin channel that cured hardly. 4. In the frequency of prescription, the most numerous prescription is Bojungikgitang(補中益氣湯) and the next are Kyukgigo(隔紙膏) and Yukmijihwanghwan(六味地滉丸). 5. In the frequency of medicine, the most medicine is Calomelas(輕粉) which included Hydrargyrum(水銀) and the next are Olibanum(乳香) and Resina Commiphorae Myrrhae(沒藥) which regulating vital energy and pain control medicine used that in order to destroy insects and remove polson. 6. In classification of the medical action, medicine of clearing away summer-heat and heat evil and activating blood circulation to dissipate blood stasis used to be very busy which in order to remove the disorder of vital energy for virulent heat-evil. 7. In classification of four characters, the most part is warm medicine, the next are cold and cool medicine and there is a few that is hot medicine. 8. In classification of five tastes, the most numerous tastes are bitter and acrid, the next are sweet, salty and sour tastes. 9. In classification of virulence of medicine, the most part is non-toxic, the next are weakly and deadly poison. 10. In classification of channel distribution, the most is the medicine that belongs to liver channel, the next are the lung, spleen, stomach and kidney channel.

  • PDF

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

Early age behavior analysis for reinforced concrete bridge pier

  • Wang, Xianfeng;Li, Dawang;Han, Ningxu;Xing, Feng
    • Computers and Concrete
    • /
    • v.18 no.5
    • /
    • pp.1041-1051
    • /
    • 2016
  • In this study, the construction of a reinforced concrete bridge pier was analyzed from durability point of view. The goal of the study is to analyze the crack iniation condition due to construction and present some recommendations for construction conditions of the reinforced concrete bridge pier. The bridge is located at the western port area of Shenzhen, where the climate is high temperature and humidity. To control the cracking of concrete, a construction simulation was carried out for a heat transfer problem as well as a thermal stress problem. A shrinkage model for heat produced due to cement hydration and a Burger constitutive model to simulate the creep effect are used. The modelling based on Femmasse(C) is verified by comparing with the testing results of a real underground abutment. For the bridge pier, the temperature and stress distribution, as well as their evolution with time are shown. To simulate the construction condition, four initial concrete temperatures ($5^{\circ}C$, $10^{\circ}C$, $15^{\circ}C$, $20^{\circ}C$) and three demoulding time tips (48h, 72h, 96h) are investigated. From the results, it is concluded that a high initial concrete temperature could result in a high extreme internal temperature, which causes the early peak temperature and the larger principle stresses. The demoulding time seems to be less important for the chosen study cases. Currently used 72 hours in the construction practice may be a reasonable choice.

Study on the Pulse Diagnosis for Pattern Identifications in Stroke Patients (중풍환자의 변증에 따른 맥상의 분포)

  • Lee, Jung-Sup;Kang, Byoung-Kab;Ko, Mi-Mi;Kim, Bo-Young;Kim, Jeong-Cheol;Lee, In;Kim, Yun-Sik;Cho, Ki-Ho;Choi, Sun-Mi;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1378-1382
    • /
    • 2008
  • This study is aim to evaluate pulse diagnosis as indicators for classification of the pattern identifications in stroke patients. To get the clinical information, we recruited the onset 1 month stroke patients through the multicenter network which consists of 13 oriental hospitals. The clinical informations about three pairs of pulse wave form and levels of their significancy based on the case report form (CRF) were collected and their distribution in each pattern identification were analyzed. The results are as follows Fire-Heat group shows high portions of floating pulse, rapid pulse and solid pulse. Qi Defficiency group has a greater portion of deep pulse, slow pulse, deficient pulse. The well-defined character of Phlegm-Retained Fluid, Yin Defficiency, Static Blood groups cannot be explained by pulse wave form. These results show a rough relationship between the pulse diagnosis and pattern identifications of stroke therefore, further studies are required to determine the pulse diagnosis as significant indicators of stroke pattern identification.

An Observational Multi-Center Study Protocol for Distribution of Pattern Identification and Clinical Index in Parkinson's Disease (파킨슨병 변증 유형 및 지표 분포에 대한 전향적 다기관 관찰연구 프로토콜)

  • HuiYan Zhao;Ojin Kwon;Bok-Nam Seo;Seong-Uk Park;Horyong Yoo;Jung-Hee Jang
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • Objectives: This study investigated the pattern identification (PI) and clinical index of Parkinson's disease (PD) for personalized diagnosis and treatment. Methods: This prospective observational multi-center study recruited 100 patients diagnosed with PD from two Korean medicine hospitals. To cluster new subtypes of PD, items on a PI questionnaire (heat and cold, deficiency and excess, visceral PI) were evaluated along with pulse and tongue analysis. Gait analysis was performed and blood and feces molecular signature changes were assessed to explore biomarkers for new subtypes. In addition, unified PD rating scale II and III scores and the European quality of life 5-dimension questionnaire were assessed. Results: The clinical index obtained in this study analyzed the frequency statistics and hierarchical clustering analysis to classify new subtypes based on PI. Moreover, the biomarkers and current status of herbal medicine treatment were analyzed using the new subtypes. The results provide comprehensive data to investigate new subtypes and subtype-based biomarkers for the personalized diagnosis and treatment of PD patients. Ethical approval was obtained from the medical ethics committees of the two Korean medicine hospitals. All amendments to the research protocol were submitted and approved. Conclusions: An objective and standardized diagnostic tool is needed for the personalized treatment of PD by traditional Korean medicine. Therefore, we developed a clinical index as the basis for the PI clinical evaluation of PD. Trial Registration: This trial is registered with the Clinical Research Information Service (CRIS) (KCT0008677)