• Title/Summary/Keyword: intensity control

Search Result 2,292, Processing Time 0.031 seconds

Measured Intensity Control Method of a Phase-shift Measurement Based Laser Scanner by using APD Bias Voltage Characteristic (위상 검출 방식 레이저 스캐너의 APD bias 전압 특성을 이용한 검출신호세기 제어 방법)

  • Jang, Jun-Hwan;Yoon, Hee-Sun;Hwang, Sung-Ui;Park, Kyi-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.10
    • /
    • pp.1096-1100
    • /
    • 2012
  • In the phase-shift measurement method, the distance light travels can be obtained based on the phase difference between the reference signal and the measured signal. When the object having various colors is measured, the intensity of the measured signal much varies even at the same distance, and it causes different phase delay due to wide dynamic range input to a signal processing circuit. In this work, an measured intensity control method is proposed to solve this phase delay problem.

Power control of CiADS core with the intensity of the proton beam

  • Yin, Kai;Ma, Wenjing;Cui, Wenjuan;He, Zhiyong;Li, Xinxin;Dang, Shiwu;Yang, Feng;Guo, Yuhui;Duan, Limin;Li, Meng;Hou, Yikai
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1253-1260
    • /
    • 2022
  • This paper reports the control method for the core power of the China initiative Accelerator Driven System (CiADS) facility. In the CiADS facility, an intense external neutron source provided by a proton accelerator coupled to a spallation target is used to drive a sub-critical reactor. Without any control rod inside the sub-critical reactor, the core power is controlled by adjusting the proton beam intensity. In order to continuously change the beam intensity, an adjustable aperture is considered to be used at the Low Energy Beam Transport (LEBT) line of the accelerator. The aperture size is adjusted based on the Proportional Integral Derivative (PID) controllers, by comparing either the setting beam intensity or the setting core power with the measured value. To evaluate the proposed control method, a CiADS core model is built based on the point reactor kinetics model with six delayed neutron groups. The simulations based on the CiADS core model have indicated that the core power can be controlled stably by adjusting the aperture size. The response time in the adjustment of the core power depends mainly on the adjustment time of the beam intensity.

Accuracy Comparison Of Ground Control Points extracting from LIDAR Intensity (라이다의 반사강도에서 추출한 지상기준점의 정확도 비교)

  • Wie, Gwang-Jae;Choi, Yun-Soo;Oh, Jong-Min;Lee, Im-Pyung;Suh, Young-Woon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.4
    • /
    • pp.25-31
    • /
    • 2008
  • As we choose ground control points for aerial triangulation, we have a lot of problems in a mountain, a costal area, a desert, the foreshore etc because they don't have clear topography for control points and it spends a lot of cost and occurs problems of accuracy. In this study, we compare and analyze between ground control points from LiDAR intensity, digital map with ground control points from the field survey as doing AT each. As the result, the average error was ${\pm}1.02m$ from using LiDAR intensity, ${\pm}1.13m$ from using digital map. this result can present the control points from LiDAR intensity is 0.11m better than from digital map.

  • PDF

Optimal Flood Control Volume in the Irrigation Reservoir (관개저수지의 적정 홍수조절용량 설정방법)

  • 김태철;문종필;민진우;이훈구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.2
    • /
    • pp.81-91
    • /
    • 1998
  • Water level of irrigation reservoir during the flood season could be kept to a certain level, so called, flood control level by releasing the flood inflow in advance in order to reduce the peak discharge of next coming flood and the damage of inundation. Concept of restriction intensity of water supply was introduced to evaluate the influence of flood control volume on the irrigation water supply. Restriction intensity can be calculated by multiplying the ratio of restriction to the days of restriction which are obtained from the operation rule curve and daily water level of irrigation reservoir and it has the dimension of % day. The method of restriction intensity was applied to the Yedang irrigation reservoir with the observed data of 30 years to review whether the present flood control volume is reasonable or not, and suggest the optimal flood control volume, if possible.

  • PDF

One Idea on a Three Dimensional Measuring System Using Light Intensity Modulation

  • Fujimoto Ikumatsu;Cho In-Ho;Pak Jeong-Hyeon;Pyoun Young-Sik
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.130-136
    • /
    • 2005
  • A new optical digitizing system for determining the position of a cursor in three dimensions(3D) and an experimental device for its measurement are presented. A semi-passive system using light intensity modulation, a technology that is well known in radar ranging, is employed in order to overcome precision limitations imposed by background light. This system consists of a charge-coupled device camera placed before a rotating mirror and a light-emitting diode whose intensity is modulated. Using a Fresnel pattern for light modulation, it is verified that a substantial improvement of the signal to noise ratio is realized for the background noise and that a resolution of less than a single pixel can be achieved. This opens the doorway to the realization of high precision 3D digitized measurement. We further propose that a 3D position measurement with a monocular optical system can be realized by a numerical experiment if a linear-period modulated waveform is adopted as the light-modulating one.

Global Intensity Compensation using Mapping Table (맵핑 테이블을 이용한 전역 밝기 보상)

  • Oh, Sang-Jin;Lee, Ji-Hong;Ko, Yun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.15-17
    • /
    • 2006
  • This paper presents a new global intensity compensation method for extracting moving object in a visual surveillance system by compensating time variant intensity changes of background region. The method that compensates a little changes of intensity due to time variant illumination change and automatic gain control of camera is called global intensity compensation. The proposed method expresses global intensity change with a mapping table to describe complex form of intensity change while the previous method models this global intensity change with a simple function as a straight line. The proposed method builds the mapping table by calculating the cross histogram between two images and then by selecting an initial point for generating the mapping table by using Hough transform applied to the cross histogram image. Then starting from the initial point, the mapping table is generated according to the proposed algorithm based on the assumption that reflects the characteristic of global intensity change. Experimental results show that the proposed method makes the compensation error much smaller than the previous GIC method

  • PDF

Effects of Using Illite Warm Water Mats on Lactate, CRP and ACR Induced High Intensity Exercise in Adults (일라이트 온수매트 사용이 고강도 운동으로 유발된 성인의 젖산, CRP, ACR에 미치는 영향)

  • Choi, Youngjun;Kim, Hyunjun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.133-142
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effective recovery method of exercise-induced fatigue and muscle pain by comparing the effect of the use of illite hot mat product and general hot mat product on the recovery of muscle pain induced by high intensity exercise. Methods : To measure and analyze the changes in lactic acid, CRP, and ACR according to the high-intensity circuit training program, this study was conducted for the healthy adult men and women, who exercise st the K-region sports center. A total of 45 subjects were studied in 15 groups of 15 patients who received an illite hot-water mat recovery group (A group), 15 general hot-water mat recovery group (B group), and 15 control group (C group). The circuit training exercise program was conducted as a one-time exercise, and each exercise time consisted of 30 minutes of warm-up exercise, 5 minutes of main exercise, 20 minutes of clean-up exercise, and 5 minutes of strength exercise. The intensity setting was high intensity of subjective exercise intensity It carried out by setting to (14-16RPE). Results : Changes in Lactic Acid Concentration There was a significant difference in the lactic acid concentrations between the groups after the high intensity circuit training program (p <.05). The illite rest group (A) decreased 7.71 mmol / L and the control group decreased 4.03 mmol / L. Significantly decreased (p <.05). Changes in ACR Concentration. There was a significant difference in the ACR concentrations Significant differences were found in CRP and ACR during the recovery period after exercise. (p <.05), the elite rest group (A) decreased 2.47 mg / mmol, and the control group increased 1.63 mg / mmol. There was a significant difference (p <.05). Conclusion: The static rest on a heated mat after high-intensity exercise has an effect on changes in blood lactate and ACR levels.

The Effects of Exercise Intensity and Initial Timing on Functional Recovery after Sciatic Nerve Crush Injury in Rats

  • Cai, Junyan;Na, Sang-su;Hwangbo, Gak
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aim of this study was to investigate the effects of exercise intensity and initial timing on functional recovery following sciatic nerve injury in rats. METHODS: Total of 80 Sprague-Dawley rats was used and randomly divided 6 groups. Under deep anesthesia, the sciatic nerve was nipped by adapted hemostatic tweezers for 30 seconds and the injured nerve was transparent under naked eyes. Acute exercise groups was applied treadmill after sciatic nerve crush injury during 5days with three type intensity. Late exercise groups was also applied treadmill during 5 days with three type intensity after 5 days break. Values of sciatic functional index were measured and analyzed in each group after exercise period. RESULTS: The sciatic functional index values between control groups 1, acute low-intensity group, acute middle-intensity group in acute phase showed statistical significant (p<.05). The sciatic functional index values between control groups 2, late low-intensity group, late middle-intensity group and late high-intensity in late phase showed statistical significant (p<.05). The comparison in acute and late phase, sciatic functional index values of each low-intensity group and each high-intensity group showed statistical significant (p<.05). CONCLUSION: Whether at acute or late phase, treadmill exercise as a therapy obtained beneficial effects of functional recovery and exercise training at low speed is more beneficial effects on the recovery of motor function in acute phase.

A Study on the Control Characteristics of Line Scan Light Source for Machine Vision Line Scan Camera (머신 비전 라인 스캔 카메라를 위한 라인 스캔 광원의 제어 특성에 관한 연구)

  • Kim, Tae-Hwa;Lee, Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.371-381
    • /
    • 2021
  • A machine vision inspection system consists of a camera, optics, illumination, and image acquisition system. Especially a scanning system has to be made to measure a large inspection area. Therefore, a machine vision line scan camera needs a line scan light source. A line scan light source should have a high light intensity and a uniform intensity distribution. In this paper, an offset calibration and slope calibration methods are introduced to obtain a uniform light intensity profile. Offset calibration method is to remove the deviation of light intensity among channels through adding intensity difference. Slope calibration is to remove variation of light intensity slope according to the control step among channels through multiplying slope difference. We can obtain an improved light intensity profile through applying offset and slope calibration simultaneously. The proposed method can help to obtain clearer image with a high precision in a machine vision inspection system.

The Effects of Low-intensity Ultrasound on TGF-$\beta$1 Expression and Healing of Rat Femur Fracture (저강도 초음파가 흰쥐 대퇴골 골절치유와 TGF-$\beta$1의 발현에 미치는 영향)

  • Nam, Ki-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.4
    • /
    • pp.97-102
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate the effects of low intensity pulsed ultrasound on TGF-$\beta$1 expression and healing of rat femur penetrating fractures. Methods: Rats were anesthetized with ketamine and xylazine. Using aseptic technique, we exposed the lateral right femoral diaphysis with removal of the periosteum. We made one hole along its long axis with an electrically-driven 1.8 mm diameter drill bit. Postoperatively, rats were divided into two groups (a control group, n=15; an experimental group, n=15). The experimental group was treated with low intensity pulsed ultrasound (pulse rate: 1:4, 0.5 W/$cm^2$, 10 minutes, 1 time per day) for 3 weeks. The control group was treated with sham ultrasound (with the US unit turned off). Results: The experimental group achieved more callus formation and TGF-$\beta$1 expression than the control group at the $7^{th}$, $14^{th}$ and $21^{st}$ days after low intensity pulsed ultrasound treatment. Conclusion: This study suggests that low intensity pulsed ultrasound facilitates bone fracture repair, possibly via increased TGF-$\beta$1 expression.

  • PDF