• 제목/요약/키워드: inter-comparison

검색결과 505건 처리시간 0.023초

Effect of the Plasma-assisted Patterning of the Organic Layers on the Performance of Organic Light-emitting Diodes

  • Hong, Yong-Taek;Yang, Ji-Hoon;Kwak, Jeong-Hun;Lee, Chang-Hee
    • Journal of Information Display
    • /
    • 제10권3호
    • /
    • pp.111-116
    • /
    • 2009
  • In this paper, a plasma-assisted patterning method for the organic layers of organic light-emitting diodes (OLEDs) and its effect on the OLED performances are reported. Oxygen plasma was used to etch the organic layers, using the top electrode consisting of lithium fluoride and aluminum as an etching mask. Although the current flow at low voltages increased for the etched OLEDs, there was no significant degradation of the OLED efficiency and lifetime in comparison with the conventional OLEDs. Therefore, this method can be used to reduce the ohmic voltage drop along the common top electrodes by connecting the top electrode with highly conductive bus lines after the common organic layers on the bus lines are etched by plasma. To further analyze the current increase at low voltages, the plasma patterning effect on the OLED performance was investigated by changing the device sizes, especially in one direction, and by changing the etching depth in the vertical direction of the device. It was found that the current flow increase at low voltages was not proportional to the device sizes, indicating that the current flow increase does not come from the leakage current along the etched sides. In the etching depth experiment, the current flow at low voltages did not increase when the etching process was stopped in the middle of the hole transport layer. This means that the current flow increase at low voltages is closely related to the modification of the hole injection layer, and thus, to the modification of the interface between the hole injection layer and the bottom electrode.

개질 처리된 저발열 슬래그시멘트 특성에 관한 연구 (The research about properties of modified low heat slag cement)

  • 김홍주;김원기;김훈상;이원준;신진호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.677-680
    • /
    • 2008
  • 저발열형 고로슬래그 시멘트의 초기강도 발현 특성을 향상시키기 위하여 낮은 분말도의 고로슬래그 분말과 보통 포틀랜드시멘트를 혼합 분쇄하여 입자 표면을 개질하였다. 사전 분쇄한 고로슬래그 분말의 비표면적은 $2535cm^2/g$(BS2), $3245cm^2/g$(BS3)의 2가지를 사용하였으며, 고로슬래그 분말과 시멘트를 진동밀에 투입하여 10분부터 30분까지 혼합 분쇄하여 표면을 개질하였다. 시멘트에 대한 고로슬래그 분말의 혼합비는 60$^{\sim}$80%의 3수준으로 변화시켰으며 혼합분쇄 후 비표면적의 변화, 입도분표, 시멘트의 수화열, 몰탈의 압축강도를 측정하였다. 시판 삼성분계 저발열 시멘트(LHC)와 비교시험 결과, 7일 압축강도발현의 100%이상과 72시간 누적수화열 170J/g 이하의 값을 만족하는 배합 및 혼합분쇄 시간을 찾을 수 있었으며 저분말도 고로슬래그를 다량으로 활용한 저발열 슬래그시멘트의 가능성을 확인하였다.

  • PDF

Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position

  • Ha, Sung-Min;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.

Evaluation of GSICS Correction for COMS/MI Visible Channel Using S-NPP/VIIRS

  • Jin, Donghyun;Lee, Soobong;Lee, Seonyoung;Jung, Daeseong;Sim, Suyoung;Huh, Morang;Han, Kyung-soo
    • 대한원격탐사학회지
    • /
    • 제37권1호
    • /
    • pp.169-176
    • /
    • 2021
  • The Global Space-based Inter-Calibration System (GSICS) is an international partnership sponsored by World Meteorological Organization (WMO) to continue and improve climate monitoring and to ensure consistent accuracy between observation data from meteorological satellites operating around the world. The objective for GSICS is to inter-calibration from pairs of satellites observations, which includes direct comparison of collocated Geostationary Earth Orbit (GEO)-Low Earth Orbit (LEO) observations. One of the GSICS inter-calibration methods, the Ray-matching technique, is a surrogate approach that uses matched, co-angled and co-located pixels to transfer the calibration from a well calibrated satellite sensor to another sensor. In Korea, the first GEO satellite, Communication Ocean and Meteorological Satellite (COMS), is used to participate in the GSICS program. The National Meteorological Satellite Center (NMSC), which operated COMS/MI, calculated the Radiative Transfer Model (RTM)-based GSICS coefficient coefficients. The L1P reproduced through GSICS correction coefficient showed lower RMSE and Bias than L1B without GSICS correction coefficient applied. The calculation cycles of the GSICS correction coefficients for COMS/MI visible channel are provided annual and diurnal (2, 5, 10, 14-day), but long-term evaluation according to these cycles was not performed. The purpose of this paper is to perform evaluation depending on the annual/diurnal cycles of COMS/MI GSICS correction coefficients based on the ray-matching technique using Suomi-NPP/Visible Infrared Imaging Radiometer Suite (VIIRS) data as reference data. As a result of evaluation, the diurnal cycle had a higher coincidence rate with the reference data than the annual cycle, and the 14-day diurnal cycle was the most suitable for use as the GSICS correction coefficient.

남북 전통의학 용어 표준화의 필요성과 향후 과제 (Standardizing of Medicine Terminology in South and North Korea and Future Management Plan)

  • 김동수;이은희;최문석
    • 대한예방한의학회지
    • /
    • 제24권3호
    • /
    • pp.15-25
    • /
    • 2020
  • Background : Mutual understanding between North and South Korea is essential for the engagement of Inter-Korean exchange and cooperation. However, the two Koreas have been divided for 70 years where Korean evolved differently within the two countries. This created a gap in the most basic foundation for mutual understanding, language. Fostering exchange and cooperation in the traditional medicine field requires a higher understanding of the specialized traditional medicine terminologies. Objectives : The purpose of this study is to formulate a future management plan for the "Comparative Terminology of Korean Medicine in South and North Korea," providing a foundation for standardizing Korean medicine terminology of the two Koreas. Methods : The study collected case studies of Korean medicine terminology management and standardization from government and international organization websites and documents. It provided future terminology management strategies based on this data. Results : The project for the standardization of Korean medicine terminology between North and South Korea can be divided into 4 stages according to the level of exchange and cooperation. The first step is to "establish a foundation for terminology standardization." The second step is "term comparison." If the exchanges and cooperation between North and South Korea, the third step will be to promote the "terminology standardization" project through Inter-Korean dialogue. Finally, after incorporating discussion on terminology standardization, the Inter-Korean Medicine Terminology can be published. Conclusions : This requires a system to support and facilitate Inter-Korean medicine exchange and cooperation. It is important to provide a support system that can provide results in a timely fashion by training relevant experts, collecting data and information, communicating with experts in the industry, academia and research institutes. This system will be able to ensure the continuity of the terminology standardization project.

정신분열병과 양극성장애에서 뇌파 동시성의 비교분석 (The Differences of EEG Coherence between Schizophrenia and Bipolar Disorder)

  • 김용규;신재공;박종원;홍경수;이승연;오홍석;이용석;곽용태;장재승;이유상
    • 생물정신의학
    • /
    • 제12권2호
    • /
    • pp.123-135
    • /
    • 2005
  • Objectives:EEG coherence could imply the connectivity between two different areas of the brain, which is known to be important in the pathophysiology of bipolar I disorder(BPD I) and schizophrenia. The authors investigated EEG coherence in patients with BPD I and schizophrenia to examine the connectivity of the neural circuit. Methods:EEGs were recorded in 15 schizophrenia and 14 bipolar disorder patients, and 14 age-matched normal control subjects from 16 electrodes with linked-ear reference. Spectral parameters and coherence were calculated for the alpha bandwidth(8-13Hz) by a multi-channel autoregressive model using 20 artifact-free 2-seconds epochs and the differences were compared among three groups by two different statistical methods;F-test and Kruskal-Wallis test. Furthermore, when there were significant differences among three groups, Scheffe's multiple comparison tests were provided and Jonckheere-Terpstra tests for the ordered alternative were given. Results:In the intra-hemispheric comparison, left frontal coherence was increased in order of control, BPD I and schizophrenia. In the inter-hemispheric comparison, 1) inter-prefrontal coherence in BPD I was signifi- cantly higher than in normal controls, and 2) inter-prefrontal coherence in schizophrenia was significantly lower than in controls. Conclusion:These results suggest that 1) both schizophrenia and BPD I are diseases having the abnormality of neural circuit connectivity in both frontal and prefrontal lobes, and 2) the abnormality is more severe in schizophrenia than in BPD I. Furthermore, the data support that a common pathogenetic process may reside in both schizophrenia and BPD I.

  • PDF

지역사회복지실천에 있어서 기관간 연계의 효과성 평가 -'지역사회복지협의체' 사업의 참여자와 수혜자의 태도- (The Evaluation on the Effectiveness of Inter-Agencies in Community Welfare Practice -The Attitudes of Practitioners and Clients of Community Welfare Association-)

  • 함철호
    • 한국사회복지학
    • /
    • 제55권
    • /
    • pp.309-339
    • /
    • 2003
  • 본 연구는 2002년, 우리나라 14지역에서 시범사업으로 실시되었던 지역사회복지협의체 사업을 기관간 연계로 보고, 그 효과성에 대해 평가를 한 것이다. 연구에서 밝히고자 하는 문제는 두 가지이다. 하나는 기관간 연계로서 협의체 사업의 참여자들은 이 사업에 대해 긍정적으로 평가하는가, 부정적으로 평가하는가이고, 다른 하나는 서비스 제공자들간 연계에 의한 서비스에 대해 수혜자들은 어떠한 반응을 보이는가이다. 이 두 가지 질문에 대한 답을 찾고자, 한국보건사회연구원의 조사 자료를 재분석 하였다. 먼저 참여자들의 태도를 요약하면 다음과 같다. 즉, 의사소통에 대해 기관장들은 부정적인 평가를 하고, 실무자들은 긍정적인 평가를 하고 있다. 역할 수행에 대해 참여자들은 68.2%가 긍정적으로 평가하고 있으며, 77.8%가 협의체는 상시적으로 운영될 필요가 있다고 하고 있다. 수혜자들은 기관간 연계 서비스에 대해 전반적으로 긍정적으로 평가하고 있다. 그러나, 협의체 사업 전.후 비교에서, 가사서비스는 통계적으로 유의미한 차이가 있어 개선되었지만, 의료서비스 등 기타 서비스는 개선되지 않았다. 클라이언트만족문항(CSQ)척도 점수도 사전과 사후에 차이가 없었다.

  • PDF

Biomechanical Comparison of Inter-fragmentary Compression Pressures : Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation

  • Park, Jin-Woo;Kim, Kyoung-Tae;Sung, Joo-Kyung;Park, Seong-Hyun;Seong, Ki-Woong;Cho, Dae-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권5호
    • /
    • pp.498-503
    • /
    • 2017
  • Objective : The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. Methods : We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm long 4.0-mm cannulated lag screws (n=7 and n=10, respectively) after insertion into rigid polyurethane foam test blocks (Sawbones, Vashon, WA, USA). A washer load cell was placed between the two segments of test blocks to measure the compression force. Because the total length of each foam block was 42 mm, the 40-mm screws were embedded in the cancellous foam, while the 45-mm screws penetrated the denser cortical foam at the bottom. This enabled us to compare inter-fragmentary compression pressures as they are affected by the penetration of the apical dens tip by the screws. Results : The mean compression pressures of the 40- and 45-mm long cannulated lag screws were $50.48{\pm}1.20N$ and $53.88{\pm}1.02N$, respectively, which was not statistically significant (p=0.0551). The mean compression pressures of the 40-mm long Herbert screw was $52.82{\pm}2.17N$, and was not statistically significant compared with the 40-mm long cannulated lag screw (p=0.3679). However, 45-mm Herbert screw had significantly higher mean compression pressure ($60.68{\pm}2.03N$) than both the 45-mm cannulated lag screw and the 40-mm Herbert screw (p=0.0049 and p=0.0246, respectively). Conclusion : Our results showed that inter-fragmentary compression pressures of the Herbert screw were significantly increased when the screw tip penetrated the opposite dens cortical foam. This can support the generally recommended surgical technique that, in order to facilitate maximal reduction of the fracture gap using anterior odontoid screws, it is essential to penetrate the apical dens tip with the screw.

Comparison of Resonance Characteristics in FBAR Devices by Thermal Treatments

  • Mai Linh;Song Hae-il;Yoon Giwan
    • Journal of information and communication convergence engineering
    • /
    • 제3권3호
    • /
    • pp.137-141
    • /
    • 2005
  • The paper presents some methods to improve characteristics of film bulk acoustic resonator (FBAR) devices. The FBAR devices were fabricated on Bragg reflectors. Thermal treatments were done by sintering and/or annealing processes. The measurement showed a considerable improvement of return loss $(S_{11})$ and quality factor $(Q_{s/p}).$ These thermal treatment techniques seem very promising for enhancing FBAR resonance performance.