• Title/요약/키워드: insulation performance

검색결과 1,184건 처리시간 0.032초

A Study on the Sound Insulation performance Survey Estimation in Apartment house (공동주택의 소음성능 실측평가에 관한 연구)

  • 함진식;박명길
    • Journal of the Korean housing association
    • /
    • 제12권4호
    • /
    • pp.219-226
    • /
    • 2001
  • This treatise measures and estimate sound insulation performance of apartment house. Sound insulation performance measured to the floor and wall. Measurement object is apartment occupancy ago of 100㎡ scale built to higher story in Taegu city. Floor Slav's light impact sound level interception performance interacted by benevolent person who carrying out availability of finish material important. Floor Slav's heavy impact sound level interception performance amounted estimation by being good more or less then light impact sound level interception performance. Because sound insulation performance of partition between adjoined generation is gad seldom, privacy infringement becomes anticipation. There was discussion about these results, and presented various kinds future research task to prove sound insulation performance of apartment house.

  • PDF

A Study on the Thermal Characteristics of the Vacuum Jacket Valve for Transporting Liquefied Hydrogen According to the Degree of Vacuum (액화수소 수송용 진공자켓 밸브의 진공도에 따른 열적특성에 대한 연구)

  • OH, SEUNG JUN;JEON, KYUNG SOOK;YOON, JEONG HWAN;CHOI, JEONGJU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제32권6호
    • /
    • pp.585-591
    • /
    • 2021
  • Liquefied hydrogen have advantage which reduces the volume by about 800 times or more compared to hydrogen gas, so it is possible to increase the storage density. However, liquefied hydrogen produced by cryogenic cooling of 20 K or less at normal pressure has a problem of maximizing the insulation effect that blocks heat introduced from the outside. Representative insulation technologies include vacuum insulation and multi-layer insulation materials and in general, heat blocking is attempted by combining insulation technologies. Therefore, in this study, the pressure of the internal vacuum layer was changed to 10-1, 10-2, 10-3 and 10-4 Torr to confirm the thermal insulation performance of the vacuum jacket valve for transporting liquefied hydrogen. As a result, it was confirmed that the insulation performance improved as the degree of vacuum increased.

Performance of Heat Insulation Capability of the Concrete Applying Light Heat Generating Sheet (광발열 단열시트를 적용한콘크리트의 특성 )

  • Lee, Hyeon-Jik;Baek, Sung-Jin;Lee, Seung-Min;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.169-170
    • /
    • 2023
  • In this study, light-heat generating materials were produced in two ways, and the performance of two light-generating insulation sheets was reviewed. As a result of the experiment, it was possible to confirm the improved heating performance of the light heating insulation sheet compared to the existing bubble sheet. The light heat insulation sheet (b) showed improved thermal properties compared to the existing bubble sheet, and it is believed that the temperature has increased due to the combined effect of initial hydration heat and heat generation after installation. In future studies additional experiments are needed to compensate for the insufficient insulation performance due to the single bubble sheet through the double bubble sheet and to adjust the amount of light-generating materials added as a consideration of the optimal heat-generating effect of the light-generating insulation sheet (b).

  • PDF

Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame (트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가)

  • Song, Jin-Hee;Lee, Dong-Yun;Shin, Dong-Il;Jun, Hyun-Do;Park, Cheol-Yong;Kim, Sang-Kyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • 제35권6호
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.

Insulation Method and Performance Evaluation for Fastening Unit of ALC Pannel-Curtain wall (ALC 패널 커튼월의 패스닝 유닛의 단열 방법과 성능 평가)

  • Kim, Bongl-Joo;Kim, Kyeong-A;Park, Je-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.107-110
    • /
    • 2011
  • In this study is to improve insulation performance that are the most weak insulation part of fastening unit of the curtain wall. It was produced that thought out to minimize mullion and connecting part, and evaluated performance that make a layer of insulation in the middle by using vibration-proof rubber or silicon. Vibration-proof rubber insulation is 2.6℃~4.0℃ higher and silicon insulation is 2.4℃ higher than non-insulation. Therefore the insulating layer of fastening unit is necessary.

  • PDF

Thermal Performance of Building Envelope with Transparent Insulation Wall (건물 외피 투과형단열 벽체의 열성능 해석 연구)

  • Jang, Yong-Sung;Yoon, Yong-Jin;Park, Hyo-Soon
    • KIEAE Journal
    • /
    • 제5권1호
    • /
    • pp.27-33
    • /
    • 2005
  • Global efforts have made to reduce energy consumption and $CO_2$ gas emission. One of the weakest parts for energy loss through the whole building components is building envelopes. Lots of technologies to increase the thermal performance of building envelopes have been introduced in recent year. Transparent Insulation Wall(TIW) is a new technology for building insulation and has been function both solar transmittance and thermal insulation. A mathematical model of a Transparent Insulation Wall equipped with south wall was proposed in order to predict thermal performance under varying climates(summer and winter). Unsteady state heat transfer equations were set up using an energy balance equation and solved using Gauss-Seidel iteration solution procedure. The thermal performance of the TIW determined from a wall surface and air layer temperature, non-airconditioned room temperature and air conditioning load. As a result, this numerical study shows that the TIW is effective in an air conditioning load reduction. Further experimental study is required to establish complete TIW system.

The Thermal Performance of Building Insulation Materials According to Long-Term Aging (건축용 단열재의 장기 경시변화에 따른 열성능 특성)

  • Choi, Bo-Hye;Kang, Jae-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제25권11호
    • /
    • pp.617-623
    • /
    • 2013
  • This study is to draw thermal property data during long-term aging, by testing the thermal conductivity of building insulation materials in Korea. The thermal resistance of extruded insulation within 3 days from manufacture performed well over the KS Standard. After 50 to 110 days, however, the thermal performance had deteriorated to the level of the KS standard. Eventually, after 4,000 days, the insulation performance had deteriorated to about 25.4~41.8% of the initial performance. Therefore, this research will be utilized as a reference for thermal properties during long-term aging, in order to improve standards and regulations related to building insulation materials.

Sound Insulation Performance of the Side Layered Panels in the Next Generation High Speed Train (차세대 고속철도 차량 측면 적층재의 차음성능)

  • Lee, Joong-Hyeok;Lee, Ho-Jin;Park, In-Seok;Kim, Seock-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.457-462
    • /
    • 2011
  • The sidewall of the HEMU-400x consists of two parts. One is the multi-layered structure including aluminium extruded panel and the other is the double glazed window. When the train runs in a tunnel, the equivalent sound insulation performance of the side wall significantly influences the internal noise levels. In aspect of the sound insulation strategy, it is important to make two parts have similar performance. In this study, the intensity sound transmission loss (ITL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance of the two parts in respect of the weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy is investigated to reduce the interior noise.

  • PDF

Insulation Performance Estimation of Main Relays by Partial Discharges (부분방전에 의한 주계전기의 절연성능 평가)

  • Kil, Gyung-Suk;Kim, Il-Kwon;Park, Dae-Won;Song, Jae-Yong;Lee, Gang-Won;Cho, Eun-Je
    • Journal of the Korean Society for Railway
    • /
    • 제10권4호
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

A Study on the Sound Insulation Performance of the Composite Panel for Railroad Vehicle (철도차량용 복합 내장 패널의 차음성능에 관한 연구)

  • 김봉기;김재승;황병선;이상진
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.182-187
    • /
    • 2002
  • Since most of main noise sources of the railroad vehicle are transmitted to the passenger's ear through the vibration of the panel, the insulation performance of the panels should be high enough to protect the passengers from the noisy environment. Specifically, the composite materials which are generally used for reducing the weight of the vehicle compartment have the low insulation performance, noise control actions should be taken appropriately by considering the insulation performance of the panels. In this study, the insulation performances of the inner/outer panels were evaluated and the contribution of the aluminum door was estimated compared to the composite panels. The results can furnish an indepth understanding of the insulation characteristics of the panel of railroad vehicle.

  • PDF