• 제목/요약/키워드: installation location

검색결과 608건 처리시간 0.139초

송전선로 보호용 고장기록장치의 설계 및 구현 (Design and Implementation of Fault Recorder for Transmission Line Protection)

  • 최순철;박철원
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.46-52
    • /
    • 2016
  • When a fault occurs on a transmission line, it is important to identify the fault location as speedily as possible for improvement of the power supply reliability. Generally, distance to fault location is estimated by off line from the recorded data. Conventional fault recorder uses the fault data at one end. This paper deals with the design of an advanced fault recorder for enhancement accuracy of the fault distance estimation and fast detection a fault occurrence position. The major emphasis of the paper will be on the description of the hardware and software of the fault recorder. The fault locator algorithm utilizes a GPS time-synchronized the fault data at both ends. The fault data is transmitted to the other side substation through communication. The advanced fault locator includes a Power module, MPU(Main Processing Unit) module, ADPU(Analog Digital Processing Unit) module, and SIU(Signal Interface Unit) modules. The MMI firmware and software of an advanced fault recording device was implemented.

자동심장충격기 설치현황 및 관리실태와 사용능력조사 - 충청남도 내 500세대 이상 아파트를 중심으로 (A survey on installation, management, and usability of automated external defibrillators - Focused on apartments with over 500 households in Chungnam)

  • 정준호
    • 한국응급구조학회지
    • /
    • 제21권3호
    • /
    • pp.73-84
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the installation, management, and usability of automated external defibrillators (AED) installed in the apartments with over 500 households in Chungnam. Methods: The survey included 52 apartments with over 500 households having AED in Chungnam from July 1 to August 20, 2017. The information of AED was taken from the Chungnam Provincial Office. Results: The access and use of AED was closely affected by AED installation location, locking devices, lack of publicity, and AED use education for the residents. Conclusion: Efficient education on the use and management of AED for residents of the apartments is necessary.

고속도로 졸음쉼터 설계요소 정립 연구 (A Study on Design Elements of Freeway Rest Areas for Drowsy Drivers)

  • 한다정;김응철;양재호
    • 한국도로학회논문집
    • /
    • 제20권2호
    • /
    • pp.1-8
    • /
    • 2018
  • PURPOSES : In this study, design elements of rest areas for drowsy drivers are classified and appropriate criteria for each design element are presented. METHODS : By comparing and analyzing the design criteria for rest areas, the most appropriate installation criteria were suggested by considering the driving patterns of rest area users. RESULTS : As a result of the study, elements influencing the design of rest areas for drowsy drivers are suggested such as installation location and installation type. In addition, proper separation distance between resting areas was suggested considering vehicle flow, users' fatigue and physiological needs. Other criteria for rest areas were also suggested. CONCLUSIONS : Proper safety facilities were not installed in rest areas because appropriate criteria were not established. In this study, design elements were derived and installation criteria were designed so that rest areas could be used safely and conveniently.

슬래브궤도 하부의 마이크로파일 설치효과 수치해석 (Numerical analyses on the effects of micro pile installation beneath slab tracks)

  • 이수형;김대상;이일화;정충기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.922-927
    • /
    • 2004
  • The bending moment and settlement of the slab track can be reduced by the installation of small numbers of micro piles beneath the track. This paper presents the effect of micro pile installation on the reduction of bending moment and settlement of slab track, estimated by a numerical method. The slab track is modeled as a plate based on the Mindlin's plate theory, and soil and piles are modeled as Winkler and coupled springs, respectively. The stiffness of piles is obtained by the approximate analytical method proposed by Randolph and Wroth. and the modulus of subgrade reaction is adopted to evaluate Winkler spring constant. From the analysis results, the effect of the micro pile installation is significant to considerably reduce the settlement of slab track. However, for the proper reduction of bending moments in a slab track, the pile arrangement should be reasonably taken into account to prevent the stress concentration at pile location.

  • PDF

인공어초 사후관리 현황과 발전방향 (Management after installation of artificial reefs;Present Condition and Development Scheme)

  • 이성일;안승환;김동선
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.160-161
    • /
    • 2005
  • It is important to manage artificial fish reefs with installation for restoration. The instruments of survey for artificial reefs condition(location, amount etc.) is Side Scan Sonar and Multi-beam sonar. The efficient and economic survey of the artificial reefs facility is the complete survey of the SSS(Side Scan Sonar) in all area first and then the survey of the artificial reefs by MBES(Multi Beam Echo Sounder) in the finding area.

  • PDF

$SF_6$ 가스 동축원통전극에서 금속이물 존재시의 전계해석 (The Electric Field Analysis with Conducting Particle between Coaxial Cylindrical Electrodes in $SF_6$ Gas)

  • 조국희;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.168-171
    • /
    • 1999
  • This paper describes the influence of conducting particle within the coaxial cylindrical electrodes gap under alternating voltage condition investigated using charge simulation method. If the conducting particles precent in the gas insulated system, they can cause decrement of breakdown voltage. Thus, three dimensions computations of electric fields and electrostatic forces have been carried out according to particle location. The results show a good agreement with those of outside country, which can offer a practical reference on the insulation design of domestic GIS.

  • PDF

중간층 면진시스템 설치 위치에 따른 고층건물의 지진응답 분석 (Seismic Response Evaluation of High-Rise Buildings Considering Installation Story of the Mid-Story Isolation System)

  • 김가영;이영락;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.85-92
    • /
    • 2017
  • Base isolation system is generally used for low-rise buildings. For high-rise buildings subjected to earthquake loads, a mid-story isolation system was proposed and applied to practical engineering. In this study, seismic responses of high-rise buildings considering the installation story of the mid-story isolation system were evaluated. To do this, the 20-story and 30-story building were used as example structures. Historical earthquakes such as Kobe (1995), Northridge (1994) and Loma Prieta (1989) earthquakes were employed applied as earthquake excitations. The installation location of the mid-story isolation system was changed from the bottom of the $1^{st}$ floor to the bottom of the top floor. The seismic responses of the example building were investigated by changing the location of the isolation layer. Based on the analytical results, when the seismic isolation system is applied, story drift ratio and acceleration response are reduced compared to the case without the isolation system. When the isolation layer is located on the lower part of the building, it is most effective. However, in that case, the possibility that the structure is unstable increases. Therefore, an engineer should consider both structural efficiency and safety when a mid-story isolation system for a high-rise building is designed.

해저케이블 비용 모델을 이용한 HVAC 해상변전소 적정 위치 선정에 관한 연구 (A Study on Siting of HVAC Offshore Substation for Wind Power Plant using Submarine Cable Cost Model)

  • 원종남;문원식;허재선;김재철
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.451-456
    • /
    • 2013
  • Development of the technologies for offshore wind power is proceeding actively and the installation capacity is continuously increasing because of its many advantages in comparison with the land wind power. Accordingly, project for Southwestern 2.5GW offshore wind power plant is in progress in Korea. Design of electric power systems for offshore wind power plant is very important due to its high investment and operational costs. Hence, it needs to be designed in order to minimize costs. This way can be employed in determining the installation location of offshore substation for HVAC wind power plant. According to the offshore substation site, MV inter-array cable and HV export cable lengths vary and they change a total cost regarding submarine cable. This paper represents cost models with variables which are MV inter-array cable and HV export cable lengths to locate the offshore substation for HVAC wind power plant. It is classified into submarine cable installation cost, reactive power compensator installation cost, ohmic losses, and unsupplied energy cost. By minimizing a total cost, an appropriate installation site of the offshore substation is determined.

위성항법기반 철도 적용성 연구 (Study on the Applicability of GNSS Based Railway System)

  • 정락교;신경호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1707-1713
    • /
    • 2007
  • If GNSS-based location information, expected to become the mainstream of the future technology, is applied to the future transportation, it will be of benefit to as follows; cost reducing effects on operating expanse and constructing expense due to decrease of ground unit installation, development of new technologies for train, or vehicle control system and becoming a front runner in the market. Therefore, this paper provides the minimum requirements for GNSS based system thru the studies on the applicability of GNSS based system to railway system, distinctions of the new technology between the existing technologies, and location accuracy.

  • PDF

교류전기철도 보호특성 해석 및 고장점표정 시뮬레이션 (The Analysis of Protection -Characteristics and Fault-Locator Simulation on the Electrical Railway)

  • 창상훈;이장무
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.262-269
    • /
    • 1998
  • In case the fault occurs in AC power supply network, protective relaying system must selectively detect line-to-line/ground fault and immediately cut off the power flow into the fault location for guaranteeing the safety of people, electric vehicle and ground installation etc. It is the most important point in power system operation to minimize the fault duration by rapid trip scheme and accurate estimation of the fault location. In this paper, we analyze the load characteristics of each vehicle, perform the fault analysis of AC power supply network using AT current-ratio method. The result shows its usefulness.

  • PDF