DOI QR코드

DOI QR Code

Comparison of digitalized fabrication method for interim removable partial denture: case reports

두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고

  • 신윤정 (경북대학교 치과대학 치과보철학교실) ;
  • 이청희 (경북대학교 치과대학 치과보철학교실) ;
  • 이두형 (경북대학교 치과대학 치과보철학교실)
  • Received : 2023.08.11
  • Accepted : 2023.09.22
  • Published : 2023.10.31

Abstract

With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.

최근 디지털 치의학이 발달함에 따라 진료실 기반의 구내스캔과 computer-aided design/computer-aided manufacturing (CAD-CAM)을 이용한 완전 디지털 방식의 의치 제작이 증가하는 추세이다. 디지털 방식의 제작은 진료실과 기공실에서의 과정을 간소화하고 디지털 데이터를 보완할 수 있는 장점이 있다. 본 증례는 임플란트 식립이 불가하거나 지연되는 전치부 결손 환자에서 완전 디지털 제작 방식을 이용한 임시 가철성 의치의 수복 증례이다. 인공치와 의치상을 각각 디자인하고 프린팅하여 접착하는 방법과 인공치와 의치상을 일체형으로 디자인하고 프린팅하여 제작하는 두 가지 방법으로 임시 가철성 의치를 제작하고 구강 내 시적하였다. 발치 된 상태의 구내스캔, 임시 가철성 보철물을 구강 내에 장착 후의 구내 스캔과 보철물 자체의 스캔을 이용하는 삼중 스캔 기법으로 의치 적합도를 비교하였고, 두 가지 방법 모두에서 양호한 적합도를 보였다. 진료실 기반의 완전 디지털 방식을 이용하여 간소화된 과정으로 환자와 술자 모두 만족하는 결과를 얻었기에 본 증례를 보고하는 바이다.

Keywords

References

  1. Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: fabrication of complete dentures. Int J Prosthodont 1994;7:17-21.
  2. Bilgin MS, Erdem A, Aglarci OS, Dilber E. Fabricating complete dentures with CAD/CAM and RP technologies. J Prosthodont 2015;24:576-9. https://doi.org/10.1111/jopr.12302
  3. Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 2012;107:34-46. https://doi.org/10.1016/S0022-3913(12)60015-8
  4. Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc 2013;41:407-16. https://doi.org/10.1080/19424396.2013.12222317
  5. Wimmer T, Gallus K, Eichberger M, Stawarczyk B. Complete denture fabrication supported by CAD/CAM. J Prosthet Dent 2016;115:541-6. https://doi.org/10.1016/j.prosdent.2015.10.016
  6. Infante L, Yilmaz B, McGlumphy E, Finger I. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent 2014;111:351-5. https://doi.org/10.1016/j.prosdent.2013.10.014
  7. Lo Russo L, Salamini A. Removable complete digital dentures: a workflow that integrates open technologies. J Prosthet Dent 2018;119:727-32. https://doi.org/10.1016/j.prosdent.2017.06.019
  8. Lee WS, Lee DH, Lee KB. Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system. J Adv Prosthodont 2017;9:265-70. https://doi.org/10.4047/jap.2017.9.4.265
  9. Torabi K, Farjood E, Hamedani S. Rapid prototyping technologies and their applications in prosthodontics, a review of literature. J Dent (Shiraz) 2015;16:1-9.
  10. Baba NZ, AlRumaih HS, Goodacre BJ, Goodacre CJ. Current techniques in CAD/CAM denture fabrication. Gen Dent 2016;64:23-8.
  11. Mai HY, Lee WK, Kwon TG, Lee DH. Reliability of digital measurement methods on the marginal fit of fixed prostheses: A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2020; 124:350.e1-11. https://doi.org/10.1016/j.prosdent.2020.04.011
  12. Choi JJE, Uy CE, Plaksina P, Ramani RS, Ganjigatti R, Waddell JN. Bond strength of denture teeth to heat-cured, CAD/CAM and 3D printed denture acrylics. J Prosthodont 2020;29:415-21. https://doi.org/10.1111/jopr.13125
  13. Deng K, Chen H, Zhao Y, Zhou Y, Wang Y, Sun Y. Evaluation of adaptation of the polylactic acid pattern of maxillary complete dentures fabricated by fused deposition modelling technology: A pilot study. PLoS One 2018;13:e0201777.
  14. Boitelle P, Tapie L, Mawussi B, Fromentin O. Evaluation of the marginal fit of CAD-CAM zirconia copings: Comparison of 2D and 3D measurement methods. J Prosthet Dent 2018;119:75-81. https://doi.org/10.1016/j.prosdent.2017.01.026
  15. Anadioti E, Aquilino SA, Gratton DG, Holloway JA, Denry I, Thomas GW, Qian F. 3D and 2D marginal fit of pressed and CAD/CAM lithium disilicate crowns made from digital and conventional impressions. J Prosthodont 2014;23:610-7. https://doi.org/10.1111/jopr.12180