• 제목/요약/키워드: insulated gang form

검색결과 6건 처리시간 0.023초

동절기 단열거푸집을 적용한 콘크리트 열분석 특성 (Characteristics of Thermal Analysis of Concrete Applied with Insulated Formwork in Winter)

  • 남경용;김성덕;최석;유정일
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.246-247
    • /
    • 2021
  • This paper aims to quantitatively evaluate concrete quality factors according to the application of thermal insulated gang form. As a result of the experiment, it was found that the amount of calcium hydroxide produced increased in the insulated gang form than in the general gang form, and the thicker the insulation of the insulated gang form, the greater the amount of calcium hydroxide produced.

  • PDF

단열갱폼 적용에 따른 동절기 보양비 사용량 및 발열량 검토에 관한 실험적 연구 (A Study on the Energy Consumption Cost in the Winter and Calorific Value by Insulated Gang-form)

  • 남경용;최석;안성진;임명관
    • 한국건축시공학회지
    • /
    • 제20권1호
    • /
    • pp.53-60
    • /
    • 2020
  • 본 논문은 동절기 콘크리트 보양 시 투입되는 에너지(전력) 소비량과 콘크리트 발열량 변화를 통해 단열갱폼의 단열성능을 검토하고자 하였다. 실험결과에 따르면, 일반갱폼은 콘크리트 타설 이후 12시간동안 에너지(전력) 소비가 3회 발생하게 된다. 반면 단열갱폼은 콘크리트 타설 후 21시간 동안 에너지(전력) 소비가 발생되지 않았다. 최종 전력 소비량은 일반갱폼이 단열갱폼보다 3.7배 높게 나타나 에너지(전력) 소비에서 단열갱폼의 우수한 성능을 확인할 수 있었다. 발열량 검토결과는 일반갱폼에서 콘크리트 타설 후 외기 온도변화에 따라 발열량이 크게 변하는 것을 알 수 있었다. 하지만 단열갱폼의 경우 프레임 일부에서 미비한 열손실이 발생했을 뿐 콘크리트 타설 직후부터 거푸집 탈형까지 일정한 발열패턴을 보여주고 있었다.

동절기 단열갱폼의 발열량 변화 측정에 관한 연구 (A Study on the Calorific Value of Insulated Gang-form in Winter)

  • 강인선;원준연;김태희;김성덕;최석;남경용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.135-136
    • /
    • 2017
  • This paper examines the efficiency of the application of conventional and insulated gang forms for curing and protection of concrete by comparing the amount of electric energy required therefor. In addition, a thermal vision camera was used to identify heat loss from surfaces of the gang forms after each placement of concrete. Experimental results, show that the heat loss at the submerged temperature was large at the submerged surface due to the large calorific value at the surface of the mold. The insulated gang form had some heat loss in the horizontal bars. In the case of adiabatic reforming, the pattern shows a constant calorific value over time. In conclusion, the insulation performance is better than that of general gang form.

  • PDF

동절기 단열갱폼 취약부 보완 대책에 관한 연구 (A study on supplementary measure for the vulnerable part of insulated gang form in winter)

  • 최석;임명관;유정일;남경용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.138-139
    • /
    • 2022
  • Through previous studies, it was reviewed how to improve the insulation performance of weak areas by installing heated wires as a solution to the corners pointed out as weak areas when applying the insulation gang form and the existing pouring areas.

  • PDF

동절기 단열갱폼으로 인한 경제성 효과 및 투입 원가 분석 연구 (A Study on the Economical Efficiency and Cost Analysis of Winter Construction by Application of Insulated Gang-form)

  • 원준연;이영도;남경용
    • 한국건축시공학회지
    • /
    • 제18권4호
    • /
    • pp.347-354
    • /
    • 2018
  • 본 논문은 단열갱폼의 공동주택현장 적용을 통해 단열갱폼 동절기 보양우수성을 확인하고, 현장 적용에 따른 경제적 타당성을 분석하고 있다. 실험결과에 따르면 실제 보양투입 비용은 사전계획대비 약 5천 2백만 원을 절감하였으며, 기존 일반갱폼대비 약 1억 6천만 원을 절감하였다.(참고 - 변경전 갱폼 자재비는 2억 6천만 원에서 변경 후 3억 1천만 원으로 약 5천만 원 증가함) 결과적으로 단열갱폼으로 변경하여 약 1.1억 원 가량의 공사비를 절감할 수 있었다. 현장마다 층수, 동수, 면적이 달라짐에 따라 보양공사비가 변경될 수 있으니 단열갱폼 적용 예정인 현장에서는 사전에 충분한 검토가 이루어져야 할 것으로 판단된다.