장수명 공동주택 목업하우스 적용 인필시스템에 관한 연구 (A Study on the Infill system applied to Mock-up house of the long life housing)

  • 박경순;강혁;송진용;손원득
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.558-562
    • /
    • 2008
  • This study is being conducted to develope an infill system applied to Mock-Up House of the Korean long life housing. This paper presents result of study and an infill system applied to Mock-up house, commenced in June 2005. We also present the mechanical system and technology, the capability of interface, and other factors.

  • PDF

폴리머 마이크로 장치에 대한 레이저 투과 마이크로 접합 (Analysis of Transmission Infrared Laser Bonding for Polymer Micro Devices)

  • 김주한;신기훈
    • Journal of Welding and Joining
    • /
    • 제23권5호
    • /
    • pp.55-60
    • /
    • 2005
  • A precise bonding technique, transmission laser bonding using energy transfer, for polymer micro devices is presented. The irradiated IR laser beam passes through the transparent part and absorbed on the opaque part. The absorbed energy is converted into heat and bonding takes place. In order to optimize the bonding quality, the temperature profile on the interface must be obtained. Using optical measurements of the both plates, the absorbed energy can be calculated. At the wavelength of 1100nm $87.5\%$ of incident laser energy was used for bonding process from the calculation. A heat transfer model was applied for obtaining the transient temperature profile. It was found that with the power of 29.5 mW, the interface begins to melt and bond each other in 3 sec and it is in a good agreement with experiment results. The transmission IR laser bonding has a potential in the local precise bonding in MEMS or Lab-on-a-chip applications.

A Generalized Model for Homogenized Reflectors

  • Pogosbekyan, Leonid;Kim, Yeong-Il;Kim, Young-Jin;Joo, Hyung-Kook
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.40-45
    • /
    • 1996
  • A new concept of equivalent homogenization is proposed. The concept employs new set of homogenized parameters: homogenized cross sections (XS) and interface matrix (IM), which relates partial currents at the celt interfaces. The idea of interface matrix generalizes the idea of discontinuity factors (DFs), proposed and developed by K.Koebke and K.Smith. The method of K.Smith can be simulated within framework of new method, while the new method approximates heterogeneous cell better in case of the steep flux gradients at the cell interfaces. The attractive shapes of new concept are: improved accuracy, simplicity of incorporation in the existing codes, equal numerical expenses in comparison to the K.Smith's approach. The new concept is useful for: (a) explicit reflector/baffle simulation; (b) control blades simulation; (c) mixed UO2/MOX core simulation, The offered model has been incorporated in the finite difference code and in the nodal code PANBOX. The numerical results show good accuracy of core calculations and insensitivity of homogenized parameters with respect to in- core conditions.

  • PDF

A transport model for high-frequency vibrational power flows in coupled heterogeneous structures

  • Savin, Eric
    • Interaction and multiscale mechanics
    • /
    • 제1권1호
    • /
    • pp.53-81
    • /
    • 2008
  • The theory of microlocal analysis of hyperbolic partial differential equations shows that the energy density associated to their high-frequency solutions satisfies transport equations, or radiative transfer equations for randomly heterogeneous materials with correlation lengths comparable to the (small) wavelength. The main limitation to the existing developments is the consideration of boundary or interface conditions for the energy and power flow densities. This paper deals with the high-frequency transport regime in coupled heterogeneous structures. An analytical model for the derivation of high-frequency power flow reflection/transmission coefficients at a beam or a plate junction is proposed. These results may be used in subsequent computations to solve numerically the transport equations for coupled systems, including interface conditions. Applications of this research concern the prediction of the transient response of slender structures impacted by acoustic or mechanical shocks.

Black Cr 태양 선택흡수막의 SIMS 연구 (SIMS Investigation of Black Cr Solar Selective Coatings)

  • 이길동
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.39-44
    • /
    • 2014
  • The elemental composition of electro-deposited black Cr solar selective coatings before and after heating in air by using secondary ion mass spectrometry (SIMS) was investigated for optical property analysis. In addition, black Cr selective coating exposed by solar radiation for 5 months was compared with heated sample. SIMS investigation shows that $OH^+$ bearing ions were related to a near surface region of CrOH and CrO compound. The optical degradation of this coating after heating at $500^{\circ}C$ reveals that diffusion of the Cu and Ni elements in substrate material, the chemical interactions adjacent to the interface, and the interface width broadening.

반도전성 실리콘 고무의 표면 특성과 접착특성에 미치는 플라즈마 처리의 영향 (The Effect of Plasma Treatment on Surface Properties and Adhesion Characteristics of semiconductive Silicone Rubber)

  • 황선묵;홍주일;황청호;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.254-255
    • /
    • 2005
  • In this work, the effects of plasma treatment on surface properties of semi conductive silicone rubber were investigated in terms of X-ray photoelectron spectroscopy(XPS). The adhesion characteristics of semiconductive-insulating interface layer of silicone rubber were studied by measuring the T-peel strengths. As a result, semiconductive silicone rubber surfaces treated with plasma discharge led to and increase in oxygen-containing functional groups, resulting in improving the degree of adhesion of the semiconductive-insulating interface layer of silicone rubber. these results are probably due to the modifications of surface functional groups or polar component of surface free energy of the semi conductive silicone rubber.

  • PDF

Surface and Interfacial Energetic Analysis of Amphiphilic Copolymers

  • Kim, Min-Kyun;Yuk, Soon-Hong;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • 제8권3호
    • /
    • pp.158-161
    • /
    • 1987
  • A Series of hydrophilic-hydrophobic copolymeric surfaces of 2-hydroxyethyl methacrylate (HEMA) and various alkyl methacrylate (RMA) have been prepared by in-situ solution copolymerization using a redox radical initiator. Contact angles of various probing fluids on the polymeric surfaces were determined in air (hydrophobic environment) and under water (hydrophilic environment). From contact angle data, the dispersive interaction contribution (${\gamma}^d_s$) and the polar contribution (${\gamma}^p_s$) to the total surface free energy (${\gamma}^d_s$) and interfacial energetic quantities (e.g., water-polymer, liquid-polymer interface, etc.) were estimated by surface and interface physicochemical theory. From the comparison of surface energetic components between hydrophobic and hydrophilic media, it is found that surface and interface energetic components of polymeric surface as a representative low-energy surface are highly dependent on environmental fluids. Also, from the correlation between interfacial energetic results and surface energetic criterion of biocompatibility, we found that HEMA/BMA, HEMA/HMA copolymer systems are in the region of biocompatibility.

Test for the influence of socket connection structure on the seismic performance of RC prefabricated bridge piers

  • Yan Han;Shicong Ding;Yuxiang Qin;Shilong Zhang
    • Earthquakes and Structures
    • /
    • 제25권2호
    • /
    • pp.89-97
    • /
    • 2023
  • In order to obtain the impact of socket connection interface forms and socket gap sizes on the seismic performance of reinforced concrete (RC) socket prefabricated bridge piers, quasi-static tests for three socket prefabricated piers with different column-foundation connection interface forms and reserved socket gap sizes, as well as to the corresponding cast-in-situ reinforced concrete piers, were carried out. The influence of socket connection structure on various seismic performance indexes of socket prefabricated piers was studied by comparing and analyzing the hysteresis curve and skeleton curve obtained through the experiment. Results showed that the ultimate failure mode of the socket prefabricated pier with circumferential corrugated treatment at the connection interface was the closest to that of the monolithic pier, the maximum bearing capacity was slightly less than that of the cast-in-situ pier but larger than that of the socket pier with roughened connection interface, and the displacement ductility and accumulated energy consumption capacity were smaller than those of socket piers with roughened connection interface. The connection interface treatment form had less influence on the residual deformation of socket prefabricated bridge piers. With the increase in the reserved socket gap size between the precast pier column and the precast foundation, the bearing capacity of the prefabricated socket bridge pier component, as well as the ductility and residual displacement of the component, would be reduced and had unfavorable effect on the energy dissipation property of the bridge pier component.

계면경사가 있는 GaAs/(Al, Ga)As 초격자의 밴드구조 (The Band Structure of GaAs/(Al,Ga)As Superlattice with Interface Grading)

  • 김장래;김충원;한백형
    • 대한전자공학회논문지
    • /
    • 제25권3호
    • /
    • pp.287-293
    • /
    • 1988
  • This paper calculates the band structure of the GaAs/(Al,Ga) As semiconductor superlttice with the interface3 grading, in consideration of different effective masses in each region. Including the effective masses, superlattice period, well and barrier widths, and the interface, the dispersion relation is derived, and the effects that the above parameters affect the subband (or miniband) structure of the superlattice and effective energy gap are investigated. It is particularly found that this case(ma<>mb<>mc) is significantly different from the same effective mass case(ma<>mb<>mc).

  • PDF