• 제목/요약/키워드: insulating performance

검색결과 240건 처리시간 0.022초

Copper Particle Effect on the Breakdown Strength of Insulating Oil at Combined AC and DC Voltage

  • Wang, You-Yuan;Li, Yuan-Long;Wei, Chao;Zhang, Jing;Li, Xi
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.865-873
    • /
    • 2017
  • Converter transformer is the key equipment of high voltage direct current transmission system. The solid suspending particles originating from the process of installation and operation of converter transformer have significant influence on the insulation performance of transformer oil, especially in presence of DC component in applied voltage. Under high electric field, the particles easily lead to partial discharge and breakdown of insulating oil. This paper investigated copper particle effect on the breakdown voltage of transformer oil at combined AC and DC voltage. A simulation model with single copper particle was established to interpret the particle effect on the breakdown strength of insulating oil. The experimental and simulation results showed that the particles distort the electric field. The breakdown voltage of insulating oil contaminated with copper particle decreases with the increase of particle number, and the breakdown voltage and the logarithm of particle number approximately satisfy the linear relationship. With the increase of the DC component in applied voltage, the breakdown voltage of contaminated insulating oil decreases. The simulation results show that the particle collides with the electrode more frequently with more DC component contained in the applied voltage, which will trigger more discharge and decrease the breakdown voltage of insulating oil.

UV-Vis 분광분석에 의한 전기변압기 내 절연지 열화도 측정 (Application of UV-Vis Spectroscopic Analysis for Transformer Insulating Paper Degradation)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제35권3호
    • /
    • pp.151-157
    • /
    • 2019
  • Insulated oil degradation produces charged by-products, such as acids and hydro-peroxides, which tend to reduce the insulating properties of the oil. In this study, UV-vis spectroscopy measurement technology is developed and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate its ability to monitor the degradation of electrical insulating paper. The degradation characteristics of the insulating paper are appropriately represented through various types of measurement methods, such as the Tan (delta) method, $CO_2$ gas production measurement, the titration method, and IR spectroscopy. The results are demonstrated to be well comparable to a change in the fluorescence emission ratio (FER), which is defined as the shift in fluorescence intensity in the measured wavelength range, and also to the chromatic ratio, which is defined as a color shift to longer wavelength ranges. The results also show that, by using UV-vis spectroscopy, it is possible to detect the degradation of the insulating paper. This study suggests that UV-vis spectroscopy can be applied as an alternative to high-performance liquid chromatography, which is the internationally recognized measurement technology for cellulose paper degradation. The FER detector is also verified to be useful as an effective condition-monitoring device for power transformers.

와전류 손실을 적용한 금형으로 제조된 초고압 변압기의 프레스보드의 절연 특성 연구 (A Study on the Insulating Properties of Pressboard for High Voltage Transformer Applied the Mold of Eddy Current Loss)

  • 서왕벽
    • 한국전기전자재료학회논문지
    • /
    • 제28권8호
    • /
    • pp.508-512
    • /
    • 2015
  • Some insulating materials are tested and analyzed with variables to obtain the reliable pressboard which is located to core and coil of high voltage transformer. The high voltage transformer is used in electrical power system and operating reliability. Optimization possibility of pressboard shape including electrical insulation performance could be achieved by analysis simulation. Using insulating pressboard, which is made by mold applied eddy current loss, it could be measured the influences of moisture content for electrical properties. As a result, it is to contribute to improve the performance and ensure the reliability of the pressboard by investigating electrical strength according to the variation oil temperature. In addition pressboard thickness is important design factor to ensure electrical strength in high voltage transformer.

절연층으로 폴리이미드와 실리콘 산화막을 사용한 박막 압력 센서의 특성 비교 (Comparison of the Performance of Thin Film Pressure Sensors with Polyimid and Silicon Oxide as a Insulating Layer)

  • 민남기;이성래;전재형;김정완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.296-298
    • /
    • 1997
  • The performance of thin film pressure sensors with polyimide and silicon oxide as a insulating layer between the stainless steel diaphragm and the Cu-Ni strain gauges is presented. The polyimide was spun on the stainless steel diaphragm and cured in an oven. The silicon oxide was deposited by rf sputtering. The thin film pressure sensor with silicon oxide as a insulating layer showed a better nonlinearity and a lower hysteresis.

  • PDF

전기철도환경하에서의 서지방호용 절연변압기 제작 및 성능평가 (Manufacture and Performance Evaluation of Insulating Transformer for surge protection under Electric Railway Environments)

  • 이강원;김명룡;온정근;박대원;박건영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.176-177
    • /
    • 2006
  • The main aim of the paper is the study of the surge voltages in electric railway signal security system. Hence these studies will provide means of introducing a suitable protective device insulating transformer. This influences the surge voltage interrupting capacity using surge arresters and bypass capacitors. This circuit can be used for investigating surge phenomenon in electric railway signal security system. In this paper a insulating transformer has been introduced for the reduction of surge voltages in the above circuit model and performance evaluation.

  • PDF

온도에 따른 액체 절연유의 전기적 특성 (Electrical Properties of Liquid Insulation as a Function of Temperature )

  • 김태희;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제37권3호
    • /
    • pp.280-285
    • /
    • 2024
  • In this paper, the electrical properties of liquid insulating oil were analyzed by changing the ambient temperature change at 10℃ in-tervals from 0℃ to 30℃ through an insulation breakdown experiment in order to analyze the insulation performance of liquid in-sulating oil that varies according to temperature changes. As a result, it was confirmed through experiments that the lower the am-bient temperature, the higher the insulation breakdown voltage, depending on both the electrode shape and the electrode interval, and it was determined that the lower the ambient temperature, the higher the insulation performance of the liquid insulating oil.

폴리우레탄 폼을 도포한 갱폼사용에 따른 콘크리트 온도이력특성 (A study on thermal properties of concrete using gang form coated with polyurethane)

  • 남경용;원준연;강인선;전판근;이영도;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.11-12
    • /
    • 2011
  • This study examine Effect of Change of Compressive Strength of Concrete Members with Insulating Gang form on Temperature History of Concrete Positions. Test show, insulating gang forms differences and gang forms have 10℃ on peak point temperature of surface and Center if temperature history have 24Mpa by change of compressive strength. In addition, there have 14℃(16℃) on peak point temperature of surface and Center if temperature history have 40(60)Mpa. Therefore, insulating gang forms have an effect insulating performance.

  • PDF

페놀계 고분자를 이용한 절연막의 제작과 MIM구조에서의 전기적 특성 (Fabrication of insulating fifes using phenolic polymer and electrical properties in MIM structure)

  • 김경환;유승엽;정상범;박재철;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.347-349
    • /
    • 1999
  • We have fabricated insulating thin films using p-hexadecoxyphenol(p-Hp) that was formed phenol-formaldehyde resin of crosslinked structure from reaction with formaldehyde by LB technique. For fabricated MIM device, the possibility for insulating layers of electronic were investigated by electrical properties of their LB films according to crosslinking of LB films current-voltage (I-V) properties and frequency-capacitance (C-F) characteristics. We have provided evidence for the high insulating performance of phenol-formaldehyde thin films by the LB method. Conductivity of their LB films was as follows: pure water > 1 % aq. Formaldehyde > heat treatment, in the current-voltage (I-V) characteristics. It is demonstrated that insulation properties of crosslinked p-HP LB films were improved. In capacitance-frequency properties, the heat-treated p-HP LB films for crosslinking showed a low relative dielectric constant.

  • PDF

단열재용 페놀폼의 물성과 열적특성 (Properties and Thermal Characteristics of Phenol Foam for Heat Insulating Materials)

  • 김동권;이수복
    • 공업화학
    • /
    • 제17권4호
    • /
    • pp.357-360
    • /
    • 2006
  • 본 연구에서는 단열재로서의 페놀수지(PF) 발포폼의 물성과 응용가능성을 검토하였다. 실험결과 페놀수지 발포폼의 밀도는 $0.030g/cm^3$를 나타내었고, 열전도율은 $0.026kcal/m.h.^{\circ}C$를 나타내었다. 또한 페놀수지 발포폼은 $500^{\circ}C$로 1 h 동안 열을 가했을 경우 약 71.7 wt%가 휘발되었다. 그리고 페놀수지 발포폼의 화학구조는 단열재로서의 중요 물성인 closed cell 구조형태를 갖는 것으로 분석되었다. 따라서 제조된 페놀수지 발포폼은 단열소재로서의 우수한 물성을 갖는 것으로 확인되었다.

셀룰로오스 절연지의 열화온도에 따른 절연특성 및 통계처리에 의한 상관관계 규명 (Estimating for Properties of Insulating Degradation for Cellulose paper with Aging Temperature and Correlation by Statistical Treatment)

  • 김재훈;김대식;한상옥
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.912-917
    • /
    • 2010
  • It was known that oil-filled transformer's life depended on insulating paper which was applied to transformers for insulating of transformer. Therefore when paper was aged, its electrical, mechanical and chemical characteristics were changed. Especially if operating temperature was high, paper was quickly damaged. As cellulose paper which was mainly used for solid insulation of transformers was degraded, the cellulose polymer chains broke down into shorter lengths and gases such as CO, $CO_2$, $CH_4$, $C_2H_4$ and so on were produced from paper. Also by-product known as furan compounds were producted from paper and it were dissolved within insulating oil. In this paper accelerating aging cell was aged during 60 hours at 100, 150, 180 and $200^{\circ}C$, respectively, so evaluating the chemical characteristics of cellulose paper by thermal. An it were performed analysis such as tensile strength(TS), dissolved gas analysis(DGA) and high performance liquid chromatography(HPLC). Also for analyzing of correlation between insulating degradation characteristics, it was performed linear regression method as statistical treatment.