• Title/Summary/Keyword: instrumentation and control system

Search Result 935, Processing Time 0.029 seconds

NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study

  • Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권6호
    • /
    • pp.343-349
    • /
    • 2012
  • Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.

Radiation-induced transformation of Hafnium composition

  • Ulybkin, Alexander;Rybka, Alexander;Kovtun, Konstantin;Kutny, Vladimir;Voyevodin, Victor;Pudov, Alexey;Azhazha, Roman
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1964-1969
    • /
    • 2019
  • The safety and efficiency of nuclear reactors largely depend on the monitoring and control of nuclear radiation. Due to the unique nuclear-physical characteristics, Hf is one of the most promising materials for the manufacturing of the control rods and the emitters of neutron detectors. It is proposed to use the Compton neutron detector with the emitter made of Hf in the In-core Instrumentation System (ICIS) for monitoring the neutron field. The main advantages of such a detector in comparison the conventional β-emission sensors are the possibility of reaching of a higher cumulative radiation dose and the absence of signal delays. The response time of the detection is extremely important when a nuclear reactor is operating near its critical operational parameters. Taking Hf as an example, the general principles for calculating the chains of materials transformation under neutron irradiation are reported. The influence of 179m1Hf on the Hf composition changing dynamics and the process of transmutants' (Ta, W) generation were determined. The effect of these processes on the absorbing properties of Hf, which inevitably predetermine the lifetime of the detector and its ability to generate a signal, is estimated.

대규모 비선형 시스템의 새로운 계층별 최적제어 (A New Approach for Hierarchical Optimization of Large Scale Non-linear Systems)

  • 박준훈;김종부
    • 전자공학회논문지T
    • /
    • 제36T권2호
    • /
    • pp.21-31
    • /
    • 1999
  • 대규모 시스템 제어와 관련하여 몇 개의 부시스템으로 분할하여 처리하는 계층별 제어이론이 많이 연구되어 왔으며 특히 치수가 높은 대규모 비선형 시스템의 경우에 고차의 비선형 미분방정식을 동시에 적분을 해야하고 많은 계산량을 필요로 하므로 해를 구하기가 어려운 문제가 있다. 1980년대 Singh과 Hassan은 상호예측 알고리즘(two level prediction algorithm)을 제시한바 있고 이 방법은 비선형 대규모 시스템의 최적제어에 효과적이나 시스템 행렬 Q, R, S, H에 따라 제한된 최적화 구간에서만 성립되는 등 최적화 구간의 길이와 수렴성 여부가 행렬 값에 영향을 받는 알고리즘상의 단점이 있다. 본 연구에서는 수렴조건으로부터 평가함수에 구속조건(quadratic penalty term)을 부여하지 않는 새로운 개선된 알고리즘을 제시 적용하여 시스템 행렬 결정을 위한 과정 없이 수렴속도의 향상과 함께 최적의 수렴성 및 최적화 구간을 얻도록 했다. 분할된 비선형 시스템의 최적제어를 위해서는, 대수 반복연산만으로 2점 경계치 문제(two point boundary value problem)를 해결함으로써 기존의 수치 해석법에 비해 연산이 간단한 블록펄스 변환 방법을 사용해서 처리했다.

  • PDF

손바닥을 이용한 쿨링이 심부 체온에 미치는 효과 (The Effect of Cooling by using Hand on Body Temperature)

  • 김정훈;박지은;박유진;원철호;지인희;김지인;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권4호
    • /
    • pp.163-167
    • /
    • 2017
  • The purpose of this study is to perform integrated body temperature cooling of the arteriovenous anastomosis site. In the arteriovenous anastomosis site, heart cooling was performed using the palm of the hand, Cooling was achieved by using Peltier and copper plates to cool the palm of the hand with the heat transferred. The control range of the conducted heat is adjustable from 25 degrees to 30 degrees. The experimental environment was to place the treadmill in the house, The temperature in the house was set at 40 degrees and the experimenter treadmill at a speed of 5 Km. The subjects were exercised until the body temperature reached about $39^{\circ}C$. As a method to lower the body temperature after the experiment, the data of the body temperature was obtained by the general rest, onehand cooling, two-hand cooling. Experiment result better than normal rest when Two hands cooling and an average decrease of 0.66 degrees. if you develop a cooling glove with Peltier, it will be an epoch-making athletic assistant to achieve thermal fatigue.

소화관 내 압력 측정을 위한 텔레메트리 캡슐 구현 (Telemetry capsule for pressure monitoring in the gastrointestinal tract)

  • 윤기원;우상효;이정현;문연관;박희준;원철호;김병규;최현철;조진호
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.211-218
    • /
    • 2005
  • As the cause and the treatment about gastrointestinal disease has been issued recently, the importance of measuring the pressure in the gastrointestinal tract has been increased. However, the conventional measurement methods of the pressure in the gastrointestinal tract cause the patients' pain and inconvenience as well as an inaccurate pressure measurement. In this paper, the pressure monitoring telemetry system has been designed and implemented for an accurate pressure measurement inside the gastrointestinal tract with minimizing pain and inconvenience. The pressure monitoring telemetry system is composed of a pressure measurement capsule and an external receiver. The capsule has been miniaturized into the same size of a vitamin tablet so that the capsule can be swallowed through the oral cavity. After the capsule acquires and encodes the pressure data in the gastrointestinal tract, the encoded pressure data are modulated by frequency shift keying (FSK) and transmitted with ultrahigh frequency (UHF) band signal to the outside of a body. The performance of the telemetry capsule for monitoring pressure in the gastrointestinal tract is demonstrated by the results of animal in-vivo experiments.

지하철 터널 환경에서 다양한 안테나에 따른 2.45GHz 대역의 경로손실 및 지연 특성 (Path Loss and Delay Characteristics According to Various Antennas at 2.45GHz in Subway Tunnel Environment)

  • 공민한;박노준;강영진;송문규
    • 대한전자공학회논문지TC
    • /
    • 제43권5호
    • /
    • pp.162-168
    • /
    • 2006
  • 전파 특성의 이해는 무선 통신 시스템의 설계와 서비스의 구축을 위해 매우 중요하다. 본 논문에서는 곡선형 지하철 터널환경에서 2.45GHz 주파수 대역의 전파 특성을 측정하고 분석하였다. 슬라이딩 코릴레이션 기반의 채널 측정 시스템을 구성하고 안테나의 빔 형태에 따른 특성을 비교하기 위해 5 종류의 안테나를 사용하였다. 터널내 경로손실은 자유공간에 비하여 안테나에 따라 평균 $4.38^{\sim}14.41dB$가 적고 원편파 안테나의 경로손실이 가장 적다. 또한 곡선구간에서 수신 안테나의 위치가 바깥쪽에 위치할 때 경로손실이 가장 적다. 모든 안테나의 지연성분의 90%가 20ns 이내에 존재하며, 지향성 안테나가 무지향성 안테나보다 더 넓은 코히어런스 대역폭을 갖는다. 측정결과 경로손실과 지연 특성을 고려할 때 지하철 터널에서는 원편파 안테나를 사용하는 것이 적합한 것으로 판단된다.

상용 도구를 이용한 대용량 교통 데이터의 추출 및 적재 방안 (A Method for Extraction and Loading of Massive Traffic Data using Commercial Tools)

  • 우찬일;전세길
    • 한국항행학회논문지
    • /
    • 제12권1호
    • /
    • pp.46-53
    • /
    • 2008
  • 지능형 교통 체계(ITS: Intelligent Transport Systems)는 기존의 교통에 정보통신, 전기 및 전자, 기계, 제어 동의 기술을 접목시켜 도로 및 교통 체계의 안전 및 운영 효율을 극대화하여 교통 문제를 해결하는 시스템이다. 현재 대량의 교통 원시 데이터를 위해 시스템을 통합하는 문제는 다른 소스데이터 간의 표현상의 이질성 및 데이터의 양과 다양성 그리고 소스의 자동화와 서로 다른 성능 등 몇 가지 문제에 직면해 있다. 본 논문에서는 고속도로 교통관리시스템과 우회도로 교통정보시스템에서 수집되는 이질적인 대용량 교통데이터의 데이터웨어하우스를 구축하기 위해 상용 도구를 활용해 추출 및 적재하는 방안을 기술한다. 또한, 고품질 교통데이터를 제공하기 위한 통합 품질관리 기법을 적용하여 평가 한다.

  • PDF

고속 신호처리 회로에 의한 고속철도 차륜검사 (Improvement of Signal Processing Circuit for Inspecting Cracks on the Express Train Wheel)

  • 황지성;이진이;권석진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.579-584
    • /
    • 2008
  • 고속철도 차륜의 미소결함을 고속 고공간 분해 능으로 측정할 수 있는 새로운 비파괴검사법이 요구되고 있다. 본 연구는 종래의 스캔형 자기카메라를 개선하여, 다중증폭회로와 결함표시를 위한 펄스 발생기를 장착한 신호처리회로를 제안한다. 홀센서를 선형으로 배열하고, 배열의 직각방향으로 차륜이 정속으로 회전하게 하면, 차륜의 답면을 검사할 수 있다. 각각의 홀전압을 증폭하고, AD변환기를 통하여 $\mu$-processor에 의하여 시간에 따른 전압차, 즉 ${\partial}V_H/{\partial}t$를 연산한다. ${\partial}V_H/{\partial}t$가 결함의 존재를 의미하는 비교치보다 클 때 pulse 신호가 발생하여 결함을 지시한다. 휠 시험편을 이용하여 제안된 방법을 검증하였다.

  • PDF

샐룰라 오토마타 기법을 이용한 신경망의 자동설계에 관한 연구 (A Study on Automatic Design of Artificial Meural Networks using Cellular Automata Techniques)

  • 이동욱;심귀보
    • 전자공학회논문지S
    • /
    • 제35S권11호
    • /
    • pp.88-95
    • /
    • 1998
  • 본 논문은 인공생명 기법을 이용하여 생물의 정보처리 시스템을 구현하고자 하는 것이다. 자연계의 생물은 그 자체로 훌륭한 정보처리 시스템이다. 생물체는 하나의 생식 세포로부터 발생된다. 또한 이 개체의 종은 진화의 과정을 통해 환경에 적응한다. 본 논문에서는 이와 같은 생물학적인 발생과 진화의 개념을 이용하여 신경망을 설계하는 방법을 제안한다. 생물체의 개체발생은 발생모델의 하나인 셀룰라 오토마다(CA)를 통하여 구현하였고 진화과정은 진화 알고리즘(EAs)을 사용하였다. 우리는 이와 같이 구현한 '진화하는 셀룰라 오토마타 신경망'을 줄여서 ECANS1이라 명명하였다. 셀 사이의 연결은 CA 법칙에 의하여 결정되며, 셀의 초기 패턴이 진화함으로써 유용한 신경망을 찾아낸다. 신경망의 각 셀 즉 뉴런은 생물의 발화 ${\cdot}$ 비발화의 특성을 갖는 카오스 뉴런 모델을 사용하였다. 그리고 신경마의 최종 출력값은 뉴런의 발화 빈도로서 나타내었다. 제안한 방법은 Exclusive-OR 문제 및 패리티 문제에 적용함으로써 그 유효성을 검증하였다.

  • PDF

이식형 인공중이 시스템을 위한 고효율 차동 전자 트랜스듀서의 설계 (Design of High Efficiency Differential Electromagnetic Type Transducer for Implantable Middle Ear System)

  • 송병섭;노철균;김명남;조진호
    • 센서학회지
    • /
    • 제11권3호
    • /
    • pp.171-182
    • /
    • 2002
  • 이식형 인공중이에 사용되는 일반적인 전자기 방식의 진동 트랜스듀서에 비하여 두 개의 소형 영구자석을 같은 극끼리 접착한 후 코일내부에 위치시킨 차동 전자 트랜스듀서는 효율이 높고 코일-영구자석간의 공극조정이 필요 없으며 외부의 자기장에 대하여 영향을 받지 않는 특성을 가진다. 본 논문에서는 이러한 차동 전자 트랜스듀서를 이식형 인공중이 시스템에 사용하기 위하여 입력전류에 대하여 진동력의 크기를 최대화시킬 수 있는 효율적인 구조를 제안, 해석하였다. 유한요소 해석을 통하여 가장 효율적인 코일과 자석의 길이 비를 도출하였고 소리신호 전달을 위한 트랜스듀서의 필요 진동력을 산출한 후 트랜스듀서 발생 진동력을 해석하였다. 그리고 실제 이소골에 이식할 수 있는 크기의 트랜스듀서를 제작하기 위한 설계상수를 추출하였다. 계산된 설계상수를 이용하여 이식 가능한 크기로 트랜스듀서를 구현한 후 무부하 실험과 사체 부하 실험을 실시하여 제작된 트랜스듀서가 실제 중등이상 고도난청자를 위한 이식형 인공중이 시스템에 사용될 수 있음을 증명하였다.