• Title/Summary/Keyword: instrumental correction

Search Result 24, Processing Time 0.028 seconds

Hydraulic Pulsation and Noise Reduction using the Helmholtz Attenuator (헬름홀츠 감쇠기를 응용한 유압시스템의 유압맥동 및 소음 최소화 연구)

  • 김동현;이대옥;최근국
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.614-619
    • /
    • 1997
  • The hydraulic pressure pulsation has on the effected on the acoustic nosie and control performance of the hydraulic-servo system. The Helmholtz attenuator introduction on the hydraulic line is an efficient device to reduce the hydraulic pulsation. The salient feature of causing hydraulic pulsation and the frequency characteristics of Helmholtz attenuator are studied. The hydraulic filter design parameters such as the locating position, connecting orifice area and accumulator volume are mathematically analyzed. The instrumental works are carried out with the remarkable reduction of the hydraulic pressure pulsation magnitude and the acoustic noise level.

  • PDF

On the Sampling and Transport of Radioactive Aerosols from Waste Thermal Process

  • Yang, Hee-Chul;Kim, Joon-Hyung;Yong Kang
    • Nuclear Engineering and Technology
    • /
    • v.29 no.4
    • /
    • pp.269-279
    • /
    • 1997
  • The errors associated with incorrect sampling and transport of radioactive aerosol from radwaste thermal process off-gas are analyzed and the conditions of representative sampling and correct transport of radioactive aerosol for off-gas system evaluation are discussed. An estimation method of sampling errors for individual radionuclides is proposed and applied to simulated vitrification melter aerosols. Prediction methods for particle deposition in sample transport tube under laminar as well as turbulent flow conditions are also described by example calculations with simulated incinerator off-gas From the results of example calculations and plots, instrumental and operational conditions of radioactive aerosol sampling system with minimized errors and correction methods for nonideal sampling and transport are recommended.

  • PDF

Setup and Atomic Calibration of Particle Induced X-ray Emission System

  • Song, Jin-Ho;Song, Jae-Bong;;Kim, Jun-Gon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.206.2-206.2
    • /
    • 2014
  • Recently, particle induced X-ray emission (PIXE) analysis system was installed at the 2MV ion acceleration system in Korea institute science and technology (KIST). This installation is for complement to low atomic resolution of heavy atoms at Rutherford backscattering spectrometry (RBS) system. For quantitative analysis, a mass calibration of the PIXE set-up has been done with thin film standards and. The GUPIX software package has been used to process the PIXE spectra and the results are compared with the values from RBS system. Therefore, the instrumental constant H (solid angle and correction factor) is determined relying completely on the GUPIX data base (cross-sections, fluorescence and Coster-Kronig probabilities, stopping powers and attenuation coefficients) for a large set of elements. These H values can be used in future analysis.

  • PDF

Grammaticality Judgement and Error Correction by Children with Developmental Language Impairments (경계선지능 언어발달장애아동과 일반아동의 문법성 판단 및 오류수정 - 조사를 중심으로 -)

  • Lim, Jong-Ah;Hwang, Min-A
    • Speech Sciences
    • /
    • v.13 no.2
    • /
    • pp.59-72
    • /
    • 2006
  • In the present study, we investigated the grammaticality judgement skills of children with developmental language impairments. The participants included 20 children with language impairments of ages ranging from 7 to 9 years and of IQ's ranging from 71 to 84, and 40 normally developing children. Twenty normal children were matched with the language impaired children in their language ages and the other 20 normal children were matched with the language impaired children in their chronological ages. The children were asked to judge the grammatical correctness of 48 short sentences, half of which were ungrammatical sentences containing incorrect case-markers and the other half were grammatically correct sentences. Four types of case-markers including nominative "i/ga", accusative "ul/lul", locative "e," and instrumental "ro" were systematically changed to generate the ungrammatical sentences. The language impaired children performed worse than both groups of normally developing children in detecting the ungrammatical sentences and in correcting the case-markers of those sentences. In detecting the errors of ungrammatical sentences, the language impaired children exhibited variable performances across the different case-markers.

  • PDF

Study on the Relations to Estimate Instrumental Seismic Intensities for the Moderate Earthquakes in South Korea (국내 중규모 지진에 대한 계측진도 추정식 연구)

  • Yun, Kwan-Hee;Lee, Kang-Ryel
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.323-332
    • /
    • 2018
  • Recent two moderate earthquakes (2016 $M_w=5.4$ Gyeongju and 2017 $M_w=5.5$ Pohang) in Korea provided the unique chance of developing a set of relations to estimate instrumental seismic intensity in Korea by augmenting the time-history data from MMI seismic intensity regions above V to the insufficient data previously accumulated from the MMI regions limited up to IV. The MMI intensity regions of V and VI was identified by delineating the epicentral distance from the reference intensity statistics in distance derived by using the integrated MMI data obtained by combining the intensity survey results of KMA (Korea Meteorological Administration) and 'DYFI (Did You Feel It)' MMIs of USGS. The time-histories of the seismic stations from the MMI intensity regions above V were then preprocessed by applying the previously developed site-correction filters to be converted to a site-equivalent condition in a manner consistent with the previous study. The average values of the ground-motion parameters for the three ground motion parameters of PGA, PGV and BSPGA (Bracketed Summation of PGA per second for 30 seconds) were calculated for the MMI=V and VI and used to generate the dataset of the average values of the ground-motion parameters for the individual MMIs from I to VI. Based on this dataset, the linear regression analysis resulted in the following relations with proposed valid ranges of MMI. $MMI=2.36{\times}log_{10}(PGA(gal))+1.44$ ($I{\leq}MMI$$MMI=2.44{\times}log_{10}(PGV(kine))+4.86$ ($I{\leq}MMI$$MMI=2.59{\times}log_{10}(BSPGA(gal{\cdot}sec))-1.02$ ($I{\leq}MMI$

AKARI OBSERVATIONS OF THE FLUCTUATIONS OF THE NEAR-INFRARED BACKGROUND II

  • Seo, H.J.;Lee, H.M.;Matsumoto, T.;Jeong, W.S.;Lee, M.G.;Pyo, J.
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.327-329
    • /
    • 2017
  • We report a spatial fluctuation analysis of the sky brightness in the near-infrared from observations towards the north ecliptic pole (NEP) by AKARI at 2.4 and $3.2{\mu}m$. As a follow up study of our previous work on the Monitor field of AKARI, we used NEP deep survey data, which covered a circular area of about 0.4 square degrees, in order to extend fluctuation analysis at angular scales up to 1000". After pre-processing, additional correction procedures were done to correct time varying components and instrumental effects such as MUXbleed. To remove resolved objects, we applied $2{\sigma}$ clipping and point spread function (PSF) subtraction. We finally obtained mosaicked images which can be used for the study of various diffuse emissions in the near-infrared sky and found that there are spatial structures in the mosaicked images using a power spectrum analysis.

Development and Evaluation of a Community based Multifaceted Cognitive Training Program for the Elderly with Mild Cognitive Impairment (경도인지장애 노인을 위한 지역사회 기반 다면적 인지훈련 프로그램 개발 및 효과평가)

  • Park, Yeonhee;Oh, Heeyoung
    • Research in Community and Public Health Nursing
    • /
    • v.30 no.2
    • /
    • pp.119-129
    • /
    • 2019
  • Purpose: The purpose of this study is to develop and evaluate the effects of a multifaceted cognitive training program on cognitive function, depression, and instrumental activities of daily living (IADL) in community dwelling elders with mild cognitive impairment. Methods: A non-equivalent control group pretest-posttest design was used. The subjects were recruited from a community health center in D metropolitan city and were assigned to the experimental or control group. Weekly 50-minute session intervention was delivered to the experimental group over 12 weeks. 8 weeks and 12weeks after intervention, the changes in cognitive function, depression, and IADL in the groups were measured and compared. Data were analyzed with Mann-Whitney U test, Wilcoxon Signed Rank test, and post-hoc test with Bonferroni correction using SPSS/WIN 23.0. Results: When compared with their counterparts (n=15), the elders in the experimental group (n=12) showed significant improvement in cognitive function and depression at week 12. The mean scores of IADL at week 12 were not significantly different between the groups. Conclusion: The results indicate that this multifaceted cognitive training program is effective in improving cognitive function, depression, and avoiding deterioration of IADL among elders with mild cognitive impairment.

Installation and Data Analysis of Superconducting Gravimeter in MunGyung, Korea; Preliminary Results (문경 초전도 중력계 설치 및 기초자료 분석)

  • Kim, Tae-Hee;Neumeyer, Juergen;Woo, Ik;Park, Hyuck-Jin;Kim, Jeong-Woo
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.445-459
    • /
    • 2007
  • Superconducting Gravimeter(SG) was installed and has been successfully operated at MunGyung, Kyungsang province in Korea in March 2005. It was registered as the 21st observatory of the Global Geodynamics Project. Since SG can precisely measure the gravity variations below the 1mHz frequency band, it has the outstanding capability to sense and resolve many different periodic gravity components from each other. From the raw data collected between 18 March 2005 and 21 February 2006 diurnal and semi-diurnal tidal band's residual gravity components were analyzed. During this process, the instrumental noises, air pressure, and ground water corrections were carried out. Values of $-3.18nm/s^2/hPa\;and\;17nm/s^2/m$ were used respectively in the air pressure and groundwater corrections. Hartmann-Wenzel and Whar-Dehant Earth tide models were adopted to compute the residual gravity for Q1, O1, P1, K1, M2, N2, S2, K2 tidal bands. For the ocean loading correction, SCW80, FES952, and FES02 models were used and compared. As a result, FES02 ocean loading model has shown the best match for the data processing at MunGyung SG MunGyung SG gravity was compared with GRACE satellite gravity. The correlation coefficient between the two gravity after groundwater correction was 0.628, which is higher than before ground water correction. To evaluate sensitivity at MunGyung SG gravity statition, the gravity data measured during 2005 Indodesian earthquake was compared with STS-2 broad band seismometer data. The result clearly revealed that the SG could recorded the same period of earthquake with seismometer event and a few after-shock events those were detected by seismometer.

Analysis of the Risk Factors for Unfavorable Radiologic Outcomes after Fusion Surgery in Thoracolumbar Burst Fracture : What Amount of Postoperative Thoracolumbar Kyphosis Correction is Reasonable?

  • Seo, Dong Kwang;Kim, Chung Hwan;Jung, Sang Ku;Kim, Moon Kyu;Choi, Soo Jung;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.96-105
    • /
    • 2019
  • Objective : The aims in the management of thoracolumbar spinal fractures are not only to restore vertebral column stability, but also to obtain acceptable alignment of the thoracolumbar junction (T-L junction) to prevent complications. However, insufficient surgical correction of the thoracolumbar spine would be likely to cause late progression of abnormal kyphosis. Therefore, we identified the surgical factors that affected unfavorable radiologic outcomes of the thoracolumbar spine after surgery. Methods : This study was conducted in a single institution from January 2007 to December 2013. A total of 98 patients with unstable thoracolumbar spine fracture were included. In these patients, fixation was done through transpedicular screws with rods by three surgical patterns. We reviewed digital radiographs and analyzed the images preoperatively and postoperatively during follow-up visits to compare the change of the thoracolumbar Cobb angle with radiologic parameters and clinical outcomes. The unfavorable radiologic group was defined as the patients who were measured as having greater than 20 degrees of thoracolumbar Cobb angle on the last follow-up, or who underwent kyphotic progression of thoracolumbar Cobb angle greater than 10 degrees from the immediate postoperative state to final follow-up, or who had overt instrument failure with/without additional surgery. We assessed the risk factors that affected the unfavorable radiologic outcomes. Results : We had 43 patients with unfavorable radiologic outcomes, including 35 abnormal thoracolumbar alignments and 14 instrumental failures with/without additional surgery. The multivariate logistic regression test showed that immediate postoperative T-L junction Cobb angle less than 10.5 degrees was a statistically significant risk factor, as well as the presence of osteoporosis (p=0.017 and 0.049, respectively). Conclusion : Insufficient correction of thoracolumbar kyphosis was considered to be a major factor of an unfavorable radiological outcome. The spinal surgeon should consider that having a T-L junction Cobb angle larger than 10.5 degrees immediately after surgery could result in an unfavorable radiological outcome, which is related to a poor clinical outcome.

Development of a Voltage Measuring System for the Pusan-Hamada Submarine Cable (부산 - 병전간 해저케이블 전압측정 장치의 개발)

  • Bahk, Kyung-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.3 no.4
    • /
    • pp.255-260
    • /
    • 1991
  • A voltage measuring system specified for the voltage fluctuation of the Pusan-Hamada submarine cable is developed by adding circuits of differential amplification and analog-to-digital conversion to a microprocessor-based data logger with a data modem. This system is charaterized by its small size. no power failure. fully unmanned operation. and precise instrumental drift correction. In addition to the cable voltage and current it measures an ambient temperature and a mercury cell voltage in order to calibrate temperature effect and check its long-term stability. The data acquired by this system show that the voltage signal. comprising fast random noises with a constant width of about 0.2V. fluctuates within a range of about 1V and the fluctuation frequency is similar to that of tidal motion. The source voltage of power feeding equipment (PFE) for the cable system seems to be affected when the room temperature changes rapidly.

  • PDF