• Title/Summary/Keyword: installation location

Search Result 609, Processing Time 0.025 seconds

Developing the Installation Guideline of Building Monitoring Systems for Hazardous Symptom Measurements with Visual Perception (시지각적 요소를 갖춘 건축물 위험징후 측정 모니터링 시스템 설치 가이드라인 개발연구)

  • Kim, Heejae;Kim, Geunyoung;Shin, Jungjae
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.374-382
    • /
    • 2020
  • Purpose: Recently, structural defects in old safety management facilities have led to the collapse of buildings and facilities. The purpose of this study is to develop guidelines for the installation of regular monitoring systems that determine the optimal sensor location for monitoring exhibition space building sensors equipped with visual elements in order to analyze the risk signs of exhibition space buildings and develop measurement technology. Method: The components, installation locations, alarm criteria, and management measures of the instrument are presented. Result: A measure was proposed to determine the location of sensors, secure signal processing technology for analysis by having unified visual perception, and configure optimal 'risk sign detection' based on sensor monitoring through test-bed operation. Conclusion: The results of this study can be prepared against the disasters that may arise from the collapse of exhibition buildings, and contribute to strengthening safety management capabilities.

A study on installation location of radar for minimizing blind area in the construction of VTS system of Kangjeong Port (강정항 VTS 시스템 구축시 음영구역 최소화를 위한 레이더의 위치설정에 관한 연구)

  • LEE, Seung-Hi;KIM, Kwang-Il;AHN, Jang-young;LEE, Chang-Heon;CHOI, Chan-Moon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.2
    • /
    • pp.187-195
    • /
    • 2017
  • We have studied the efficient operation of the radar and the appropriateness of the installation location, when constructing the VTS system. As the Civil-Military Complex Harbour (Kangjeong Port) is completed in 2016, we set the control area within 10 nautical miles centering on Kangjeong Port, and found out and removed the operational radar blind area of VTS system to provide safe navigation information for vessels that navigating this area. Assuming that two international cruise ships entering at the same time, we performed the radar simulation and compared the images by considering the three sites of Kangjeong Port, Miaksan and Seoguipo Port. Simulation results for a single radar installed at Kangjung Port indicate that the blind area was largely affected by two large cruise ships and the surrounding islands. The blind area due to Kogunsan was considerably large when installed in Miaksan, but the blind area due to the influences of Beomseom, Moonseom and Seopseom was negligibly large. It seems that additional radar installation is necessary as a complementary solution to solve this blind area. When two radars were installed at Miaksan and Kangjeong Port, the residual blind area due to the Seopseom was $0.25km^2$ at 0.1~0.33 nautical miles in the southeast direction from Seopseom. In addition, the remaining blind area with two cruise ships mutually influenced was $0.18km^2$, which did not occur with a single cruise ship.

Performance Evaluation of Vibration Control of Adjacent Buildings According to Installation Location of MR damper (인접건축물의 진동제어를 위한 MR감쇠기의 위치 선정에 관한 연구)

  • Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.91-99
    • /
    • 2012
  • In recently, the vibration control of adjacent buildings have been studied and magneto-rheological(MR) fluid dampers have been applied to seismic response control. MR dampers can be controlled with small power supplies and the dynamic range of this damping force is quite large. This MR damper is one of semi-active dampers as a new class of smart dampers. In this study, vibration control effect according to the installation location of the MR damper connected adjacent buildings has been investigated. Adjacent building structures with different natural frequencies were used as example structures. Groundhook control model is applied to determinate control force of MR damper. In this numerical analysis, it has been shown that displacement responses can be effectively controlled as adjacent buildings are connected at roof floors by MR damper. And acceleration responses can be effectively reduced when two buildings are connected at the mid-stories of adjacent buildings by MR damper. Therefore, the installation floor of the MR damper should be selected with seismic response control target.

The Study of the Most Suitable Location of Luminaire for Road Tunnel Lighting System (도로터널에서 최적의 조명기구 위치 연구)

  • 한완모;장우진;이인환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2004
  • As we know, topography of korea is composed of many mountains. Also, the volume of traffic is increasing more and more nowadays. So, many tunnels are being constructed to reduce cost of transport and time. Thus, tunnel illumination was considered as the most important thing to make safe traffic conditions. In the past, we installed luminaires on the wall in tunnel, but currently we are installing those on the ceiling. Wherever luminaires are installed on the ceiling, the electric designer may not have known the proper point to install luminaires. Therefore, we researched this project to resolve above problems with abundant experience and accurate data through simulation(Lightscape program). As a result of research, mounting luminaires on the ceiling are better than wall because uniformity is more regular and utilization factor is also higher and then brightness is adequate as well, whereby installation on the ceiling is economical. Therefore, it is suitable that luminaires are installed on the ceiling in tunnel than wall.

Performance Evaluation of Vibration Control According to Installation Location of a Sky-bridge (스카이브릿지 설치위치에 따른 고층건물의 진동제어 성능평가)

  • Kim, Hyun-Su;Park, Yong-Koo;Ko, Hyun;Lee, Ui-Hyun;Lee, Dong-Guen
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.3
    • /
    • pp.65-74
    • /
    • 2010
  • In this study, the vibration control effect according to the installation location of the sky-bridge and the difference of natural periods of the connected buildings has been investigated. To this end, 40-story and 50-story building structures connected by a sky-bridge were used as example structures and the equivalent modeling method was used. Boundary nonlinear time history analyses were performed using El Centro and Taft earthquakes to investigate the dynamic behavior of the example structures and vibration control effect of the sky-bridge. Based on numerical results, it has been shown that displacement responses can be effectively controlled as the installation floor of the sky-bridge increases and acceleration responses can be effectively reduced when the sky-bridge is installed on the mid-stories of the example building.

  • PDF

Analysis of Seismic Response According to Installation Location of Seismic Isolation System Applied to High-Rise Building (고층 건물에 적용한 면진 시스템의 설치 위치에 따른 지진 응답 분석)

  • Kim, Min-Ju;Kim, Dong-Uk;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.81-88
    • /
    • 2018
  • Seismic isolation systems have typically been used in the form of base seams in mid-rise and low-rise buildings. In the case of high-rise buildings, it is difficult to apply the base isolation. In this study, the seismic response was analyzed by changing the installation position of the seismic isolation device in 3D high - rise model. To do this, we used 30-story and 40-story 3D buildings as example structures. Historic earthquakes such as Mexico (1985), Northridge (1994) and Rome Frieta (1989) were applied as earthquake loads. The installation position of the isolation device was changed from floor to floor to floor. The maximum deformation of the seismic isolation system was analyzed and the maximum interlaminar strain and maximum absolute acceleration were analyzed by comparing the LB model with seismic isolation device and the Fixed model, which is the base model without seismic isolation device. If an isolation device is installed on the lower layer, it is most effective in response reduction, but since the structure may become unstable, it is effective to apply it to an effective high-level part. Therefore, engineers must consider both structural efficiency and safety when designing a mid-level isolation system for high-rise buildings.

A Study on Location and User Satisfaction of the Green Buffer Zone in Gwanggyo New Town (광교신도시 완충녹지의 입지와 이용만족도 연구)

  • Kim, Ju-Ok;Choi, Won-Bin;Shin, Ji-Hoon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.6
    • /
    • pp.21-33
    • /
    • 2017
  • The purpose of this study is to find out that it can be provided as a basic data to increase the satisfaction with users in the placement and creation of the Green Buffer Zone. In this study, the research was started on the Green Buffer Zone in Gwanggyo new town, which was rebuilt as the zone to use according to the change of legal installation standard of the zone. The subject of this study is the Green Buffer Zone in Gwanggyo new town, which is expected to be completed in step 4 of 2016. As a result of analysing the location and use characteristics of the Green Buffer Zone, the following conclusions were made. First of all, it is categorized into two categories by Buffering / disaster prevention type and land to use adjustment type. Second, the buffer space of commercial space and housing is satisfying, but in commercial space, there is a need for a cushioning function and housing spaces require improvements in the functioning of the landscape. Third, the function of the Green Buffer Zone resets to cushioning function, disaster prevention function, landscape function, utilization function. and The installation criteria are proposed to environmental pollution, noise abatement, and planting trees, etc. Lastly, the future utilization plan considering the location and use characteristics of the Green Buffer Zone is as follows. In the planning stage, preference is given to the characteristics of use of arranging green facility. It is necessary to manage the planned facilities as much as possible by changing them if necessary. Construction stage, it restrictively reflects landscaping facilities within the Green Buffer Zone function. After stage, This study will prioritize the target areas and select necessary areas and need to make efforts to prevent indiscriminate greenery encroachment.

Frequency Distribution of Mechanical Noise Signals for Ultrasonic Wave and AE Sensor with Brush Spark of DC Motor (직류전동기 브러시 섬락에 따른 기계적 노이즈 신호의 주파수 분포)

  • 이상우;김인식;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.36-43
    • /
    • 2004
  • In this paper, the frequency spectra from respective mechanical noise signals detected using ultrasonic wave and AE(Acoustic Emission) sensor were analysed to under spark generation between brush and commutator side with arbitrarily 15$^{\circ}$ rotation for brush from the DC motor in operation. Also, the frequency spectra from respective magnetizing noise signals detected using ultrasonic wave and AE sensor were analysed to under neutral point for brush from the DC motor in normal operation. And the analyses and comparison between the mechanical noise signal and magnetizing noise signal of ultrasonic wave with brush location change from the DC motor in operation. As the experimental results, tile mechanical noise signal of ultrasonic wave under spark generation between brush and commutator side with brush location change from the DC motor in operation were increased about 2.5∼3.0 times than magnetizing noise signal of ultrasonic wave form the DC motor in normal operation. Also, the main frequency band for mechanical noise signals of AE under spark generation between brush and commutator side with brush location change from the DC motor in operation, appeared about 1.3[MHz]∼l.5[MHz] by the fast fourier transform.

Analysis on Current Limiting and Magnetizing Characteristics Due to Winding Locations of Superconducting Fault Current Limiter Using E-I Core (E-I철심을 이용한 변압기형 초전도한류기의 권선 위치에 따른 전류제한 및 자화특성 분석)

  • Kim, Bo-Hee;Choi, Sang-Jae;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.2
    • /
    • pp.106-110
    • /
    • 2017
  • This paper compared current limiting characteristics of superconducting fault current limiter (SFCL) using E-I core due to the location of windings. Since E-I core has three legs and two magnetic paths, the current limiting characteristics of SFCL were expected to be affected by the installation location of windings, either center leg or right/left leg. To analyze its characteristics, the electrical equivalent circuit of the SFCL were derived and the electromagnetic analysis for the SFCL with the designed structure were performed. From the short-circuit tests, the hysteresis curve and the voltage-current trajectory of the SFCL due to the installation location of windings were extracted and compared each other. The SFCL with windings in the center leg of E-I core was shown to be larger magnetizing inductance compared to the one with windings in the right or left leg of E-I, which was analyzed from the hysteresis curve. In addition, larger decreased fault current right after the fault occurrence in the SFCL with windings in the center leg of E-I core was confirmed than the SFCL with windings in the right or left leg of E-I.

A Study on Algorithm Robust to Error for Estimating partial Discharge Location using Acoustic Emission Sensors (AE(Acoustic Emission) 센서를 이용한 오차에 강인한 부분방전 위치추정 알고리즘에 관한 연구)

  • Cho, Sung-Min;Shin, Hee-Sang;Kim, Jae-Chul;Lee, Yang-Jin;Kim, Kwang-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.69-75
    • /
    • 2008
  • This paper presents an algorithm robust to error for estimating partial discharge (PD) location using acoustic emission sensors. In operating transformers, the velocity computing of the acoustic signal is difficult because the temperature of the Insulation oil is not homogeneous. So, some error occurs in the process. Therefore, the algorithm estimating PD location must consider this error to provide maintenance person with useful information. The conventional algorithm shows the PD position as a point, while the new algorithm using LookUp-Table(LUT) shows PD position as error-map visually. The error-map is more useful than the conventional result because of robustness to error. Also, we compared performance of them, by adding error to data on purpose.