• 제목/요약/키워드: installation deviation

검색결과 85건 처리시간 0.026초

부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안 (Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems)

  • 이유정;김규호;이상근;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.

30W급 LED 투광등 설치각도에 따른 히트싱크 온도분포에 관한 연구 (A Study on Heatsink Temperature Distribution according to the Installation Angle of a 30W LED Floodlight)

  • 이영호;이중섭;정한식
    • 한국기계가공학회지
    • /
    • 제18권8호
    • /
    • pp.24-30
    • /
    • 2019
  • This study investigated the heat dissipation characteristics of a heat-sensitive LED. The results of the empirical test showed that the best temperature intensification was found at 90 with 15-fins, and the heatsink installed perpendicular to the direction of the flow of air was directly connected to the air in the largest heat shield area, leading to the best cooling, and the number of fin also resulted increase in the heat discharge area, resulting in the largest cooling action with 15 fins. It was found that the rate of air flow changed in the range of 1.5m/s to 2.5m/s, but only by a deviation of about $2^{\circ}C$ to $3^{\circ}C$ from the current state of 15 fins at 2.5m/s, and the rate of air flow increased, but the performance of the heat release was not significantly increased. As a result wind speed with minimum air flow conditions of 1.5m/s can greatly contribute to the heat dissipation performance.

고정식 초점형 격자가 적용된 비정절 실리콘 평판형 검출기에서 초점-격자와 두부 팬텀의 중심 변위에 의한 화질 특성에 관한 연구 (A Study of Image Characteristics due to Focus-Grid and Head Phantom Decentering from the Armorphos Silicon Thin Film Transistor Detector the Fixed Focus-Grid is Applied)

  • 최준구;김병기;차선화;김경수
    • 대한디지털의료영상학회논문지
    • /
    • 제9권1호
    • /
    • pp.7-15
    • /
    • 2007
  • 고정식 초점형 격자가 적용된 비정질 실리콘 평판형 검출기에서 초점-격자간 중심변위와 두부 팬텀의 검출기내 위치 변위가 영상 특성에 미치는 영향을 조사하여, 디지털 의료영상 장비의 올바른 사용 방법을 제안하고자 한다. 고정식 초점형 격자를 적용한 비정질 실리콘 평판형 검출기에서 두부 팬텀을 사용하여 초점-격자간 중심 변위와 두부 팬텀의 위치 변위에 따라 영상을 획득 하였다. 획득된 영상을 NIH(Image J) 영상 분석 프로그램을 이용하여 동일 영역에서의 픽셀값(Pixel value), 히스토그램(Histogram), 도면형상(plot profile), 표면도(Surface plot)등을 분석하고, 표준 촬영 영상과 비교 하였다. 초점-격자간 측 방향 중심 변위와 초점-격자와 두부 팬텀의 이중 변위는 수평, 대각선으로 증가할수록 픽셀의 평균값과 표준편차값이 비례적으로 감소하였다. 또한 높은 픽셀값의 빈도수가 상당히 감소하여 영상의 대조도를 저하시켰고, 변위가 증가할수록 영상 왜곡현상도 증가하였다. 다음으로 두부 팬텀 위치 변위의 픽셀 평균값은 큰 변화가 없었으나 수평, 대각선으로 증가할수록 높은 픽셀값의 빈도수가 감소하는 양상을 보여 영상의 대조도가 저하 되었다. 디지털 검출기의 넓은 관용도와 후처리 능력은 영상의 화소 잡음이 증가하여도 방사선사들이 인지하지 못할 수 있다. 따라서 방사선사는 격자가 장착된 디지털 검출기에서 화소 잡음을 증가시키는 촬영 요인들을 정확히 인지하여 검사에 임해야 할 것이다.

  • PDF

열차하중, 속도변화에 따른 토공상 콘크리트 슬래브궤도의 거동특성연구 (Study of the Behavior of Concrete Slab Track on Earthwork According to the Variation of Train Axle Load and Speed)

  • 전희광;강윤석;박용걸
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6788-6798
    • /
    • 2015
  • 최근 고속철도에서는 열차의 운영속도가 향상되고 동력분산형 차량의 도입이 증가하고 있다. 또한 콘크리트 슬래브궤도의 수요가 증가하고 설계단면감소 추세가 예상되면서 설계하중 및 속도변화로 인한 콘크리트 슬래브궤도의 보다 명확한 내부거동평가가 요구된다. 본 연구의 목적은 열차하중과 열차속도 변화에 대하여 콘크리트궤도구조와 노반의 역학적인 거동을 평가하고 규명하는 것이다. 이를 위하여 도상콘크리트층과 콘크리트기층의 속도, 하중 변화에 따른 거동을 해석하여 평가하였다. 또한 호남고속철도 토노반 콘크리트 궤도에 부설 중에 매립된 도상콘크리트 변형율계로 HEMU-430X 열차와 KTX-호남의 170km/h에서 최대 402km/h까지 측정된 측정결과와 해석결과를 비교분석하였다. 분석결과, 속도향상에 따른 증가경향을 확인하고 선형회귀선을 도출하였으며 슬래브 층의 결합상태와 비결합 상태의 가정상태의 해석응력과 현장의 콘크리트 슬래브 내부응력을 비교할 수 있었다. 그 결과 축중이 작은 동력분산식 HEMU 430-X 열차의 402km/h주행 시 발생응력과 KTX-호남의 발생응력이 유사하게 발생함을 알 수 있었고 속도증속에 따라 발생응력의 표준편차 값이 크게 증가하는 것을 확인하였다.

SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (2) -시스템의 정도 평가 - (Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (2) - Evaluation for Precision of System -)

  • 박주삼;고탁창언
    • 수산해양기술연구
    • /
    • 제39권4호
    • /
    • pp.318-325
    • /
    • 2003
  • SPB방식과 시스템을 수조실험에서 검증하였다. 이상의 연구 성과를 정리하면 다음과 같다. 1) 핑거와 비슷한 펄스를 하이드로폰으로부터 발생시켜 수파기의 협빔과 광빔의 양빔 모드의 위상빔어레이 중심간 거리를 보정하여 전후, 좌우의 위상빔에 대한 위치측정 정도를 비교, 분석하였다. 측정위치오차는 협빔 모드의 전후위상빔에서 6.4cm, 좌우위상빔에서 6.3cm로 위치측정 정도는 고정도 이었으며, 광범 모드에서는 각각 24cm, 23cm로 협빔 모드보다 위치측정 정도는 4 배 정도 낮았다. 2) 핑거를 이미 계산된 위치로 이동시켜 핑거동기방식에 의한 거리정보와 SSBL 방식에 의한 방위정보를 자동, 연속으로 측정하였으며, 핑거동기 방식에 의한 핑거의 측정거리, SSBL. 핑거동기 바이오텔레메터리 방식에 의한 핑거의 측정위치, 핑거의 측정이동속도를 구해 기존의 값과 비교하여 새롭게 개발한 방식과 시스템의 유효성을 검증하였다. 핑거동기 방식에 의해 구한 핑거의 측정거리 오차는 1.8cm, SSBL. 핑거동기 바이오텔레메터리 방식에 의해 구한 핑거의 측정위치 오차는 7.7cm로 고정도로 측정이 기능하였으며, 핑거의 측정이동속도는 기존의 값에 대체적으로 일치하였다.

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

  • Huh, Young-June;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제42권3호
    • /
    • pp.139-146
    • /
    • 2012
  • Purpose: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. Materials and Methods: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. Results: The deviation of the entry point and angulation of the central axis in the reference plane were $0.47{\pm}0.27$ mm, $0.57{\pm}0.23$ mm, and $0.64{\pm}0.16^{\circ}$, $0.57{\pm}0.15^{\circ}$, respectively. However, for the two different angulations in each group, the $20^{\circ}$ angulation showed a greater error in the deviation of the entry point than did the $10^{\circ}$ angulation. Conclusion: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

2중 컨버터 구조를 갖는 계통 연계형 UPS의 DC 충전 알고리듬에 관한 연구 (A Study on DC Changing Algorithm of the Line-Interactive UPS with Dual Converter Structure)

  • 이우철;유동상
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.27-34
    • /
    • 2005
  • 본 논문에서는 2개의 컨버터 구조를 갖는 삼상 계통 연계형 UPS에 대하여 연구한다. 삼상UPS시스템은 2개의 능동 전력 보상기 구조로 이루어져 있다. 하나는 직렬형으로 .전원전압과 동상의 전압원으로 동작하여 전원전압의 변동, 왜곡시에도 정현파 전원전류와 고역률을 갖도록 동작한다. 병렬형은 전원전압과 위상을 맞춘 종전의 정현파 전압원으로 동작하여 부하에 안정되고 낮은 THD를 갖는 정현파 전압을 공급한다. 본 논문에서는 직렬형, 병렬형 능동보상기에서 전원전압의 크기에 따라 충전 방법에 대하여 제시한다. 종전의 계통 연계형 UPS는 DC 충전과 출력전압을 동시에 제어하였는데, 2개의 컨버터 구조를 갖는 UPS 시스템에서는 직렬형 보상기도 DC 충전을 할 수 있어 직렬형과 병렬형을 사용한 충전 알고리듬을 연구할 필요가 있다. 따라서 DC link단의 전압을 안정시켜 본래의 직렬형, 병렬형 구조의 보상기의 안정성 향상에 기여할 수가 있다. 제안된 방법의 타당성은 시뮬레이션과 실험 결과를 통하여 입증된다.

상용 보호열판법 열전도율 측정장비를 사용한 열유속법의 열전도율 값 보정에 대한 실험적 연구 (Experimental Study on Correction of Thermal Conductivity Obtained by Heat Flow Method using Commercial Guarded Hot Plate Method Apparatus)

  • 이진성;김경수;김유일;우석민;윤승진
    • 한국해양공학회지
    • /
    • 제29권2호
    • /
    • pp.169-174
    • /
    • 2015
  • This paper addresses experimental methodologies to measure the temperature-dependent thermal conductivity of the insulation materials popularly used for LNG cargo containment systems. The measurement techniques considered in this paper are the guarded hot plate (GHP) method and heat flow method (HFM). The former is based on the power supplied to the hot plate to keep the temperature constant, and the latter is based on a direct heat flux measurement. In order to improve the accuracy of the HFM, the thermal conductivity obtained by GHP was cross-compared with the HFM results, and a calibration factor was derived. It was found that the thermal conductivities measured by the two methods corresponded well under room temperature, but the deviation tended to slightly increase as the temperature decreased. Because of the easy installation and operability of HFM, it can be used to measure thermal conductivity in a large scale mock-up test or unit insulation panel test, where the GHP method is difficult to apply.

내진보강된 콘크리트 교량의 손상도 곡선 (Fragility Curves of Seismic Retrofitted Concrete Bridges)

  • 김상훈;김두기;서형렬;김종인
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.203-210
    • /
    • 2004
  • 1994년 Northridge 지진 이후 내진보강한 콘크리트 교량의 손상도 곡선을 유도하였고, 이 곡선을 사용하여 교각과 신축이음장치에 설치한 강재 재킷과 구속부재의 내진보강 효과를 고찰하였다. 손상도 곡선을 2변수(중간값과 대수 표준편차) 대수정규분포함수의 형태로 가정하였고, 최대지반가속도의 함수로 나타냈다. 여기서 Maximum likelihood 방법을 사용하여 대수정규분포함수의 2변수를 구하였고, FEMA SAC 프로젝트의 60개 Los Angeles 지진 시간이력을 지진해석에 사용하였다. 교각의 강재 재킷은 교량의 전반적 손상등급에서 내진보강 효과를 나타냈고, 구속부재는 낙교 등 교량의 심한 손상등급에서 효과적이었다. 여기서, 교각은 Dutta & Handel이 제시한 5개 손상등급으로 손상을 정의하였고, 신축이음장치에서는 구속부재의 파괴 및 낙교를 교량의 심각한 손상으로 규정하였다.

Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study

  • Young Woo Song;Seung Ha Yoo;Ui-Won Jung
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권1호
    • /
    • pp.1-11
    • /
    • 2024
  • PURPOSE. The present experiment aimed to evaluate the placement accuracy of fully guided implant surgery using a mucosa-supported surgical guide when the protocol of osteotomy and installation was modified (MP) compared to when the protocol was sequentially and conventionally carried out (CP). MATERIALS AND METHODS. For 24 mandibular dentiform models, 12 dentists (6 experts and 6 beginners) performed fully guided implant placements two times at the right first and second molar sites using a mucosa-supported surgical guide, once by the CP (CP group) and at the other time by the MP (MP group). The presurgical and postsurgical stereolithographic images were superimposed, and the deviations between the virtually planned and actually placed implant positions and the procedure time were compared statistically (P < .05). RESULTS. The accuracies were similar in the CP and MP groups. In the CP group, the mean platform and apex deviations at the second molar site for the beginners were +0.75 mm and +1.14 mm, respectively, which were significantly larger than those for the experts (P < .05). In the MP group, only the mean vertical deviation at the second molar site for the beginners (+0.53 mm) was significantly larger than that for the experts (P < .05). The procedure time was significantly longer for the MP group (+94.0 sec) than for the CP group (P < .05). CONCLUSION. In fully guided implant surgery using a mucosa-supported guide, the MP may improve the placement accuracy when compared to the CP, especially at sites farther from the most-posterior natural tooth.