• Title/Summary/Keyword: installation location

Search Result 608, Processing Time 0.035 seconds

Three Dimensional Characteristics of the Airflow in Unidirectional Vehicle Tunnels

  • Kim, Sang-Hyun;Kim, Doo-Young;Choi, Pan-Gyu;Lee, Chang-Woo
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2008.10a
    • /
    • pp.287-300
    • /
    • 2008
  • Airflow distributions along tunnel and over the cross section are critical in selecting installation location of the velocity monitor to obtain the representative data for ventilation as well as fire safety systems. This paper aims at performing CFD and on-site studies to analyze the longitudinal and cross-sectional distributions of the air velocity in tunnels employing longitudinal and semi-transversal ventilation systems. This study can ultimately contribute to selecting the monitor type as well as the optimal installation locations in vehicle tunnel.

  • PDF

A Study on the Implementation of A Fire Detection Monitoring System to Improve Data-Rate in WSN Environment (WSN 환경에서 전송률 향상을 고려한 화재감지 모니터링 시스템 구축에 관한 연구)

  • Lee, Jae-Soo;Yun, Chan-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.96-102
    • /
    • 2011
  • There are many problems with the fire detection devices being used in currently, because it is difficult to find location of the source of fire and determine where devices are working or not. In this paper, we proposed fire detection and rescue system using wireless sensor network that can be real-time monitoring and determine safe exit. Fire detection and rescue system based on ubiquitous sensor network can know exactly source of fire and help determine rescue tactics using sensing data from wireless sensor nodes. Transmitted wirelessly in real-time thermal sensor and gas sensor information to analyze the GUI to monitor the status information output to the screen by use of a system implemented in everyday life, looked at the possibility.

A Study on the Electromagnetic Transients in A Power System (전력계통의 전자과도현상에 관한 연구)

  • 김경철;강창원;이일무
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.59-64
    • /
    • 2001
  • Transient in an electrical system are generated by lightning and switching. This paper presents analysis of switching and lightning surge, and means of limiting the voltage magnification transient for high voltage power systems by using EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor correction banks to harmonic filters. An inductance in series with the power factor correction bank was used to decrease the transient voltage at the customer bus to acceptable levees. The interception of the impulse from the phase wire is fairly straight forward by properly installed surge arresters. The simulation shows that the addition of the surge arrester at the customer location can achieve a substantial reduction of the transient magnitude.

  • PDF

A Study on an Optimal Design of Jet Fan Location Considering the Voltage Drops in Tunnels (전압강하를 고려한 터널내 환기 및 방재팬의 경제적 위치선정에 대한 연구)

  • Kim, Eun-Soo;Kim, Hyo-Gyu;Song, Jung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.105-109
    • /
    • 2004
  • 우리나라 지형의 특성은 약 70%가 산으로 이루어져 있다. 이러한 지형적 여건은 교통과 관련된 사회간접 자본의 증가로 이어지며, 최근에는 산업의 발전에 힘입어 교통량의 증가와 물류비용의 절감을 목적으로 철도 및 도로의 건설시 터널의 계획 및 시공이 증가되고 있는 추세이다. 이에 따라 터널의 환경개선과 화재시 제연을 목적으로 설치되는 제트팬(Jet Fan)의 용량이 차지하는 전기적 비중이 높아지고, 전압강하에 대한 손실율이 증가되고 있다. 따라서 제트팬의 설치시 배치방법과 터널의 길이에 따른 전기실 배치를 Case 별로 분류하여 전압강하를 계산하고 분석하여 가장 효율적이며 경제적인 방안을 연구하고 정리하여 향후 설계시 기초자료를 제공하고자 하였다.

  • PDF

Analysis of the Electromagnetic Clutch for Emergency Power Generator (비상발전기용 전자클러치의 자계해석)

  • Jeon, Mun-Ho;Kim, Chang-Eob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.111-116
    • /
    • 2011
  • This paper deals with the electromagnetic clutch which stop the generator at emergency by using the engine power of generator. The electromagnetic field was analyzed using Flux-2d program with different conditions : voltage, air gap, coil locations. As a result, the maximum magnetic flux density of electromagnetic clutch occurred between the coil and wheel : 0.27[T], 0.41[T] at 12[V], 24[V]. The maximum flux density was at the center location of the coil.

A Study on the Detection of Ultrasonic Signal for the Diagnosis of Transformer (변압기 예방진단을 위한 초음파 신호 검출에 관한 연구)

  • 권동진;광희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.6
    • /
    • pp.65-70
    • /
    • 1995
  • This paper describes the detection of the ultrasonic signals reduced by materials of a transformer for diagnosis of the transformer using ultrasonic signal which is generated by partial discharge. When partial discharge is generated on the surface of the winding and between the winding and the core in the transformer, the ultrasonic signal can be measured as the proper selection of the ultrasonic detectors' location.

  • PDF

Effective Route Decision of an Automatic Moving Robot(AMR) using a 2D Spatial Map of the Stereo Camera System

  • Lee, Jae-Soo;Han, Kwang-Sik;Ko, Jung-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.45-53
    • /
    • 2006
  • This paper proposes a method for an effective intelligent route decision for automatic moving robots(AMR) using a 2D spatial map of a stereo camera system. In this method, information about depth and disparity map are detected in the inputting images of a parallel stereo camera. The distance between the automatic moving robot and the obstacle is detected, and a 2D spatial map is obtained from the location coordinates. Then the relative distances between the obstacle and other objects are deduced. The robot move automatically by effective and intelligent route decision using the obtained 2D spatial map. From experiments on robot driving with 240 frames of stereo images, it was found that the error ratio of the calculated distance to the measured distance between objects was very low, 1.52[%] on average.

Analysis Technique of Risk Voltage around Grounding Electrode by New Touch and Step Voltage Measurement Methods (새로운 접촉 및 보폭전압 측정법에 의한 접지전극 주위의 위험전압 분석기법)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.81-86
    • /
    • 2012
  • This paper describes the analysis technique of risk voltage around grounding electrode by new touch and step voltage measurement methods. We have analyzed three techniques for risk voltage measurement, such as footprint-electrode method, test-probe method, and simulated-personnel method. We have selected test-probe method considering applicability of site. In order to reduce error related to the location of the auxiliary electrode, we propose a new approach to perform risk voltage measurement with minimum errors and short auxiliary electrode distances. Field tests were carried out at a grounding grid. It can be concluded that the proposed method will be satisfactory for risk voltage measurement.

A Study on Generator Temperature and Power Converter Efficiency according to change of Wind Velocity (풍속 변화에 따른 발전기 온도 및 전력변환장치 효율에 관한 연구)

  • Song, Young-Sang;Han, Woon-Ki;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.8-13
    • /
    • 2015
  • Recently, because a renewable power source must operate as a constant rate in accordance with RPS(Renewable Portfolio Standard), the study of the renewable power sources has been ongoing. Especially because of noise of wind turbine, troubleshooting, and urban greening business, research related with small wind turbine are underway. The economics and reliability are important parts for the activation of small wind turbine, such as solar energy. In this paper, by analyzing the temperature variations for each location and efficiency of power conversion devices in accordance with short period wind speed changes in simulation test, we reviewed the safety about temperature variations of wind generator and the method of selection of power converter.

A Study on the Comparison of Calculated the Indoor Illuminance Values by Lighting Simulation Softwares for Suitable Prediction About Indraft of Daylight (자연채광 유입에 따른 실내 조도의 적합한 예측을 위한 조명시뮬레이션 소프트웨어 비교 연구)

  • Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.92-96
    • /
    • 2007
  • Architecture design has need of daylight prediction to utilize daylight efficiently. But it is difficult to predict the exact value of available daylight in buildings. Using various lighting simulation software is not difficulty, but we can find different results under the same conditions. The purpose of this paper is to compare simulation values from various software such as Lumen-micro 2000, Lightscape 3.2, and Relux 2006. The same space and parameters of daylight(location of space and window, date, time, and skylight condition) are considered to conduct various simulation conditions.

  • PDF