• 제목/요약/키워드: integrated membrane system

검색결과 67건 처리시간 0.025초

Treatment of Highly Organic, Brackish Surface Water by Integrated Membrane Systems

  • Lee, Jin-Woo;James Taylor;Seungkwan Hong
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.25-28
    • /
    • 2004
  • In recent years, membranes have become fully or partially integrated into all facilities that produce drinking water since membrane processes can resolve technically complex and, at times, conflicting requirements related to compliance with multi-contaminant regulations. However, NF or RO technologies are hydraulically limited by the feed water quality that causes the fouling in a membrane system. In particular, NF or RO systems involved in surface water treatment generally require extensive pretreatment for controlling membrane fouling.(omitted)

  • PDF

MEMBRANE CONTACTORS IN INTEGRATED SYSTEMS

  • Criscuoli, Alessandra;Drioli, Enrico
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 The 7th Summer Workshop of the Membrane Society of Korea
    • /
    • pp.52-54
    • /
    • 1999
  • In the present work, results of simulation studies carried out for the water carbonation process are presented and compared with experimental data obtained for the same system. Furthermore, the use of membrane contactors in integrated membrane operations is proposed and discussed as a mean to enhance the performance of processes.

  • PDF

멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구 (A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank)

  • 김청균
    • 한국가스학회지
    • /
    • 제14권2호
    • /
    • pp.40-46
    • /
    • 2010
  • 본 연구에서는 기존 멤브레인식 LNG 저장탱크의 측정장치와 안전장치에 대한 고찰과 분석을 통해 초대형 멤브레인 식 LNG 저장탱크에 적합한 새로운 통합제어안전관리시스템 연구를 수행하고자 한다. 통합제어안전관리시스템은 기존에 단수로 설치한 압력계를 추가하고, 기존의 LNG 저장탱크에는 없는 변위센서와 하중센서를 내부탱크와 예응력 콘크리트 구조물 사이를 관통하는 강재앵커에 새로이 설치함으로써 초대형 LNG 저장탱크의 안전성과 효율성을 향상시키는 역할을 담당할 것으로 예상된다. 변위센서와 하중센서는 멤브레인 패널의 파손여부, 내부탱크로부터 발생된 LNG 누설의 단서를 제공하게 될 것이다. 기존의 누설센서는 내부탱크 뒤편의 보냉재 공간에 설치한 온도센서에 의해 LNG 누설이라는 신호를 보낼 때까지도 멤브레인 패널의 손상에 관련된 적절한 정보를 제공하지 못할 수 있다. 결국 새로운 통합제어안전관리시스템은 온도, 압력, 변위량, 하중, LNG의 밀도 데이터를 수집하고 분석하기 위한 것으로, 탱크시스템의 안전성과 내부탱크의 누설을 제어하기 위한 시스템이다. 또한, 디지털 데이터는 멤브레인 패널의 안전성에 관련된 변위량과 하중, LNG의 액위와 밀도, 쿨다운 공정, 누설, 압력 등을 제어하기 위해 측정된다.

연료전지 자동차용 복합형 가습시스템에 관한 연구 (An Integrated Humidification System for a Fuel Cell Vehicle)

  • 김현유;권혁률;서상훈;박용선;안병기
    • 한국수소및신에너지학회논문집
    • /
    • 제21권6호
    • /
    • pp.547-552
    • /
    • 2010
  • In this study, we suggested an integrated humidification system for a fuel cell electric vehicle (FCEV) as an efficient method of humidification under the various driving condition of the fuel cell vehicle and system. It is improving air humidification system combined the existing membrane humidifier and water injection. As a result, we verified it through experiments and the vehicle test and could get a result of improvement of humidification performance. The results show that an integrated humidification system is a useful method for FCEV applications.

A Polymer-based Capacitive Air Flow Sensor with a Readout IC and a Temperature Sensor

  • Kim, Wonhyo;Lee, Hyugman;Lee, Kook-Nyeong;Kim, Kunnyun
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.1-6
    • /
    • 2019
  • This paper presents an air flow sensor (AFS) based on a polymer thin film. This AFS primarily consists of a polymer membrane attached to a metal-patterned glass substrate and a temperature-sensing element composed of NiCr. These two components were integrated on a single glass substrate. The AFS measures changes in capacitance caused by deformation of the polymer membrane based on the air flow and simultaneously detects the temperature of the surrounding environment. A readout integrated circuit (ROIC) was also fabricated for signal processing, and an ROIC chip, 1.8 mm by 1.9 mm in size, was packaged with an AFS in the form of a system-in-package module. The total size of the AFS is 1 by 1 cm, and the diameter and thickness of the circular-shaped polymer membrane are 4 mm and $15{\mu}m$, respectively. The rate of change of the capacitance is approximately 11.2% for air flows ranging between 0 and 40 m/s.

이산화탄소 분리를 위한 중공사막 모듈에서의 물질전달 거동 (On the Mass Transfer Behaviors in Hollcw-Fiber Membrane Modules for $CO_2$ Separation)

  • 전명석;김영목;이규호
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1994년도 춘계 총회 및 학술발표회
    • /
    • pp.51-52
    • /
    • 1994
  • High permeability, selectivity and stability are the basic properties also required for membrane gas separations. The $CO_2$ separation by liquid membranes has been developed as a new technique to improve the permeability and selectivity of polymeric membranes. Sirkar et al.(1) have atlempted the hollow-fiber contained liquid membrane technique under four different operational modes, and permeation models have been proposed for all modes. Compared to a conventional liquid membrane, the diffusional resistance decreased by the work of Teramoto et al.(2), who referred to a moving liquid membrane. Recently, Shelekhin and Beckman (3) considered the possibility of combining absorption and membrane separation processes in one integrated system called a membrane absorber. Their analysis could be predicted effectively the performance of flat sheet membrane, however, there are restrictions for considering a flow effect. The gas absorption rate is determined by both an interfacial area and a mass transfer coefficient. It can be easily understood that although the mass transfer coefficients in hollow fiber modules are smaller than in conventional contactors, the substantial increase of the interfacial area can result in a more efficient absorber (4). In order to predict a performance in the general system of hollow-fiber membrane absorber, a gas-liquid mass transfor should be investigated inevitably. The influence of liquid velocity on both a mass transfer and a performance will be described, and then compared with experimental results. A present study is attempted to provide the fundamentals for understanding aspects of promising a hollow-fiber membrane absorber.

  • PDF

Use of laminar flow water storage tank (LFWS) to mitigate the membrane fouling for reuse of wastewater from wafer processes

  • Sun, Darren Delai;Wu, You
    • Membrane and Water Treatment
    • /
    • 제3권4호
    • /
    • pp.221-230
    • /
    • 2012
  • This study employed the modified fouling index (MFI) to determine the performance of a two-step recycling system - a membrane filtration integrated laminar flow water storage (LFWS) tank followed by an ion exchange process to reclaim ultrapure water (UPW) from the wastewater generated from semiconductor wafer backgrinding and sawing processes. The first step consisted of the utilization of either ultrafiltration (UF) or nanofiltration (NF) membranes to remove solids in the wastewater where the second step consisted of an ion exchanger to further purify the filtrate. The system was able to produce high purity water in a continuous operating mode. However, higher recycling cost could be incurred due to membrane fouling. The feed wastewater used for this study contained high concentration of fine particles with low organic and ionic contents, hence membrane fouling was mainly attributed to particulate deposition and cake formation. Based on the MFI results, a LFWS tank that was equipped with a turbulence reducer with a pair of auto-valves was developed and found effective in minimizing fouling by discharging concentrated wastewater prior to any membrane filtration. By comparing flux behaviors of the improved system with the conventional system, the former maintained a high flux than the latter at the end of the experiment.

안정적 유출수질의 연속 하수처리를 위한 혐기성 멤브레인 필터와 통합된 미생물연료전지의 성능 평가 (Performance of Microbial Fuel Cell Integrated with Anaerobic Membrane Filter for Continuous Sewage Treatment with Stable Effluent Quality)

  • 이윤희;어성욱
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.808-812
    • /
    • 2013
  • A new type of microbial fuel cell (MFC) with anaerobic membrane filter was designed to produce bioelectricity and to treat domestic sewage at relatively high organic loading rate (OLR) of $6.25kgCOD/m^3/day$ and short hydraulic retention time (HRT) of 1.9 h. A following aeration system was applied to ensure effluent water quality in continuous operation. Glucose was supplemented to increase the influent concentration of domestic sewage. Influent substrate of 95% was removed via the MFC and following aeration system and the corresponding maximum power density was $25.6mW/m^3$. External resistor of $200{\Omega}$ and air-cathode system contributed better MFC performance comparing to $2000{\Omega}$ and dissolved oxygen as a catholyte.