• Title/Summary/Keyword: internal Stress Model

Search Result 449, Processing Time 0.03 seconds

Fluid-Structure Interaction Analysis of Blood Vessel Considering Internal Diameter Variation (내부직경 변화를 고려한 혈관의 유체-구조 상호작용 해석)

  • Octavianty, Ressa;Kim, Dong-Hyun;Kim, Su-Hyun;S. Nababan, Boyke;Byun, Jun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.959-963
    • /
    • 2006
  • A three-dimensional elastic blood vessel model with internal diameter variation is considered to investigate internal flow characteristics and effects of structural deformation. Also, computational analyses for both the rigid model and the fully-coupled FSI model have been conducted in order to compare the shear stress, pressure distribution, and flow velocity in detail. A 70% narrowing area of asymmetric blood vessel model was especially investigated to show the versatility of fluid-structure interaction phenomenon. The results reveal that effect of fluid-structure interaction is very important to accurately investigate the flow characteristics of the blood vessel.

  • PDF

Effect of Galhwahyejung-tang (GHT) on Alcohol-induced Oxidative Stress in Rats

  • Kim, Dong-Gyu;Kim, Tae-Hwan;Park, Sang-Eun;Kim, Hyung-Geug;Son, Chang-Gue;Hong, Sang-Hoon
    • The Journal of Korean Medicine
    • /
    • v.31 no.6
    • /
    • pp.1-7
    • /
    • 2010
  • Objectives: This study was aimed to investigate the effects of Galhwahyejung-tang (GHT) on alcohol-induced oxidative stress in rat model. Methods: Twenty SD rats were orally administrated with 40% ethanol (mL/kg) combined with GHT (50, 100, 200mg/kg) or distilled water for 2 weeks. Biochemistry in blood, malondialdehyde (MDA), total reactive oxygen species (ROS), and total antioxidant capacity (TAC) in serum, liver, brain, and kidney were determined. Results: GHT treatment significantly ameliorated the alcohol-induced alteration of hepatic enzyme; especially AST and ALT. GHT treatment also ameliorated the increase of MDA in liver, ROS level in serum and brain. GHT treatment reduced the depletion of antioxidant capacity in serum and brain. Conclusion: These results that GHT has antioxidant properties explaining the relevance of clinical application and its partial mechanisms of GHT.

INFLUENCE OF IMPLANT-ABUTMENT INTERFACE DESIGN, IMPLANT DIAMETER AND PROSTHETIC TABLE WIDTH ON STRENGTH OF IMPLANT-ABUTMENT INTERFACE : THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS (임플랜트의 지대주 연결방식, 임플랜트의 직경 및 지대주 연결부위의 직경 차이에 따른 응력분포에 관한 삼차원 유한요소분석)

  • Oh Se-Woong;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.393-404
    • /
    • 2003
  • Statement of problem. Higher incidence of prosthetic complications such as screw loosening, screw fracture has been reported for posterior single tooth implant. So, there is ongoing research regarding stability of implant-abutment interface. One of those research is increasing the implant diameter and prosthetic table width to improve joint stability. In another part of this research, internal conical type implant-abutment interface was developed and reported joint strength is higher than traditional external hex interface. Purpose. The purpose of this study is to compare stress distribution in single molar implant between external hex butt joint implant and internal conical joint implant when increasing the implant diameter and prosthetic table width : 4mm diameter, 5mm diameter, 5mm diameter/6mm prosthetic table width. Material and method. Non-linear finite element models were created and the 3-dimensional finite element analysis was performed to see the distribution of stress when 300N static loading was applied to model at $0^{\circ},\;15^{\circ},\;30^{\circ}$ off-axis angle. Results. The following results were obtained : 1. Internal conical joint showed lower tensile stress value than that of external hex butt joint. 2. When off-axis loading was applied, internal conical joint showed more effective stress distribution than external hex butt joint. 3. External hex butt joint showed lower tensile stress value when the implant diameter was increased. 4. Internal conical joint showed lower tensile stress value than external hex butt joint when the implant diameter was increased. 5. Both of these joint mechanism showed lower tensile stress value when the prosthetic table width was increased. Conclusion. Internal conical joint showed more effective stress distribution than external hex joint. Increasing implant diameter showed more effective stress distribution than increasing prosthetic table width.

A Study on Structural Improvement of the Swashplate Axial Piston Pump Valve Block (1) (사판 식 축 피스톤 펌프 밸브블록의 구조개선에 관한 연구(1))

  • Kim, Jeong-Hwa;Shin, Mi-Jung;Kim, Myung-Kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2018
  • This study aims to provide ways to achieve structural improvements of the internal flow path of the discharge plenum of a swash plate piston pump valve block vulnerable to cracks. This paper corresponds to Part I, which consists of a structural analysis of the valve block, identification of the stress distribution and stress raisers, and creation of a Simple Model of the valve block to review the optimal design. Structural analysis was performed by assigning the same conditions as those found in the valve block model, and the design was reviewed by examining three different design improvement plans for the internal flow path of the discharge plenum.

A Study on the Predictive Causal Model of Codependency for introducing Implications in Family Welfare Policy - Basing on the application of Triple ABC-X Model -

  • Ju, Sunyoung;Kweon, Seong-Ok;Park, Hwieseo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.3
    • /
    • pp.139-145
    • /
    • 2017
  • The purpose of this study is to establish a predictive causal model of codependency that is a main issue of family problem on the base of Triple ABC-X model which is a kind of family stress model. For the purpose of this study, we reviewed the concept and characteristics of codependency, affecting factors of codependency, and then reviewed the basic concept and logic of Triple ABC-X Model as theoretical viewpoint for the purpose of establishing a predictive causal model of codependency. We established it through examining main variables of codependency from Triple ABC-X Model. Main ingredients of the predictive causal model include boundary ambiguity, internal working model, internal and external locus of control, self-regard, social support, individual maladjustment etc. We established a predictive model of codependency basing on logic inferences among the variables. This study is expected to be used basic data to introduce some implications and for hereafter research.

A Study on Truss Model Incorporated with Internal Force State Factor for Shear Failure Mechanism in slender RC Beam (내력상태계수 개념을 도입한 철근콘크리트 보의 전단파괴 트러스모델에 관한 연구)

  • Cheong, Jae-Pyong;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.609-614
    • /
    • 2001
  • This paper is to explain reasonable shear behavior that can apply usually to reinforced concrete beams on the basic concepts of existent analysis and experimental research information. This study is succession $paper^{2) 3) 4) 5)}$ of treatise announced in existing and main control variable of reinforced concrete beams with stirrups used internal force state factor($\alpha$). Shear failure of reinforced concrete beams with stirrups is Influenced greatly because of the actual geometrical shape(a/d) of the concrete and flexural reinforcement steel ratio, stirrup reinforcement ratio and concrete compression strength, size effect etc. Therefore, shear behavior of reinforced concrete beams with stirrups that flexural crack is happened can be explained easily through proper extent proposal of internal force state factor($\alpha$) that express internal force state flowing. Use existent variable truss model by analysis model to explain arch action. Also, wish to compose each failure factors and correlation with internal force state factor by function, and when diagonal cracks happens, internal force state factor($\alpha$) study whether shear stress and some effect are.

  • PDF

Inelastic Stress Analysis of 1/4 Scale Prestressed Concrete Containment Vessel Model (프리스트레스 콘크리트 격납건물 1/4 축소모델의 비탄성응력해석)

  • 이홍표;전영선;신재철
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.301-308
    • /
    • 2004
  • The present study mainly focuses on the inelastic stress analysis of the 1/4 scale prestressed concrete containment vessel model(PCCV) under internal pressure and evaluates not only failure mode but also ultimate pressure capacity of the PCCV. Inelastic analysis is carried out 2D axisymmertic FE model and 3D FE model using four concrete material models which are Drucker-Prager Model, Chen-Chen Model, Damaged Plasticity Model and Menetrey-Willam Model. The uplift phenomenon of the basemat is considered in the 2D axisymmetric FE models. It is found from the 2D axisymmetric analysis results that both of Drucker-Prager model and Damaged Plasticity Model have a good performance and the uplift of the basemat is too small to influence on the global behavior of the PCCV. The FE analysis results on the ultimate pressure and failure mode have a good agreement with experimental results.

  • PDF

STRESS ANALYSIS OF SUPPORTING TISSUES AND IMPLANTS ACCORDING TO IMPLANT FIXTURE SHAPES AND IMPLANT-ABUTMENT CONNECTIONS (임플랜트 고정체의 형태와 연결방식에 따른 임플랜트 및 지지조직의 응력분포)

  • Han Sang-Un;Park Ha-Ok;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.226-237
    • /
    • 2004
  • Purpose: Four finite element models were constructed in the mandible having a single implant fixture connected to the first premolar-shaped superstructure, in order to evaluate how the shape of the fixture and the implant-abutment connection would influence the stress level of the supporting tissues fixtures, and prosthethic components. Material and methods : The superstructures were constructed using UCLA type abutment, ADA type III gold alloy was used to fabricate a crown and then connected to the fixture with an abutment screw. The models BRA, END , FRI, ITI were constructed from the mandible implanted with Branemark, Endopore, Frialit-2, I.T.I. systems respectively. In each model, 150 N of vertical load was placed on the central pit of an occlusal plane and 150 N of $40^{\circ}$ oblique load was placed on the buccal cusp. The displacement and stress distribution in the supporting tissues and the other components were analysed using a 2-dimensional finite element analysis . The maximum stress in each reference area was compared. Results : 1. Under $40^{\circ}$ oblique loading, the maximum stress was larger in the implant, superstructure and supporting tissue, compared to the stress pattern under vertical loading. 2. In the implant, prosthesis and supporting tissue, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 3. In the superstructure and implant/abutment interface, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 4. In the implant fixture, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 5 The stress was more evenly distributed in the bone/implant interface through the FRI of trapezoidal step design. Especially Under $40^{\circ}$ oblique loading, The maximum stress was smallest in the bone/implant interface. 6. In the implant and superstructure and supporting tissue, the maximum stress occured at the crown loading point through the ITI. Conclusion: The stress distribution of the supporting tissue was affected by shape of a fixture and implant-abutment connection. The magnitude of maximum stress was reduced with the internal connection type (FRI) and the morse taper type (ITI) in the implant, prosthesis and supporting tissue. Trapezoidal step design of FRI showed evenly distributed the stress at the bone/implant interface.

Stress Analysis for Differential Drying Shrinkage of Concrete (콘크리트의 부등건조수축으로 인한 응력의 해석)

  • 김진근;김효범
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.04a
    • /
    • pp.155-162
    • /
    • 1994
  • The drying shrinkage of concrete has a close relation to the water movement, Since the diffusion process of water in concrete is strongly dependent on the temperature and pore humidity, the process is highly nonlinear phenomena. It is shown that the analytical results of this study are in good agreement with experimental data in the literatures, and results calculated by BP-KX model. The internal stress caused by moisture distribution which was resulted from the diffusion process, was calculated quantitatively. The tensile stress which occurred in the drying outer zone mostly exceeded the tensile strength of concrete, and necessarily would result in crack formation.

  • PDF

A finite element stress analysis on the supporting bone and abutment screw by tightening torque of dental implant abutment screw (치과용 임플란트 지대주나사의 조임체결력에 따른 지지골과 지대주나사의 유한요소법 응력 분석)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.99-105
    • /
    • 2020
  • Purpose: A study analysed the stress distribution of abutment screw and supporting bone of fixture by the tightening torque force of the abutment screw within clinical treatment situation for the stability of the dental implant prosthesis. Methods: The finite element analysis was targeted to the mandibular molar crown model, and the implant was internal type 4.0 mm diameter, 10.0 mm length fixture and abutment screw and supporting bone. The occlusal surface was modeled in 4 cusps and loaded 100 N to the buccal cusps. The connection between the abutment and the fixture was achieved by combining three abutment tightening torque forces of 20, 25, and 30 Ncm. Results: The results showed that the maximum stress value of the supporting bone was found in the buccal cortical bone region of the fixture in all models. The von Mises stress value of each model showed 184.5 MPa at the 20 Ncm model, 195.3 MPa in the 25 Ncm model, and 216.5 MPa in the 30 Ncm model. The contact stress between the abutment and the abutment screw showed the stress value in the 20 Ncm model was 201.2 MPa, and the 245.5 MPa in the 25 Ncm model and 314.0 MPa in the 30 Ncm model. Conclusion: The increase of tightening force within the clinical range of the abutment screw of the implant dental prosthesis was found to have no problem with the stability of the supporting bone and the abutment screw.