• 제목/요약/키워드: instantaneous voltage compensator

검색결과 33건 처리시간 0.026초

순간전압강하 보상기의 설계와 해석 (Design and Analysis of Instantaneous Voltage Drop Compensator)

  • 이택기;현동석;황용하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.478-481
    • /
    • 1991
  • This paper discusses the principle and structure of instantaneous voltage drop compensator, which protects damage from instantaneous voltage drop in systems such as computer, variable speed drive, high voltage discharge-lamp, magnet switch. When instantaneous voltage drop occurs, control circuits detect it, then produce output voltage the same as normal condition voltage. Instantaneous voltage drop compensator has condenser bank as energy storage component, so system can be made small, light weight compared with UPS. In normal state, utility source transfers power, and in instantaneous voltage drop state, the energy of condenser bank transfers power through inverter, so high efficiency, compact, and especially low cost system can be manufactured.

  • PDF

3상 PWM 인버터를 이용한 순간전압보상기의 해석 (Analysis of Instantaneous Voltage Compensator Using 3-Phase PWM Inverter)

  • 최연규;이승요;최규하;목형수;함형원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.222-227
    • /
    • 1997
  • Unbalanced source voltages due to unbalanced loads in the 3-phase power system is decomposed into positive, negative and zero sequence components. Also, assuming there is no neutural path in the system, the zero sequence component is not shown. Therefore, it is possible to compensate unbalanced source voltage by canceling the negative sequency component of the voltages of the source. In this paper, an algorithm compensating unbalanced source voltages by canceling the negative sequence component is presented and analysis of instantaneous voltage compensator using 3-phase PWM inverter is carried out through computer simulation.

  • PDF

전류형 PWN 콘버어터의 희한 정지형 무효전력 보상장치에 관한연구 (Static Var Compensator Using Current Source PWM Converter)

  • 김철우;권순재;김광태
    • 대한전기학회논문지
    • /
    • 제39권11호
    • /
    • pp.1183-1190
    • /
    • 1990
  • In this paper, instantaneous reactive power compensation algorithm is proposed and analyzed. The static Var generator developed in this paper is the current source PWM converter using hysteresis comparator method, which compensates the reactive power by detecting each instantaneous phase voltage and line current, independently. Some aspects on the static Var compensator-such as inductance, capacitance, hysteresis width, and switching frequency, etc.-are discussed. The dynamic performances are examined through digital simulation and experimental test.

  • PDF

150kVA급 전기품질 보상기기 제어 알고리즘 설계 (The Design of control algorithm for 150kVA power quality compensator)

  • 전진흥;김지원;전영환;김호용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1070-1072
    • /
    • 2001
  • In recent years, customers and power supplies are interested in power quality. Demands of customers are change from standard quality of distribution power system to various high quality of distribution power system. so, it is necessary to apply power quality compensator, in our project, we develop the power quality compensator of 150kVA which compensates power factor and voltage sag, interruption. it is very frequently occurred power qualify problems[1,2]. As a series and shunt compensator, power quality compensator consists of two inverters with common do link capacitor bank. It compensates the current quality in the shunt part and the voltage qualify in the series part. In this paper we present the design and control algorithm of power quality compensator. As a control algorithm is implemented by digital controller, we consider sample-and-hold of signals. In this simulation, we use EMTDC/PSCAD V3.0 software which can simulate instantaneous voltage and current.

  • PDF

3상 PWM 콘버어터에 의한 정지형 무효전력 보상장치의 동작특성( II ) (Static VAR Compensator Using 3-Phase PWM Converter(II))

  • 권순재;황영문;김광태;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.287-289
    • /
    • 1988
  • A reactive power compensator whiych employs a 3-phase voltage source PWM converter is presented and ana lysed in this study. In this study, instantaneous reactive power compensator by the theort of instantaneous real and imaginary power are theoretically studied how to compensate reactive power occured by fundamental and harmonic reactive current. And we showed the compensation characteristic as well as the capacity of condenser.

  • PDF

3상 PWM 콘버어터에 의한 정지형 무효전력 보상장치의 동작특성 (Static VAR Compensator Using 3 Phase PWM converter)

  • 김철우;김광태;권순재;홍순일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.137-139
    • /
    • 1988
  • A reactive power compensator whitch employs a three phase voltage source PWM converter is presented and analysed in this study. In this study, instantaneous reactive power compensator by the theory of instantaneous real and imaginary power are theoretically studied how to compensate reactive power occured by fundamental and harmonic reactive current. And we showed the compensation characteristics by comparing the experimental results with those of computer simulation.

  • PDF

전류제어형 PWM 컨버터에 의한 순시 무효전력 보상장치 (Instantaneous Reactive Power Compensator using Current Controlled PWM Converter)

  • 최재호;김상훈;박민호
    • 대한전기학회논문지
    • /
    • 제38권7호
    • /
    • pp.539-548
    • /
    • 1989
  • 본 논문에서는 싸이리스터 부하에서 발생하는 무효전력과 고조파를 보상하기 위한 순시무효전력 보상장치에 관하여 기술하였다. 저자는 기본파 위상 지연과 고조파 전류외형에 기인하는 순시무효전력을 새로이 정의하고 순시전력흐름의 관점에서 그 물리적 의미를 고찰하였다. 순시전압 및 순시전류의 궤환에 의해 순시무효전력을 계산하고, 이를 부하와 병렬로 연결된 전류제어형 PWM컨버터에 의해 보상하였다. PWM컨버터는 전류오차 백터제어방식에 의한 전류제어 PWM 기법을 사용함으로써 우수한 전류제어특성을 실현할 수 있었다. 시뮬레이션과 실험을 통하여 정상상태 및 과도상태에서의 탁월한 보상특성이 입증되었다.

직렬 전압주입에 의한 순간전압강하 보상기기에 관한 연구 (A Study on the Instantaneous Voltage Drop Compensator through the Series Voltage Injection)

  • 전영환;김지원;전진홍
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.310-317
    • /
    • 2001
  • 동일한 변압기에서 인출된 서로 다른 선로중 하나의 선로에서 고장이 발생하는 경우 다른 선로에서는 순간적인 전압강하 현상을 경험하게 된다. 이렇게 발생되는 순간전압강하 현상은 비록 선로의 계전기에 의해 사고가 제거되기까지의 짧은 기간동안 지속되지만 기기에 따라서는 막대한 피해를 유발할 수 있다. 예로서, 반도체 공장의 정밀 공정중 순간전압강하가 발생하면 공정이 중단되거나 공정의 재시작등으로 인하여 a가대한 경제적 손실을 유발하게 된다. 또한 각종 정밀기기 등에는 기기의 수명저하를 유발하기도 한다. 본 논문에서는 전력계통에 직렬로 연결되는 인버터 시스템을 이용하여 계통에 전압을 주입함으로서 순간전압강하를 보상할 수 있는 시스템에 관하여 연구하고 운전 알고리즘을 제시하였다. 컴퓨터 시뮬레이션과 실험을 통하여 제시한 운전알고리즘의 유효성을 입증하였다.

  • PDF

A NEW INSTANTANEOUS VOLTAGE COMPENSATOR WITH FUNCTION OF ACTIVE POWER FILTERING

  • Lee, Seung-Yo;Lee, Jeong-Min;Lee, Sang-Yong;Mok, Hyung-Soo;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.780-784
    • /
    • 1998
  • A novel active input unbalance voltage compensator with harmonic current compensating capability is proposed and the operating principle of the proposed system is presented in the 3-phase power system. The proposed system performs both the voltage regulation of the load and the compensation of the harmonic currents generated due to nonlinear load such as diode rectifier. The system to compensate unbalanced voltage and hramonic currents is composed of a 3-phase voltage source inverter, LC filter, series transformer and passive devices at the load side of the line. The compensating voltage to regulate the load voltage and to remove the harmonic current components is transmitted to the line by the series transformer. The validity of the line by the series transformer. The validity of the proposed system is proved by the results of computer simulation.

  • PDF

A Novel Detection Algorithm for Instantaneous Voltage Sag Corrector Using Series Compensator

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.502-507
    • /
    • 2001
  • This paper proposes a novel detection algorithm of faulted voltages under the unbalanced condition. To quantify the standard of unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (MF). It is analyzed that MF and UF values are given as the dc constant values even though unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

  • PDF