• Title/Summary/Keyword: interclass correlation coefficient

Search Result 14, Processing Time 0.033 seconds

DEVELOPING NONINFORMATIVE PRIORS FOR THE FAMILIAL DATA

  • Heo, Jung-Eun;Kim, Yeong-Hwa
    • Journal of the Korean Statistical Society
    • /
    • v.36 no.1
    • /
    • pp.77-91
    • /
    • 2007
  • This paper considers development of noninformative priors for the familial data when the families have equal number of offspring. Several noninformative priors including the widely used Jeffreys' prior as well as the different reference priors are derived. Also, a simultaneously-marginally-probability-matching prior is considered and probability matching priors are derived when the parameter of interest is inter- or intra-class correlation coefficient. The simulation study implemented by Gibbs sampler shows that two-group reference prior is slightly edge over the others in terms of coverage probability.

A Study of Evaluating Eye Movement Based on Ocular Motor Score for Children with Spastic Cerebral Palsy

  • Jeong, Seo-Young;Oh, Tae-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.6
    • /
    • pp.341-347
    • /
    • 2020
  • Purpose: The purpose of this study is to introduce a tool for evaluating eye movement and analyze the reliability of measurement based on 10 cases of evaluating the oculomotor function of children with spastic cerebral palsy Methods: The participants were selected by 6 medical and welfare institutions in Busan as GMFCS grade 1-3 among spastic diplegia and hemiplegia. Seven examiners evaluated 3 children for the evaluation of inter-rater agreement of Ocular Motor Score (OMS) and evaluated the condition of the ocular motor of 10 children using OMS, a re-examination was performed at six weeks after the initial examination. SPSS ver.25.0 was used to calculate the interclass correlation coefficient and Wilcoxon's signed-rank test, Mann Whitney-U test. Results: The inter-rater agreement of OMS was 0.89. Second mean values were decreased compared first examination in motility/ductions/version, saccades and smooth pursuit, but there was no significant difference. Children under 6 years old had a high mean value of saccades in first examination and the motility/ductions/version, fixation, saccades in second examination, but there was no significant difference. Spastic diplegia children's mean values were higher in head posture, fixation in 8 gaze directions than hemiplegia children in both first and second examination, but there were no significant differences. Conclusion: Ocular motor function in 10 children of spastic children who participated in the study and could see that the scores was differed depending on age, type, grade of cerebral palsy. OMS may be available for this purpose.

An Experimental Study on the Effect of Domain Expertise on the Consistency of Relevance Judgements (주제전문지식이 적합성판정의 일관성에 미치는 영향에 관한 실험적 연구)

  • Scholten, Stacey;Moon, Sung-Been
    • Journal of the Korean Society for information Management
    • /
    • v.38 no.3
    • /
    • pp.1-22
    • /
    • 2021
  • An online experiment was conducted to test the subject-knowledge view of relevance theory in order to find evidence of a conceptual basis for relevance. Six experts in Library and Information Science (LIS), nine Master's students of LIS, and twelve non-experts judged the relevance of 14 abstracts within and outside of the LIS domain. Consistency among the judges was calculated by joint-probability agreement (PA) and interclass correlation coefficients (ICC). When using PA to analyze the judgements, non-experts had a higher consensus regardless of the task or division of groups. However, ICC calculations found Master's candidates had a higher level of consensus than non-experts within LIS, although the experts did not; and the agreement rates on the non-LIS task for all groups were only poor to moderate. It was only when the groups were analyzed as two groups (experts including Master's candidates and non-experts) that the expected trend of higher consistency among experts in the LIS task was seen.

Reliability and Validity of Korean-Version of Information Needs in Cardiac Rehabilitation Scale

  • Choi, Sang Young Heon;Kim, Joong Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.5
    • /
    • pp.234-241
    • /
    • 2022
  • Purpose: The Cardiac Rehabilitation scale (INCR scale) is a verified measure worldwide. The scale measures the extent to which cardiac rehabilitation meets the various needs of the participating patients and determines how education related to heart disease and rehabilitation satisfies their preferences. The current study applied the INCR scale to verify and develop it for use in Korea by conforming to Korean culture and language. Methods: The Korean version of the INCR scale was created after a six-step process in accordance with the international questionnaire translation law. The Korean version of the INCR scale was assessed in 45 cardiac rehabilitation patients (29 males, 16 females). Internal consistency was verified using Cronbach's alpha. Test-re-test reliability and interrater reliability were verified using the intraclass correlation coefficient (ICC). Content validity was selected to verify the validity. Results: The content validity index of the Korean version of the INCR scale was high, with an average of 0.93. Cronbach's Alpha for Internal consistency also revealed high reliability of 0.89 in all 10 categories. The interclass correlation coefficient of the test-re-test and interrater reliability scores were 0.95 and 0.81, respectively. Conclusion: Our results indicate that the Korean version of the INCR scale would be instrumental in the clinical setting to determine the knowledge, educational needs, and preferences of patients participating in cardiovascular disease and cardiac rehabilitation.

Comparison of Correlation Coefficients and Intraclass Correlation Coefficients Between Two-way FSI Flow Velocity of Simulated Abdominal Aorta and Human 4D Flow MRI Flow Velocity (시뮬레이션 복부 대동맥의 양방향 FSI 유속과 인체 4D flow MRI 유속의 상관계수, 급내상관계수 비교)

  • Ahn, Hae Nam;Kim, Jung Hun;Park, Ji eun;Choi, Hyeun Woo;Lee, Jong Min
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.143-149
    • /
    • 2021
  • In order to predict and prevent the disease of the abdominal aorta, which is the largest artery in the human body and the most common aneurysm, the normal arterial blood flow operation should be considered. To this end, we are trying to solve problems that may arise in the future by executing FSI based on the data obtained from 4D flow MRI. However, to match the similarity between the 4D flow MRI flow and the FSI flow, correlation was used in previous papers, but the correlation did not show the degree of agreement. Therefore, in this paper, we analyzed the correlation between the 4D flow MRI flow velocity of the human abdominal aorta and the two-way FSI flow velocity in which the three physical properties used for the aortic FSI were added to the CT abdominal aorta 3D model and the interclass correlation coefficient. As a result, the physical property M2 showed the highest similarity in correlation and intraclass correlation coefficient, and this property is intended to be helpful in the future study of the abdominal aortic two-way FSI flow rate.

Observer Variation Factor on Advanced Method for Accurate, Robust, and Efficient Spectral Fitting of java Based Magnetic Resonance User Interface for MRS data analysis (java Based Magnetic Resonance User Interface의 Advanced Method for Accurate, Robust, and Efficient Spectral Fitting 분석방법의 관찰자 변동 요소)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.143-148
    • /
    • 2016
  • The purpose of this study was examined the measurement error factor on AMARES of jMRUI method for magnetic resonance spectroscopy (MRS) quantitative analysis by skilled and unskilled observer method and identified the reason of independent observers. The Point-resolved spectroscopy sequence was used to acquired magnetic resonance spectroscopy data of 10 weeks male Sprague-Dawley rat liver. The methylene protons ($(-CH_{2-})n$) of 1.3 ppm and water proton ($H_2O$) of 4.7 ppm ratio was calculated by LCModel software for using the reference data. The seven unskilled observers were calculated total lipid (methylene/water) using the jMRUI AMARES technique twice every 1 week, and we conducted interclass correlation coefficient (ICC) statistical analysis by SPSS software. The inter-observer reliability (ICC) of Cronbach's alpha value was less than 0.1. The average value of seven observer's total lipid ($0.096{\pm}0.038$) was 50% higher than LCModel reference value. The jMRUI AMARES analysis method is need to minimize the presence of the residual metabolite by identified metabolite MRS profile in order to obtain the same results as the LCModel.

Method Development and Cross Validation of Analysis of Hydroxylated Polycyclic Aromatic Hydrocarbons (OH-PAHs) in Human Urine (소변 중 다환방향족탄화수소 대사체의 분석법 확립 및 교차분석)

  • Park, Na-Youn;Jeon, Jung-Dae;Koo, Hyeryeong;Kim, Jung Hoan;Lee, Eun-Hee;Lee, Kyungmu;Mun, Cheoljin;Kho, Younglim
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.5
    • /
    • pp.358-367
    • /
    • 2015
  • Objectives: This study was performed to evaluate the analytical method for PAH metabolites in human urine using enzyme hydrolysis and solid-phase extraction coupled with LC-(ESI)-MS/MS technique. Methods: We employed HPLC tandem mass spectrometry techniques with appropriate pre-treatment for analysis of 16 OH-PAHs in human urine. Samples were hydrolysis by ${\beta}$-flucuronidase/Aryl sulfatase, and target compounds were extracted by solid-phase extraction with a strata-x cartridge. Cross-validation was performed between Eulji University and Green Cross laboratories with 200 human urine samples. Results: The accuracies were between 90.3% and 118.8%, and precisions (relative standard deviations) were lower than 10%. The linearity obtained was satisfying for the 16 OH-PAH compounds, with a coefficient of determination ($r^2$) higher than 0.99. The results of cross-validation at the two organizations were compared by ICC (interclass correlation coefficient) values. The cross-validation results were excellent or good for all compounds. Conclusion: An analytical method was validated for low nanogram levels of 16 OH-PAHs in human urine. Also, satisfying results were obtained for method validation such as accuracy, precision and ICC of cross-validation.

Fit Performance Comparison Between OPC and CNC Based on Number of Ambient Aerosol Particles (시험환경 내 입자수에 대한 OPC, CNC 장비 간 마스크 밀착 성능비교)

  • Seo, Hyekyung;Jang, Hoyeong;Shim, Sua;Kim, Huiju;Han, Donhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.163-171
    • /
    • 2022
  • Objectives: Fit performance may vary depending on the ambient aerosol number and ratio in respective test environment. Although several instrument can measure it, they differ with respect to the measurement principle and the range of ambient aerosols collected to calculate the fit factor. Methods: In this study, the fit performance between a condensation nuclei counter(CNC) and an optical particle counter(OPC) was compared according to ambient aerosol number concentration, and evaluated consistency. One type respirators(N95 masks) was worn by 50 participants PortaCount®(Pro+ 8038) and MT®(05U) were connected with one probe to one mask, and Fit Factors(FFs) were measured simultaneously. Results: The interclass correlation coefficient of the fit factor and ambient aerosol number, as measured by the two instrument, was 0.82 and 0.79, respectively, indicating a high consistency level. On the other hand there was a significant correlation between the successful test performance of the OPC instrument and the ambient aerosol number. Conclusions: The test was passed with the CNC and OPC instruments when the ambient aerosol number was 635-3,332 particles/cm3 and 368-1,976 particles/cm3, respectively. Thus, the ideal ambient aerosol number of particles differed between the two instrument.

Development and Psychometric Evaluation of the Patient Safety Violation Scale in Medical Oncology Units in Iran

  • Shali, Mahboobeh;Ghaffari, Fatemeh;Joolaee, Soodabeh;Ebadi, Abbas
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4341-4347
    • /
    • 2016
  • Background: Patient safety is one of the key components of nursing care for cancer cases. Valid and reliable context-based instruments are necessary for accurate evaluation of patient safety in oncology units. The aim of the present study was to develop and evaluate the psychometric properties of the Patient Safety Violation Scale in medical oncology units in Iran. Materials and Methods: In this methodological study, a pool of 58 items was generated through reviewing the existing literature. The validity of the 58-item scale was assessed through calculating impact score, content validity ratio, and content validity index for its items as well as conducting exploratory factor analysis. The reliability of the scale was evaluated by assessing its internal consistency and testretest stability. Study sample consisted of 300 oncology nurses who were recruited from thirteen teaching hospitals affiliated to Tehran University of Medical Sciences, Tehran, Iran. Results: Sixteen items were excluded from the scale due to having low impact scores, content validity ratios, or content validity indices. In exploratory factor analysis, the remaining 42 items were loaded on five factors including patient fall, verification of patientidentity, harm during care delivery, delay in care delivery, and medication errors. These five factors explained 62% of the total variance. The Cronbach's alpha of the scale and the test-retest interclass correlation coefficient were equal to 0.933 and 0.92, respectively. Conclusions: The 42-item Patient Safety Violation Scale is a simple and short scale which has acceptable validity and reliability. Consequently, it can be used for assessing patient safety in clinical settings such as medical oncology units and for research projects.

Accuracy of dental model based on the state-of-the-art manufacturing technique (첨단 제조기술 기반으로 제작된 치과용 모형의 정확도에 관한 연구)

  • Kim, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.693-700
    • /
    • 2020
  • This study compared the accuracy and reliability of definitive casts fabricated from a digital impression and conventional impression technique. A master model with the prepared upper full-arch tooth was used. Samples of ten plaster models and ten polyurethane models were duplicated using a selected standard master model. Six linear measurements were recorded between the landmarks, directly on each of the stone models and the polyurethane models on two occasions by a double examiner. The Wilcoxon signed-rank test, interclass correlation coefficient (ICC), measurement error (MSE), and limit of agreement (LoA) were used for statistical analysis. The ICC ranged from 0.76 to 0.99 when comparing the stone models and polyurethane models. The mean difference between the stone models and polyurethane models ranged from 0.09mm to 0.20mm, suggesting that stone models might be slightly larger than polyurethane models. Based on this study, the accuracy of the polyurethane models in evaluating the performance of an oral scanner and subtractive technology was acceptable. Further studies will be needed on patient subjects under clinical conditions that may involve missing or malpositioned teeth and fixed dental prostheses because this study was limited to use a standard master model and duplicated sample models in a laboratory setting.