• Title/Summary/Keyword: internal control method

Search Result 1,204, Processing Time 0.024 seconds

Individual Ortho-rectification of Coast Guard Aerial Images for Oil Spill Monitoring (유출유 모니터링을 위한 해경 항공 영상의 개별정사보정)

  • Oh, Youngon;Bui, An Ngoc;Choi, Kyoungah;Lee, Impyeong
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1479-1488
    • /
    • 2022
  • Accidents in which oil spills occur intermittently in the ocean due to ship collisions and sinkings. In order to prepare prompt countermeasures when such an accident occurs, it is necessary to accurately identify the current status of spilled oil. To this end, the Coast Guard patrols the target area with a fixed-wing airplane or helicopter and checks it with the naked eye or video, but it was difficult to determine the area contaminated by the spilled oil and its exact location on the map. Accordingly, this study develops a technology for direct ortho-rectification by automatically geo-referencing aerial images collected by the Coast Guard without individual ground reference points to identify the current status of spilled oil. First, meta information required for georeferencing is extracted from a visualized screen of sensor information such as video by optical character recognition (OCR). Based on the extracted information, the external orientation parameters of the image are determined. Images are individually orthorectified using the determined the external orientation parameters. The accuracy of individual orthoimages generated through this method was evaluated to be about tens of meters up to 100 m. The accuracy level was reasonably acceptable considering the inherent errors of the position and attitude sensors, the inaccuracies in the internal orientation parameters such as camera focal length, without using no ground control points. It is judged to be an appropriate level for identifying the current status of spilled oil contaminated areas in the sea. In the future, if real-time transmission of images captured during flight becomes possible, individual orthoimages can be generated in real time through the proposed individual orthorectification technology. Based on this, it can be effectively used to quickly identify the current status of spilled oil contamination and establish countermeasures.

A Study on the Calculation of Optimal Compensation Capacity of Reactive Power for Grid Connection of Offshore Wind Farms (해상풍력단지 전력계통 연계를 위한 무효전력 최적 보상용량 계산에 관한 연구)

  • Seong-Min Han;Joo-Hyuk Park;Chang-Hyun Hwang;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.1
    • /
    • pp.65-76
    • /
    • 2024
  • With the recent activation of the offshore wind power industry, there has been a development of power plants with a scale exceeding 400MW, comparable to traditional thermal power plants. Renewable energy, characterized by intermittency depending on the energy source, is a prominent feature of modern renewable power generation facilities, which are structured based on controllable inverter technology. As the integration of renewable energy sources into the grid expands, the grid codes for power system connection are progressively becoming more defined, leading to active discussions and evaluations in this area. In this paper, we propose a method for selecting optimal reactive power compensation capacity when multiple offshore wind farms are integrated and connected through a shared interconnection facility to comply with grid codes. Based on the requirements of the grid code, we analyze the reactive power compensation and excessive stability of the 400MW wind power generation site under development in the southwest sea of Jeonbuk. This analysis involves constructing a generation site database using PSS/E (Power System Simulation for Engineering), incorporating turbine layouts and cable data. The study calculates reactive power due to charging current in internal and external network cables and determines the reactive power compensation capacity at the interconnection point. Additionally, static and dynamic stability assessments are conducted by integrating with the power system database.

Therapeutic Angiogenesis by Intramyocardial Injection of pCK-VEGF165 in Pigs (돼지에서 pCK-VEGF165의 심근내 주입에 의한 치료적 혈관조성)

  • Choi Jae-Sung;Han Woong;Kim Dong Sik;Park Jin Sik;Lee Jong Jin;Lee Dong Soo;Kim Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.323-334
    • /
    • 2005
  • Background: Gene therapy is a new and promising option for the treatment of severe myocardial ischemia by therapeutic angiogenesis. The goal of this study was to elucidate the efficacy of therapeutic angiogenesis by using VEGF165 in large animals. Material and Method: Twenty-one pigs that underwent ligation of the distal left anterior descending coronary artery were randomly allocated to one of two treatments: intramyocardial injection of pCK-VEGF (VEGF) or intramyocardial injection of pCK-Null (Control). Injections were administered 30 days after ligation. Seven pigs died during the trial, but eight pigs from VEGF and six from Control survived. Echo-cardiography was performed on day 0 (preoperative) and on days 30 and 60 following coronary ligation. Gated myocardial single photon emission computed tomography imaging (SPECT) with $^{99m}Tc-labeled$ sestamibi was performed on days 30 and 60. Myocardial perfusion was assessed from the uptake of $^{99m}Tc-labeled$ sestamibi at rest. Global and regional myocardial function as well as post-infarction left ventricular remodeling were assessed from segmental wall thickening; left ventricular ejection fraction (EF); end systolic volume (ESV); and end diastolic volume (EDV) using gated SPECT and echocardiography. Myocardium of the ischemic border zone into which pCK plasmid vector had been injected was also sampled to assess micro-capillary density. Result: Micro-capillary density was significantly higher in the VEGF than in Control ($386\pm110/mm^{2}\;vs.\;291\pm127/mm^{2};\;p<0.001$). Segmental perfusion increased significantly from day 30 to day 60 after intramyocardial injection of plasmid vector in VEGF ($48.4\pm15.2\%\;vs.\;53.8\pm19.6\%;\;p<0.001$), while no significant change was observed in the Control ($45.1\pm17.0\%\;vs.\;43.4\pm17.7\%;\;p=0.186$). This resulted in a significant difference in the percentage changes between the two groups ($11.4\pm27.0\%\;increase\;vs.\;2.7\pm19.0\%\;decrease;\;p=0.003$). Segmental wall thickening increased significantly from day 30 to day 60 in both groups; the increments did not differ between groups. ESV measured using echocardiography increased significantly from day 0 to day 30 in VEGF ($22.9\pm9.9\;mL\;vs.\;32.3\pm9.1\;mL;\; p=0.006$) and in Control ($26.3\pm12.0\;mL\;vs.\;36.8\pm9.7\;mL;\;p=0.046$). EF decreased significantly in VEGF ($52.0\pm7.7\%\;vs.\;46.5\pm7.4\%;\;p=0.004$) and in Control ($48.2\pm9.2\%\;vs.\;41.6\pm10.0\%;\;p=0.028$). There was no significant change in EDV. The interval changes (days $30\~60$) of EF, ESV, and EDV did not differ significantly between groups both by gated SPECT and by echocardiography. Conclusion: Intramyocardial injection of pCK-VEGF165 induced therapeutic angiogenesis and improved myocardial perfusion. However, post-infarction remodeling and global myocardial function were not improved.

Clinical Usefulness of Thyrotropin Binding Inhibitor Immunoglobulin (TBII) Assay by the Comparative Method (측정법에 따른 갑상선자극호르몬 결합억제면역글로블린(TBII)의 임상적 유용성 검토)

  • Park, Hee-Won;Shin, Hee-Jung;Kim, Tae-Hoon;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.175-180
    • /
    • 2009
  • Purpose: Detection of TSH-binding inhibitor immunoglobulin (TBII) in patients with hyperthyroidism is an important result of Graves' disease (GD) and hyperthyroidism treatment. This has been made out an inspection by commercial radio-receptor assays. To increase the sensitivity and the specificity of the assay, many results of the assay were reported. In this study we evaluated the clinical usetulness of TBII assays by the Comparative method. Material and Methods: We were measured by using healthy control group (n=30, male=20, female=10) of Seoul National University Hospital Healthcare System Gangnam Center from January to March in 2009. Similarly, We were measured by using hyperthyroid (TSH<$0.05\;{\mu}IU/mL$, FT4>1.80 ng/dL) experimental group (n=58, male=14, female=44) of division of endocrinology and metabolism department of internal medicine Seoul National University Hospital from January to March in 2009. We made a comparative study of each two assays from the first generation to the third generation. We were used of TSAb assay as a measurement of GD diagnostic technique. Results: The specificity of healthy control group was 100% according to the generation. (Specificity=100%, n=30) The sensitivity of hyperthyroid experimental group were the first generation RSR<%> (79.3%, n=58), RSR (51.7%, n=58), the second generation RSR-CT (93.1%, n=58), BRAHMSCT (98.3%, n=58), the third generation ELISA (94.6%, n=56), ECLIA (97.7%, n=58) and TS-Ab<%> (93.5%, n=46). Conclusion: We were used of TSAb assay as a measurement of GD diagnostic technique, The result of data showed a high correlation between the third generation TBII assay and the second generation TBII assay ($R^2$=0.923). Instead of the first generation assay, the second generation assay can be more useful in clincal diagnosis.

  • PDF

A Study on the Institutional Conditions and Problems for the Transition of North Korean Economic System (북한 경제체제전환을 위한 제도적 조건과 문제점에 관한 연구)

  • Kang, Chae-Yeon;Kwak, In-ok
    • International Area Studies Review
    • /
    • v.22 no.2
    • /
    • pp.163-186
    • /
    • 2018
  • The purpose of this study is to analyze the institutional conditions and problems for the transition to the North Korean economic system. As a research method, we first analyzed the legislative processes of 4th stage market reform policies (liberalization, privatization, privatization, and corporation) by major economic transition countries. And we found out the difference with North Korea. Based on this, it analyzed the process of institutionalization of North Korea's 4th stage economic reform policies (7.1 measures, comprehensive market policies, Currency reform, 6.28 policy). According to research, There are three important conditions that can not compare the changes of the North Korean market economy with those of the transition economies. First, the internal and external conditions and environment for the transition of the economic system and the role of the state and civil society are very different. Second, the means and objectives of the policy decision process and the implementation process are different. Third, it differs absolutely in terms of the nature and effectiveness of the nation's political and economic policies. Fourth, the priority, contents, and legislation process of economic policies for economic reform differ considerably from those of North Korea. Especially, when discussing the possibility of transition to the 'Chinese model', it is accompanied a considerable risk. It is because the purpose of market entry of control power in North Korea and their survival network are quite unique. In addition, China's domestic market size, population size, and type of control are quite different from North Korea. A necessary and sufficient condition for the transition of the North Korean economic system is the relaxation of physical control mechanisms and institutions in the market area. Next, it is necessary to make a legitimate institutionalization as well as an entire survey on the illegal ownership market. Based on this, it is necessary to gradually change the dependence of the domestic market on China to South Korea. In other words, this is a paradigm shift in the semi-controlled power exclusion, post-automation and domestic market.

Osteoporosis in Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환에서의 골다공증에 관한 연구)

  • Kim, Seong-Ja;Lee, Young-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.90-96
    • /
    • 1999
  • Background : Osteoporosis has been reported in patients with chronic obstructive pulmonary disease, but this association is not well established. This study was undertaken to determine whether the prevalence of osteoporosis was increased in patients with chronic obstructive pulmonary disease and we examined the relationship of corticosteroid administration with osteoporosis. Method: Subjects were 23 patients with chronic obstructive pulmonary disease and 20 control patients. We reviewed hospital records and measured bone mineral density using dual-energy x-ray absorptiometry(Lunar. USA). Results: Mean bone mineral density(BMD) of spine in COPD group was $0.683{\pm}0.154 g/cm^2$ and $0.971{\pm}0.212g/cm^2$ in controls(p<0.01). But there was no significant difference in femoral neck BMD. There were seventeen cases of osteoporosis and six cases of osteopenia in COPD group and three patients of osteoporosis and one case of osteopenia in controls. But, there was no significant correlation between disease duration of COPD and spinal T score(r=-0.395, p>0.05). Ten patients were received corticosteroid in COPD group. Spinal T score in steroid receiving patients were $-3.82{\pm}0.94(SD)$ and $-2.82{\pm}0.97(SD)$ in not having steroid patients(p<0.01). Cumulative dose of corticosteroid was associated with spinal T score(r=-0.424, p<0.05) and duration of corticosteroid administration also associated with spinal T score(r=-0.457. p<0.05). Spinal BMD of patients not having corticosteroid in COPD group(n=13) were significantly lower than that of controls($0.71{\pm}0.13 g/cm^2$ and $0.97{\pm}0.21 g/cm^2$, p<0.01). Conclusion : Prevalence of osteoporosis is increased in patients with chronic obstructive pulmonary disease. Especially patients who are receiving corticosteroid have high risk of osteoporosis or osteopenia and need for preventive management.

  • PDF

Development of Biocompatible Vascular Graft -Endothelialization of Small Vascular Graft- (생체적합성 인조혈관의 개발 -혈관내피화 인조혈관-)

  • 김형묵;이윤신
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.373-380
    • /
    • 1996
  • Prevention of thromboembolism is the most important task in the development of bioconpatible small caliber artificial vascular graft. In normal vessels, vascular endothelial cells maintain homeosatsis by secreting numerous factors. The aim of this study is to develope a method which Improves biocompatibility of small caliver polyurethane graft using endothelial cell culture technique, and ev luate the efTectiveness of extracelluar matrix for endothelization which was produced by cultured fibroblast. Methods ; Multiporous polyurethane tube of 3 mm diameter, 0.3 mm thickness was manufactured for vascular graft. Three mongrel dogs were intubated and internal jugular veins removed. Extracelluar matrix produced by cultured flbrobast which was obtained from dog's internal jugular vein were coated to the polyurethane graft. Then, endothelial cells extracted from Jugular vein were cultured and fixed on the extracelluar matrix layer of vascular graft. Endothelial cell coated vascular grafts were implanted to the carotid arteries of experimental dogs as interposed autograft. Implanted grafts were removed after 3 and 6 weeks. As a control, PTFE graft was interposed on carotid artery. These experiments demonstrated that extracelluar matrix produced by fibroblast can afford a base for endothelial cell linings of polyurethane graft. Although thrombosis were developed on autografted en othelial cell coated graft, 33% opening was noticed, and showed less adhesion to adjacent tissue layer. These findings suggest that fiboblast produced extracelluar matrix which can be used for edothelial cell lining vascular graft, and by improving the cultured endothelial cell function, there will be a new modality for reducing thrombosis on small vascular graft.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Development of the Home-Based Pulmonary Rehabilitation Program for Patients with Chronic Lung Disease (만성 폐질환 환자에서 재택 호흡재활치료방법 개발 연구)

  • Yoon, Seong-Ho;Na, Joo-Ok;JeGal, Yang-Jin;Kim, Myung-Wha;Kim, Eung-Suk;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.6
    • /
    • pp.597-607
    • /
    • 2002
  • Background : Even though it is well known that pulmonary rehabilitation (PR) improves exercise capacity, and the quality of life, in patients with chronic lung diseases, not many patients can attend hospital based intensive PR in Korea. The purpose of this study was to develop a method for a home-based PR program, and study its effectiveness. Materials and Methods : Twenty patients with chronic lung diseases were randomly divided into two groups : a home PR group comprising of 10 male patients, with a mean age of 70 years, and a control group comprising of 10 male patients, with a mean age of 65 years. We developed exercise programs, depending on the exercise capacity of each patient, which were easy to do at home. The PR program consisted of a 12 week period of enforced aerobic (mostly walking) and muscle strengthening exercises, as prescribed by the exercise specialist, in accordance with the functional capacity of the patient. In addition to the education, nutritional and psychiatric consultation was undertaken, and respiratory muscle training arranged. Patients visited hospital every 2 weeks for evaluation and exercise prescription. Results : All patients finished the 12 week course of therapy. Following the home PR, the endurance times and work capacity of the upper and lower extremities were significantly increased in the treatment group in comparison to the controls. The six minute working (Eds note:should) 'working' read "walking"?) distance was increased from $465{\pm}60m$ to $508{\pm}37m$ and the maximal inspiratory pressure from $72.8{\pm}27.2cmH_2O$ to $91.4{\pm}30.9cmH_2O$. The quality of life, as assessed by St Georges Respiratory Questionnaire (SGRQ), was also improved following PR. (Eds note:do you have figures for before and after, and a reference for the SGRQ?i.e. for the main paper.) Conclusion : The home PR program we developed seemed to be applicable, and effective, to most of the patients with chronic lung diseases in this study.

ITS2 DNA Sequence Analysis for Eight Species of Delphacid Planthoppers and a Loop-mediated Isothermal Amplification Method for the Brown Planthopper-specific Detection (멸구과 8종의 ITS2 DNA 염기서열 비교 분석과 고리매개등온증폭법(LAMP)을 이용한 벼멸구 특이 진단법)

  • Seo, Bo Yoon;Park, Chang Gyu;Koh, Young-Ho;Jung, Jin Kyo;Cho, Jumrae;Kang, Chanyeong
    • Korean journal of applied entomology
    • /
    • v.56 no.4
    • /
    • pp.377-385
    • /
    • 2017
  • Estimates of evolutionary sequence divergence and inference of a phylogenetic tree for eight delphacid planthopper species were based on the full-length nucleotide sequence of the internal transcribed spacer 2 (ITS2) region. Size of the ITS2 DNA sequence varied from 550 bp in Sogatella furcifera to 699 bp in Nilaparvata muiri. Nucleotide sequence distance ($d{\pm}S.E.$) was lowest between N. muiri and N. bakeri ($0.001{\pm}0.001$), and highest between Ecdelphax cervina and Stenocranus matsumurai ($0.579{\pm}0.021$). Sequence distance between N. lugens and other planthoppers ranged from $0.056{\pm}0.008$ (N. muiri) to $0.548{\pm}0.021$ (S. matsumurai). In the neighbor-joining phylogenetic tree, all planthoppers were clustered separately into a species group, except N. muiri and N. bakeri. The ITS2 nucleotide sequence of N. lugens was used to design four loop-mediated isothermal amplification (LAMP) primer sets (BPH-38, BPH-38-1, BPH-207, and BPH-92) for N. lugens species-specific detection. After the LAMP reaction of three rice planthoppers, N. lugens, S. furcifera, and Laodelphax striatellus, with the four LAMP primer sets for 60 min at $65^{\circ}C$, LAMP products were observed in the genomic DNA of N. lugens only. In the BPH-92 LAMP primer set, the fluorescence relative to that of the negative control differed according to the amount of DNA (0.1 ng, 10 ng, and 100 ng) and incubation duration (20 min, 30 min, 40 min, and 60 min). At $65^{\circ}C$ incubation, the difference was clearly observed after 40 min with 10 ng and100 ng, but with a 60-min incubation period, the minimum DNA needed was 0.1 ng. However, there was little difference in fluorescence among all DNA amounts tested with 20 or 30 min incubations.