• Title/Summary/Keyword: interim denture

Search Result 15, Processing Time 0.026 seconds

Digital interim immediate denture fabrication and implant-supported removable partial denture fabrication after multiple teeth extraction in patient with chronic periodontitis: a case report (만성 치주염 환자에서 다수치 발거 후 디지털 임시 즉시 의치 제작 및 임플란트 지지 가철성 국소의치 수복 증례)

  • Min-Jae Park;Ji-Won Bang;Joo-Hyuk Bang;Seon-Young Lim;Yong-Sang Lee;Keun-Woo Lee;Sung-Yong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.104-112
    • /
    • 2024
  • When teeth are extracted, patient face social, psychological and aesthetic problems which can be minimized by fabricating a interim immediate denture. Interim immediate denture manufactured using digital technology can be completed with reduced number of patients' visits and simple laboratory process. Implant-supported removable partial denture (ISRPD) has been suggested as alternative treatment option when fixed implant prosthesis is not feasible. In this case, interim immediate dentures were fabricated using digital technology for patient after teeth extraction and treatment using ISRPD by installing implants and surveyed crowns is found to be successful with better support, stability and maintenance of removable partial dentures.

Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report (디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례)

  • Jeong, Dae Gil;Oh, Kyung Chul;Shim, June Sung;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.397-404
    • /
    • 2019
  • Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.

Comparison of digitalized fabrication method for interim removable partial denture: case reports (두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고)

  • Yoon-Jeong Shin;Cheong-Hee Lee;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.379-385
    • /
    • 2023
  • With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.

3D printed interim immediate denture by using the occlusal plane digital transfer method of the POP BOW system in a patient planning to extract upper and lower residual teeth: a case report (상하악 전악 발거 환자에서 POP BOW 시스템의 교합평면 디지털 전이법을 이용한 3D 프린팅 임시 즉시의치의 수복 증례)

  • Park, Do-Hyun;Bae, Eun-Bin;Jung, In-Hwan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Lee, So-Hyoun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.3
    • /
    • pp.178-188
    • /
    • 2022
  • Interim immediate denture is fabricated to minimize the period of edentulousness after removal of the patient's remaining teeth and before delivery of final prosthesis. In the case of using the CAD/CAM system, there is an advantage in that the manufacturing process in the clinic and laboratory can be simplified by overcoming some of the limitations of manufacturing interim immediate dentures in the traditional way. However, there are also disadvantages in that errors occur in the process of transmitting information about the patient's intermaxillary relationship to the digital network of the laboratory, resulting in unstable occlusal relationships or non-esthetic prostheses. To overcome this problem, using the simple and accurate POP BOW system's occlusal plane digital transfer method, it was possible to fabricate an esthetic and functional 3D printed interim immediate denture after removal of the remaining upper and lower anterior teeth.

The case of interim denture applying for thermoforming technique (열형성 기술을 활용한 임시 의치 수복 증례)

  • Yun, Jun-Gu;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.2
    • /
    • pp.135-140
    • /
    • 2016
  • Patients who get tooth loss would also lost their esthetic, stability and functional aspect suddenly. They have to get provisional restoration immediately. This case reports a satisfied result that thermoforming technique is good for patients to get injury from unexpected tooth loss.

Fabrication of additive manufacturing interim denture and comparison with conventional interim denture: A case report (적층가공을 이용한 임시의치 제작 및 기존방식의 임시의치와의 비교 증례)

  • Kim, Hyun-Ah;Lim, Hyun-Pil;Kang, Hyeon;Yang, Hongso;Park, Sang-Won;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.483-489
    • /
    • 2019
  • With development of digital dentistry, the 3-dimensional (3D) manufacturing industry using computer-aided design and computer-aided manufacturing (CAD/CAM) has grown dramatically in recent years. Denture fabrication using digital method is also increasing due to the recent development of digital technology in dentistry. The 3D manufacturing process can be categorized into 2 types: subtractive manufacturing (SM) and additive manufacturing (AM). SM, such as milling is based on cutting away from a solid block of materal. AM, such as 3D printing, is based on adding the material layer by layer. AM enables the fabrication of complex structures that are difficult to mill. In this case, additive manufacturing method was applied to the fabrication of the resin-based complete denture to a 80 year-old patient. During the follow-up periods, the denture using digital method has provided satisfactory results esthetically and functionally.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

An alternative impression technique based on McLean's functional impression concept (McLean의 기능 인상법에 기반한 새로운 인상채득법)

  • Choi, Hyun-Suk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • In this case report, an alternative impression technique for fabricating removable partial dentures was used in a patient with very few remaining teeth. In this technique, an individual tray was made on the cast, which was made by relining interim denture and taking overimpression with irreversible hydrocolloid according to McLean's functional impression concept. This method showed the following advantages: the no need for border molding with modeling compound, time saving for denture impression without overextension and accurate seating of the individual tray.

Full-mouth rehabilitation of a patient with reduced occlusal vertical dimension due to severe wear: a clinical report (심한 마모로 인하여 교합 고경이 감소된 환자의 완전 구강 회복술)

  • Kim, Min-Jung;Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.39-46
    • /
    • 2013
  • The loss of posterior support may cause attrition of anterior teeth, and loss of occlusal vertical dimension (OVD). The collapse of the posterior support will eventually cause the pathologic change of the TMJ and masticatory muscles, unesthetic facial appearance and decreased masticatory function. Patients with destroyed dentition need extensive prosthetic treatments. Proper diagnosis and treatment planning are necessary for the stability of the neuromuscular system and the TMJ, and esthetic and functional definitive restorations. In this case, 63 year-old male presented with decreased masticatory force and esthetic problems due to pathologic destruction of teeth structure on entire dentition. Based on assessment of OVD including intraoral findings, radiographic examination and diagnostic cast, full-mouth rehabilitation with increase of OVD was planned using fixed partial denture and removable partial denture. Diagnostic wax-up was done after 4 mm increase of OVD determined by assessment of OVD. The OVD was maintained with the overlay type removable interim prostheses for 12 weeks to ascertain his comfort and adaptation to the new OVD. After the adaptation period, second interim prostheses with tooth preparation maintaining the established OVD was delivered. After 4 weeks, final prostheses were fabricated and delivered. After 7 month follow-up period, occlusal stability is maintained. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Prosthetic rehabilitation using an obturator in a fully edentulous patient who had partial maxillectomy (상악골 부분 절제술을 받은 무치악 환자에서의 구강폐쇄장치 수복)

  • Chung, Yoo-Jin;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.331-337
    • /
    • 2018
  • Prosthetic rehabilitation of an edentulous patient who has a maxillary defect is difficult to achieve for many clinicians. The maxillary defect causes leakage of air during pronunciation and compromises denture stability, support and retention by reducing denture-bearing area and breaking peripheral seal. In these patients, the sizes and shapes of defects are very important factors which attribute to prognosis of maxillary obturators. This case report shows the prosthetic rehabilitation of the patient who had maxillectomy on the right maxillary sinus because of squamous cell carcinoma. The patient had a stepwise treatment protocol which started with pre-operative dental examination and followed by surgical, interim and definitive obturation phase. In this case, an acceptable level of retention could be obtained due to well-defined static defects and the preserved premaxillae and the patient was satisfied with the result of the treatment in the aspect of function and esthetics.