열적 열화 온도 변화에 따른 PAI 에나멜 각형코일의 절연 파괴 주파수 특성 (Insulation Breakdown Frequency Properties of PAI Enamelled Rectangular Coils According to Thermal Deterioration Temperature Variation)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.829-834
    • /
    • 2016
  • Coil specimens were prepared by continuous coating on a copper wire with flexible PAI (polyamideimide) and PAI/nanosilica (5 wt%) varnish and thermally aged at 150, 200 and $250^{\circ}C$ for 5, 10 and 15 days, respectively. AC insulation breakdown voltage was investigated under inverter surge condition at 60 Hz and 1,000 Hz and insulation breakdown voltage decreased with increasing aging temperature and aging time at each 60 and 1,000 Hz.

6.6 kV 전동기 고정자 권선의 절연진단과 절연내력 평가 (Estimation of Insulation Diagnosis and Dielectric Strength in 6.6 kV Motor Stator Windings)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.780-785
    • /
    • 2014
  • To assess the deterioration condition of stator insulation, diagnostic and AC dielectric strength tests were performed on five high voltage (HV) motors (2,000 HP, 6.6 kV) for boiler feed-water pump (BFP). Two HV motors for BFP were installed per unit. Following the long term rewinding program, the diagnostic test was performed on five 6.6 kV motors during the planning maintenance period. After completing diagnostic test, AC dielectric strength test was done on the stator windings of HV motors. The AC dielectric strength test was conducted at 15 kV for one minute. Dielectric strength test and diagnostics test results confirmed that the stator insulation was judged to be in serviceable condition in the five 6.6 kV motors.

에폭시/고무 계면에서의 결함에 따른 부분방전 특성 (Chracteristics of Partial Discharge Patterns Subjected to Different Defects at the Epoxy/Rubber Interface)

  • 김동욱;김정년;백주흠
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.199-204
    • /
    • 2002
  • In order to recognize the deterioration of insulation system by partial discharge (PD), the characteristics of PD patterns which are occurring at the interface between epoxy and rubber materials in extra high voltage cable joints, have been investigated. The artificial defects such as voids, metal particles, insulation fiber and water impregnated insulation fiber are planted between the interfaces. A high frequency partial discharge detection system was used for measuring PD signals. An analysis of the PD patterns is focused on the shape of PD pattern, phase, width and time-dependence for each artificial defect. The PD Patterns in each defect show the different behaviors and it is suggested that the precise discrimination of PD patterns could be used for the diagnosis of deterioration in the insulation systems.

절연진단 데이타베이스 프로그램을 이용한 고압전동기 열화 분석 (Deterioration Analysis for High Voltage Motor Using Insulation Diagnostic Database Program)

  • 공태식;김희동;이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.100-102
    • /
    • 2005
  • This paper is purpose to introduce the database management program of insulation tests for high voltage rotating machines. KEPRI has carried out insulation tests for high voltage equipment since 1998, the number of tests grow larger every year. It is difficult to manage the numerous test results, so we developed the insulation diagnostic database program. The features of this program are an easy-search test result and making a graph of AC, tan${\Delta}$ test. the most useful function is the trend management. Using the trend function, we can find the aging deterioration for high voltage machines easily.

  • PDF

가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구 (A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis)

  • 김아름;곽병섭;전태현;박현주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

운전 중인 고전압 케이블의 절연저항 측정 및 수명평가장치의 개발 (Development of Equipment to Measure Insulation Resistance and Evaluate the Lifetime of High-voltage Cable in Operation)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.237-242
    • /
    • 2014
  • 이 논문은 발전소에서 설치 운전 중인 6.6kV 고전압 케이블이 시간에 따라 성능이 악화되는 현상의 추세를 결정하는 수명지수를 파악하기 위한 논문이다. 우리가 연구한 케이블 시스템은 설치 후 13 년 동안 운전하고 있다. 삼상전력에 연결되는 변류기, 온도센서 LPF 등을 이용한 측정장치를 개발하여 케이블의 절연저항 변화 특성을 해석하였다. 고전압 22kV 케이블과 비교하면 절연체의 두께가 더 두껍기 때문에 특성을 다르게 나타낸다. 동작시간이 경과함에 따라, 절연저항이 계속 감소하지 않음을 확인 하였다. 일정한 값으로 감소하다가 더 이상 감소하지 않고 상하진동하는 특성을 나타내었다. 지난 13 년 동안의 열화과정을 파악할 수 없었지만, 시스템이 안정 상태에서 동작을 하였다는 사실은 열화가 아직 발생하지 않았다는 의미이다. 이런 경우에는, 수명지수를 예측할 수 없기 때문에 케이블의 수명을 정량적으로 예측할 수 없음을 확인하였다.

고전력 활선 XLPE 케이블의 열화를 측정하기 위한 판정기준의 적용 및 절연상태 판정 (Application of Judgement Criteria to Measure Deterioration and to Judge Insulation Resistance in High-Power Live XLPE Cables)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.239-244
    • /
    • 2017
  • 전력 수요는 매년 증가추세에 있으며, 이에 따라 발전소에서 동작하는 모든 장비들과 대용량의 장거리 전력수송을 위한 장비들은 신뢰할 수 있는 수준에서 완전한 상태로 동작하여야 한다. 발전소에서 생산한 고전압 전력을 전달하기 위해 사용하는 케이블은 주로 6.6 kV XLPE 케이블(또는 CV케이블)이다. 제작 기술, 설치환경 및 사용조건에 다르겠지만, 케이블은 동작함과 동시에 열화과정이 진행된다. 접속재의 경우, 제조 결함이나 공사 결함이 있는 경우 대체로 동작 후 약 3 년 내에 고장을 일으키며, 그렇지 않는 경우 수명이 20-30 년을 지속하는 경우가 많다. 우리는 케이블의 열화 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국서부발전주식회사(Korea Western Power Co. Ltd.)에 설치하였다. 우리는 이 논문에서 케이블의 열화 판정의 기준을 설정하고, 기준에 따른 열화정도를 판정하고, 케이블의 대체여부를 결정함으로써 발전소에서 설치된 활선 케이블의 동작 상태를 감시한 결과와 케이블을 구성하고 있는 절연체와 방식층이 절연저항 특성에 미치는 영향 및 케이블의 동작에 미치는 영향을 연구한 결과를 제시한다.

펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정 (Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm)

  • 정성인
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권5호
    • /
    • pp.111-116
    • /
    • 2022
  • 전동기 소손의 원인으로는 과부하, 결상, 구속, 층간단락, 권선의 지락, 순간과전압의 유입, 회전자가 고정자에 닿는 경우 등 절연파괴로 이어져 고장 또는 전기 사고로 이어지고 있다. 따라서 기기 고장은 기기의 보수/수리에 필요한 비용에 의한 손실뿐만 아니라, 전동기가 포함된 공정 자체를 멈추기 때문에 공정 정지에 따른 생산성 저하에 의한 막대한 경제적 손실을 초래한다. 전동기의 고장을 진단하기 위한 현재의 기술의 수준은 진동, 열, 전력분석 방식을 이용하고 있지만, 고장에 따른 상당 부분의 시간이 진행되어야 문제점을 분석할 수 있는 한계점을 가지고 있다. 따라서 본 논문에서는 이러한 문제점을 해결하고자 DC AMP 신호를 이용하여 절연저항을 측정하는 장치 및 알고리즘을 산업용 전동기에 적용하여 절연저항 상태값을 추종하여 기존방식에서 해결되지 못한 전동기의 열화 및 고장 진단을 제안한다.

Corona 방전에 의한 Polyethylene의 표면열화현상 (Surface Deterioration Phenomena in Polyethylene under Corona Discharge)

  • 성영권;송진수;민남기
    • 전기의세계
    • /
    • 제24권5호
    • /
    • pp.82-90
    • /
    • 1975
  • This study investigated the deterioration phenomena of the Polyethylene surface contaminated with organic(Saccharose) or inorganic(NaCl) matters through electrical and optical experiments. And also these experimental results relatively well coincided with which was treated by theoretical process. On the electrical experiment, relation between electric field intensity in corona discharge and time reached to the breakdown, and relation between total amount of charges discharged and increment of applied voltage were investigated. On the optical experiment, discharge time dependence of surface deterioration rate and process of surface deterioration in the X-ray diffraction pattern were investigated. It was concluded that chemical effects by the corona discharge deteriorated insulation characteristics of Polyethylene surface.

  • PDF

인공적 침상보이드의 갭길이 변화에 따른 음향방출 특성 (Characteristics of acoustic emission according to variation gap length on artificial needle shape void)

  • 박재준;김상남
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권4호
    • /
    • pp.495-503
    • /
    • 1995
  • As lengthen gap leng of artificial needle shape void 0.24.rarw.1.5[mm]), the amplitude of AE(Acoustic Emission) pulses was enlarged and number of pulses be generated was few. The longer gap length of void, the shorter breakdown time. As a result of this, I found that existen of void in insulation mate was fatal deterioration of insulation. According to phase angle of applied voltage, time being void was scattered largely in region of phase angle of pulses of origination in phase angle of applied voltage. The result will be used to analysis of void diagnosis.

  • PDF