• Title/Summary/Keyword: insulation system

Search Result 1,387, Processing Time 0.024 seconds

Insulation Performance Evaluation through Insulation Test and Transient Heat Transfer Analysis of Cryogenic Common Bulkhead Propellant Tanks (극저온 공통격벽 추진제 탱크의 단열 시험과 과도 열전달 해석을 통한 단열 성능 평가)

  • Yeji Kim;Gyeong-Han Lee;Sang Min Choi;Sang-Woo Kim;Soo-Yong Lee
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.4
    • /
    • pp.109-116
    • /
    • 2024
  • The validity of the analysis results was confirmed based on the insulation test results, and the vaporization mass generated in the common bulkhead was calculated to evaluate the common bulkhead propellant tank's insulation performance. The analysis results were validated by comparing the transient heat transfer analysis with the insulation test results. A transient heat transfer analysis was subsequently conducted on the common bulkhead propellant tank, considering the internal heat conduction in the propellant tank and natural convection heat transfer due to the outside air. This analysis extracted the heat flux generated in the common bulkhead and quantified the vaporization mass, a key indicator of insulation performance. Consequently, the vaporization mass was calculated at 0.09 kg, below the insulation design standard of 0.12 kg for the common bulkhead propellant tank, confirming it meets the insulation performance standard.

A Study on the domestic power plant roof waterproofing system & insulation efficiency (국내 발전소 지붕방수설계 시스템 및 단열 성능에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.1
    • /
    • pp.33-42
    • /
    • 2011
  • As the development of construction technology and new materials, building requirements has been varied gadually. Comfortable environment and serviceability of production activity and energy conservation are being dealt with very seriously. Recently localization of engineering technology of Power Plant, however, construction materials and domestic technology are being developed forcingly. According to above topics this thes is going to study roof waterproofing, thermal insulation and evaluate adiabatic performance and evaluation of properties of waterproofing materials and energy conservation. The results of studying and evaluating of roof waterproofing, thermal insulation and adiabatic performance of Power Plant are as follows. 1. Sheet waterproofing method is better than that of asphalt waterproofing method in that adaptability of wearhertight, thermal resistant, contraction and expansion. 2. It is required to replace polyurethane or ethylene used as thermal insulation with rock wool which is noncombustible materials. 3. It is recommended to usd outer insulation method than inner insulation method due to superioty of outer insulation method. Efficiency of insulation materials used in power plant is generally good except perlite mortar used in the power plant(YGN 1-2, GRI 1-2).

Partialt Discharge Measurement Techniques for Diagnosis of Surface Aging on Organic Insulation (고체 합성수지절연체와 표면노화 진단기술로서의 부분방전 측정평가기술에 대하여)

  • 박완기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.50-56
    • /
    • 1994
  • Partial discharge on organic insulation surfaces are an important sauce of aging. Furthermore the modern PD measurement technigues are rapid developed as quality control and diagnostic tests to determine the fitness for use of HV equipment employing sol id electrical insulation. This paper deals with theory of conventional PD measurement and new tendency of technical development on PD measurements und evaluations. Finally the Measuring system used for diagnosing the surface aging on the organic insulation at High Voltage Laboratory of Technical University of Darmstadt in Germany is presented.

  • PDF

The Performance of Insulation of Noise by Air between Floors According to Structure Systems of Apartment (공동주택 구조형태별 층간 공기전달음 차단 성능)

  • Lee, Byung-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1152-1155
    • /
    • 2007
  • Lately concerns about structure have been increased by advantages of floor impact noise, poilitical induction and changeability. Hence, Flat Plate Structure has been constructed increasingly. This study shows the comparison of the performance of sound insulation of Flat Plate Structure System and the existing Wall Structure. For this study, taking the same level organization of Daelim Architectural Environmental Research Center, I found the performance of sound insulation between the upper and lower floors about Wall Structure and Flat Plate Structure. Consequently, the performance of sound insulation between upper and lower floors of Flat Plate Structure was 3-5dB higher was approximately 3-5dB higher than one of Wall Structure. Especially, the performance of sound insulation on the upper floor was 1-3dB higher than on the lower floor. In addition, as the result of comparing radiation sound which radiates from the wall of lower floors with each structure system, Flat Plate Structure was about 4dB higher with Rw than Wall Structure. As we see totally, the performance of sound insulation of Flat Plate Structure is highter than one of the Wall Structure. It is 3-5dB higher and the main reason for this result depends on the existence of the wall which can radiate sound and nonexistence.

  • PDF

Analysis of airborne sound insulation performance by the experiment using small size specimen (축소시편 실험을 통한 공기전달음 차단성능 분석)

  • Kim, Hang;Park, Hyeon Ku;Goo, Hee Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • The residents' demand for the comfortable life is promoting development of wall and window which has high sound insulation performance. To develop wall system, various aspects should be considered on the environment, material, construction and structure. Especially focusing on the acoustical view, the economical solution is one of the most critical point. Recently the interest on the partition wall is being increased, because it is useful for the Rahmen type apartment which is considered as an alternative to reduce floor impact sound. This study examines simplified measurement method of airborne sound insulation applied small size specimen, in order to save money to be used for the standard specimen then to promote the development process. The results showed that the simplified method could be effective for the wall system the sound insulation performance upto Rw 50 dB, and for the judgement of rank order of sound insulation performance of the similar wall type while developing.

Study on High Performance Building Envelope for raising Building Energy Rating (건물에너지효율등급향상을 위한 고효율 건물외피 성능 연구)

  • Hyun, Jong-Hun;Hong, Sung-Hee;Park, Hyo-Soon;Choi, Moo-Hyuck
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.801-806
    • /
    • 2008
  • The best plan is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, influence, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case1,2) and vacuum or triple glazing can retrieves the investment with $120 and $$140{\sim}150$ per barrel each.

  • PDF

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation (완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구)

  • Ahn, Jae-Won;Jun, Myoung-Hoon;Lee, Bum-Sik;Lee, Do-Heun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF

Evaluation and Analysis of Building Energy Rating System Accroding to Insulation Performance of Building Envelope in Regional and Building Form of Apartment House (지역 및 주동형태별 공동주택 외피 단열 성능에 따른 건물에너지효율등급 평가 및 분석)

  • Kim, Min-Kyu;Park, Hyu-Soon;Song, Kyoo-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.49-54
    • /
    • 2013
  • In field of apartment housing currently, insulation technology is the most effective way because it is common to improve the thermal performance, therefore, it is contributed to energy saving as several regional insulation standards and legal mandate method. In addition, by applying of building energy efficiency rating certification system, it has inspired voluntary energy conservation commitment for the building owner or facility manager by making a plan to evaluate and verify building energy performance. However, these circumstances are not enough to acquire a grade 2 of higher information. Therefore, in this study, we analyzed the impact of building energy efficiency rating and confirmed reduction ratio compared to the standard housing on the basis of recent our nation building law when we had changed the shape of windows and wall insulation performance and shapes of housing.

Defect detection of vacuum insulation panel using image analysis based on corner feature detection (코너 특정점 기반의 영상분석을 활용한 진공단열재 결함 검출)

  • Kim, Beom-Soo;Yang, Jeonghyeon;Kim, Yeonwon
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.398-402
    • /
    • 2022
  • Vacuum Insulation Panel (VIP) is an high energy efficient insulation system that facilitate slim but high insulation performance, based on based on a porous core material evacuated and encapsulated in a multi-barrier envelope. Although VIP has been on the market for decades now, it wasn't until recently that efforts have been initiated to propose a standard on aging testing. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time. It is hard to visually determine at an early stage. Recently, a method of analyzing the damage on the a material surface by applying image processing technology has been widely used. These techniques provide fast and accurate data with a non-destructive way. In this study, the surface VIP images were analyzed using the Harris corner detection algorithm. As a result, 171,333 corner points in the normal packaging were detected, whereas 32,895 of the defective packaging, which were less than the normal packaging. were detected. These results are considered to provide meaningful information for the determination of VIP condition.