• 제목/요약/키워드: internal facilities

검색결과 488건 처리시간 0.023초

수.변전설비의 안전실태 조사 및 대책 연구 (A Study on counterplan and safety state research of substation at flood area)

  • 배석명;김한상;김기현;방선배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.47-52
    • /
    • 2005
  • lt's a general tendency that electrical facilities of power station become a large size and increase in number because electrical facilities become big and complicated with internal industrial development and economic growth. So, electrical accidents were increased in this electrical facilities of power station. Therefore, we studied on the safety environment in power station and compared of internal and external standards. So this paper gives information which is applied to install the electrical facilities and Prevents measures against electrical accidents.

  • PDF

학교시설의 장애물 없는 생활환경(BF) 인증기준 자체평가서 분석에 관한 연구 (A Study on the Analysis of Self-Assessment Form based on Certification of Barrier Free in School Facilities)

  • 윤평세;이종국
    • 교육녹색환경연구
    • /
    • 제18권3호
    • /
    • pp.16-27
    • /
    • 2019
  • 본 연구는 장애물 없는 생활환경(BF)인증제도 시행에 따른 학교시설의 BF인증 적용사항에 대한 기본연구로 건축물 BF인증 평가지표를 바탕으로 초등학교 BF 예비인증 자체평가서 분석을 통해 학교시설에 적합한 장애물 없는 생활환경(BF)인증 평가지표의 개선방향을 모색하고자 하였다. 경상권 내 30개교 초등학교를 선정하여 매개시설, 내부시설, 위생시설, 안내시설, 기타시설의 현황과 평가지표를 분석한 결과 학교시설에 반영되는 항목은 배점 기준의 변별력이 다소 미흡하여 배점 기준 등의 개선이 필요한 것을 알 수 있었다. 누구나 이용하기 편리한 학교시설을 위해 중 하위 배점을 획득한 항목에 대해 기준 개선 및 배점 조정으로 질적 향상을 이끌어내야 한다.

Development of a Mobile Robot System for Visual Inspection under Hot Environment

  • Park, Sang-Deok;Lee, Ho-Gil;Kim, Hong-Seok;Son, Woong-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1506-1510
    • /
    • 2004
  • A mobile robot system is developed to inspect the condition of industrial facilities under hot environment. The mobile robot is equipped with internal and external heat insulating material, an internal cooling mechanism, two CCD cameras, wireless communication devices for both the control and image signals, and an embedded controller. The portable controller is equipped with two joysticks for both the mobile robot and the inspection CCD camera, an LCD monitor, and several buttons. The developed mobile robot travels on the internal floor in hot furnaces by operators' joystick operation, captures the images of facilities in the furnaces using a zoom CCD camera, and sends the images to the portable controller through wireless communication. The mobile robot can be operated without any problem under hot environment less than 400$^{\circ}C$ in 30 minutes. This kind of automatic inspection mobile robot can be helpful to prevent significant troubles of industrial facilities without danger of human beings under harmful environment.

  • PDF

학교시설의 장애물 없는 생활환경(Barrier Free) 인증 사례를 통한 정성평가 텍스트마이닝 기법 적용에 관한 기초연구 (A Basic Study on the Application of Text-Maining Method for Qualitative Evaluation through Barrier Free Certification in School Facilities)

  • 윤평세;이종국
    • 교육녹색환경연구
    • /
    • 제19권1호
    • /
    • pp.25-35
    • /
    • 2020
  • BF인증을 도입하여 운영한 이래 2020년 2월까지 총 6,432건의 인증서 발급이 있었고, 그 중 교육연구시설은 건축물 6,237건 중 1,091건(예비인증 754건, 본인증 337건)으로 약 20%의 BF인증을 취득하였다. BF인증 건축물 평가지표 3개 항목 매개시설, 내부시설, 위생시설 중점적으로 정성평가를 실시하고, 그 도출 결과를 Text Mining 분석 통해 주요 키워드를 도출한다. 도출된 결과 매개시설의 경우 접근로에 대한 문제점이 발생되었으며, 내부시설의 계단에 대한 평가사항 중 사용자에 대한 평가지표 마련이 필요하다는 결과를 알 수 있었다. 마지막으로 위생시설의 경우 주민 개발시설에 설치되는 화장실에 대한 개선이 필요한 것을 알 수 있었다. 도출된 결과를 바탕으로 학교시설 BF인증에 필요한 평가지표가 별로도 마련되어야할 것이다.

배터리 'State of Charge' 예측 알고리즘 구현 (Implementation of Battery 'State of Charge' Estimation algorithm)

  • 김용호;김대환
    • 정보통신설비학회논문지
    • /
    • 제10권1호
    • /
    • pp.27-32
    • /
    • 2011
  • These days more electric devices are implemented in car, and more accurate estimation of SoC is required. OCV with current integration and Internal Resistance is essential method of Battery SoC Estimation. In this paper we propose OCV with current integration method and compare with Internal Resistance method. In OCV with current integration method estimation error was less than average 2%, but requires more than 5 minutes to stabilize OCV. If Stop and Running conditions are change frequently, estimation error will increase. In Internal resistance Modeling method, in high SoC state, estimation error was more than 15%, and in low SoC state, estimation error was less than 8%.

  • PDF

Repeat Auditing of Primary Health-care Facilities Against Standards for Occupational Health and Infection Control: A Study of Compliance and Reliability

  • Cloete, Brynt;Yassi, Annalee;Ehrlich, Rodney
    • Safety and Health at Work
    • /
    • 제11권1호
    • /
    • pp.10-18
    • /
    • 2020
  • Background: The elevated risk of occupational infection such as tuberculosis among health workers in many countries raises the question of whether the quality of occupational health and safety (OHS) and infection prevention and control (IPC) can be improved by auditing. The objectives of this study were to measure (1) audited compliance of primary health-care facilities in South Africa with national standards for OHS and IPC, (2) change in compliance at reaudit three years after baseline, and (3) the inter-rater reliability of the audit. Methods: The study analyzed audits of 60 primary health-care facilities in the Western Cape Province of South Africa. Baseline external audits in the time period 2011-2012 were compared with follow-up internal audits in 2014-2015. Audits at 25 facilities that had both internal and external audits conducted in 2014/2015 were used to measure reliability. Results: At baseline, 25% of 60 facilities were "noncompliant" (audit score<50%), 48% "conditionally compliant" (score >50 < 80%), and only 27% "compliant" (score >80%). Overall, there was no significant improvement in compliance three years after baseline. Percentage agreement on specific items between internal and external audits ranged from 28% to 92% and kappa from -0.8 to 0.41 (poor to moderate). Conclusion: Low baseline compliance with OHS-IPC measures and lack of improvement over three years reflect the difficulties of quality improvement in these domains. Low inter-rater reliability of the audit instrument undermines the audit process. Evidence-based investment of effort is required if repeat auditing is to contribute to occupational risk reduction for health workers.

Empirical Study of Information Resource Management (IRM)

  • Ha, Tai-Hyun
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 1997년도 추계학술대회 발표논문집:21세기를 향한 정보통신 기술의 전망
    • /
    • pp.237-257
    • /
    • 1997
  • The great flowing of information has brought a necessity for good management to make the best use of it in the highly competitive information age. The aims of this study are to investigate the main information sources - divided into largely three groups: literature sources, communication and information technology facilities), trying to find problem areas associated with IRM, indicating possible solutions. The result shows that internal information sources were regarded the most important and most frequently used. For the use of foreign materials, the higher the level of position is, the more people use them. With respect to communication methods, internal information sources were thought most important. With the dramatic falling of the price despite enormously increased functions, IT facilities are becoming important sources. However, the study reveals the use of them is quite limited to a few well-known facilities, which indicates that management should pay attention to more efficient use of them and useful training and education methods.

  • PDF

Verification of Harmonization of Dose Assessment Results According to Internal Exposure Scenarios

  • Kim, Bong-Gi;Ha, Wi-Ho;Kwon, Tae-Eun;Lee, Jun-Ho;Jung, Kyu-Hwan
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.143-153
    • /
    • 2018
  • Background: The determination of the amount of radionuclides and internal dose for the worker who may have intake of radionuclides results in a variation due to uncertainty of measurement data and ingestion information. As a result of this, it is possible that for the same internal exposure scenario assessors could make considerably different estimation of internal dose. In order to reduce this difference, internal exposure scenarios for nuclear facilities were developed, and intercomparison were made to determine the harmonization of dose assessment results among the assessors. Materials and Methods: Seven cases on internal exposures incidents that have occurred or may occur were prepared by referring to the intercomparison excercise scenario that NRC and IAEA have carried out. Based on this, 16 nuclear facilities concerned with internal exposure in Korea were asked to evaluate the scenarios. Each result was statistically determined according to the harmonization discrimination criteria developed by IDEAS/IAEA. Results and Discussion: The results were evaluated as having no outliers in all 7 cases. However, the distribution of the results was spread by various causes. They can be divided into two wide categories. The first one is the distribution of the results according to the assumption of the intake factors and the evaluation factors. The second one is distribution due to misapplication of calculation method and factors related to internal exposure. Conclusion: In order to satisfy the harmonization criteria and accuracy of the internal exposure dose evaluation, it is necessary that exact guidelines should be set on low dose, and various intercomparison cases also be needed including high dose exposure as well as the specialized education. The aim of the blind test is to make harmonization evaluation, but it will also contribute to securing the expertise and high quality of dose evaluation data through the discussion among the participants.

부산지역 초등학교의 개방시설 현황분석을 통한 개방시설의 계획방향에 관한 연구 (A Study on the Design Guidelines through Analysis for the Open-Facilities of Elementary Schools in Busan)

  • 박윤금
    • 교육시설
    • /
    • 제16권1호
    • /
    • pp.59-68
    • /
    • 2009
  • In the knowledge-base 21st century, schools are required functions as a place of education for student as well as a place of life-long education for community. Therefore schools are needed to be open and to be multiple. The purpose of this study is to analysis of open-facilities to community of twenty elementary schools in Busan and to suggest a design guideline for open -facilities of school plan at the base of this analysis. The main contents of this study are as follows: 1) Study for general ideals and necessity of opening school facilities to community. 2) Establish the study objects of the opening facilities by existing studies and a questionnaire. 3) Focused on twenty elementary schools in Busan, analysis of the characteristics of opening facilities in terms of the using efficiency, that is, the approachability, the recognition and the territoriality. 4) At the base of 1) 2) 3), results are as follows: $\circ$ In consideration of approachability, the block plan of the open-facilities should be designed at making a circulation system without interruption of the student's educational area. $\circ$ In consideration of recognition, the form and detail of external and internal of the open-facilities should be designed at making distinction with the student's educational area. $\circ$ In consideration of territoriality, the zone of the open-facilities should be designed at composing exclusive hall, staircase and sanitation.

수.변전설비의 안전 환경 설치에 관한 국내외 규정 비교 분석 (Comparison and Analysis of Domestic and Foreign Standard for safety environment installation of power station)

  • 배석명;김한상;방선배;김기현;이건호;김종민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.267-273
    • /
    • 2004
  • 국내산업의 발달 및 경제 성장과 더불어 전력설비의 대용량화 및 다양한 전기설비의 보급으로 인하여 수변전설비도 증가되고 있으며 또한 대형화되어 지고 있는 추세이다. 이러한 수변전설비에서의 안전 및 설비사고도 점차 증가되고 있는 실정이다. 따라서 본 논문에서는 수변전설비의 안전 환경을 연구대상으로 하여 국내외 규정 및 기준에 대하여 비교 분석하여 수변전설비의 설치시 안전 및 설비사고 예방에 적용이 될 수 있도록 하였다.

  • PDF