• Title/Summary/Keyword: installation location

Search Result 609, Processing Time 0.024 seconds

Optimal Location of Mail Distribution Center using Steiner Tree (Steiner Tree 이론을 이용한 우편물 교환센터인 최적 워치선정)

  • Yang, Seong-Deog;Lyu, Woong-Gyu;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.82-87
    • /
    • 2008
  • Faster, safer and cheaper mailing of the postal matter is essential for surviving in the competitive market of home-delivery service. In the past, the domestic delivery business has been nu by only a few number of companies. But more and more number of companies including medium size ones are participating in the business, and the competition is getting severe. This paper proposes a method to select the optimal location of mail distribution centers that minimally connect the local mail centers of some major cities in Korea using the Steiner Tree theory, which is about connecting a finite number of points with a minimal length of paths and has been used in the distribution system optimization and optimal routing of the transmission lines of the electric power system. By using Steiner Tree theory in finding the best location of the postal delivery hub, we may expect the reduction of transportation cost and the increase of profit, resulting in acquiring the superior position in the competitive delivery business. It is expected that we may use the Steiner Tree theory in finding the best location of the electric power substation for the nott higher EHV(extreme high voltage) transmission network.

A field trial of helically wrapping fiber optic cable onto existing 154KV Phase conductor. (전력선을 이용한 광케이블 현장 실증 시험)

  • Shin, Keon-Hak;Lee, Won-Bin;Cho, Hong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.143-146
    • /
    • 1987
  • Fiber optics provide a solution to the problems at interference, capacity and reliability in communication. Approximately 20 kilometera of a six-fiber, multimode, longwave($1.3{\mu}m$), graded index silica glass fiber optic cable was helically wrapped around a phase conductor at a Korea Electric Power Corporation(KEPCO) 154KV transmission line. This paper presents an economic comparison of several fiber optic cable installation alternative and discusses the characteristics at the helically wrapped fiber cable, as well as the entire installation, including high voltage phase-to-ground (PTG) end termination, and splicing. The fiber link was installed for the field trial and practical use with overhead composite optical fiber cable which installation performed a few years earlier some other location and is intended to accommodate not only telephone but also supervisory Control and Data Acquisition(SCADA), protective relaying, and telemetry functions.

  • PDF

Structural Stability Study on the Location and Installation form of H-beam Backfill Applied to Top-Down Construction Method (역타공법에 적용되는 뒷채움재 위치 및 설치 형태에 대한 구조 안정성 연구)

  • Shim, Hak-Bo;Jeon, Hyun-Soo;Seok, Won-Kyun;Park, Soon-Jeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.179-179
    • /
    • 2021
  • Top-Down construction method is a method of connecting a beam to a column and using a strut to support earth retaining walls. This method has the advantage of reducing the process of underground construction by reducing the work of installation. Recently, there are a lot of cases of damage and defect occurring in H-beam backfill applied to Top-Down construction method and the concrete slab supporting H-beam backfill. For this, appropriate methods were suggested through finite element analysis of the position and installation form of the H-beam backfill.

  • PDF

A Study on the Play Space of Residential Complexes for Children in Hefei, China

  • Lee, Keon-Ha;Kim, Young-Eun
    • Architectural research
    • /
    • v.14 no.2
    • /
    • pp.57-65
    • /
    • 2012
  • This study was focused on the new town residential complex in suburban Hefei, China, which was carried out a survey on the present conditions of children's play space. The residential complexes and play spaces in Hefei, regardless of installation, the standards for the installation of play facilities were not provided legally, and the types of installation of the play facilities also were not standardized. For the play space in residential complexes in China to carry out original functions under the condition and become a place of everybody's activities not just for children, the following should be improved:(1) There is no provision and standard for the size of play space, so the standards for installation of play space with safety like Korea, Japan and the US are necessary. (2) The location of the play space should be able to guarantee maximum play activities to children, and the independence of the space should be secured by putting it in a place far from a footpath or pass way. (3) Since children's play space has different properties from those of green space and resting spaces, separate environmental planning is necessary.

A Study on the Optimal Angle Setting Considering the Stability of Photovoltaic Systems (태양광발전시스템의 안정성을 고려한 최적 각도 설정에 관한 연구)

  • Lee, Yeo-Jin;Han, Se-Kyung;Kim, Sung-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.498-504
    • /
    • 2018
  • The conventional photovoltaic(PV) systems are designed the installation angle for maximizing power output by considering a geographical characteristics, weather and climate conditions such as the solar radiation and atmosphere temperature. However, the PV generators must be designed to deal with the extreme situations like typhoons, earthquakes because PV systems are exposed to the ambient conditions and external shock due to condition of PV location. Especially, the wind has relatively higher influence on the design of PV systems, in this paper we proposed the method of determining the optimal nominal dimension of the facilities, which can withstand the maximum wind pressure. By using the proposed method, we determined the optimal installation angle for the aspect stability of PV facilities and amount of power output. Moreover, we analyzed the monthly amount of power for each installation angle of PV systems, and proposed the changing strategy of installation angle by determining the optimal angle to produce maximum power for each period.

A Study on a Installation Siting for GBAS Category-I Ground System Implementation in Gimpo Airport (GBAS Cat-I 지상시스템 시범공항 구축을 위한 설치후보지 검토)

  • Bae, Joong-Won;Jeong, Myeong-Sook;Choi, Chul Hee;Ko, Wan-Jin;Ko, Youri;Jun, Hyang-Sig
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.4
    • /
    • pp.21-30
    • /
    • 2012
  • This paper presents site survey processes and the results for installing GBAS Category-I ground system into Gimpo international airport. For siting assessment, many things should be taken into account in advance, such as installation requirement of GBAS components, future airport development plan and possible interference effects to existing facilities. Because overall performance of GBAS system can be affected by GPS signal reception environment, on-site survey should be performed carefully to measure actual GPS environmental performance and determine if any adverse multipath or RFI problems exist or not. In addtion, VDB antenna should be located to ensure line of sight for transmitting VHF signal to deliver GBAS message to aircraft. Based on the survey results, final location for GBAS system installation is selected near runway 32 in the Gimpo airport.

Analysis on Application Location of SFCL according to Circuit Breaker Burden Index with Weight Factor Estimation (차단기 부담 평가지표의 가중치 산정에 따른 초전도 한류기 적용위치 분석)

  • Park, Han-Min;Lee, Hyeong-Jin;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.47-53
    • /
    • 2015
  • As the industrial development in Korea, the power demand is rapidly increased. The power system has been extended and complicated to meet the power demand. However, the fault current increases because the structure of power system reduces the equivalent impedance. One of the solutions to reduce the fault current is Superconducting Fault Current Limiter(SFCL) and the researches of SFCL application have much conducted. In this paper, we used the Circuit Breker Burden Index(CBBI) to select application location of SFCL because the CBBI may consider a fault current of each line. In addition, this paper divided the weight factor used to calculate the CBBI on a case by case basis and analyzed this characteristics through experiment.

Locating Particle by Ultrasonic Signal and Partial Discharge Signal Pattern in GIS (초음파 신호와 부분방전 신호의 패턴에 의한 GIS내 파티클 위치 추정)

  • 곽희로;이동준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.12-18
    • /
    • 2000
  • This paper describes the analysis of ultrasonic signal and partial discharge(PD) signal patterns for each location of particle in GIS. The characteristics of the ultrasonic signal and PD signal patterns for each location were as follows; in case of particle on the electrode, large ultrasonic signals and large PD signals occurred in positive half-cycle periodically; in case of particle on the spacer, ultrasonic signals and large PD signals occurred in negative half-cycle periodically; in case of the free moving particle, ultrasonic signals and large PD signals occurred by collision non-periodically. As a result, it was confirmed that particle in GIS could be located by the comparison and analysis of ultrasonic signal and PD signal patterns.

  • PDF

Effects of Auxiliary Probe on Low Frequency Ground Impedance Measurement (저주파 접지임피던스 측정에 미치는 보조전극의 영향)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Moon, Hyun-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.367-370
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the auxiliary probes on the measurements of the low frequency ground impedance with the fall-of-potential method are described iud the testing techniques to minimize the measuring errors are proposed. The fall-of-pot ential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the characteristics of ground impedance due to the location of the potential probe, ground impedances were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from 10[m] to 50[m]. Also, the potential robe was located at 30[$^{\circ}$], 40[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$], and 180[$^{\circ}$]. The results could be help to determine the location of potential probe when the ground impedance was measured at grounding system.

  • PDF

A Lighting direction and Luminous Flux Control for Energy-efficiency under Illuminance Requirements in Indoor Lighting Systems (사용자 요구 조도 보장 에너지 효율적 실내 조명 시스템 조명 방향 및 광속 제어 기법)

  • Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.19-25
    • /
    • 2015
  • The management of energy resources for efficient utilization of the energy resources while reducing the system costs is a critical technical issue. Among many kinds of the energy resource management, the energy reduction for indoor lighting systems is getting much concern as a large portion of energy consumption has been made for indoor lightings. In this paper, an energy-efficient lighting control scheme for indoor lighting systems in order to reduce the energy consumption by controlling the luminous flux and the lighting direction under the illuminance constraints is proposed. With the use of the user location information for the luminaire which is closely located to the user, the proposed scheme firstly sets the light direction of the luminaire to be aligned to the user location. Then, an optimization problem to find the luminous flux of each luminaire is formulated in order to minimize the luminous flux sum of the luminaires with the constraints for the dynamic ragne of the luminous flux, and the light flux for each luminaire is determined by the solution of the problem. Simulation results show that the proposed scheme outperforms the luminaire control scheme with only the luminous flux control in the evaluation of satisfaction of the required illuminance level.